Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Accurate spectroscopic characterization of oxirane: A valuable route to its identification in Titan's atmosphere and the assignment of unidentified infrared bands

In an effort to provide an accurate spectroscopic characterization of oxirane, state-of-the-art computational methods and approaches have been employed to determine highly accurate fundamental vibrational frequencies and rotational parameters. Available experimental data were used to assess the reliability of our computations, and an accuracy on average of 10 cm{sup –1} for fundamental transitions as well as overtones and combination bands has been pointed out. Moving to rotational spectroscopy, relative discrepancies of 0.1%, 2%-3%, and 3%-4% were observed for rotational, quartic, and sextic centrifugal-distortion constants, respectively. We are therefore confident that the highly accurate spectroscopic data provided herein can be useful for identification of oxirane in Titan's atmosphere and the assignment of unidentified infrared bands. Since oxirane was already observed in the interstellar medium and some astronomical objects are characterized by very high D/H ratios, we also considered the accurate determination of the spectroscopic parameters for the mono-deuterated species, oxirane-d1. For the latter, an empirical scaling procedure allowed us to improve our computed data and to provide predictions for rotational transitions with a relative accuracy of about 0.02% (i.e., an uncertainty of about 40 MHz for a transition lying at 200 GHz).

74 ATOMIC AND MOLECULAR PHYSICS↗

Chaos and turbulent nucleosynthesis prior to a supernova explosion

Three-dimensional (3D), time dependent numerical simulations of flow of matter in stars, now have sufficient resolution to be fully turbulent. The late stages of the evolution of massive stars, leading up to core collapse to a neutron star (or black hole), and often to supernova explosion and nucleosynthesis, are strongly convective because of vigorous neutrino cooling and nuclear heating. Unlike models based on current stellar evolutionary practice, these simulations show a chaotic dynamics characteristic of highly turbulent flow. Theoretical analysis of this flow, both in the Reynolds-averaged Navier-Stokes (RANS) framework and by simple dynamic models, show an encouraging consistency with the numerical results. It may now be possible to develop physically realistic and robust procedures for convection and mixing which (unlike 3D numerical simulation) may be applied throughout the long life times of stars. In addition, a new picture of the presupernova stages is emerging which is more dynamic and interesting (i.e., predictive of new and newly observed phenomena) than our previous one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Virtual/Augmented Reality (VR/AR):Tools for Nuclear Training, Operations and Design

Introduction: Problems: Mistakes in the field due to a lack of information (Ex: Pump repair failure rate 50%); Avoidable exposure due to multiple employees for procedure adherence and monitoring; Debates over 2D drawings can be more easily resolved. Purpose: Training: Employees can be trained more effectively. Operating: Operations can be carried out more efficiently with fewer workers required with AR. Design Review: Pull the designers and designs into VR. Design: VR: Unreal Engine, Unity, Custom. AR: HoloLens: Unity, Custom - DirectX 12.

42 ENGINEERING↗

The coyote universe extended: Precision emulation of the matter power spectrum

Modern sky surveys are returning precision measurements of cosmological statistics such as weak lensing shear correlations, the distribution of galaxies, and cluster abundance. To fully exploit these observations, theorists must provide predictions that are at least as accurate as the measurements, as well as robust estimates of systematic errors that are inherent to the modeling process. In the nonlinear regime of structure formation, this challenge can only be overcome by developing a large-scale, multi-physics simulation capability covering a range of cosmological models and astrophysical processes. As a first step to achieving this goal, we have recently developed a prediction scheme for the matter power spectrum (a so-called emulator), accurate at the 1% level out to k ∼ 1 Mpc{sup –1} and z = 1 for wCDM cosmologies based on a set of high-accuracy N-body simulations. It is highly desirable to increase the range in both redshift and wavenumber and to extend the reach in cosmological parameter space. To make progress in this direction, while minimizing computational cost, we present a strategy that maximally reuses the original simulations. We demonstrate improvement over the original spatial dynamic range by an order of magnitude, reaching k ∼ 10 h Mpc{sup –1}, a four-fold increase in redshift coverage, to z = 4, and now include the Hubble parameter as a new independent variable. To further the range in k and z, a new set of nested simulations run at modest cost is added to the original set. The extension in h is performed by including perturbation theory results within a multi-scale procedure for building the emulator. This economical methodology still gives excellent error control, ∼5% near the edges of the domain of applicability of the emulator. A public domain code for the new emulator is released as part of the work presented in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-07: Real-Time Image Guided Radiation Therapy for Heterotopic Ossification in Patients After Hip Replacement

Purpose: To demonstrate the feasibility of using CBCT in a real-time image guided radiation therapy (IGRT) for single fraction heterotopic ossification (HO) in patients after hip replacement. In this real-time procedure, all steps, from simulation, imaging, planning to treatment delivery, are performed at the treatment unit in one appointment time slot. This work promotes real-time treatment to create a paradigm shift in the single fraction radiation therapy. Methods: An integrated real-time IGRT for HO was developed and tested for radiation treatment of heterotopic ossification for patient after hip replacement. After CBCT images are acquired at the linac, and sent to the treatment planning system, the physician determines the field and/or draws a block. Subsequently, a simple 2D AP/PA plan with prescription of 700 cGy is created on-the-fly for physician to review. Once the physician approves the plan, the patient is treated on the same simulation position. This real-time treatment requires the team of attending physician, physicist, therapists, and dosimetrist to work in harmony to achieve all the steps in a timely manner. Results: Ten patients have been treated with this real-time treatment, having the same beams arrangement treatment plan and prescription as our clinically regular CT-based 2D plans. The average time for these procedures are 52.9 ±10.7 minutes from the time patient entered the treatment room until s/he exited, and 37.7 ±8.6 minutes from starting CBCT until last beam delivered. Conclusion: The real-time IGRT for HO treatment has been tested and implemented to be a clinically accepted procedure. This one-time appointment greatly enhances the waiting time, especially when patients in high level of pain, and provides a convenient approach for the whole clinical staff. Other disease sites will be also tested with this new technology.

60 APPLIED LIFE SCIENCES↗

JET MIXING ANALYSIS FOR SRS HIGH-LEVEL WASTE RECOVERY

The process of recovering the waste in storage tanks at the Savannah River Site (SRS) typically requires mixing the contents of the tank to ensure uniformity of the discharge stream. Mixing is accomplished with one to four slurry pumps located within the tank liquid. The slurry pump may be fixed in position or they may rotate depending on the specific mixing requirements. The high-level waste in Tank 48 contains insoluble solids in the form of potassium tetraphenyl borate compounds (KTPB), monosodium titanate (MST), and sludge. Tank 48 is equipped with 4 slurry pumps, which are intended to suspend the insoluble solids prior to transfer of the waste to the Fluidized Bed Steam Reformer (FBSR) process. The FBSR process is being designed for a normal feed of 3.05 wt% insoluble solids. A chemical characterization study has shown the insoluble solids concentration is approximately 3.05 wt% when well-mixed. The project is requesting a Computational Fluid Dynamics (CFD) mixing study from SRNL to determine the solids behavior with 2, 3, and 4 slurry pumps in operation and an estimate of the insoluble solids concentration at the suction of the transfer pump to the FBSR process. The impact of cooling coils is not considered in the current work. The work consists of two principal objectives by taking a CFD approach: (1) To estimate insoluble solids concentration transferred from Tank 48 to the Waste Feed Tank in the FBSR process and (2) To assess the impact of different combinations of four slurry pumps on insoluble solids suspension and mixing in Tank 48. For this work, several different combinations of a maximum of four pumps are considered to determine the resulting flow patterns and local flow velocities which are thought to be associated with sludge particle mixing. Two different elevations of pump nozzles are used for an assessment of the flow patterns on the tank mixing. Pump design and operating parameters used for the analysis are summarized in Table 1. The baseline pump orientations are chosen by the previous work [Lee et. al, 2008] and the initial engineering judgement for the conservative flow estimate since the modeling results for the other pump orientations are compared with the baseline results. As shown in Table 1, the present study assumes that each slurry pump has 900 gpm flowrate for the tank mixing analysis, although the Standard Operating Procedure for Tank 48 currently limits the actual pump speed and flowrate to a value less than 900 gpm for a 29 inch liquid level. Table 2 shows material properties and weight distributions for the solids to be modeled for the mixing analysis in Tank 48.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Models and Characterization of Piezoelectric Ceramics

Selected literature on the use of linearized constitutive equations and complex piezoelectric coefficients to develop models and characterize materials is presented in brief. One-dimensional models of simple piezoelectric ceramic components are derived using linearized constitutive equations and other fundamental relations to illustrate the procedure used to develop multi-dimensional models. Then, the procedure for building models of multi-layer devices using models of components is illustrated. Models are also used to characterize materials. A method to determine the errors when the ANSI/IEEE Standard method is used to determine real piezoelectric coefficients and methods to characterize non-Standard shapes often used in devices are also presented.

36 MATERIALS SCIENCE↗

Coagulation kinetics beyond mean field theory using an optimised Poisson representation

Binary particle coagulation can be modelled as the repeated random process of the combination of two particles to form a third. The kinetics may be represented by population rate equations based on a mean field assumption, according to which the rate of aggregation is taken to be proportional to the product of the mean populations of the two participants, but this can be a poor approximation when the mean populations are small. However, using the Poisson representation, it is possible to derive a set of rate equations that go beyond mean field theory, describing pseudo-populations that are continuous, noisy, and complex, but where averaging over the noise and initial conditions gives the mean of the physical population. Such an approach is explored for the simple case of a size-independent rate of coagulation between particles. Analytical results are compared with numerical computations and with results derived by other means. In the numerical work, we encounter instabilities that can be eliminated using a suitable “gauge” transformation of the problem [P. D. Drummond, Eur. Phys. J. B 38, 617 (2004)] which we show to be equivalent to the application of the Cameron-Martin-Girsanov formula describing a shift in a probability measure. The cost of such a procedure is to introduce additional statistical noise into the numerical results, but we identify an optimised gauge transformation where this difficulty is minimal for the main properties of interest. For more complicated systems, such an approach is likely to be computationally cheaper than Monte Carlo simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New scheme for the running coupling constant in gauge theories using Wilson loops

We propose a new renormalization scheme of the running coupling constant in general gauge theories using the Wilson loops. The renormalized coupling constant is obtained from the Creutz ratio in lattice simulations and the corresponding perturbative coefficient at the leading order. The latter can be calculated by adopting the zeta-function resummation techniques. We perform a benchmark test of our scheme in quenched QCD with the plaquette gauge action. The running of the coupling constant is determined by applying the step-scaling procedure. Using several methods to improve the statistical accuracy, we show that the running coupling constant can be determined in a wide range of energy scales with a relatively small number of gauge configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams

An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new k{sub Q} data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accuracy and consistency of the protocol's implementation. The components of the uncertainty budget in determining absorbed dose to water at the reference point are introduced and the magnitude of each component discussed. Finally, the consistency of experimental determination of N{sub D,w} coefficients is discussed. It is expected that the implementation of this addendum will be straightforward, assuming that the user is already familiar with TG-51. The changes introduced by this report are generally minor, although new recommendations could result in procedural changes for individual users. It is expected that the effort on the medical physicist's part to implement this addendum will not be significant and could be done as part of the annual linac calibration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation for {sup 233}U-Fueled Systems in KENO V.a in SCALE 6.2

Validation of the KENO V.a Monte Carlo code has been performed in recent years using benchmark experiments contained in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The models used in these recent validation efforts have been drawn from the Verified, Archived Library of Inputs and Data (VALID). Models must be generated and reviewed by qualified individuals to be added to the VALID library, which leads to high confidence in the models and reduces the probability that apparent validation issues are a result of modeling errors. The contents of the VALID library are somewhat limited because of the effort involved in generating and reviewing models, so no {sup 233}U-fueled experiments are included in VALID. A large number of models of {sup 233}U experiments have been modeled in the past in support of the criticality safety of {sup 233}U in storage at Oak Ridge National Laboratory (ORNL). In June, 2016, two midshipmen from the United States Naval Academy were assigned to ORNL, and they reviewed and updated these models for execution in SCALE 6.2. The validation of {sup 233}U is of interest because some discrepancies in SCALE results were identified by a beta tester at the Nuclear Energy Agency modeling these systems. These discrepancies were related to a data thinning procedure in the continuous-energy nuclear data process, and had been resolved prior to the release of SCALE 6.2. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

C-Arm Computed Tomography Compared With Positron Emission Tomography/Computed Tomography for Treatment Planning Before Radioembolization

The purpose of this study was to determine whether rotational C-arm computed tomography (CT) allows visualization of liver metastases and adds relevant information for radioembolization (RE) treatment planning. Technetium angiography, together with C-arm CT, was performed in 47 patients to determine the feasibility for RE. C-arm CT images were compared with positron emission tomography (PET)/CT images for the detection of liver tumors. The images were also rated according one of the following three categories: (1) images that provide no additional information compared with DSA alone; (2) images that do provide additional information compared with DSA; and (2) images that had an impact on eligibility determination for and planning of the RE procedure. In all patients, 283 FDG-positive liver lesions were detected by PET. In venous contrast-phase CT, 221 (78.1%) and 15 (5.3%) of these lesions were either hypodense or hyperdense, respectively. In C-arm CT, 103 (36.4%) liver lesions were not detectable because they were outside of either the field of view or the contrast-enhanced liver segment. Another 25 (8.8%) and 98 (34.6%) of the liver lesions were either hyperdense or presented primarily as hypodense lesions with a rim enhancement, respectively. With PET/CT as the standard of reference, venous CT and C-arm CT failed to detect 47 (16.6%) and 57 (20.1%) of all liver lesions, respectively. For RE planning, C-arm CT provided no further information, provide some additional information, or had an impact on the procedure in 20 (42.5%), 15 (31.9%) and 12 (25.6%) of patients, respectively. We conclude that C-arm CT may add decisive information in patients scheduled for RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of current waveform tailoring for magnetically driven isentropic compression experiments

The Thor pulsed power generator is being developed at Sandia National Laboratories. The design consists of up to 288 decoupled and transit time isolated capacitor-switch units, called “bricks,” that can be individually triggered to achieve a high degree of pulse tailoring for magnetically driven isentropic compression experiments (ICE) [D. B. Reisman et al., Phys. Rev. Spec. Top.–Accel. Beams 18, 090401 (2015)]. The connecting transmission lines are impedance matched to the bricks, allowing the capacitor energy to be efficiently delivered to an ICE strip-line load with peak pressures of over 100 GPa. Thor will drive experiments to explore equation of state, material strength, and phase transition properties of a wide variety of materials. We present an optimization process for producing tailored current pulses, a requirement for many material studies, on the Thor generator. This technique, which is unique to the novel “current-adder” architecture used by Thor, entirely avoids the iterative use of complex circuit models to converge to the desired electrical pulse. We begin with magnetohydrodynamic simulations for a given material to determine its time dependent pressure and thus the desired strip-line load current and voltage. Because the bricks are connected to a central power flow section through transit-time isolated coaxial cables of constant impedance, the brick forward-going pulses are independent of each other. We observe that the desired equivalent forward-going current driving the pulse must be equal to the sum of the individual brick forward-going currents. We find a set of optimal brick delay times by requiring that the L{sub 2} norm of the difference between the brick-sum current and the desired forward-going current be a minimum. We describe the optimization procedure for the Thor design and show results for various materials of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Centre Experience with Percutaneous Cryoablation of Breast Cancer in 23 Consecutive Non-surgical Patients

AimTo present our single-centre prospective experience on the use of cryoablation (CA) applied to treat primary breast cancer (BC) in a cohort of patients unsuitable for surgical treatment.Materials and MethodsTwenty-three consecutive post-menopausal female patients (median age 85 years; range 56–96) underwent percutaneous CA of unifocal, biopsy-proven BC, under ultrasound/computed tomography (US/CT) guidance. Clinical and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) follow-ups were systematically scheduled at 3, 12, 18 and 24 months. Local tumour control was assessed by comparing baseline and follow-up DCE-MRI.ResultsTwenty-three BC (median size 14 mm) were treated under local anaesthesia (78.3 %) or local anaesthesia and conscious sedation (21.7 %). Median number of cryo-probes applied per session was 2.0. A “dual-freezing” protocol was applied for the first ten patients and a more aggressive “triple-freezing” protocol for the remaining 13. Median follow-up was 14.6 months. Five patients recurred during follow-up and two were successfully re-treated with CA. Five patients presented immediate CA-related complications: four hematomas evolved uneventfully at 3-month follow-up and one skin burn resulted in skin inflammation and skin retraction at 3 and 12 months, respectively.ConclusionsPercutaneous CA is safe and well tolerated for non-resected elderly BC patients. Procedures can be proposed under local anaesthesia only. Given the insulation properties of the breast gland, aggressive CA protocols are required. Prospective studies are needed to better understand the potential role of CA in the local treatment of early BC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Thermal Ablation with Ultrasound Guidance. Fusion Imaging Guidance to Improve Conspicuity of Liver Metastasis

PurposeTo assess whether fusion imaging-guided percutaneous microwave ablation (MWA) can improve visibility and targeting of liver metastasis that were deemed inconspicuous on ultrasound (US).Materials and MethodsMWA of liver metastasis not judged conspicuous enough on US was performed under CT/US fusion imaging guidance. The conspicuity before and after the fusion imaging was graded on a five-point scale, and significance was assessed by Wilcoxon test. Technical success, procedure time, and procedure-related complications were evaluated.ResultsA total of 35 patients with 40 liver metastases (mean size 1.3 ± 0.4 cm) were enrolled. Image fusion improved conspicuity sufficiently to allow fusion-targeted MWA in 33 patients. The time required for image fusion processing and tumors’ identification averaged 10 ± 2.1 min (range 5–14). Initial conspicuity on US by inclusion criteria was 1.2 ± 0.4 (range 0–2), while conspicuity after localization on fusion imaging was 3.5 ± 1 (range 1–5, p < 0.001). Technical success rate was 83% (33/40) in intention-to-treat analysis and 100% in analysis of treated tumors. There were no major procedure-related complications.ConclusionsFusion imaging broadens the scope of US-guided MWA to metastasis lacking adequate conspicuity on conventional US. Fusion imaging is an effective tool to increase the conspicuity of liver metastases that were initially deemed non visualizable on conventional US imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ablation Volume Measurement After Percutaneous Cryoablation Using a Two-cryo-probe Technique for Small Hepatocellular Carcinomas

Purpose: To calculate the ablation volume of percutaneous cryoablation (PCA) with a two-cryo-probe technique for small hepatocellular carcinomas (HCCs) and to assess risk factors for local tumor recurrence (LTR). Materials and Methods: Between January 2013 and June 2017, 96 patients (mean age, 60.7 years; range, 37–83 years) with 106 small HCCs were retrospectively analyzed. The ablation volume, technical success, LTR rates, and complications were evaluated. Ablation volume was measured after the first freezing and immediately after completing PCA twice via computed tomography imaging. Prognostic factors associated with LTR were analyzed. Results: Technical success was achieved in all patients. The mean final ablation volume was 19.1 ± 4.8 cm{sup 3}, which was significantly higher than the first freezing ablation volume (14.7 ± 4.3 cm{sup 3}, p < 0.001). During the median follow-up period of 16.7 months (range, 5–52 months), LTR-free survival rates based on Kaplan–Meier analyses at 6 months, 1 year, and 2 years were 87.7%, 84.0%, and 80.2%, respectively. Only one major complication of post-procedural arterial bleeding occurred. A final ablation volume/tumor volume < 10 was a significant risk factor for LTR (p = 0.044). Conclusions: A ratio of final ablation volume to tumor volume < 10 was a significant prognostic factor for LTR. Therefore, the measurement and prediction of the final ablation volume are important to reduce LTR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗