Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “communication protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuous variable port-based teleportation

Abstract Port-based teleportation (PBT) is a generalisation of the standard teleportation protocol which does not require unitary operations by the receiver. This comes at the price of requiring N > 1 entangled pairs, while N = 1 for the standard teleportation protocol. The lack of correction unitaries allows PBT to be used as a fundamental theoretical tool to simulate arbitrary channels with a general resource, with applications to study fundamental limits of quantum communication, cryptography and sensing, and to define general programmable quantum computers. Here we introduce a general formulation of port-based teleportation in continuous variable systems and study in detail the N = 2 case. In particular, we interpret the resulting channel as an energy truncation and analyse the kinds of channels that can be naturally simulated after this restriction.

97 MATHEMATICS AND COMPUTING↗

Quantum Criticality Under Imperfect Teleportation

Entanglement, measurement, and classical communication together enable teleportation of quantum states between distant parties, in principle, with perfect fidelity. To what extent do correlations and entanglement of a many-body wave function transfer under teleportation protocols? We address this question for the case of an imperfectly teleported quantum critical wave function, focusing on the ground state of a critical Ising chain. We demonstrate that imperfections, e.g., in the entangling gate adopted for a given protocol, effectively manifest as weak measurements acting on the otherwise pristinely teleported critical state. Armed with this perspective, we leverage and further develop the theory of measurement-altered quantum criticality to quantify the resilience of critical-state teleportation. We identify classes of teleportation protocols for which imperfection (i) preserves both the universal long-range entanglement and correlations of the original quantum critical state, (ii) weakly modifies these quantities away from their universal values, and (iii) obliterates long-range entanglement altogether while preserving power-law correlations, albeit with a new set of exponents. We also show that mixed states describing the average over a series of sequential imperfect teleportation events retain pristine power-law correlations due to a “built-in” decoding algorithm, though their entanglement structure measured by the negativity depends on errors similarly to individual protocol runs. These results may allow one to design teleportation protocols that optimize against errors—highlighting a potential practical application of measurement-altered criticality. Published by the American Physical Society 2024

Physics↗

Building MCP-native hierarchical AI scientist ecosystems: a perspective on scaling multi-agent scientific discovery

Large language models (LLMs) are evolving from chatbots with limited tool-using capabilities to agentic AI systems that can perform deep research, assist in proposing hypotheses, help design experiments, automate data analysis, and draft scientific reports. However, there are currently two bottlenecks limiting LLMs' real-world impact on the broader scientific research community beyond academic demonstrations: lack of interoperability (repetitive manual tool-integration is required across scenarios) and the need for scalable coordination (unstructured communication and memory become brittle as the number of agents grows). In this Perspective, we argue that the next phase of agentic scientific discovery requires the development of an ecosystem of protocol-native agents and tools organized through hierarchies inspired by human society, beyond the current paradigm of a single monolithic “AI scientist”. We use Model Context Protocol (MCP) as a concrete example of an emerging interoperability layer for scientific tool and context exchange, and we propose three complementary pathways to increase the scaling capabilities of an MCP-native scientific ecosystem by addressing the composability issues: (1) MCP servers for high-value scientific tools maintained by domain experts, (2) automated transformation of existing code repositories into MCP services, and (3) autonomous invention and evolution of new agents and workflows. Finally, we provide a practical roadmap for scaling AI-driven scientific discovery by expanding tool supply and coordination in MCP-native scientific ecosystems.

97 MATHEMATICS AND COMPUTING↗

Quantum Key Distribution for Critical Infrastructures: Towards Cyber-Physical Security for Hydropower and Dams

Hydropower facilities are often remotely monitored or controlled from a centralized remote control room. Additionally, major component manufacturers monitor the performance of installed components, increasingly via public communication infrastructures. While these communications enable efficiencies and increased reliability, they also expand the cyber-attack surface. Communications may use the internet to remote control a facility’s control systems, or it may involve sending control commands over a network from a control room to a machine. The content could be encrypted and decrypted using a public key to protect the communicated information. These cryptographic encoding and decoding schemes become vulnerable as more advances are made in computer technologies, such as quantum computing. In contrast, quantum key distribution (QKD) and other quantum cryptographic protocols are not based upon a computational problem, and offer an alternative to symmetric cryptography in some scenarios. Although the underlying mechanism of quantum cryptogrpahic protocols such as QKD ensure that any attempt by an adversary to observe the quantum part of the protocol will result in a detectable signature as an increased error rate, potentially even preventing key generation, it serves as a warning for further investigation. In QKD, when the error rate is low enough and enough photons have been detected, a shared private key can be generated known only to the sender and receiver. We describe how this novel technology and its several modalities could benefit the critical infrastructures of dams or hydropower facilities. The presented discussions may be viewed as a precursor to a quantum cybersecurity roadmap for the identification of relevant threats and mitigation.

97 MATHEMATICS AND COMPUTING↗

Centrifugal contactor including central dynamic examination device

Centrifugal contactors that can be used for mixing or separating materials are described. The contactors include a sensing system including a communications fiber within the shaft of the contactors and access ports providing access from the communications fiber to the mixing/separating zone of the contactor. The sensing system can be utilized during operation of the contactor and can provide for detailed and accurate on-line characterization of a protocol, as well as process control and system modification as necessary during operation.

Restivo, Michael L.↗

Methods of separating materials by use of a centrifugal contactor

Centrifugal contactors that can be used for mixing or separating materials are described. The contactors include a sensing system including a communications fiber within the shaft of the contactors and access ports providing access from the communications fiber to the mixing/separating zone of the contactor. The sensing system can be utilized during operation of the contactor and can provide for detailed and accurate on-line characterization of a protocol, as well as process control and system modification as necessary during operation.

Restivo, Michael L.↗

Characterization of Agfa Structurix series D4 and D3sc x-ray films in the 0.7–4.6 keV energy range

X-ray films remain a key asset for high-resolution x-ray spectral imaging in high-energy-density experiments conducted at the National Ignition Facility (NIF). The soft x-ray Opacity Spectrometer (OpSpec) fielded at the NIF has an elliptically shaped crystal design that measures x rays in the 900–2100 eV range and currently uses an image plate as the detecting medium. However, Agfa D4 and D3sc x-ray films’ higher spatial resolution provides increased spectral resolution to the data over the IP-TR image plates, driving the desire for regular use of x-ray film as a detecting medium. The calibration of Agfa D4 x-ray film for use in the OpSpec is communicated here. These calibration efforts are vital to the accuracy of the NIF opacity measurements and are conducted in a previously un-studied x-ray energy range under a new film development protocol required by NIF. The absolute response of Agfa D4 x-ray film from 705 to 4620 eV has been measured using the Nevada National Security Site Manson x-ray source. A broader range of energies was selected to compare results with previously published data. The measurements were taken using selected anodes, filters, and applied voltages to produce well-defined energy lines.

Dutra, E. C. (ORCID:0000000167649195)↗

Dalton Project: A Python platform for molecular- and electronic-structure simulations of complex systems

The Dalton Project provides a uniform platform access to the underlying full-fledged quantum chemistry codes Dalton and LSDalton as well as the PyFraME package for automatized fragmentation and parameterization of complex molecular environments. The platform is written in Python and defines a means for library communication and interaction. Intermediate data such as integrals are exposed to the platform and made accessible to the user in the form of NumPy arrays, and the resulting data are extracted, analyzed, and visualized. Complex computational protocols that may, for instance, arise due to a need for environment fragmentation and configuration-space sampling of biochemical systems are readily assisted by the platform. The platform is designed to host additional software libraries and will serve as a hub for future modular software development efforts in the distributed Dalton community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gridtrust: Electricity Grid Root-of-Trust Decentralized Supply Chain Cyber-Security (Final Scientific/Technical Report)

GridTrust represents a departure from reliance on a single organization or a single person to multiple organizations and therefore multiple people across organizational structures. The motivating idea behind involving multiple organizations is the increase in security due to human factors. More specifically, the requirement that distinct people in different organizations sign off on a change or an update makes a cyberattack much less likely due to the inherent requirement that both organizations be penetrated and fooled. GridTrust focuses on the software update process as the primary exemplar for the research and development work. A novel hardware-based technology referred to as a Physical Unclonable Function (PUF) provides a microchip Root-of-Trust (RoT), i.e., a starting point for verifying that the hardware being communicated with is the hardware the control center believes the hardware to be. As a result, staff at power grid control centers can ensure the accurate and reliable identification of hardware devices from the outset. The GridTrust protocol introduces two key innovations, as detailed in this report. Firstly, the utilization of a PUF as a root-of-trust in the initial phase of a software or firmware update. Secondly, the application of multiple cryptographic signatures from two or more organizations to the update binary. These signatures are verified before implementing the update on a power grid device in the field. In terms of GridTrust hardware design, this report outlines two main components. The first is the GridTrust Native Device, integrating PUF technology intrinsically into the hardware device itself. The second is the GridTrust Interfacing Device, which incorporates PUF technology and multiple cryptographic signatures. These signatures are cross-checked within a separate hardware positioned between the power grid control center and the legacy power grid device, functioning as an intermediary. While the GridTrust Interfacing Device offers the advantage of being applicable to existing power grid equipment, it may have reduced security if the intermediary component is targeted. On the other hand, the GridTrust Native Device boasts increased security due to protocol integration within a unified form factor. The effectiveness of GridTrust technology has been extensively demonstrated, with multiple external red-team attackers unable to breach GridTrust's security measures. This was observed both in controlled laboratory settings during Phase 1 of the project and in real-world conditions within a City of Marietta substation during Phase 2 of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and evaluation of a cyber‐physical testbed for improving attack resilience of power systems

Abstract A power system is a complex cyber‐physical system whose security is critical to its function. A major challenge is to model, analyse and visualise the communication backbone of the power systems concerning cyber threats. To achieve this, the design and evaluation of a cyber‐physical power system (CPPS) testbed called Resilient Energy Systems Lab (RESLab) are presented to capture realistic cyber, physical, and protection system features. RESLab is architected to be a fundamental platform for studying and improving the resilience of complex CPPS to cyber threats. The cyber network is emulated using Common Open Research Emulator (CORE), which acts as a gateway for the physical and protection devices to communicate. The physical grid is simulated in the dynamic time frame using Power World Dynamic Studio (PWDS). The protection components are modelled with both PWDS and physical devices including the SEL Real‐Time Automation Controller (RTAC). Distributed Network Protocol 3 (DNP3) is used to monitor and control the grid. Then, the design is exemplified and the tools are validated. This work presents four case studies on cyberattack and defence using RESLab, where we demonstrate false data and command injection using Man‐in‐the‐Middle and Denial of Service attacks and validate them on a large‐scale synthetic electric grid.

Sahu, Abhijeet↗

Lessons Learned on the Interface Between Quantum and Conventional Networking

The future Quantum Internet is expected to be based on a hybrid architecture with core quantum transport capabilities complemented by conventional networking. Practical and foundational considerations indicate the need for conventional control and data planes that (i) utilize extensive existing telecommunications fiber infrastructure, and (ii) provide parallel conventional data channels needed for quantum networking protocols. We propose a quantum-conventional network (QCN) harness to implement a new architecture to meet these requirements. The QCN control plane carries the control and management traffic, whereas its data plane handles the conventional and quantum data communications. We established a local area QCN connecting three quantum laboratories over dedicated fiber and conventional network connections. We describe considerations and tradeoffs for layering QCN functionalities, informed by our recent quantum entanglement distribution experiments conducted over this network.

Alshowkan, Muneer↗

Achieving Cyber-Resilience for Power Systems using a Learning, Model-Assisted Blockchain Framework

The secure integration and management of distributed energy resources (DER) and power aggregators in the electric grid requires secure communications and a physics-aware Command and Control (C2) strategy. A Blockchain (BC)-based overlay network was developed to provide a security layer for the existing power grid network that mitigates risks in current and legacy network and C2 protocols. By integrating a Model-Assisted Machine Learning (MAML) framework with a Secure Blockchain Overlay Network (SBON) a defense-in-depth strategy was achieved. In our approach, the MAML framework leveraged a smart contract framework to gather network data and learn the dynamics of DER to develop detection strategies for attacks targeting sensors and actuators used by DER. The MAML framework learned dynamical systems models for individual DERs to detect sensor attacks. For DER we utilized a Digital Twin (DT) to accelerate the learning process for a model resistant to stealthy attacks. The project created DT for PV inverters and BESS. The DTs were coupled with a model-assisted, data-driven learning of DER behavior. Specifically, we evaluated architectures for model-based learning with model-free fine-tuning. Additionally, differential privacy techniques were used to obfuscate data, while still allowing the computation of attack detection results based on obfuscated data. The SBON developed leverages a private permissioned blockchain network orchestrated with the Hyperledger Fabric framework. To connect the cyber world, which orchestrates the blockchain fabric, and the physical world where the power network resides, we developed a system implementation to enable the secure interaction of the physical world and the abstracted blockchain.

97 MATHEMATICS AND COMPUTING↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Trust Model Measurements for the Energy Grid of Things

Information security is essential for the reliable operation of an Energy Grid of Things (EGoT). In addition to basic information security protocols as defined by published standards, there is a need for a monitoring function that measures the trustworthiness of the various actors participating in an EGoT. We describe in this paper the implementation and evaluation of a Distributed Trust Model that was developed specifically for monitoring communication within an EGoT. We then show how the model parameters are set using statistical measures for hypothesis testing.

Energy Grid of Things, EGoT, Smart Grid Security, ↗

Distributed Finite-Time Termination for Consensus Algorithm in Switching Topologies

Here, in this article, we present a finite-time stopping criterion for consensus algorithms in networks with dynamic communication topology. Prior state of the art has established convergence to the consensus value; however, the asymptotic convergence of these algorithms poses a challenge in practical settings where the response from agents is required in finite time. To this end, we propose a maximum-minimum protocol that propagates the global maximum and minimum values of agent states (while running the consensus algorithm) in the network. This article focuses on establishing that the global maximum and minimum values are strictly monotonic even for a dynamic topology, and they can be used to distributively ascertain the closeness to convergence in finite time. We rigorously show that each node can have access to the global maximum and minimum by running the proposed maximum-minimum protocol to realize a finite-time stopping criterion for the otherwise asymptotic consensus algorithm. The practical utility of the algorithm is illustrated through experiments where each agent is instantiated by a NodeJS socket.io server.

24 POWER TRANSMISSION AND DISTRIBUTION↗