Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Building Retrofit Strategies Using AutoBEM Under Future Weather Scenarios

This study evaluates the long-term effectiveness of energy conservation measures (ECMs) on building energy consumption using AutoBEM, a scalable modeling framework driven by the high-resolution Model America dataset. We simulated 18,951 buildings in Flagstaff, Arizona under four climate scenarios using Future Typical Meteorological Year (fTMY) weather files for six time periods spanning from 1980 to 2099. Six ECMs were analyzed across electricity and gas usage, including HVAC fuel-switching, insulation upgrades, and infiltration control. While some measures, such as reducing space infiltration by percentage, showed minimal or even negative impact on total energy savings at the aggregate level, they proved highly effective for specific building types. Conversely, HVAC electrification offers high gas reduction but shifts demand to electricity, highlighting critical trade-offs under different climate trajectories. Building-type-specific analysis under SSP5-RCP8.5 (2080–2099) revealed significant variation in ECM performance, underscoring the need for targeted retrofit strategies. This study demonstrates the power of combining fTMY projections with large-scale simulations to inform data-driven retrofit planning.

Chowdhury, Shovan [ORNL]↗

Developing a Database of Bio-based Materials for Building Envelope Applications

Oak Ridge National Laboratory (ORNL) has been funded by the Department of Energy (DOE) to help accelerate the introduction of building envelope materials that would reduce the carbon footprint of the buildings sector. The DOE’s Building Technologies Office has historically sought to resolve the knowledge gaps regarding the energy efficiency and moisture durability of building envelope systems and to develop the data, guidance, and tools needed to facilitate rapid industry adoption of high-performance, moisture-managed envelope systems. This project will help accelerate the widespread acceptance of a new generation of building materials developed specifically with the intent of reducing the carbon footprint of buildings. We have produced a database of hygrothermal transport properties on low embodied carbon building materials that can be added to energy and durability simulation tools. Properties that were measured include density, heat capacity, thermal conductivity as a function of temperature and relative humidity, moisture dependent permeance, and sorption isotherms as a function of relative humidity. These data sets were measured following consensus national standards using state-of-the-art facilities. The data has been compiled and is being made available to building designers who require these data to assess these new materials in their designs. We will publish the data and seek its addition to reference databases such as the ASHRAE Handbook of Fundamentals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

A sensitivity model for energy consumption in buildings. Part 1: Effect of exterior environment

A simple analytical model is developed for the simulation of seasonal heating and cooling loads of any class of buildings to complement available computerized techniques which make hourly, daily, and monthly calculations. An expression for the annual energy utilization index, which is a common measure of rating buildings having the same functional utilization, is derived to include about 30 parameters for both building interior and exterior environments. The sensitivity of a general class building to either controlled or uncontrolled weather parameters is examined. A hypothetical office type building, located at the Goldstone Space Communication Complex, Goldstone, California, is selected as an example for the numerical sensitivity evaluations. Several expressions of variations in local outside air temperature, pressure, solar radiation, and wind velocity are presented.

Lansing, F. L.↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OpenStudio®-MCP [SWR-26-035]

OpenStudio®-MCP is a Model Context Protocol (MCP) server that lets AI assistants perform building energy modeling through natural language. Rather than requiring users to learn the OpenStudio® SDK, EnergyPlus® scripting, or Ruby/Python automation, the server translates conversational requests into sequences of tool calls that create models, design HVAC systems, run simulations, and extract results — all within a single chat session. The server's 124 tools are organized into a skills architecture where each skill encapsulates a domain of building energy modeling (envelope, HVAC, loads, weather, simulation, results) behind typed, LLM-friendly interfaces. High-leverage operations like applying ASHRAE 90.1 baseline systems or generating standards-compliant typical buildings are exposed as single tool calls that internally wire dozens of OpenStudio® objects. Bundled measures from ComStock™ and Openstudio® -common-measures-gem are wrapped with dedicated tools and typed arguments rather than exposed through a generic measure interface, so AI models get consistent, error-resistant recipes without needing to discover measure arguments at runtime. A key design decision is structured results extraction: six SQL-based tools return surgical ~300–1,000 token responses (end-use breakdowns, envelope summaries, HVAC sizing, timeseries data) instead of requiring the AI to parse ~100K-token raw HTML reports, making iterative design exploration practical within context window limits. The codebase is designed as a reference implementation — explicit, well-commented, and modular — so that other simulation engines (EnergyPlus® standalone, TRNSYS, DOE-2) can use it as a template for building their own MCP servers.

Ball, Brian [National Laboratory of the Rockies (N↗

Conservation of Dry Air, Water, and Energy in CAM and Its Potential Impact on Tropical Rainfall

Abstract For the Community Atmosphere Model version 6 (CAM6), an adjustment is needed to conserve dry air mass. This adjustment exposes an inconsistency in how CAM6’s energy budget incorporates water—in CAM6 water in the vapor phase has energy, but condensed phases of water do not. When water vapor condenses, only its latent energy is retained in the model, while its remaining internal, potential, and kinetic energy are lost. A global fixer is used in the default CAM6 model to maintain global energy conservation, but locally the energy tendency associated with water changing phase violates the divergence theorem. This error in energy tendency is intrinsically tied to the water vapor tendency, and reaches its highest values in regions of heavy rainfall, where the error can be as high as 40 W m −2 annually averaged. Several possible changes are outlined within this manuscript that would allow CAM6 to satisfy the divergence theorem locally. These fall into one of two categories: 1) modifying the surface flux to balance the local atmospheric energy tendency and 2) modifying the local atmospheric tendency to balance the surface plus top-of-atmosphere energy fluxes. To gauge which aspects of the simulated climate are most sensitive to this error, the simplest possible change—where condensed water still does not carry energy and a local energy fixer is used in place of the global one—is implemented within CAM6. Comparing this experiment with the default configuration of CAM6 reveals precipitation, particularly its variability, to be highly sensitive to the energy budget formulation. Significance Statement This study examines and explains spurious regional sources and sinks of energy in a widely used climate model. These energy errors result from not tracking energy associated with water after it transitions from the vapor phase to either liquid or ice. Instead, the model used a global fixer to offset the energy tendency related to the energy sources and sinks associated with condensed water species. We replace this global fixer with a local one to examine the model sensitivity to the regional energy error and find a large sensitivity in the simulated hydrologic cycle. This work suggests that the underlying thermodynamic assumptions in the model should be revisited to build confidence in the model-simulated regional-scale water and energy cycles.

Harrop, Bryce E.↗

Data Driven Commercial Building Energy Code Compliance and Technology Inventory for New York City

Building Performance Standards (BPS) are gaining national traction. A BPS will require new processes in the design, construction, and operation of buildings that take the occupants into account and enable predictive analysis to ensure compliance with current and future GHG emissions caps. In New York City, most buildings over 25,000 square feet will be regulated by a BPS starting in 2024, regardless of whether it is new construction permitted under current energy codes or an existing building. This research is one of the first to begin the evaluation of a long-term series of building policies in the context of an open data ecosystem, in cooperation with city agencies. Existing building policies enacted in NYC have ranged from building energy benchmarking and labeling to energy audits to the regulation of GHG emission in buildings. Through the development of a dataset related to building technologies and energy consumption, this project can help to evaluate if meaningful conclusions can be drawn for the data that has been largely self-reported in compliance with city regulations. This project will also provide lessons learned from a deep dive into these types of datasets to provide best practices for municipalities or states seeking to embark on policies like those enacted in NYC. In addition, a Building Automation System (BAS) Stretch Standard of Care (SSOC) for owners, designers, and building operators will enable the measurement and predictive analysis of energy consumption and GHG emissions at the plant, system, or component level, in anticipation of regulated GHG limits on buildings based on energy use. The SSOC is expected to be suitable for use on a national level. The primary feature of an SSOC is a standardized format for a set of BAS points that can be used to control and to gather data from individual plants, systems, or components that are related to building energy consumption. This project examined how measurements compare to prescriptive or simulation-based energy code targets, finding little correlation between predictive 8760-hour energy modeling and actual energy consumption for a small sample (n=27) of buildings constructed after 2015. Other analysis found that, while large multifamily housing (MFH) buildings showed a general trend similar to predicted reductions in energy use from the implementation of model commercial energy codes, this trend was not evident in the office, K-12 school, and hotel use groups in NYC. No upward or downward trends in energy consumption were found when buildings were grouped by size. Energy audit data were analyzed and it appears that there is bias by audit company on measures recommended to clients. Further research should be performed to cross-analyze this with other attributes, such as building size, vintage, and number of stories. Analysis found that for 281 buildings that were permitted and completed after 2015 and had submitted benchmarking data in 2022, between 81% and 96% (by use group) were found to be in compliance with the 2024 to 2029 NYC BPS emission caps, and between 55% and 89% were in compliance with the 2030-2034 caps. This work is beneficial to the public in helping policymakers and building stakeholders better understand the wide-ranging implications of a BPS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions concerning agent-based modeling of occupant behavior for energy and environmental performance of buildings

We report the complexity of occupant behavior is one of the major contributors to uncertainty in building performance simulation. Agent-based modeling (ABM), a computational simulation technique, has gained attention in the occupant modeling field due to its capability and flexibility to capture the heterogeneity and dynamics of human behavior and the emergent effects. While multiple efforts in the past decade have demonstrated the usefulness of the ABM approach for simulating occupants and their impacts on building performance, several crucial matters in the ABM research still remain unexplored. This paper presents ten questions that highlight the most important issues regarding ABM research and applications for occupant behavior in the context of building performance simulation. The questions and answers aim to provide insights into current and future ABM research, and more importantly to inspire new significant questions from young researchers in the field. This research is part of the IEA EBC Annex 79 project, occupant-centric building design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refining seasonal performance metrics for room air-conditioning in emerging markets: Integrating building simulations with real-world equipment performance data

Buildings significantly impact worldwide energy consumption, emphasizing the need to reduce the cooling energy demand, especially in warm climates. Minimum energy performance standards (MEPS) and seasonal performance metrics such as the Cooling Seasonal Performance Factor (CSPF) are crucial for improving room air conditioning (RAC) efficiency. However, challenges remain, particularly in emerging markets like Brazil, where seasonal performance metrics have recently been introduced. This study assesses the factors influencing country-level seasonal efficiency metrics and proposes a framework to refine these calculations by considering local climates and expected RAC usage in real-world households via building simulations. Key considerations include outdoor air temperature binning for different climates, RAC usage patterns (i.e., daytime and nighttime usages), envelope thermal performance of households, and urban heat island (UHI) effects. The results reveal that CSPF values can vary significantly based on climate conditions, with observed CSPF ranging from 4.10 to 11.59 Wh/Wh across 577 Brazilian climates. The inclusion of UHI effects led to a reduction in CSPF values by up to 29% during nighttime operations in hot urban areas. Additionally, building envelope efficiency showed contrasting impacts on RAC performance, with CSPFs reaching up to 15.35 Wh/Wh under specific optimized conditions. These findings highlight the need for transparent policymaking in RAC performance databases, facilitating the application of approaches like those proposed in this study and supporting diverse stakeholders in decision-making.

Bavaresco, Mateus↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MBMS1.0: An Open-Source Code for Modeling and Simulation of Membrane-Based Dehumidification and Energy Recovery

Membrane-based dehumidification is currently being considered as a promising solution for the building application due to its low cost and very limited energy consumption. Developing a simple and efficient open-source code simulation tool is important for boosting the optimization and evaluation of such device in HVAC community. This paper reports a first-order physics based model which accounts for the fundamental heat and mass transfer of humid-air vapor at feed side to flow stream at permeate side. The current model comprises two membrane mass transfer submodels (i.e. microstructure model and performance map model); and it adopts a segment-by-segment methodology for discretizing heat and mass transfer governing equations. The model is capable of simulating both dehumidifiers and energy recovery ventilators with parallel-flow cross-flow, and counter-flow configurations. The model was validated with the measurements at appropriate device. The practices in dehumidification and energy recovery exchangers are also discussed. The model and open-source codes are expected to become a solid fundament for developing a more comprehensive and accurate membrane-based dehumidification in the future.

Gao, Zhiming↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗