Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Networked Microgrids Optimization

This project is mainly about the operation optimization of three networked microgrids (MG), including centralized optimization and distributed optimization. The alternating direction method of multipliers (ADMM) algorithm is used for distributed optimization. In the distribution network considered here, there is a Distribution Management system (DMS) as the system coordinator and several networked microgrids. In grid-connected mode, power could be imported or exported at the distribution substation bus according to the utility rate, and the exchanged power at point of common coupling (PCC) of any microgrid has a limitation. In islanded mode, the power imports/exports at the distribution substation are zero. In both grid-connected and islanded mode, the distribution substation is taken as a slack bus with fixed voltage magnitude.

Chen, Yang [Oak Ridge National Laboratory (ORNL), ↗

Electric Grid Simulator For Human Factor Research

The developed code simulates real-time monitor and control for west area of IEEE 118-bus system. The 24-hour load profile for each bus is derived by scaling the system’s rated load in the PSSE sav file according to the California Independent System Operator’s Day-ahead load forecast for May 1, 2024. This simulator performs several critical functions: (1) Calculating time-series power flow every 4 seconds; (2) Updating and dispatching AGC signals every minute; (3) Conducting N-1 contingency analysis every 5 minutes. Additionally, the simulator can trip lines and subsequently update and dispatch AGC signals, running power flow analysis after each tripping event.

Huang, Jianqiao [Idaho National Laboratory (INL), ↗

LDES-Sizing-and-siting-model (Power grid test cases for long-duration energy storage (LDES) siting) [SWR-25-75]

This repository contains code and data for performing a siting analysis of long-duration energy storage (LDES) in the 5-bus and RTS systems using the Sienna suite developed by the National Renewable Energy Laboratory for production cost modeling (PCM). This analysis involves moving the LDES component to different buses in the system, running a simulation, and considering the production cost of the simulation. Different system configurations are also analyzed with these scripts (such as moving load or renewable dispatch generators to different buses) to observe the impacts the system configuration has on optimal siting. This repository contains three sub directories discussed below. Both the 5-bus and RTS systems have two different initial configurations for the renewable energy components in them, one that is predominantly PV-driven and one that is predominantly wind-driven. Sienna suite can be found here: https://github.com/NREL-Sienna

Cole, David [University of Wisconsin]↗

Silicon photonic chip for 16-channel wavelength division (de-)multiplexing in the O-band

We experimentally demonstrate a silicon photonic chip-scale 16-channel wavelength division multiplexer (WDM) operating in the O-band. The silicon photonic chip consists of a common-input bus waveguide integrated with a sequence of 16 spectral add-drop filters implemented by 4-port contra-directional Bragg couplers and resonant cladding modulated perturbations. The combination of these features reduces the spectral bandwidth of the filters and improves the crosstalk. An apodization of the cladding modulated perturbations between the bus and the add/drop waveguides is used to optimize the strength of the coupling coefficient in the propagation direction to reduce the intra-channel crosstalk on adjacent channels. The fabricated chip was validated experimentally with a measured intra-channel crosstalk of ∼−18.9 dB for a channel spacing of 2.6 nm. The multiplexer/demultiplexer chip was also experimentally tested with a 10 Gbps data waveform. The resulting eye-pattern indicates that this approach is suitable for datacenter WDM-based interconnects in the O-band with large aggregate bandwidths.

Davis, Jordan A. (ORCID:0000000343483295)↗

High-speed silicon microresonator modulators with high optical modulation amplitude (OMA) at input powers >10 mW

A high-speed silicon photonic microdisc modulator is used with more than 10 mW optical power in the bus waveguide, extending the optical power handling regime used with compact silicon resonant modulators at 1550 nm. We present an experimental study of the wavelength tuning range and biasing path required to shift the resonant frequency to the optimal point versus on chip power. We measure the optical modulation amplitude (OMA) along different biasing trajectories of the microdisc under active modulation and demonstrate an OMA of 4.1 mW with 13.5 mW optical power in the bus waveguide at 20 Gbit/s non-return to zero (NRZ) data modulation.

Wang, Xiaoxi↗

Onboard/Origin-Destination Survey - Phoenix - 2007

In 2007, the Valley Metro Regional Public Transportation Authority, with consultant support, conducted an origin and destination survey of Valley Metro riders. The self-administered surveys were conducted among riders of fixed-route bus service: Local, Circulator, Limited, Rural, Express, and RAPID bus. Data collection was performed from October 8 through December 18, 2007. The objectives of the survey were to examine the demographics and travel behavior characteristics of Valley Metro riders. The survey data used for this analysis were appropriately weighted and expanded to represent the unlinked trips made by Valley Metro riders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Composition Analysis in Support of the NERC Load Modeling Task Force. 2019-2020 Field Test of the Composite Load Model

In 2015, NERC’s reliability standards were revised to require the use of dynamic load models in transmission planning studies. To comply with the standards, planners must use load models that explicitly represent the dynamic behavior of the different constituents of load at each load bus within their transmission planning models. The most important of these constituents are motor-driven and power electronics-based loads. Collectively, these representations are known as composite load models. In anticipation of the compliance date for the new standards, NERC’s Load Modeling Task Force (LMTF), in 2019, initiated a field test of composite load models involving the regional reliability planning entities. In support of the field test, DOE and BPA researchers developed region-specific composite load models that could be assigned to each non-industrial load bus in the planning models for each of the North American interconnections. Separate models were developed for each hour of a summer peak day, a winter peak day, and a spring light-load day. This report is the technical documentation for the load composition analysis that was conducted to develop these non-industrial composite load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulink Modeling and Dynamic Study of Fixed-Speed, Variable-Speed, and Ternary Pumped Storage Hydropower

Pumped Storage Hydropower (PSH) is one of the most popular energy storage technologies in the world. It uses an upper reservoir to store water which can be later used during high-demand. In the United States, most of the energy storage capability actually corresponds to PSH. Moreover, PSH also brings multiple benefits to grid operation. This report presents the Simulink models of three common PSH technologies: Fixed-Speed (FS), Variable-Speed (VS), and Ternary (T)-PSH. These models are available to the general public on this GitHub repository, which contains the MATLAB model initialization files, the Simulink model files, and supplementary MATLAB code used to obtain the figures in this work. For each PSH model, an introductory description of the model components and other relevant functionalities are provided. For further information regarding the models and the initialization parameters, the reader is referred to the shared files in the repository. This report also presents the dynamic behavior of each model. The response of such models to a load event is analyzed and matched with each model's features. A custom IEEE 39 bus case is employed for the FS and T-PSH simulations, while the VS-PSH is simulated on a simplified three-bus test system due to the computational complexity of the model. For the T-PSH, the steady-state and the switching between several operating modes are also studied in this work.

13 HYDRO ENERGY↗

Eaton High Impact Project (Cooperative Research and Development Final Report)

The NREL team will partner with Eaton to evaluate control strategies for managing Electric bus (E-bus) fleets for grid services. NREL will develop a replicable platform for evaluating EV fleet management and quantifying benefits from grid services. The proposal will cover the technology areas of solar, energy storage, mobility, and buildings.

33 ADVANCED PROPULSION SYSTEMS↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Analysis of PINNs for Power System Transient Stability

The integration of machine learning in power systems, particularly in stability and dynamics, addresses the challenges brought by the integration of renewable energies and distributed energy resources (DERs). Traditional methods for power system transient stability, involving solving differential equations with computational techniques, face limitations due to their time-consuming and computationally demanding nature. This paper introduces physics-informed Neural Networks (PINNs) as a promising solution for these challenges, especially in scenarios with limited data availability and the need for high computational speed. PINNs offer a novel approach for complex power systems by incorporating additional equations and adapting to various system scales, from a single bus to multi-bus networks. Our study presents the first comprehensive evaluation of physics-informed Neural Networks (PINNs) in the context of power system transient stability, addressing various grid complexities. Additionally, we introduce a novel approach for adjusting loss weights to improve the adaptability of PINNs to diverse systems. Our experimental findings reveal that PINNs can be efficiently scaled while maintaining high accuracy. Furthermore, these results suggest that PINNs significantly outperform the traditional ode45 method in terms of efficiency, especially as the system size increases, showcasing a progressive speed advantage over ode45.

97 MATHEMATICS AND COMPUTING↗

Enhancements and Deployment of the TDAQ System for the Mu2e Experiment

The Real Time Processing Systems Division at Fermilab has deployed new features to the Off-The-Shelf Data Acquisition framework (otsdaq) for the Mu2e experiment. The Mu2e experiment will search for the coherent neutrino-less conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement of 10,000 times over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable at present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system uses otsdaq as its online Data Acquisition System (DAQ) framework. otsdaq integrates the artdaq and art frameworks for event transfer, filtering, and processing. otsdaq is a web-based DAQ software suite focusing on flexibility and scalability and provides a multi-user interface accessible through a web browser. artdaq handles the entire data stream, which is read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events combined with the data flux coming from a cosmic-ray veto (CRV) system. Detector front-ends are configured through the PCIe bus by customized otsdaq plugins. The otsdaq slow controls infrastructure has been further developed using the experimental physics and industrial control system (EPICS) open-source platform for monitoring, controlling, alarming, and archiving. The detector control system (DCS) for Mu2e has been integrated into otsdaq. The production TDAQ and DCS system has been deployed at the experimental hall and is being debugged and optimized for experiment operations. We report on the feature enhancements and deployment of otsdaq for Mu2e.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electric Vehicle Charging Data Falsification Attacks Utilizing Behavioral Models

A charging station (CS) and its associated electric vehicle supply equipment (EVSE) and charging electric vehicle (EV) interactions are potential targets for data falsification attacks since CSs are typically unmanned public facilities that are connected to the internet and EVs incorporate the vulnerable CAN bus network, which are both susceptible to remote attacks. The research question being addressed is how is the EV owner and CS negatively affected by CAN bus EV battery current sensor and battery temperature sensor data falsification attacks. Negative effects include economic losses from reduced life span of the battery, battery thermal runaway and fire (and potential loss of surrounding structure), and reduced utilization of the CS due to delayed departure time (longer charging times).

25 ENERGY STORAGE↗

Next-Generation, High-temperature, High-frequency, High-efficiency, High-power-density Traction System

To meet performance and reliability requirements necessary for broader adoption of electric drive vehicles, the Electrical and Electronics Technical Team of the U.S. Drive partnership has established aggressive design goals for next-generation electric vehicle drivetrains. Specifically, the 2025 roadmap stipulates a 100 kW/L power density target and a $\$$2.7/kW cost target for power electronics, in addition to high-voltage operation (i.e., greater than 800 VDC). The additional targets for traction motor and the overall system performance impose further challenges on the power electronics design. For example, many high specific power machines have reduced iron content, and therefore reduced intrinsic filtering, thus requiring the inverter to supply a low-distortion drive current. These machines also typically have a high pole count, thus requiring drive current at a higher electrical frequency. Other motors, such as brush-less dc and switch reluctance machines, require a carefully-shaped, non-sinusoidal drive current (Yang, Shang, Brown, & Krishnamurthy, 2015), (Zhang, Bowman, O'Connel, & Haran, 2018), (Anderson, et al., 2018). Two- and three-level inverter topologies are the conventional framework for the power electronics design of the drivetrain, and some demonstrations have shown recent progress towards addressing cost, power density and efficiency goals (Gurpinar & Ozpineci, 2018), (Zhu, Kim, Chen, Erickson, & Maksimović, 2018), (Deshpande, Chen, Narayanasamy, Sathyanarayanan, & Luo, 2018), (Alizadeh, et al., 2019). However, an unconventional approach may be necessary to take the dramatic leap in power density necessitated by the roadmap—while simultaneously addressing the other system needs. Therefore, this project leverages the flying capacitor multilevel (FCML) topology, together with a scalable, modular approach, to address these needs. This type of hybrid converter has several advantages: lower voltage (i.e., less than 300 V) transistors can be used, energy-dense capacitors process most of the power, and the output current waveform is multilevel and exhibits a frequency multiplying effect—in other words, the output has reduced dv/dt and filtering requirements for the same high voltage dc bus. For example, in an electric vehicle with an 800 V bus, a 10-level FCML could leverage 100 V, commercially available GaN devices switching at 115 kHz to produce a ~1 MHz switching waveform (modulated according to the motor drive requirements) with one ninth of the dv/dt of a two-level converter. Prior work has already demonstrated promising performance and gravimetric power density figures for more electric aircraft applications (Pallo, Foulkes, Modeer, Coday, & Pilawa-Podgurski, 2018). This project leverages lessons learned to achieve the volumetric power density of 100 kW/L by employing advanced liquid cooling, address the 300,000 mile reliability challenge with redundant design, topology failure studies and online health monitoring, and reduce costs to $\$$2.7/kW through the use of low-cost GaN devices, modular converter assemblies, and modest modifications to traditional manufacturing methods. The project involved several hardware designs, each achieving increasing performance. At the conclusion of the project, a volumetric power density of 380 kW/L was achieved, in a 800V dc-ac converter, greatly surpassing even the aggressive target goal.

33 ADVANCED PROPULSION SYSTEMS↗

Application of Controller Area Network for Power Converter Network Monitoring and Control

This presentation explores the adaptation and implementation of CAN bus technology in a network of power converters, emphasizing its potential beyond automotive applications. In this system, multiple power converters can utilize the CAN bus to transmit diverse data types, each assigned specific message and node IDs. A central controller continuously monitors the status of each converter, ensuring efficient management and coordination of power distribution. Additionally, an individual CAN node is

Montoya, Armando Yassir↗

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗