Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Constrained power reference control for wind turbines

The cost of wind energy can be reduced by controlling the power reference of a turbine to increase energy capture, while maintaining load and generator speed constraints. We apply standard torque and pitch controllers to the direct inputs of the turbine and use their set points to change the power output and reduce generator speed and blade load transients. A power reference controller increases the power output when conditions are safe and decreases it when problematic transient events are expected. Transient generator speeds and blade loads are estimated using a gust measure derived from a wind speed estimate. A hybrid controller decreases the power rating from a maximum allowable power. Compared to a baseline controller, with a constant power reference, the proposed controller results in generator speeds and blade loads that do not exceed the original limits, increases tower fore-aft damage equivalent loads by 1%, and increases the annual energy production by 5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

A systematic literature review on residential demand response with a focus on opportunities for low-income communities

Demand Response improves efficiency and grid stability, reducing peak load and total system costs. It can potentially contribute to other societal aspects, including mitigating climate change and improving air quality, health, stress levels, and comfort. This paper reviewed the literature on residential demand response programs in the United States, through the lens of the five energy justice principles, identifying and categorizing a set of 165 papers from 1960 to 2024. As a result, we observe significant progress in distributive justice, however, mostly focused on increasing participation rather than attending specific needs of historically marginalized communities. Concordantly, recognition and procedural justice dimensions are lagging, while cosmopolitan justice studies are scarce, underscoring a need to improve the measurement of impacts resulting from the implementation of demand response programs. Future research opportunities include the consolidation of standardized definitions and metrics, to better understand burdens and needs of diverse residential users. In terms of policy, collection and transparent access to standardized data is required as a condition to the design of flexible, customizable, transparent, and easy to navigate demand response programs. As a result, a better understanding of and engagement with customers has the potential to increase adoption rates, persistence in the program, and overall impacts for the system, households, and society.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of electric vehicle charging on the power demand of retail buildings

As electric vehicle penetration increases, charging is expected to have a significant impact on the grid. Electric vehicle charging stations will greatly affect a building site's power demand, especially with the onset of fast charging with power levels as high as 350 kW per charger. Here, we assess how electric vehicle charging stations would impact a retail big box grocery store, exploring numerous station sizes, charging power levels, and utilization factors in various climate zones and seasons. We measure the effect of charging by assessing changes in monthly peak power demand, electricity usage, and annual electricity bill, computed using three distinct rate structures. We find that an electric vehicle station has the potential to dwarf a big box building's power demand if behind the same meter, increasing monthly peak power demand at the site by over 250%. Cold-climate areas paired with rate structures incorporating high demand charges are most susceptible for significant changes to the annual electricity bill, with increases as high as 88%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Harmonic Signals Dataset

The Harmonic Signals Dataset (HSD) consists of one-dimensional time series data collected from current sensors with a goal of providing data for research and development of Non-Intrusive Load Monitoring (NILM) with high sample rate (800kHz) sensors. NILM seeks to detect and characterize electrical equipment operating within a facility by sensing changes in electrical current on the building power system associated with the equipment. To provide data with a known ground truth, but with the realism of a signal introduced within a building facility, a series of known ground truth signals were injected as voltage into the power system of a building and measurements of the signals at multiple locations across the building power system were made with electrical current sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Initial Design Curves for Alloy 709 for an Improved Creep-fatigue Design Method

Creep-fatigue (CF) interaction damage is the primary damage mode for high-temperature structural components subjected to cyclic loading. Over the past several decades, researchers within the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC), Section III, Division 5, have focused on developing elevated temperature code rules to ensure conservative structural designs that mitigate CF failure in high-temperature reactors. The existing CF evaluation methodologies in the Code are based on the creep and fatigue damage diagram approach, which is complex and often excessively conservative. The alternative CF evaluation approach proposed here is intended to significantly simplify the evaluation procedure while reducing conservatism in high-temperature component design analysis. This alternative CF evaluation method integrates the elastic–perfectly plastic (EPP) analysis approach with the simplified model test (SMT) CF design concept, leveraging the advantages of both methods. This report presents the preliminary analysis and the approach for developing CF design curves for Alloy 709, utilizing fatigue and CF data generated for the 100,000-hr Code Case to support its qualification to ASME Section III, Division 5 for Class A construction of high temperature reactors. This study is to support the incorporation of Alloy 709 in this alternative CF evaluation method. Recommendations for the remaining work needed to complete the effort are also provided.

36 MATERIALS SCIENCE↗

Short-term exposure to elevated suspended sediment increases oxygen uptake of gilled larval Eastern Hellbender ( Cryptobranchus alleganiensis ) salamanders

Freshwater ecosystems are increasingly impacted by anthropogenic elevated levels of suspended sediment that may negatively affect aquatic organisms, including salamanders. Although increasing fine sediment in streams has been suggested as a reason for population declines, to date no study has empirically assessed the effect of suspended sediment on gilled larval Eastern Hellbenders (Cryptobranchus alleganiensis (Sonnini de Manoncourt and Latreille, 1801)), a critical life-history stage and a species of conservation concern. We used custom respirometers to elucidate effects of suspended sediments on larval Eastern Hellbender oxygen uptake in trials conducted in situ in Georgia (USA) streams. Mean oxygen uptake increased and was significantly higher in trials when larval salamanders were exposed to suspended sediment (mean = 5.06 mg O 2 /L for 800 mg/L of sediment treatment vs. 2.25 mg O 2 /L for 0.00 mg/L of sediment control). This may indicate elevated physiological stress in response to short-term exposure to suspended sediments. Qualitatively, individuals in both groups exhibited rocking behavior in response to low oxygen (hypoxia), albeit at different frequencies (sediment exposure = 7.6 rocks/min and control = 2.1 rocks/min). Larval salamanders may be able to temporarily compensate for low oxygen through increased rocking behavior when high suspended sediment loads are present, with future respirometry research needed.

hypoxia↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

A Guide to Energy Master Planning of High-Performance Districts and Communities

This guide was developed with partners throughout the United States to demonstrate how implementing district-scale high-performance strategies can be successful and scalable approaches to achieving deep energy savings that increase affordability, improve resilience, reduce emissions, and foster economic development. This document serves as a framework for districts, campuses, and communities, illustrating an iterative process of building support for, planning, and implementing high-performance districts by engaging stakeholders, setting aggressive energy goals, completing technical and financial planning, and implementing a high-performance energy master plan. The information in this guide is based on a 3-year U.S. Department of Energy Zero Energy District Accelerator and a range of real-world examples of emerging high-performance districts. It is particularly useful for architects, planners, engineers, local government agencies, and real estate developers in the early phases of planning a district with high-performance or other deep energy goals. For the purposes of this guide, a high-performance district is a multibuilding development that achieves aggressive energy and related goals such as zero energy, carbon neutrality, sustainability, ultra-efficiency, etc. High-performance districts optimize energy efficiency to reduce energy loads and use renewable energy resources to meet the remaining loads whenever possible. The Energy Independence and Security Act of 2007 defines a high-performance building as “a building that integrates and optimizes on a life cycle basis all major high-performance attributes, including energy conservation, environment, safety, security, durability, accessibility, cost-benefit, productivity, sustainability, functionality, and operational considerations.” High-performance districts are collections of such buildings that take advantage of the synergies available when energy consumption and production are considered at a district level rather than one building at a time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the effect of multiple load flexibility strategies on commercial building electricity demand and services via surrogate modeling

The expansion of commercial building demand response as a demand-side management resource for the electric grid necessitates new decision support resources for customers seeking to assess the benefit–risk tradeoffs of possible strategies for energy flexible building operations. To address this need, we, in this study, develop surrogate models that predict the impacts of several load flexibility strategies on commercial building electricity demand and indoor temperature, focusing on offices and retail buildings at multiple scales. The surrogate models are fit to a synthetic database generated via whole building simulations, which establish the relationships between the key operational features of a given strategy and potential changes in building demand and temperature across a variety of contexts. The surrogate models are translated to a Bayesian framework to allow straightforward communication of uncertainty and parameter updating given new evidence. We find strong predictive performance across the suite of models, underscoring the usefulness of the approach in guiding decisions about implementing load flexibility strategies under a particular set of operational and environmental conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Optimization Framework to Assess the Demand Response Capacity of a Water Distribution System

As large electricity consumers, water distribution system (WDS) pumping stations have the potential to become meaningful participants in demand response (DR) programs. The authors propose an optimization framework for assessing the DR capacity of a WDS and identifying the optimal bidding strategy for maximizing WDS revenue in the DR spot market. The proposed mixed integer linear programming (MILP) model overcomes computational constraints of previous DR optimization models by adopting a preprocessing procedure to minimize the number of binary variables and implementing a convex relaxation technique to linearize the hydraulic equations. The proposed MILP model also explicitly accounts for varying levels of risk tolerance of WDS operators by varying the recovery period over which pumping returns to business-as-usual operation. The optimization framework is implemented on a skeletonized 48-node WDS model that includes 7 pumps, 6 tanks, and 39 pipes. Using a simulated DR event and water consumption profile, the authors derive the optimal DR supply curves (i.e., compensation price versus load curtailment quantity) and revenue potential of the WDS under six scenarios for DR participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Implicit Solvers with Dynamic Mesh Adaptation for a Relativistic Drift-Kinetic Fokker–Planck–Boltzmann Model

In this work we consider a relativistic drift-kinetic model for runaway electrons along with a Fokker–Planck operator for small-angle Coulomb collisions, a radiation damping operator, and a secondary knock-on (Boltzmann) collision source. Here, we develop a new scalable fully implicit solver utilizing finite volume and conservative finite difference schemes and dynamic mesh adaptivity. A new data management framework in the PETSc library based on the p4est library is developed to enable simulations with dynamic adaptive mesh refinement (AMR), distributed memory parallelization, and dynamic load balancing of computational work. This framework and the runaway electron solver building on the framework are able to dynamically capture both bulk Maxwellian at the low-energy region and a runaway tail at the high-energy region. To effectively capture features via the AMR algorithm, a new AMR indicator prediction strategy is proposed that is performed alongside the implicit time evolution of the solution. This strategy is complemented by the introduction of computationally cheap feature-based AMR indicators that are analyzed theoretically. Numerical results quantify the advantages of the prediction strategy in better capturing features compared with nonpredictive strategies; and we demonstrate trade-offs regarding computational costs. The robustness with respect to model parameters, algorithmic scalability, and parallel scalability are demonstrated through several benchmark problems including manufactured solutions and solutions of different physics models. We focus on demonstrating the advantages of using implicit time stepping and AMR for runaway electron simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bounding Pressure and Flammability Evaluations of Aluminum-Clad Spent Nuclear Fuel Department of Energy Standard Canisters

This paper presents bounding pressure and flammability evaluations for DOE Standard Canister loaded with DOE-managed aluminum-clad spent nuclear fuel (ASNF). The objective of these evaluations is to gain confidence in the safety and feasibility of possible loading configurations for extended (>50 years) periods of dry storage, with particular focus on the dry storage canister pressures and potential for formation of a flammable atmosphere. The primary concern about the extended dry storage of ASNF is radiolytic gas generation. The aluminum cladding of these materials tends to corrode, and these corrosion products—typically aluminum oxides, such as boehmite, bayerite, or gibbsite—could carry water. This makes ASNF dry storage canisters difficult to dry. The gamma radiation field in dry storage environments could cause a radiolytic breakdown of residual water, forming chemical species such as molecular hydrogen (H2). The release of these species could increase the canister pressure and lead to the generation of a flammable canister atmosphere. The bounding evaluations presented within this study surmise conservative, but credible, conditions and processes. This includes the assumption of a full breakdown of a large quantity of free, physisorbed, and chemisorbed water (bound in a trihydrate, i.e., Al2O3 • 3H2O, layer). The considered dry storage configurations include a ~3 m (10 ft) long, ~46 cm (18 in) diameter (10 x 18) DOE Standard Canister loaded with 32 Advanced Test Reactor (ATR) ASNF elements, and a ~3 m (10 ft) long, ~61 cm (24 in) (10 x 24) diameter DOE Standard Canister loaded with 40 ATR ASNF elements. While the results of this study indicate the possibility of atmospheric hydrogen concentrations above the lower flammability limit, insufficient concentrations of oxygen will prevent the formation of flammable atmospheres. The maximum credible pressures remain well within the structural limits of the DOE Standard Canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗