The Gravity of Giraffe Physiology

By virtue of its tallness and terrestrial environment, the giraffe is a uniquely sensitive African animal to investigate tissue adaptations to gravitational stress. One decade ago, we studied transcapillary fluid balance and local tissue adaptations to high cardiovascular and musculoskeletal loads in adult and fetal giraffes. Previous studies by Goetz, Pattersson, Van Citters, Warren and their colleagues revealed that arterial pressure near the giraffe heart is about twice that in humans, to provide more normal blood pressure and perfusion to the brain. Another important question is how giraffes avoid pooling of blood and tissue fluid (edema) in dependent tissue of the extremities. As monitored by radiotelemetry, the blood and tissue fluid pressures that govern transcapillary exchange vary greatly with exercise. These pressures, combined with a tight skin layer, move fluid upward against gravity. Other mechanisms that prevent edema include precapillary vasoconstriction and low permeability of capillaries to plasma proteins. Other anatomical adaptations in dependent tissues of giraffes represent developmental adjustments to high and variable gravitational forces. These include vascular wall hypertrophy, thickened capillary basement membrane and other connective tissue adaptations. Our results in giraffe suggest avenues of future gravitational research in other animals including humans.

Hargens, Alan R.↗

Predictive models for moving contact line flows

Modeling flows with moving contact lines poses the formidable challenge that the usual assumptions of Newtonian fluid and no-slip condition give rise to a well-known singularity. This singularity prevents one from satisfying the contact angle condition to compute the shape of the fluid-fluid interface, a crucial calculation without which design parameters such as the pressure drop needed to move an immiscible 2-fluid system through a solid matrix cannot be evaluated. Some progress has been made for low Capillary number spreading flows. Combining experimental measurements of fluid-fluid interfaces very near the moving contact line with an analytical expression for the interface shape, we can determine a parameter that forms a boundary condition for the macroscopic interface shape when Ca much les than l. This parameter, which plays the role of an "apparent" or macroscopic dynamic contact angle, is shown by the theory to depend on the system geometry through the macroscopic length scale. This theoretically established dependence on geometry allows this parameter to be "transferable" from the geometry of the measurement to any other geometry involving the same material system. Unfortunately this prediction of the theory cannot be tested on Earth.

Rame, Enrique↗

Relative permeabilities for two-phase flow through wellbore cement fractures

Multiple fluids are likely to exist in fractures and flow paths associated with leaky wellbores, including liquids (e.g., crude oil) and gases (e.g., gas exsolved from liquid). These fluids occupy and move through different portions of the pore spaces within the fractures depending on many factors, including fluid properties, fracture size, and the amount of the different fluids. Upward leakage of any phase, through the fracture, can contaminate water-bearing formations, create hazardous surface conditions, and compromise the functionality of the wellbore. Early signs of wellbore leaks may be expressed by anomalous pressure behavior at surface monitoring points on cavern storage wells. These pressure anomalies are difficult to interpret, necessitating knowledge of the factors that affect the multiphase flow in fractures and porous media. These parameters are critical to modeling multiphase flow in fractures. This insight can guide further diagnosis and maximize leak remediation. Here, our study focuses on the relationship of the liquid–gas relative permeabilities for representative variable-aperture wellbore cement fracture. To obtain the relative permeability of each phase, two-phase flow tests were conducted where both fluids were flowing simultaneously through a fractured wellbore cement specimen under a range of factors, namely (1) aperture size, (2) capillary numbers, and (3) viscosity ratio. The flow experiments were conducted under a range of confining stresses and flow velocities, using nitrogen gas and silicone oils (of different viscosities) in a specially designed pressure vessel. The sum of gas and oil relative permeabilities were found to be less than one under all conditions, which indicates that the presence of one phase affects the permeability of the other phase, and vice versa. Since the gas phase flow conditions include a significant inertial flow component in addition to viscous flow, the inertial flow coefficients at different saturation states are presented. The factors affecting the relationship between the relative permeabilities are discussed in detail. A new mathematical model for estimating the relative permeability of wellbore cement fracture is presented and experimentally validated.

58 GEOSCIENCES↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

The coupling of interfacial instabilities and the stabilization of two-layer annular flows

In this paper the stability of annular pressure-driven parallel flows of two liquids sandwiching a free cylindrical interface is considered. For small to moderate Reynolds numbers, the interface is susceptible to capillary and interfacial wave instabilities, the latter instability caused by a jump in viscosity at the interface. It is shown that favorable velocity profiles in both liquids may stabilize capillary breakup of the interface and suppress the axisymmetric interfacial wave instability. A long-wave analysis leads to the physical mechanism responsible for stabilization of capillary breakup. This physical mechanism is a generalization of that by which capillary breakup is stabilized by interfacial shear in an annular film of a single liquid. Stabilization of intermediate wavelengths is studied with a mechanical energy analysis, which leads to a description of the energetic processes at work.

Dijkstra, Henk A.↗

A hydroponic system for microgravity plant experiments

The construction of a permanently manned space station will provide the opportunity to grow plants for weeks or months in orbit for experiments or food production. With this opportunity comes the need for a method to provide plants with a continuous supply of water and nutrients in microgravity. The Capillary Effect Root Environment System (CERES) uses capillary forces to maintain control of circulating plant nutrient solution in the weightless environment of an orbiting spacecraft. The nutrient solution is maintained at a pressure slightly less than the ambient air pressure while it flows on one side of a porous membrane. The root, on the other side of the membrane, is surrounded by a thin film of nutrient solution where it contacts the moist surface of the membrane. The root is provided with water, nutrients and air simultaneously. Air bubbles in the nutrient solution are removed using a hydrophobic/hydrophilic membrane system. A model scaled to the size necessary for flight hardware to test CERES in the space shuttle was constructed.

short duration↗

Capillary-Driven Heat Transfer Experiment: Keeping It Cool in Space

Capillary-pumped loops (CPL's) are devices that are used to transport heat from one location to another--specifically to transfer heat away from something. In low-gravity applications, such as satellites (and possibly the International Space Station), CPL's are used to transfer heat from electrical devices to space radiators. This is accomplished by evaporating one liquid surface on the hot side of the CPL and condensing the vapor produced onto another liquid surface on the cold side. Capillary action, the phenomenon that causes paper towels to absorb spilled liquids, is used to "pump" the liquid back to the evaporating liquid surface (hot side) to complete the "loop." CPL's require no power to operate and can transfer heat over distances as large as 30 ft or more. Their reliance upon evaporation and condensation to transfer heat makes them much more economical in terms of weight than conventional heat transfer systems. Unfortunately, they have proven to be unreliable in space operations, and the explanation for this unreliability has been elusive. The Capillary-Driven Heat Transfer (CHT) experiment is investigating the fundamental fluid physics phenomena thought to be responsible for the failure of CPL's in low-gravity operations. If the failure mechanism can be identified, then appropriate design modifications can be developed to make capillary phase-change heat-transport devices a more viable option in space applications. CHT was conducted onboard the Space Shuttle Columbia during the first Microgravity Science Laboratory (MSL-1) mission, STS-94, which flew from July 1 to 17, 1997. The CHT glovebox investigation, which was conceived by Dr. Kevin Hallinan and Jeffrey Allen of the University of Dayton, focused on studying the dynamics associated with the heating and cooling at the evaporating meniscus within a capillary phase-change device in a low-gravity environment. The CHT experimental hardware was designed by a small team of engineers from Aerospace Design & Fabrication (ADF), the NASA Lewis Research Center, and the University of Dayton. The hardware consisted of two experiment modules that each contained an instrumented test loop (idealized capillary-pumped loop), a base unit for power conversion and backlighting, a display unit with 15 LED's (light-emitting diodes) to display temperatures, pressure, heater power, and time, a control unit to select heaters and heater settings, a cooling fan, and associated cables.

Lekan, Jack F.↗

Chemical composition measurements of the atmosphere of Jupiter with the Galileo Probe mass spectrometer

The Galileo Probe entered the atmosphere of Jupiter on December 7, 1995. Measurements of the chemical and isotopic composition of the Jovian atmosphere were obtained by the mass spectrometer during the descent over the 0.5 to 21 bar pressure region over a time period of approximately 1 hour. The sampling was either of atmospheric gases directly introduced into the ion source of the mass spectrometer through capillary leaks or of gas, which had been chemically processed to enhance the sensitivity of the measurement to trace species or noble gases. The analysis of this data set continues to be refined based on supporting laboratory studies on an engineering unit. The mixing ratios of the major constituents of the atmosphere hydrogen and helium have been determined as well as mixing ratios or upper limits for several less abundant species including: methane, water, ammonia, ethane, ethylene, propane, hydrogen sulfide, neon, argon, krypton, and xenon. Analysis also suggests the presence of trace levels of other 3 and 4 carbon hydrocarbons, or carbon and nitrogen containing species, phosphine, hydrogen chloride, and of benzene. The data set also allows upper limits to be set for many species of interest which were not detected. Isotope ratios were measured for 3He/4He, D/H, 13C/12C, 20Ne/22Ne, 38Ar/36Ar and for isotopes of both Kr and Xe.

unmanned↗

Caprock Remains Water Wet Under Geologic CO 2 Storage Conditions

Abstract Carbon storage technology is primarily targeted in saline formations, which is a porous rock matrix filled with brine, sealed with a low permeability caprock. There are significant variations of CO 2 wetting properties, typically reported in the literature as contact angle of CO 2 and brine interacting with a rock material, suggesting that CO 2 could become wetting under geostorage conditions and negatively impact containment effectiveness. Here, we performed the first controlled laboratory measurements of CO 2 ‐brine contact angles on shale rocks from low permeability sealing formations with distinctive mineralogic properties—calcite‐rich, quartz‐rich, and dolomite‐rich. We targeted temperatures at 40° and 100°C, pressures at 8.3, 34.5, and 62.1 MPa, and salinity at 35,000 and 260,000 ppm. Results show no significant change in contact angle with mineralogy, temperature, pressure, salinity, and CO 2 bubble size. We conclude that caprocks will remain water‐wet at geologic CO 2 storage conditions and will not lose their capillary sealing capacity.

Tapriyal, Deepak↗

A study of circumferentially-heated and block-heated heat pipes. I - Experimental analysis and generalized analytical prediction of capillary limits. II - Three-dimensional numerical modeling as a conjugate problem

The wall and centerline vapor temperatures and heat output are determined experimentally for a low-temperature copper-water heat pipe under uniform circumferential heating and block heating. The time required to reach a vapor temperature of 60 C from an initial ambient temperature of 21 C is determined for both modes of heating. The experimental capillary limit of the heat pipe is compared to the generalized capillary limits for block-heated pipes over a range of vapor temperatures. A three-dimensional numerical model is then developed for determining the temperature, pressure, and velocity distributions in the entire domain of a circumferentially heated and a block-heated pipe. The problem is formulated as a conjugate problem, without the assumption of a uniform vapor temperature. The predictions of the model are found to be in good agreement with the experimental data.

Schmalhofer, Joseph↗

Microgravity Liquid-Gas Two-Phase Flow: Review of Pressure Drop and Heat Transfer Correlations and Guidelines for Equipment Operability

In this report we have catalogued the flow regimes observed in microgravity, summarized correlations for the pressure drop and rate of heat transfer that are commonly used, and discuss the validation of a few correlations from available experimental results. Two-phase flow through some specific components such as bends, tees, filters and pumps are discussed from a physical perspective to guide the designer on how reduced gravity might affect their performance. Phase separation in zero gravity is addressed through the behavior and basic design concepts for devices based on passive centrifugal action, capillary forces, gas extraction through a membrane installed in a channel wall and the use of a syringe with a perforated piston to remove bubbles from small liquid volumes. We address the common instabilities that develop in flow loops owing exclusively to the two-phase nature of the flow, e.g., Ledinegg instability and concentration waves. Finally we briefly review flow metering and gauging; two-phase flow through porous media, where pressure drop and flow regime map correlations in zero-g are a current research topic; and basic operation principles of heat pipes and capillary pumped loops.

liquid-gas↗

A fluctuating hydrodynamics model for nanoscale surfactant-laden interfaces

A multispecies diffuse interface model is formulated in a fluctuating hydrodynamics framework for the purpose of simulating surfactant interfaces at the nanoscale. The model generalizes previous work to ternary mixtures, employing a Cahn-Hilliard free energy density combined with incompressible, isothermal fluctuating hydrodynamics where dissipative fluxes include both deterministic and stochastic terms. The intermolecular parameters in the free energy are chosen such that one species acts as a partially miscible surfactant. From Laplace pressure measurements, we show that in this model the surface tension decreases linearly with surfactant concentration, leading to Marangoni convection for interfaces with concentration gradients. In the capillary wave spectrum for interfaces with and without surfactant, we find that for the former, the spectrum deviates significantly from classical capillary wave theory, presumably due to Gibbs elasticity. In non-equilibrium simulations of the Rayleigh-Plateau instability, deterministic simulations showed that the surfactant delays pinching of a fluid cylinder into droplets. However, stochastic simulations indicate that thermal fluctuations disrupt the surfactant's stabilizing effect. Similarly, the spreading of a patch of surfactant, driven by Marangoni convection, was found to be partially suppressed by thermal fluctuations.

Capillary waves↗

Design, development and test of a capillary pump loop heat pipe

The development of a capillary pump loop (CPL) heat pipe, including computer modeling and breadboard testing, is presented. The computer model is a SINDA-type thermal analyzer, combined with a pressure analyzer, which predicts the transients of the CPL heat pipe during operation. The breadboard is an aluminum/ammonia transport system which contains multiple parallel evaporator and condenser zones within a single loop. Test results have demonstrated the practicality and reliability of such a design, including heat load sharing among evaporators, liquid inventory/temperature control feature, and priming under load. Transport capability for this system is 65 KW-M with individual evaporator pumps managing up to 1.7 KW at a heat flux of 15 W/sq cm. The prediction of the computer model for heat transport capabilities is in good agreement with experimental results.

Kroliczek, E. J.↗

Modeling Adsorption in Silica Pores via Minkowski Functionals and Molecular Electrostatic Moments

Capillary condensation phenomena are important in various technological and environmental processes. Using molecular simulations, we study the confined phase behavior of fluids relevant to carbon sequestration and shale gas production. As a first step toward translating information from the molecular to the pore scale, we express the thermodynamic potential and excess adsorption of methane, nitrogen, carbon dioxide, and water in terms of the pore’s geometric properties via Minkowski functionals. This mathematical reconstruction agrees very well with molecular simulations data. Our results show that the fluid molecular electrostatic moments are positively correlated with the number of adsorption layers in the pore. Moreover, stronger electrostatic moments lead to adsorption at lower pressures. These findings can be applied to improve pore-scale thermodynamic and transport models.

42 ENGINEERING↗

Economic method for measuring ultra-low flow rates of fluids

Capillary tube flowmeter measures ultra-low flows of very corrosive fluids /such as chlorine trifluoride and liquid fluorine/ and other liquids with reasonable accuracy. Flowmeter utilizes differential pressure transducer and operates on the principle that for laminar flow in the tube, pressure drop is proportional to flow rate.

Bogdanovic, J. A.↗

A hydroponic method for plant growth in microgravity

A hydroponic apparatus under development for long-term microgravity plant growth is described. The capillary effect root environment system (CERES) is designed to keep separate the nutrient and air flows, although both must be simultaneously available to the roots. Water at a pressure slightly under air pressure is allowed to seep into a plastic depression covered by a plastic screen and a porous membrane. A root in the air on the membrane outer surface draws the moisture through it. The laboratory model has a wire-based 1.241 mm mesh polyethylene screen and a filter membrane with 0.45 micron pores, small enough to prohibit root hair penetration. The design eliminates the need to seal-off the plant environment. Problems still needing attention include scaling up of the CERES size, controlling biofouling of the membrane, and extending the applications to plants without fibrous root systems.

Wright, B. D.↗

Jet-A fuel evaporation analysis in conical tube injectors

A simple one-dimensional drop-life-history analysis and a multidimensional spray calculation using KIVA-II code are applied to the vaporization of Jet-A fuel in multiple tube injectors. Within the assumptions of the analysis, the one-dimensional results are useful for design purposes. The pressure-atomizer breakup models do not accurately predict the dropsize measured experimentally or deduced from the one-dimensional analysis. Cold flow visualization and dropsize measurements show that capillary wave breakup mechanism plays an important role in the spray angle and droplet impingement on the tube wall.

Lai, M.-C.↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge mass spectrometry (SCGD-MS) apparatus comprises a SCGD source and a mass spectrometer. The SCGD source may comprise conductive rods, a power source, and a capillary. A method for ionizing an analyte comprises flowing an electrically conductive liquid onto a conductive rod, applying an electric potential to a second conductive rod such that a plasma discharge forms between the first conductive rod and the electrically conductive liquid to produce ions, and separating the ions in a mass spectrometer. The analyte may be a polypeptide that may be contacted with trypsin. The analyte may be a solid, liquid, gas, chemical complex, or ion in solution. The method may comprise sequencing the polypeptide.