Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Wilkinson Microwave Anisotropy Probe (WMAP) First Year Observations: TE Polarization

The Wilkinson Microwave Anisotropy Probe (WMAP) has mapped the full sky in Stokes I, Q, and U parameters at frequencies 23, 33, 41, 61, and 94 GHz. We detect correlations between the temperature and polarization maps significant at more than 10 standard deviations. The correlations are inconsistent with instrument noise and are significantly larger than the upper limits established for potential systematic errors. The correlations are present in all WAMP frequency bands with similar amplitude from 23 to 94 GHz, and are consistent with a superposition of a CMB signal with a weak foreground. The fitted CMB component is robust against different data combinations and fitting techniques. On small angular scales (theta less than 5 deg), the WMAP data show the temperature-polarization correlation expected from adiabatic perturbations in the temperature power spectrum. The data for l greater than 20 agree well with the signal predicted solely from the temperature power spectra, with no additional free parameters. We detect excess power on large angular scales (theta greater than 10 deg) compared to predictions based on the temperature power spectra alone. The excess power is well described by reionization at redshift 11 is less than z(sub r) is less than 30 at 95% confidence, depending on the ionization history. A model-independent fit to reionization optical depth yields results consistent with the best-fit ACDM model, with best fit value t = 0.17 +/- 0.04 at 68% confidence, including systematic and foreground uncertainties. This value is larger than expected given the detection of a Gunn-Peterson trough in the absorption spectra of distant quasars, and implies that the universe has a complex ionization history: WMAP has detected the signal from an early epoch of reionization.

Kogut, A.↗

A Measure from Line-of-Sight Magnetograms for Prediction of Coronal Mass Ejections

From a sample of 17 vector magnetograms of 12 bipolar active regions, we have recently found (1) that a measure of the overall nonpotentiality (the overall twist and shear in the magnetic field) of an active region is given by the strong-shear length L(sub SS), the length of the portion of the main neutral line on which the observed transverse fields is strong (greater than 150 G) and strongly sheared (shear angle greater than 45 deg), and (2) that L(sub SS) is well correlated with the CME productivity of the active regions during the +/- 2-day time window centered on the day of the magnetogram. In the present paper, from the same sample of 17 vector magnetograms, we show that there is a viable proxy for L(sub SS) that can be measured from a line-of-sight magnetogram. This proxy is the strong-gradient length L(sub SG), the length of the portion of the main neutral line on which the potential transverse field is strong (greater than 150 G) and the gradient of the line-of-sight field is sufficiently steep (greater than or approximately 50 G/Mm). In our sample of active regions, L(sub SG) is statistically significantly correlated with L(sub SS) (correlation confidence level greater than 95%), and L(sub SG) is as strongly correlated with active-region CME productivity as is L(sub SS)(correlation confidence level approximately 99.7%). Because L(sub SG) can be measured from line-of-sight magnetograms obtained from conventional magnetographs, such as the magnetograph mode of the Michelson Doppler Imager (MDI) on board the Solar and Heliospheric Observatory (SOHO), it is a dependable substitute for L(sub SS) for use in operational CME forecasting. In addition, via measurement of L(sub SG), the years-long, nearly continuous sequence of 1.5-hour-cadence full-disk line-of-sight magnetograms from MDI can be used to track the growth and decay of the large-scale nonpotentiality in active regions and to examine the role of this evolution in active-region CME productivity.

Falconer, D. A.↗

Real-Time Stability and Control Derivative Extraction From F-15 Flight Data

A real-time, frequency-domain, equation-error parameter identification (PID) technique was used to estimate stability and control derivatives from flight data. This technique is being studied to support adaptive control system concepts currently being developed by NASA (National Aeronautics and Space Administration), academia, and industry. This report describes the basic real-time algorithm used for this study and implementation issues for onboard usage as part of an indirect-adaptive control system. A confidence measures system for automated evaluation of PID results is discussed. Results calculated using flight data from a modified F-15 aircraft are presented. Test maneuvers included pilot input doublets and automated inputs at several flight conditions. Estimated derivatives are compared to aerodynamic model predictions. Data indicate that the real-time PID used for this study performs well enough to be used for onboard parameter estimation. For suitable test inputs, the parameter estimates converged rapidly to sufficient levels of accuracy. The devised confidence measures used were moderately successful.

Smith, Mark S.↗

Remote Sensing of Liquid Water and Ice Cloud Optical Thickness and Effective Radius in the Arctic: Application of Airborne Multispectral MAS Data

A multispectral scanning spectrometer was used to obtain measurements of the reflection function and brightness temperature of clouds, sea ice, snow, and tundra surfaces at 50 discrete wavelengths between 0.47 and 14.0 microns. These observations were obtained from the NASA ER-2 aircraft as part of the FIRE Arctic Clouds Experiment, conducted over a 1600 x 500 km region of the north slope of Alaska and surrounding Beaufort and Chukchi Seas between 18 May and 6 June 1998. Multispectral images of the reflection function and brightness temperature in 11 distinct bands of the MODIS Airborne Simulator (MAS) were used to derive a confidence in clear sky (or alternatively the probability of cloud), shadow, and heavy aerosol over five different ecosystems. Based on the results of individual tests run as part of the cloud mask, an algorithm was developed to estimate the phase of the clouds (water, ice, or undetermined phase). Finally, the cloud optical thickness and effective radius were derived for both water and ice clouds that were detected during one flight line on 4 June. This analysis shows that the cloud mask developed for operational use on MODIS, and tested using MAS data in Alaska, is quite capable of distinguishing clouds from bright sea ice surfaces during daytime conditions in the high Arctic. Results of individual tests, however, make it difficult to distinguish ice clouds over snow and sea ice surfaces, so additional tests were added to enhance the confidence in the thermodynamic phase of clouds over the Beaufort Sea. The cloud optical thickness and effective radius retrievals used 3 distinct bands of the MAS, with the newly developed 1.62 and 2.13 micron bands being used quite successfully over snow and sea ice surfaces. These results are contrasted with a MODIS-based algorithm that relies on spectral reflectance at 0.87 and 2.13 micron.

King, Michael D.↗

Statistical Sampling of Tide Heights Study

The goal of the study was to determine if it was possible to reduce the cost of verifying computational models of tidal waves and currents. Statistical techniques were used to determine the least number of samples required, in a given situation, to remain statistically significant, and thereby reduce overall project costs. Commercial, academic, and Federal agencies could benefit by applying these techniques, without the need to 'touch' every item in the population. For example, the requirement of this project was to measure the heights and times of high and low tides at 8,000 locations for verification of computational models of tidal waves and currents. The application of the statistical techniques began with observations to determine the correctness of submitted measurement data, followed by some assumptions based on the observations. Among the assumptions were that the data were representative of data-collection techniques used at the measurement locations, that time measurements could be ignored (that is, height measurements alone would suffice), and that the height measurements were from a statistically normal distribution. Sample means and standard deviations were determined for all locations. Interval limits were determined for confidence levels of 95, 98, and 99 percent. It was found that the numbers of measurement locations needed to attain these confidence levels were 55, 78, and 96, respectively.

Source record↗

Uniting Space, Ground and Underwater Measurements for Improved Estimates of Rain Rate

Global precipitation is monitored from a variety of platforms including space-borne, ground- and ocean-based platforms. Intercomparisons of these observations are crucial to validating the measurements and providing confidence for each measurement technique. Probability distribution functions of rain rates are used to compare satellite and ground-based radar observations. A preferred adjustment technique for improving rain rate distribution estimates is identified using measurements from ground-based radar and radar and rain gauges within the coverage area of the radar. The underwater measurement of rainfall shows similarities to radar measurements, but with intermediate spatial resolution and high temporal resolution. Reconciling these different measurement techniques provides understanding and confidence for all of the methods.

Amitai, E.↗

Prediction of Active-Region CME Productivity from Magnetograms

We report results of an expanded evaluation of whole-active-region magnetic measures as predictors of active-region coronal mass ejection (CME) productivity. Previously, in a sample of 17 vector magnetograms of 12 bipolar active regions observed by the Marshall Space Flight Center (MSFC) vector magnetograph, from each magnetogram we extracted a measure of the size of the active region (the active region s total magnetic flux a) and four measures of the nonpotentiality of the active region: the strong-shear length L(sub SS), the strong-gradient length L(sub SG), the net vertical electric current I(sub N), and the net-current magnetic twist parameter alpha (sub IN). This sample size allowed us to show that each of the four nonpotentiality measures was statistically significantly correlated with active-region CME productivity in time windows of a few days centered on the day of the magnetogram. We have now added a fifth measure of active-region nonpotentiality (the best-constant-alpha magnetic twist parameter (alpha sub BC)), and have expanded the sample to 36 MSFC vector magnetograms of 31 bipolar active regions. This larger sample allows us to demonstrate statistically significant correlations of each of the five nonpotentiality measures with future CME productivity, in time windows of a few days starting from the day of the magnetogram. The two magnetic twist parameters (alpha (sub 1N) and alpha (sub BC)) are normalized measures of an active region s nonpotentially in that they do not depend directly on the size of the active region, while the other three nonpotentiality measures (L(sub SS), L(sub SG), and I(sub N)) are non-normalized measures in that they do depend directly on active-region size. We find (1) Each of the five nonpotentiality measures is statistically significantly correlated (correlation confidence level greater than 95%) with future CME productivity and has a CME prediction success rate of approximately 80%. (2) None of the nonpotentiality measures is a significantly better CME predictor than the others. (3) The active-region phi shows some correlation with CME productivity, but well below a statistically significant level (correlation confidence level less than approximately 80%; CME prediction success rate less than approximately 65%). (4) In addition to depending on magnetic twist, CME productivity appears to have some direct dependence on active-region size (rather than only an indirect dependence through a correlation of magnetic twist with active-region size), but it will take a still larger sample of active regions (50 or more) to certify this. (5) Of the five nonpotentiality measures, L(sub SG) appears to be the best for operational CME forecasting because it is as good or better a CME predictor than the others and it alone does not require a vector magnetogram; L(sub SG) can be measured from a line-of-sight magnetogram such as from the Michelson Doppler Imager (MDI) on the Solar and Heliospheric Observatory (SOHO).

Falconer, D. A.↗

A Measure from Line-of-Sight Magnetograms for Prediction of Coronal Mass Ejections

From a sample of 17 vector magnetograms of 12 bipolar active regions we have recently found (1) that a measure of the overall nonpotentiality (the overall twist and shear in the magnetic field) of an active region is given by the strong shear length Lss, the length of the portion of the main neutral line on which the observed transverse fields is strong (greater than 150 Guass (G)) and strongly sheared (shear angle greater than 45 degrees), and (2) that L(sub ss) is well correlated with the coronal mass ejection (CME) productivity of the active regions during the plus or minus 2-day time window centered on the day of the magnetogram. In the present paper, from the same sample of 17 vector magnetograms, we show that there is a viable proxy for L(sub ss) that can be measured from a line-of-sight magnetogram. This proxy is the strong gradient length L(sub SG), the length of the portion of the main neutral line on which the potential transverse field is strong (greater than 150 G), and the gradient of the line-of-sight field is sufficiently steep (greater than approximately 50 G/Mm). In our sample of active regions, L(sub SG) is statistically significantly correlated with Lss (correlation confidence level greater than 95%), and L(sub SG) is as strongly correlated with active region CME productivity as is L(sub SS) (correlation confidence level approximately 99.7%). Because L(sub SG) can be measured from line-of-sight magnetograms obtained from conventional magnetographs, such as the magnetograph mode of the Michelson Doppler Imager (MDI) on board the Solar and Heliospheric Observatory, it is a dependable substitute for L(sub SS) for use in operational CME forecasting. In addition, via measurement of L(sub SG), the years-long, nearly continuous sequence of 1.5-hour cadence full disk line-of-sight magnetograms from MDI can be used to track the growth and decay of the large-scale nonpotentiality in active regions and to examine the role of this evolution in active region CME productivity.

Falconer, D. A.↗

Forecasting Coronal Mass Ejections from Magnetograms

We report further results from our ongoing assessment of magnetogram-based measures of active-region nonpotentiality (magnetic shear and twist) and size as predictors of coronal mass ejections (CMEs). From a set of 36 vector magnetograms of bipolar active regions (Falconer, Moore, & Gary 2004, ApJ, submitted), we have found that (1) each of our 5 measures of active-region nonpotentiality has a 75-80% success rate in predicting whether an active region will produce a CME within 2 days after the magnetogram, (2) the correlation of each of these measures with CME production in this window is statistically significant (confidence level greater than 95%), (3) our measure of active-region size has a 65% success rate in predicting CMEs in this window, but (4) the correlation between active-region size and CME productivity is not statistically significant (confidence level approximately 80%). As part of the work under our pending 2003 LWS TR&T proposal, we will double our sample to approximately 70 active regions in order to demonstrate a statistically significant correlation between active-region size and CME productivity, and to determine whether this correlation is a byproduct of any Sun-produced correlation between magnetic twist and size of active regions. Since the 2002 LWS Science Workshop, we have found a measure of active-region nonpotentiality (the length of strong-gradient neutral line) that can be measured from a line-of-sight magnetogram, and we have generalized this measure and the corresponding measure from a vector magnetogram (the length of strong-shear neutral line) so that they can be applied to multiple-bipole complex active regions as well as to bipolar active regions. Preliminary results will be presented from application of these two generalized measures to our sample of bipolar active regions and to a new sample of multiple-bipole active regions.

Falconer, D. A.↗

WMAP Detection of Early Reionization

The Wilkinson Microwave Anisotropy Probe (WMAP) has mapped the full sky in Stokes I, Q, and U parameters at frequencies 23, 33, 41, 61, and 94 GHz. We detect correlations between the temperature and polarization maps significant at more than 10 standard deviations. The correlations are inconsistent with instrument noise and are significantly larger than the upper limits established for potential systenatic errors. The correlations are present in all WMAP frequency bands with similar amplitude from 23 to 94 GHz, and are consistent with a superposition of a CMB signal with a weak foreground. The fitted CMB component is robust against different data combinations and fitting techniques. On small angular scales the WMAP data show the temperature-polarization correlation expected from adiabatic density perturbations. The data for $\ell > 20$ agree well with the signal predicted solely from the temperature power spectra, with no additional free parameters. The existence of correlations on super-horizon scales provides significant support for inflationary cosmologies. We detect excess power on large angular scales compared to predictions based on the temperature power spectra alone. The excess power is well described by reionization at redshift $11 < z < 30$ at 95\% confidence. A model-independent fit to reionization optical depth yields results consistent with the best-fit $\Lambda$CDM model, with best fit value $\tau = 0.17 \pm 0.04$ at 68\% confidence, including systematic and foreground uncertainties. This value is larger than expected given the detection of a Gunn-Peterson trough in the absorption spectra of distant quasars, and implies that the universe has a complex ionization history. I will discuss the WMAP data and its implications for reionization in the early universe.

Kogut, A.↗

WMAP Detection of Early Reionization

The Wilkinson Microwave Anisotropy Probe (WMAP) has mapped the full sky in Stokes I, Q, and U parameters at frequencies 23, 33, 41, 61, and 94 GHz. We detect correlations between the temperature and polarization maps significant at more than 10 standard deviations. The correlations are inconsistent with instrument noise and are significantly larger than the upper limits established for potential systematic errors. The correlations are present in all WMAP frequency bands with similar amplitude from 23 to 94 GHz, and are consistent with a superposition of a CMB signal with a weak foreground. The fitted CMB component is robust against different data combinations and fitting techniques. On small angular scales the WMAP data show the temperature-polarization correlation expected from adiabatic density perturbations. The data for $\ell > 20$ agree well with the signal predicted solely from the temperature power spectra, with no additional free parameters. The existence of correlations on super-horizon scales provides significant support for inflationary cosmologies. We detect excess power on large angular scales compared to predictions based on the temperature power spectra alone. The excess power is well described by reionization at redshift $11 < z < 30$ at 95\% confidence. A model-independent fit to reionization optical depth yields results consistent with the best-fit $\Lambda$CDM model, with best fit value $\tau = 0.17 \pm 0.04$ at 68\% confidence, including systematic and foreground uncertainties. This trough in the absorption spectra of distant quasars, and implies that the universe has a complex ionization history. I will discuss the WMAP data and its implications for reionization in the early universe.

Kogut, A.↗

PEM-INST-001: Instructions for Plastic Encapsulated Microcircuit (PEM) Selection, Screening, and Qualification

Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.

Teverovsky, Alexander↗

Initial Validation of NDVI time seriesfrom AVHRR, VEGETATION, and MODIS

The paper will address Theme 7: Multi-sensor opportunities for VEGETATION. We present analysis of a long-term vegetation record derived from three moderate resolution sensors: AVHRR, VEGETATION, and MODIS. While empirically based manipulation can ensure agreement between the three data sets, there is a need to validate the series. This paper uses atmospherically corrected ETM+ data available over the EOS Land Validation Core Sites as an independent data set with which to compare the time series. We use ETM+ data from 15 globally distributed sites, 7 of which contain repeat coverage in time. These high-resolution data are compared to the values of each sensor by spatially aggregating the ETM+ to each specific sensors' spatial coverage. The aggregated ETM+ value provides a point estimate for a specific site on a specific date. The standard deviation of that point estimate is used to construct a confidence interval for that point estimate. The values from each moderate resolution sensor are then evaluated with respect to that confident interval. Result show that AVHRR, VEGETATION, and MODIS data can be combined to assess temporal uncertainties and address data continuity issues and that the atmospherically corrected ETM+ data provide an independent source with which to compare that record. The final product is a consistent time series climate record that links historical observations to current and future measurements.

Morisette, Jeffrey T.↗

Evaluation of a CFD Method for Aerodynamic Database Development using the Hyper-X Stack Configuration

A computational fluid dynamic (CFD) study is performed on the Hyper-X (X-43A) Launch Vehicle stack configuration in support of the aerodynamic database generation in the transonic to hypersonic flow regime. The main aim of the study is the evaluation of a CFD method that can be used to support aerodynamic database development for similar future configurations. The CFD method uses the NASA Langley Research Center developed TetrUSS software, which is based on tetrahedral, unstructured grids. The Navier-Stokes computational method is first evaluated against a set of wind tunnel test data to gain confidence in the code s application to hypersonic Mach number flows. The evaluation includes comparison of the longitudinal stability derivatives on the complete stack configuration (which includes the X-43A/Hyper-X Research Vehicle, the launch vehicle and an adapter connecting the two), detailed surface pressure distributions at selected locations on the stack body and component (rudder, elevons) forces and moments. The CFD method is further used to predict the stack aerodynamic performance at flow conditions where no experimental data is available as well as for component loads for mechanical design and aero-elastic analyses. An excellent match between the computed and the test data over a range of flow conditions provides a computational tool that may be used for future similar hypersonic configurations with confidence.

Parikh, Paresh↗

Application of Laser Based Ultrasound for NDE of Damage in Thick Stitched Composites

As design engineers implement new composite systems such as thick, load bearing composite structures, they must have certifiable confidence in structure s durability and worthiness. This confidence builds from understanding the structural response and failure characteristics of simple components loaded in testing machines to tests on full scale sections. Nondestructive evaluation is an important element which can provide quantitative information on the damage initiation, propagation, and final failure modes for the composite structural components. Although ultrasound is generally accepted as a test method, the use of conventional ultrasound for in-situ monitoring of damage during tests of large structures is not practical. The use of lasers to both generate and detect ultrasound extends the application of ultrasound to in- situ sensing of damage in a deformed structure remotely and in a non-contact manner. The goal of the present research is to utilize this technology to monitor damage progression during testing. The present paper describes the application of laser based ultrasound to quantify damage in thick stitched composite structural elements to demonstrate the method. This method involves using a Q-switched laser to generate a rapid, local linear thermal strain on the surface of the structure. This local strain causes the generation of ultrasonic waves into the material. A second laser used with a Fabry-Perot interferometer detects the surface deflections. The use of fiber optics provides for eye safety and a convenient method of delivering the laser over long distances to the specimens. The material for these structural elements is composed of several stacks of composite material assembled together by stitching through the laminate thickness that ranging from 0.5 to 0.8 inches. The specimens used for these nondestructive evaluation studies had either impact damage or skin/stiffener interlaminar failure. Although little or no visible surface damage existed, internal damage was detected by laser based ultrasound.

Anastasi, Robert F.↗

Allowables for Structural Composites

In order to obtain the most benefit from building a structure with composite laminates, the strength of the laminate must be known. Based on the "weakest link" theory, the lower strength numbers obtained from testing are the ones to be used for design and analysis. The strength value to be used is determined by a statistical analysis of the test data, and is known as an allowable. MIL-HDBK- 17 outlines procedures to follow for determining these allowables. There are two types of statistically determined allowables, A- Basis and B-Basis. A-Basis is defined as a strength value at which only 1 in 100 specimens will fail with a 95% confidence level. B-Basis is a strength value at which only 10 in 100 specimens will fail with a 95% confidence level. As more specimens are tested a higher value of strength can be used as a valid allowable. Composites are highly process dependent and show much strength variation with environment, so it is critical to test materials and environments that are representative of hardware. Either using data obtained from a previous test series, or extrapolation to a certain temperature is highly discouraged.

Nettles, Alan T.↗

Evaluation of dual-tip micromanometers during 21-day implantation in goats

Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

Non-NASA Center↗

Quantitative assessment of the cataractogenic potential of very low doses of neutrons

We report on the prevalence and relative biological effectiveness (RBE) for various stages of lens opacification in rats induced by very low doses (2 to 250 mGy) of medium-energy (440 keV) neutrons, compared to those for X rays. Neutron doses were delivered either in a single fraction or in four separate fractions and the irradiated animals were followed for over 100 weeks. At the highest observed dose (250 mGy) and at early observation times, there was evidence of an inverse dose-rate effect; i.e., a fractionated exposure was more potent than a single exposure. Neutron RBEs relative to X rays were estimated using a non-parametric technique. The results were only weakly dependent on time postirradiation. At 30 weeks, for example, 80% confidence intervals for the RBE of acutely delivered neutrons relative to X rays were 8-16 at 250 mGy, 10-20 at 50 mGy, 50-100 at 10 mGy and 250-500 at 2 mGy. The results are consistent with the estimated neutron RBEs in Japanese A-bomb survivors, though broad confidence bounds are present in the Japanese results. Our findings are also consistent with data reported earlier for cataractogenesis induced by heavy ions in rats, mice, and rabbits. We conclude from these results that, at very low doses (<10 mGy), the RBE for neutron-induced cataractogenesis is considerably larger than the RBE of 20 commonly used, and use of a significantly larger value for calculating equivalent dose would be prudent.

NASA Discipline Radiation Health↗