The Influence of Communication on the Complexity of Connected Lighting Systems

Experience in the Next Generation Lighting Systems (NGLS) ”Living Lab” at the Parsons School of Design, has clearly shown the impacts of communication on the configuration complexity of the connected lighting systems installed there. Since 2017, NGLS has invited manufacturers to submit connected lighting systems for assessment against a set of specifications. To date, 14 systems of wirelessly connected LED luminaires and controls have been installed in classrooms with existing lighting. In nine of the rooms, new LED linear pendants or recessed troffers replaced existing luminaires; in the other rooms, LED “kits” were retrofitted into the existing troffers. Eleven of the installations featured sensors integrated in the luminaires or retrofit kits; the others used ceiling mounted sensors. All systems provided wall control devices for manual operation. For half of the installations, the complete systems were furnished by single companies; for the other half, luminaires and controls were furnished by separate companies. A total of 18 different companies provided products, with four of these located outside the United States including, Korea, Poland, Germany, and the Netherlands. In addition, two different electrical contractors in New York City provided multiple installation teams totaling 10 individuals, none of whom were familiar with any of the systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol-Based Sealant for Air Ducts Technology

Aerosol-based sealant can be used to seal air duct leaks. This is done by pressurizing the ducts and injecting the spray sealant. This technology can be used to seal small (up to ½-inch diameter) and inaccessible duct leaks hidden in wall, ceiling, and floor cavities (Ternes and Hwang2001). The aerosol sealant itself is a nontoxic vinyl polymer (Kallett et al. 2000). The technology is a proprietary duct-sealing method developed jointly by the U.S. government and Aeroseal, the company that holds an exclusive license to use the technology (Ternes and Hwang 2001). Specifically, Lawrence Berkeley National Laboratory developed the aerosol-spray technology with funding from the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency, and others while Aeroseal developed the current version of the equipment and software to apply the technology in practice (Ternes and Hwang 2001).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Coal-Based Commercial Facade Panels and Architectural Components (Phase I Final Report)

Semplastics has developed, tested, and documented the viability for commercialization of a new class of composite architectural panel materials that use coal as the primary constituent. This project produced sample panels using these novel materials that comprise 55% coal by mass (71% carbon by mass) and are comparable in dimensions to commercially available materials, while displaying superior mechanical strength, significant weight savings, and better insulating ability at a competitive cost. Phase I moved this coal-based composite materials technology from a Technology Readiness Level (TRL) of 3 to TRL 5. Semplastics’ new coal-based composite materials display an array of high-performance characteristics, including light weight, mechanical durability, temperature stability, and water resistance. These new materials require less energy to produce than comparable commercial products and could be manufactured on existing conventional plastic resin processing equipment in commercial quantities. The coal particles are completely encapsulated in ceramic from a polymer-derived ceramic (PDC) precursor, then bonded together by another inorganic resin. The material can be molded and cured to produce fireproof components such as ceiling panels, facades, and extruded underlayment, blocking, and backer boards, as well as other architectural design components such as moldings. The project included the production of sample panels for proof of concept, testing of the panels to show their improved characteristics, and development of a scale-up strategy to demonstrate the viability of the coal-based panels as a commercial alternative to existing building materials.

36 MATERIALS SCIENCE↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Second Target Station Target Segment Removal Dose Rates

This report documents the analysis of the dose rate fields in two configurations of the target system of the Second Target Station (STS) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) in support of the remote handling target segment removal operation. The two configurations detailed in this report are both assuming 8 hours since beam was incident on the target. The first configuration assumes all shielding is in place just as it was during operation and allows for confirmation of hands-on maintenance capability of the target drive components. The second configuration assumes that a hatch in the target drive room ceiling has been opened to the high bay, the target segment removable core vessel shield block has been removed, and there is a direct line-of-sight to the target segment some 5 m below the target drive room elevation. Dose rate fields in both configurations are documented in this report along with details of the methods of computation. The dose rate fields included in this report are intended to support the engineering of remote handling special equipment and the planning of remote handing operations. The models and analysis detailed in this report are in support of the preliminary design of the STS and future analysis is needed to support the final design of the STS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Heat transfer through a box beam from an impinging hydrogen flame

An analysis was performed to determine whether a hydrogen jet flame impinging on a tunnel ceiling composed of multiple prestressed steel reinforced concrete box beams could result in permanent damage to the tunnel. The lower layer of the concrete box beam was modeled to determine whether heat reaches the steel reinforcing bars and whether spalling could occur. Heat transfer analysis shows that the temperature remains constant at the location of the steel reinforcing bars after 1.3 minutes of impingement and reaches a maximum of 130°C after 5 minutes. However, assuming a constant impingement for 5 minutes is an over estimation due the existing fire model which includes conservative assumptions. Explosive spalling may occur at a thin layer (~0.05 in. at 50 seconds, 0.1 in. at 5 minutes) at the bottom surface of the concrete box beam, but the steel reinforcing bars will not be exposed to the hydrogen flame.

42 ENGINEERING↗

SAM Code Enhancements for Modeling of Liquid Metal-Cooled Fast Reactor Concepts

The SAM code is under development and supported by DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. These advanced reactor concepts incorporate novel and improved approaches to achieve safety and economic feasibility. This report summarizes two major efforts in addressing the modeling gaps in SAM for liquid-metal-cooled fast reactor (LMFR) applications, i.e. thermal mixing and stratification phenomena in large pools and corrosion-oxidation of components in flowing lead. A new one-dimensional model for thermal mixing and stratification effects in large pools and enclosures is developed and implemented. Thermal mixing and stratification occur when fluid enters a pool at a temperature different than the bulk fluid itself, a scenario often encountered during transients in pool-type systems. These phenomena are critical for the safety of reactors, impacting phenomena like natural circulation, which is essential for passive cooling. The improved model in SAM addresses limitations of state-of-the-art approaches by combining one-dimensional (1D) channels, representing the coolant jet flow, with lumped-parameter zero-dimensional (0D) pools, representing the rest of coolant in the tank. Energy exchange between the 1D jet and the 0D pools is based on heat transfer correlations calibrated against 3D simulations. It is verified that this model can handle various flow configurations, including hot jets in colder pools, cold jets in hotter pools, and the presence of features like ceilings, free surfaces, and obstacles. Additionally, validation against experimental data demonstrates the ability of the model to capture mixing and stratification effects in a wide range of conditions. The flexibility and improved accuracy of the new model make it a valuable tool for reactor safety analysis, allowing for the simulation of different geometries encountered in advanced reactors. A system-level corrosion modeling capability is developed and implemented in SAM to support Lead Fast Reactor (LFR) development. Although the initial focus of this capability will be on LFR application, this can later be expanded to include other liquid metals such as Lead-Bismuth Eutectic (LBE) and PbLi. This report summarizes the common corrosion mitigation strategies and outlines the progress on implementing and validating a corrosion-oxidation model in SAM. Verification and validation of the corrosion-oxidation portion of the model was performed using analytical solution and measured data from samples tested in the non-isothermal pumped lead loop at IPPE Obninsk. The iron transport and corrosion/precipitation portion of the model was assessed using an analytical model and measured corrosion depths from a natural convection lead loop experiment performed at CEA. It is demonstrated that the model implemented in SAM performed well in these assessments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Energy Codes Gap Analysis Field Study in the Southwest (Final Technical Report)

The primary goal of the “An Energy Codes Gap Analysis Field Study in the Southwest” project was to improve housing through strengthened building energy code implementation in two states, Colorado and Nevada, leading to greater energy and utility bill savings for households. Colorado is a home rule state. Nevada adopts a statewide code, but cities and counties must also adopt the code, making the state function like a home rule state. To broaden the impact of the project, an additional goal was to share and amplify project experiences, findings, and lessons that can be applied in other states. To achieve these goals, the project’s key objectives were to examine how residential energy codes are implemented in partner states; to use these findings to strengthen codes implementation through enhanced education, training, and outreach; and to enhance energy code technical assistance capabilities in the two partner states. In both partner states, the project led to the creation of a quantitative baseline understanding of compliance with high-impact energy code requirements, such as foundation, wall, and ceiling R-value; window U-factor and SHGC; envelope air tightness; duct tightness; and high-efficiency lighting. It then applied this baseline information to directly inform training in geographic areas with high levels of building and construction activity. The project has placed Colorado and Nevada among 23 states across the country that have conducted a single-family residential field study based on the established U.S. Department of Energy (DOE) methodology since 2014. It has also helped each State Energy Office test models for partnership- and relationship-building among government agencies and key stakeholder groups, including the State Energy Office and relevant code administration and professional licensing agencies, building officials, designers, builders, trades and utilities. At the national level, the project helped educate and inform State and Territory Energy Offices on a replicable methodology to assess energy code construction practices, effective stakeholder engagement strategies, and tailored energy code education and training. These findings are particularly pertinent for home-rule states, such as Colorado and Nevada, which rely on local government awareness and action to advance and implement building energy codes. By raising awareness of code adoption and compliance, this project has helped to equip each partner state with data on code compliance, strategies, education, and partnership models to advance building energy codes. This in turn will have an important impact on new construction practices in Colorado and Nevada, leading to more energy efficient and affordable housing. Currently, more than 62 percent of Colorado’s population lives in one of the 55 jurisdictions that have adopted the 2021 IECC to date, while nearly 95 percent of the state's population lives in one of the 208 jurisdictions that have adopted a code at 2015 IECC levels or higher. In Nevada, the 2018 IECC was adopted by the Governor’s Office of Energy in July 2018. By July 2020, 47 percent of the adopted energy code in the state was 2018 IECC which covers 96.5 percent of Nevada’s population. The training materials funded by this project focus on the 2021 IECC and will continue to be relevant in the two states as additional jurisdictions update their building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Effective Electrochromic Glazing Repositioning For Insulating Glass & Secondary Windows

This project addressed both technical and economic objectives toward significantly increasing the availability of ElectroChromic (EC) dynamic architectural glass at reduced cost. In contrast to the prevailing industry location of the EC device layer on the exterior light of an Insulating Glass (IG) unit, Project Objectives assessed the feasibility of a) repositioning the device layer midway between two IG panes to configure triple glazing, and b) independently framed to enable positioning to the building interior independent of the original glass configured as a dynamic secondary window. Parallel research complementing both EC-IG and EC-WinSert configurations addressed integral Photo Voltaic, and ceiling mounted “broadcast” power to circumvent the significant onsite electrical con tracting normally associated with the installation of commercial EC glazing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aligned carbon nanotubes for 1,000x improvement in computing (CRADA Final Report)

As part of the Cyclotron Road program, the Aligned Carbon team worked to improve and bring to market their technology to manufacture carbon nanotubes (CNTs) for integrated circuits. There are multiple applications which can benefit from the use of CNT based transistors in integrated circuits, including high performance computing, RF data transmission, and biosensing. Each of these applications faces a problem of poor starting CNT material to come to market. Aligned Carbon offers material with the highest ceiling of performance based around a fully aligned, uniform, on-wafer growth of CNTs and our proprietary purification process to remove metallic CNTs leaving only the semi-conducting ones behind. Further, Aligned Carbon has been guided by scalable manufacturing processes that will fit seamlessly into the integrated circuit foundry model of chip fabrication.

36 MATERIALS SCIENCE↗

AI Model Benchmarking for Nonproliferation Applications: Steel Thread Benchmarking Task Force Technical Report (Rev. 2)

Steel Thread is a NA-22 venture that seeks to build trustworthy, reliable AI models that can be used in a wide variety of nonproliferation tasks. A key aspect of building these models is developing appropriate benchmarks and evaluation methods, which will enable the venture to identify and adapt models to provide the most value in the nonproliferation domain. Benchmarks must be relevant to key tasks in this domain, such as question answering, information retrieval, document summarization and classification, consensus analysis, and image and data analysis. This report 1) provides an overview of benchmark design, evaluation, and challenges; 2) reviews a variety of open benchmarks, with a focus on language models and tasks; and 3) identifies benchmarks that are most relevant to Steel Thread. This report is intended to serve as a basis for further efforts to classify and evaluate benchmarks and their correlation with success on nonproliferation-specific tasks. The Steel Thread venture has defined benchmarks to be a particular combination of a dataset (or datasets) and a metric (or metrics) conceptualized as representing one or more specific tasks or sets of abilities for a specific modality. It is adopted by a research community as a shared framework for comparing methods.1 It includes 1) Data: Labeled (a designated subset not used for training, which could be all the data), 2) Metric: A way to quantify performance, 3) Task/Ability: What the benchmark is testing, 4) Protocol: A structured and repeatable evaluation process, 5) Baseline/Reference Model: For comparison; could be statistical, rule-based, SME-derived, or another model, and 6) Maintenance Plan: to update with new information over time; important for long-term utility. For further clarity, the definition includes what a benchmark, in this context, is not. It is not a corpus of training data, specific to a model (it is intended to apply to a range of models), a universal evaluation of performance, a guarantee that the ‘top’ model on the leaderboard will be the best fit for every specific use case, an all-encompassing proof of a model’s universal quality, nor is it a one-size-fits-all measure of success. It does not cover every real-world constraint (like operational, ethical, or cost considerations), a systems integration test, or a unit test. This definition was inspired by and resulted from discussions within the Steel Thread Benchmarking Task Force. This group was formed to define what we would mean as a benchmark within Steel Thread but persisted as the need to develop a thorough understanding of the large and expanding existing benchmarking space. This technical report is a result of the group’s divide and conquer approach to exploring this space. The release of benchmarks might not be progressing as quickly as model development, but it is moving very fast, as many benchmarks quickly become saturated, when state-of-the-art models score so close to the benchmark’s ceiling that their results are virtually indistinguishable. At that point, the test no longer differentiates between new systems, so researchers usually stop reporting scores as the benchmark no longer informs about improvements from the next generation of models. In the OpenAI announcement of GPT-5, they reported results on six flagship public benchmarks (AIME 2025, SWE-bench Verified, Aider Polyglot, MMMU, HealthBench Hard, GPQA) but the full system-card covers roughly thirty-five separate evaluations, comprising hundreds of test task items in total. There have been some efforts to summarize benchmarks in specific fields, like for text-to-image generation, but these surveys have had a narrow methodology scope. Therefore, a comprehensive survey of all benchmarks or even all benchmarks that could be relevant to Steel Thread is outside of the scope of this report. We chose some specific benchmarks to investigate in detail.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Technologies to Mitigate the Presence of Gaseous Elemental Mercury in Waste Disposal Containers

A study was conducted to evaluate sorbent technologies that can mitigate the presence of elemental mercury (Hg⁰) in waste containers for mercury-contaminated debris (MCD). Decontamination and demolition (D&D) activities at the Y-12 National Security Complex (Y-12) and other U.S. Department of Energy (DOE) Oak Ridge Reservation (ORR) facilities generate MCD requiring offsite disposal. The debris is packaged in appropriate waste containers and may be temporarily stored onsite prior to transport for treatment and/or disposal. During transportation of loads that had no visible liquid Hg at the point of origin, temperature changes can cause Hg⁰ to evaporate, condense, and form droplets on container walls. Furthermore, vibration during transportation could cause beads of Hg to be released from the debris, container walls, and ceiling, resulting in pools of liquid Hg⁰ on the container floor. Waste acceptance criteria (WAC) limitations for commercial disposal facilities, the Nevada National Security Site (NNSS), and ORR mixed low-level waste landfills prohibit the presence of any free liquids in containers identified as a solid waste form. Potential solutions to mitigate the presence of residual liquids that could be formed through vapor condensation include the use of sorbents or similar materials to capture and stabilize volatile Hg⁰ vapors and thus ensure compliance with landfill WAC requirements. This report summarizes data from small-scale laboratory experiments conducted to evaluate sorbent materials for Hg⁰ vapor suppression and sorption of liquid Hg⁰ that could form under relevant transportation and disposal conditions. A series of experiments was conducted to evaluate commercial sorbent materials and their effectiveness for Hg⁰ sorption across a temperature range from 19.4°C to 60°C. The impact of residual moisture on sorption was investigated under relevant conditions, and leaching tests were performed to assess the stability of Hg⁰ captured sorbent materials. The results provide estimates for sorbent quantities needed for a given Hg⁰ mass loading based on experimental results exposing sorbents to gaseous and liquid Hg⁰ at various mass ratios. Overall, sorbents that were most effective for Hg⁰ vapor suppression were brominated activated carbons, mackinawite-based sorbents coated on vermiculite, and sulfur-modified granular activated carbon. Elevated temperatures and moisture conditions did not result in significant increases of Hg⁰ headspace concentrations, and the materials also demonstrated high sorption capacities for the sorption of liquid Hg⁰.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward Trustworthy Autonomous Science: A Two-Year Community Roadmap

One year ago, the AISLE roadmap argued that autonomous laboratories operated as isolated islands and proposed a grassroots network organized around five critical dimensions. The field has since moved faster than that roadmap anticipated: multi-agent systems have produced experimentally validated hypotheses, self-driving laboratories have grown more interoperable and orchestrated, reasoning-trained and domain foundation models have raised the capability ceiling, and the Genesis Mission has placed autonomous experimentation at the center of U.S. federal science strategy, with industry emerging as a primary actor. Progress has met a sobering counter-current, including a corrected flagship discovery result, benchmarks showing that agents which rival experts on closed-ended questions still complete only a fraction of open-ended research, and fabricated citations surfacing at leading venues. We read this as the defining tension of the field: producing a candidate discovery is no longer the hard part, but verifying it is, and this asymmetry now limits autonomous science more than raw model capability. Accordingly, we update the roadmap around seven dimensions, revisiting the original five and elevating two former cross-cutting concerns, trust, verification, and reproducibility, and safety, security, and governance, to first-class status. We assess the original milestones (M1 through M14) as achieved, partially achieved, reframed, or open, add four new milestones (M15 through M18) for the elevated dimensions, and scope the path forward to a two-year horizon, with the first year concentrating on interfaces, protocol adoption, and the scaffolding of verification, and the second targeting federation, zero-trust coordination, and governance. Throughout, we position the grassroots network as the interoperability fabric that lets national programs, international initiatives, and commercial platforms connect rather than re-silo.

99 GENERAL AND MISCELLANEOUS↗

Planetary Boundary-Layer Height (PBLHT) Value-Added Product: Remote-Sensing Retrievals

The planetary boundary layer (PBL) is fundamental to numerous atmospheric processes, including aerosol mixing and transport, cloud evolution, and precipitation formation. A critical parameter in these studies is the PBL height (PBLHT). This vertical depth is essential for characterizing PBL structures in numerical simulations and serves as a primary metric for estimating flux exchanges between the Earth’s surface and the atmosphere. Radiosonde (SONDE) observations provide high-vertical-resolution measurements of temperature and moisture profiles and are widely used to estimate PBLHT (Liu and Liang 2010, Seidel et al. 2010). The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s PBLHT value-added product (VAP) for radiosonde measurements, known as PBLHTSONDE, applies three commonly used methods—the Heffter (1980) method, the Liu and Liang (2010) method, and the bulk Richardson number approach (Seibert et al. 2000)—to derive PBLHT. The PBLHTSONDE VAP operates routinely at ARM observatories and mobile facilities, with data available from the ARM Data Center shortly after sounding observations are collected (Sivaraman et al. 2013). However, radiosonde observations are limited by their low temporal resolution. Most stations launch soundings only twice daily, which constrains the ability to investigate and characterize the temporal evolution of the PBL using radiosonde data alone. The use of continuous remote-sensing observations provides high temporal resolution of PBLHT estimates. These observations include aerosol lidars (Dang et al. 2019, Su et al. 2020), Doppler lidar (DL; Tucker et al. 2009, Krishnamurthy et al. 2021), and water vapor and/or temperature lidars and radiometers (Turner et al. 2014). These observations provide valuable data on the PBL’s thermodynamic properties (e.g., water vapor and/or temperature lidars and radiometers), dynamic properties (e.g., DL), and distribution of tracer substances (e.g., aerosol lidars), all of which can be used to estimate PBLHT. ARM developed PBLHT estimates from the micropulse lidar (MPL; PBLHTMPL), Doppler lidar (PBLHTDL), and combined Raman lidar (RL)/atmospheric emitted radiance interferometer (AERI) thermodynamic profiles (PBLHTTHERMO). Each estimate captures different physical characteristics of the boundary layer—aerosol tracers, vertical velocity turbulence, and thermodynamic structure—and exhibits distinct strengths and limitations depending on the PBL regime and time of day. In addition, the ARM ceilometer (CEIL) provides three potential PBLHT candidates derived from the vendor's built-in algorithm. Building on these individual retrievals, ARM developed the PBLHTBEML VAP, which combines the four remote-sensing-based estimates with ancillary meteorological variables using the machine learning approach of Zhang et al. (2025) to produce a best-estimate PBLHT at 10-minute resolution.

54 ENVIRONMENTAL SCIENCES↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence P - Raw Data

Sequence P: Wake Flow Visualization, Upwind (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 15 m/s. Yaw angles of 0° to –60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The aluminum blade tip designed to contain a smoke generator was installed, and counterweights were installed in the non-instrumented blade tip to compensate. The turbine was positioned at the appropriate yaw angle, and the smoke generator was ignited remotely. The campaign duration was 3 minutes for all tests except P1000000, which was 2 minutes. The file name convention was the standard format except for P10000A0, which indicated a 3° pitch angle. File P1000000 used a 12° pitch angle. After these two campaigns were collected, it was determined that all subsequent data should be collected with a 3° pitch angle. Pressure data were not acquired during this sequence, so all associated data values were flagged as not applicable by setting the measured values in the data file to 0.000 Pa. Corresponding pressure data are available from Sequence H for the 3° pitch angle test points. Flow visualization data obtained from wall- and ceiling-mounted video cameras were recorded to videotape. The camera locations and calibration procedures are described in Appendix J.

17 WIND ENERGY↗

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles - Winter Park, FL 32789 Field test data available for wood moisture contents, temperature, and relative humidity. Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida residential building markets. These roofs are built with a layer of spray polyurethane foam (SPF) on the underside of the roof deck. Such a roof configuration positions the heating, ventilating, and air-conditioning equipment and ductwork within the conditioned space and improves airtight-ness in practice (by shifting the air barrier from the ceiling to the roofline). However, SPF is more expensive than fibrous insulation. Some builders have also become wary of using SPF because of liability concerns about indoor air quality and off-gassing. Unfortunately, un-vented roofs that use only air-permeable fibrous insulation (cellulose or fiberglass) have been demonstrated to be at risk of moisture issues in climate zone 2A because condensation and moisture accumulation occur at the ridge. This report describes research about a test implementation of an un-vented tile roof assembly in a hot-humid climate (Orlando, Florida; climate zone 2A); the roof was insulated with air-permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous work, the U.S. Department of Energy's Building America research team Building Science Corporation theorized that installation of diffusion vents might allow for the wintertime release of moisture to safe levels. Diffusion vents are open slots at the roof's highest points (the ridge and hips) that are covered with a water-resistant but vapor-open (500+ perm) air barrier membrane. The test home is a two-story slab-on-grade structure (3,600 ft2 ); the roof was insulated with a prototype insulation system (called boxed netting), which allows full depth insulation (i.e., it is not limited by the depth of the truss top chord). As a control comparison, one part of the roof was constructed as a typical un-vented roof (with a self-adhered membrane at the ridge). Ideally, failure would occur in the control roof and the experimental (diffusion vent) roofs would show sufficient drying to avoid failure. No intentional space conditioning was provided in the un-vented attic so worst-case humidity buildup conditions could be observed.

air leakage↗