Simulation study of the effect of fuel-conservative approaches on ATC procedures and terminal area capacity

Fuel-conservative procedures have been investigated using real-time air traffic control simulations linked to two piloted simulators. The fuel-conservative procedures studied were profile descents and two types of landing approaches. The investigation determined the effect of these procedures on the ATC system and terminal area capacity. It examined the mixing of aircraft executing fuel-conservative approaches with those executing conventional approaches. The results indicate a systems fuel savings for the landing approaches under all tested conditions except at, or near, maximum system capacity. Also, there is a fuel savings and reduced controller workload for the profile descent procedures.

Tobias, L.↗

Refurbishment of NASA's Johnson Space Center Liquid Nitrogen Bulk Storage Tanks in Preparation for Thermal Vacuum Optical Testing of the James Webb Space Telescope (JWST)

NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the "Great Observatories", scheduled for launch in 2019. It is directly responsible for the integration and test (I&T) program that culminated in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. Chamber A utilizes Liquid Nitrogen as a thermal barrier between the 300 Kelvin vessel wall and the 20 Kelvin helium environmental conditioning shrouds. The 155,000 gallon capacity of the six vessels support long duration testing which support low and deep space simulations for today's testing. This paper describe the challenges of refurbishing six liquid nitrogen bulk storage vessels that are 60 year old. The vessels were refurbished in place and focused primarily on the vacuum annulus. The challenges of vessel research, design engineering and project management will be discussed. The refurbishment of the vessels has extended the life of the vessels for another 35-50 years on the vacuum annulus integrity. The survivability of the bulk storage vessels was tested during the historic hurricane Harvey of 2017 during the 100 day JWST thermal-vacuum test.

Garcia, Sammy↗

Performance Assessment of ISS Water Processor Assembly Reactor

Due to modifications to the ISS waste water composition, the concentration of volatile organics has significantly increased in the feed to the Water Processor Assembly (WPA). In parallel, the oxygen supply pressure increased, resulting in a higher flow rate of oxygen to the WPA. Preliminary testing at Hamilton Sund strand indicated that the higher oxygen flow rate would increase the WPA capacity for volatile organics. Following an analysis of the expected waste water composition, personnel at NASA MSFC and Hamilton Sundstrand conducted a test of a flight-like reactor to assess its capacity for the higher organic loads. The results of this test indicate the WPA can accommodate the expected organic load in the ISS waste water with margin.

Carter, Layne↗

Tidal volume single-breath washin of SF6 and CH4 in transient microgravity

We performed tidal volume single-breath washins (SBW) by using tracers of different diffusivity and varied the time spent in microgravity (microG) before the start of the tests to look for time-dependent effects. SF(6) and CH(4) phase III slopes decreased by 35 and 26%, respectively, in microG compared with 1 G (P < 0.05), and the slope difference between gases disappeared. There was no effect of time in microG, suggesting that neither the hypergravity period preceding microG nor the time spent in microG affected gas mixing at volumes near functional residual capacity. In previous studies using SF(6) and He (Lauzon A-M, Prisk GK, Elliott AR, Verbanck S, Paiva M, and West JB. J Appl Physiol 82: 859-865, 1997), the vital capacity SBW showed an increase in slope difference between gases in transient microG, the opposite of the decrease in sustained microG. In contrast, tidal volume SBW showed a decrease in slope difference in both microG conditions. Because it is only the behavior of the more diffusive gas that differed between maneuvers and microG conditions, we speculate that, in the previous vital capacity SBW, the hypergravity period preceding the test in transient microG provoked conformational changes at low lung volumes near the acinar entrance.

Parabolic Flight↗

Effects of curative treatment emphasizing endurance training on the performance and blood pressure of hypertensive and normotensives

The problem of normal values of blood pressure after exercise taking into account the blood pressure at the end of the exercise test is discussed. Hypertensives showed a lower working capacity than normotensives. In normotensives, however, systolic blood pressure at the end of an exercise correlated well with the working capacity. After the endurance cure submaximal blood pressure was markedly lower in hypertensives with a striking dependence on the level of initial values. Systolic blood pressure at the end of an exercise test was not changed significantly. Most probably it is not possible to overcome this malregulation in hypertensives by endurance training alone.

Worms, F.↗

Design, fabrication and testing of a dual catalyst ammonia removal system for a urine VCD unit

A three-man capacity catalytic system for the recovery of water from urine was designed, constructed, and tested, it was designed to operate with feed streams containing high concentrations of urine vapor and only 5 to 7% of oxygen for the oxidation of ammonia and volatile organic vapor.It can operate either in a flow-through or a recycle mode and is capable of accepting the urine vapor produced by a vapor compression distillation evaporator. Testing consisted of short preliminary and optimization test, an endurance test of 74 hours continuous operation, and recycle tests using both air and oxygen. The system was designed for a urine processing rate of 0.86 liters/hr; however, it was tested at rates up to 1.2 liter/hr. Untreated urine evaporated by an electrically heated evaporator was used. The quality of the recovered water meets the U.S. Drinking Water Standards, with the exception of a low pH. Accumulation of solids in the urine sludge is reduced to approximately 65% of the anticipated value.

Budinikas, P.↗

Performance and Safety Characteristics of Sanyo NiCd Cells

NiCd batteries are widely used for high drain applications like power tools and also in other portable equipment like cameras, PCs, etc. NASA and Dreamtime Holdings, Inc. worked together to have the capability of a High Definition TV (HDTV) on the ISS and Space Shuttle. The Sanyo HD camcorder was used on the STS 105 fight in July, 2001 . The camcorder used two versions of a NiCd battery. One was a cOlnmercial off-the-shelf Sony BP90 battery pack that had Sanyo NiCd D cells. The other was a modified battery (FBP-90) made by Frezzi Energy, which also had the same Sanyo NiCd D cells. The battery has 10 NiCd D cells in series to form a 12 V pack with 5.0 Ah capacity. Our current study involved the perforn1ance and abuse tests on the Sanyo NiCd 5.0 Ah D cells. The best combination of charge/discharge current rate is 0.3C for charge and 1/2e for discharge within 200 cycles. No significant changes in capacity were observed in 200 cycles. The cell also showed capability of 5C (25.0A) high rate discharge. In overcharge and overdischarge tests, all tested cells passed the tests without venting. In imbalance tests, the battery pack could be charged and discharged only at relatively low current. At charge current of 1.0A or less, the imbalanced cells in the battery pack displayed relatively high temperatures during charge or discharge. The cells functioned normally during internal short and no mishap occurred during external short. Cells passed exposure tests at 80 C and no leakage till 150 C during heat-tovent tests.

Deng, Yi↗

Assessment of radar resolution requirements for soil moisture estimation from simulated satellite imagery

Radar simulations were performed at five-day intervals over a twenty-day period and used to estimate soil moisture from a generalized algorithm requiring only received power and the mean elevation of a test site near Lawrence, Kansas. The results demonstrate that the soil moisture of about 90% of the 20-m by 20-m pixel elements can be predicted with an accuracy of + or - 20% of field capacity within relatively flat agricultural portions of the test site. Radar resolutions of 93 m by 100 m with 23 looks or coarser gave the best results, largely because of the effects of signal fading. For the distribution of land cover categories, soils, and elevation in the test site, very coarse radar resolutions of 1 km by 1 km and 2.6 km by 3.1 km gave the best results for wet moisture conditions while a finer resolution of 93 m by 100 m was found to yield superior results for dry to moist soil conditions.

Ulaby, F. T.↗

Working and strategic memory deficits in schizophrenia

Working memory and its contribution to performance on strategic memory tests in schizophrenia were studied. Patients (n = 18) and control participants (n = 15), all men, received tests of immediate memory (forward digit span), working memory (listening, computation, and backward digit span), and long-term strategic (free recall, temporal order, and self-ordered pointing) and nonstrategic (recognition) memory. Schizophrenia patients performed worse on all tests. Education, verbal intelligence, and immediate memory capacity did not account for deficits in working memory in schizophrenia patients. Reduced working memory capacity accounted for group differences in strategic memory but not in recognition memory. Working memory impairment may be central to the profile of impaired cognitive performance in schizophrenia and is consistent with hypothesized frontal lobe dysfunction associated with this disease. Additional medial-temporal dysfunction may account for the recognition memory deficit.

Memory Disorders/etiology/physiopathology↗

Hazards Due to Overdischarge in Lithium-ion Cylindrical Cells in Multi-cell Configurations

Lithium-ion cells in the cylindrical Commercial-off-the-shelf 18650 design format were used to study the hazards associated with overdischarge. The cells in series or in parallel configurations were subjected to different conditions of overdischarge. The cells in parallel configurations were all overdischarged to 2.0 V for 75 cycles with one cell removed at 25 cycles to study the health of the cell. The cells in series were designed to be in an unbalanced configuration by discharging one cell in each series configuration before the start of test. The discharge consisted of removing a pre-determined capacity from the cell. This ranged from 50 to 150 mAh removal. The cells were discharged down to a predetermined end-of-discharge voltage cutoff which allowed the cell with lower capacity to go into an overdischarge mode. The cell modules that survived the 75 cycles were subjected to one overvoltage test to 4.4 V/cell.

Jeevarajan, Judith↗

The Effect of Supercharger Capacity on Engine and Airplane Performance

This report presents the results of an investigation to determine the effect of different supercharger capacities on the performance of an airplane and its engine . The tests were conducted on a DH4-M2 airplane powered with a Liberty 12 engine. In this investigation four supercharger capacities, obtained by driving a roots type supercharger at 1.615, 1.957, 2.4, and 3 time engine speed, were used to maintain sea-level pressure at the carburetor to altitudes of 7,000, 11,500, 17,000, and 22,000 feet, respectively. The performance of the airplane in climb and in level flight was determined for each of the four supercharger drive ratios and for the unsupercharged condition. The engine power was measured during these tests by means of a calibrated propeller. It was found that very little sacrifice in sea-level performance was experienced with the larger supercharger drive ratios as compared with performance obtained when using the smaller drive ratios. The results indicate that further increase in supercharger capacity over that obtained when using 3:1 drive ratio would give a slight increase in ceiling and in high-altitude performance but would considerably impair the performance for an appreciable distance below the critical altitude. As the supercharger capacity was increased, the height at which sea-level high speeds could be equaled or improved became a larger percentage of the maximum height of operation of the airplane.

Schey, O W↗

Hemodynamic and thermal responses to head and neck cooling in men and women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

NASA Center ARC↗

Design and Fabrication of the NASA Decoupler Pylon for the F-16 Aircraft, Addendum 2

The decoupler pylons which were originally designed and assembled with bushings in the pivot joints were retrofitted with roller bearings. This retrofit, the supporting analyses and the fixture tests of the modified pylons are reported in this document. The loads and stress analysis was directed toward the redesigned parts which were the pylon links and pins. The loads and stress analysis indicates that the pylons with the bearing installation have reduced capacity with respect to the bushing design. Fixture tests of the redesigned pylons were conducted in the GD/FW facility. Breakout friction tests and vibration tests were conducted. The tests show that the joint friction is approximately one-half the level with bearings as compared with the bushing installation. The vibration test data was used to tune the pylon mathematical simulation and this revised pylon simulation was used to recompute airplane modes of vibration. These computed modes of vibration were used in complete airplane symmetric and antisymmetric flutter and aeroservoelastic analyses.

Clayton, J. D.↗

Evaluation program for secondary spacecraft cells: Acceptance tests of Eagle-Picher 12.0 ampere-hour nickel-cadmium cells with auxiliary electrodes

An acceptance test program was conducted on 24 cells to insure that all cells put into the life cycle program were of high quality by the removal of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts after the cell short test. The cells were rated at 12.0 ampere-hours and equipped with auxiliary electrodes. Test results were: (1) The capacity of the 24 cells ranged from 14.6 to 16.8 ah. All the cells exceeded the rated capacity on all three capacity checks. (2) One cell failed to recover to 1.150 volts after the cell short test. (3) During the overcharge tests, all cells but one failed the test at the c/10 rate after the first minute. (4) A special resistance test was conducted on the auxiliary electrodes of these cells to establish the resistance value necessary which would provide maximum signal power across the auxiliary electrode. The resistance value established was 10 ohms. (5) No electrolyte leakage was observed.

Christy, D. E.↗

Safety Limitations Associated with Commercial 18650 Lithium-ion Cells

In the past decade, NASA-JSC battery group has carried out several tests on the safety of li-ion cells, modules and battery packs. The hazards associated with using commercial li-ion cells in high voltage and high capacity batteries have been determined to be different from those associated with the use of the same cells in low voltage, low capacity packs (less than 15 V and 60 Wh). Tests carried out included overcharge, overdischarge, external and internal short circuits with destructive physical analysis included in most cases. Chemical analysis, X-rays and in some cases CT scans were used for post-test analysis.

Jeevarajan, Judith A.↗

Summary of LDEF battery analyses

Tests and analyses of NiCd, LiSO2, and LiCf batteries flown on the Long Duration Exposure Facility (LDEF) includes results from NASA, Aerospace, and commercial labs. The LiSO2 cells illustrate six-year degradation of internal components acceptable for space applications, with up to 85 percent battery capacity remaining on discharge of some returned cells. LiCf batteries completed their mission, but lost any remaining capacity due to internal degradation. Returned NiCd batteries tested an GSFC showed slight case distortion due to pressure build up, but were functioning as designed.

Johnson, Chris↗

The Effect of Variable End of Charge Battery Management on Small-Cell Batteries

Batteries are critical components for spacecraft, supplying power to all electrical systems during solar eclipse. These components must be lightweight due to launch vehicle limitations and the desire to fly heavier, more capable payloads, and must show excellent capacity retention with age to support the ever growing durations of space missions. ABSL's heritage Lithium Ion cell, the ABSL 18650HC, is an excellent low mass solution to this problem that has been proven capable of supporting long mission durations. The NASA Glenn Research Center recently proposed and initiated a test to study the effects of reduced end of charge voltage on aging of the ABSL 18650HC and other Lithium Ion cells. This paper presents the testing details, a method to analyze and compare capacity fade between the different cases, and a preliminary analysis of the to-date performance of ABSL s cells. This initial analysis indicates that employing reduced end of charge techniques could double the life capabilities of the ABSL 18650HC cell. Accordingly, continued investigation is recommended, particularly at higher depths of discharge to better assess the method s potential mass savings for short duration missions.

Neubauer, Jeremy S.↗

Survey and Experimental Testing of Nongravimetric Mass Measurement Devices

Documentation presented describes the design, testing, and evaluation of an accelerated gravimetric balance, a low mass air bearing oscillator of the spring-mass type, and a centrifugal device for liquid mass measurement. A direct mass readout method was developed to replace the oscillation period readout method which required manual calculations to determine mass. A protoype 25 gram capacity micro mass measurement device was developed and tested.

Oakey, W. E.↗