Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Melt Crystallization of CsF from Alkali Fluorides

Fractional melt-crystallization is a technique used to separate components in a multicomponent liquid mixture through controlled cooling. In fiscal year (FY) 2023, this technique was successfully used to separate CsCl from LiCl-KCl. This demonstrated a potential route for concentrating electrorefiner fission product waste streams in pyrochemical fuel cycles, building on previous work that developed the melt-crystallization system for fission product removal from LiCl-based electrolytes used for oxide reduction. This work investigated whether a thermally controlled process of a solid-liquid separation process could effectively remove CsF from LiF-NaF-KF (FLiNaK)-CsF salt for MSR fuel cycle applications. The designed process aimed to recover purified LiF-NaF-KF salt as solid precipitates while concentrating CsF to a remaining salt heel. This concentrated CsF can then be immobilized during a salt waste stream treatment operation, minimizing waste volume.

36 MATERIALS SCIENCE↗

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

Dissolution of Additively Manufactured Mo Disks and Structures for Accelerator Based Production of Mo-99

The press-and-sinter approach for production of Mo targets has been successfully tested and demonstrated. The main advantage of this process is that it uses readily available technology and tools that have been tuned for production of various metal and metal oxide targets. However, certain target design specifications, such as dimensional accuracy of the diameter and thickness of the disks, are required for proper fit into a target holder and therefore place strict tolerances on sintered Mo disks intended for accelerator production. Furthermore, having a target composed of multiple disks poses certain challenges for post-irradiation processing, where there is a potential for spillage of individual disks during the manipulation for dissolution inside a processing hot cell. Additive manufacturing (AM), also referred to as 3D printing, provides capabilities to design and build a single-piece Mo target that provides the opportunity for better geometry for optimized production of Mo-99, improved cooling capability, and safer post-irradiation handling. A drawback of AM Mo structures is roughness of finished surfaces, which could reduce the effectiveness of gas cooling systems. Process development for AM Mo structures using selective laser melting is described in work by Gibson and Lowden. For post-irradiation processing, it is important to look at the dissolution behavior of AM Mo structures in comparison to readily dissolved press-and-sinter Mo targets. The dissolution behavior of press-and-sinter targets has been well documented in our previous reports. In this report, we discuss results of dissolution experiments conducted with AM Mo disks and structures (provided by Oak Ridge National Laboratory [ORNL]) in 50% hydrogen peroxide (H 2 O 2 ).

36 MATERIALS SCIENCE↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Cooling Rate and Thermal Mass on Supercooling in a Salt-Hydrogel Complex for Thermal Energy Storage

Glauber’s salt is a promising phase change material for building thermal management because of its high latent heat, acceptable melting temperature of 32.3 °C for indoor air1,2. Despite these advantages, the practical application of Glauber’s salt in thermal energy storage systems is still challenging due to supercooling and phase segregation1–3. Here, we report the impact of temperature ramp rate and thermal mass on the supercooling of Glauber’s salt through the DSC and T-history experiment. The ramp rate effect was studied with a wide range of ramp rates in 1 to 10 °C/min in DSC and 1 to 4 °C/min in the T-history experiment. The thermal mass effect was investigated by comparing DSC and T-history experiment. The latent heat was also analyzed for different ramp rates and thermal mass conditions. The melting temperatures of Glauber’s salt from the two techniques were identical while freezing temperatures were different because of the thermal mass effect. During freezing in the T-history experiment, the latent heat was reduced by around 75% to the latent heat in melting due to supercooling and phase segregation. To overcome this bottleneck, we developed a novel hydrogel complex that reduces the supercooling and prevents phase segregation to maintain volumetric energy density for 100 cycles. Thermodynamic analysis accounting for composition shows that a higher salt composition can further enhance the volumetric energy storage density. For example, a 10% increase in the weight percentage of salt leads to about 50% enhancement in volumetric energy storage density. References: 1. D. R. Biswas, Solar Energy. 19, 99–100 (1977). 2. S. M. Hasnain, Energy Conversion and Management. 39, 1127–1138 (1998). 3. Byung Chul Shin, Sang Done Kim, P. Won-Hoon, Energy. 14, 921–930 (1989).

inorganic, thermodynamics↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

Toward a life cycle approach for classifying the toxicity of refrigerants

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world (IEA, 2018). Over the next three decades, as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. While technological advances have led to increased cooling capacity and safer refrigerants over the years, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. Further, because of ongoing and pending policy and regulatory changes to avert ozone depletion and global climate change, there is an increasing focus on adopting compounds that are efficient at cooling while also reducing emissions and other adverse environmental impacts.

54 ENVIRONMENTAL SCIENCES↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Surface Merging Technique to Design GA-Optimized Heat Sinks

High-power density inverters require efficient and small heat dissipation systems. For liquid cooling systems, an effective heat sink design is important to enable higher heat transfer and keep the pressure drop within reasonable limits. A heat sink geometry generated from an extruded, 1D fast Fourier transform can achieve more even temperature distribution and improved heat transfer than a conventional heat sink. Building on this concept, this paper proposes a new heat sink geometry creation algorithm. Instead of one plane profile being extruded, multiple plane profiles, each created from the fast Fourier transform method, are subsequently merged by smooth surfaces along the flow direction of the heat sink. Thus, a 3D heat sink geometry is created that enables 3D coolant flow and efficient heat transfer. The volume of this design was reduced by 50% compared with pin fin heat sinks. Compared with extruded 1D fast Fourier transform heat sinks, the proposed design showed an approximately 5% device temperature reduction and a 20% pressure drop reduction.

Barua, Himel↗

Design, Prototyping, Fabrication and Test of the Mu2e AC-Dipole Magnet

Fermilab Magnet Systems is building three High-frequency AC-Dipole Magnets for the Mu2e experiment at Fermilab. These magnets are composed of three single-loop one-meter-long ferrite loaded segments. The excitation consists of a copper tube, which is also used as a means for its cooling with the inherited challenges of Voltage and Frequency uncoupling. These magnets are designed to operate either at 300 kHz or 4.4 MHz via resonance tuning. Following the completion of the design, prototyping, and analysis phases, all ferrites and other components were procured, and the magnets were fabricated to meet vacuum compatibility requirements using strict procedures. Each magnet undergoes thorough baking and testing before being installed in the experiment. This paper discusses the magnets' role in proton background suppression as it represents a unique and essential device for the Mu2e experiment at Fermilab. We present the magnet design choices, modeling approach, and the challenges encountered during fabrication. Additionally, we outline the power supply driving mechanism, the testing that was performed, and our results.

Elementi, Luciano [Fermilab] (ORCID:00000002766372↗

Thermal Energy Storage in Commercial Buildings

Space heating and cooling account for as much as 40% of energy used in commercial buildings. Aligning this energy consumption with renewable energy generation through practical and viable energy storage solutions will be pivotal in achieving 100% clean energy by 2050. Integrated on-site renewable energy sources and thermal energy storage systems can provide a significant reduction of carbon emissions and operational costs for the building owner.

buildings energy storage↗

Low-Temperature Geothermal Resources: Relevant Data and PFA Methods to Reduce Development Risk: Preprint

This project is part of a larger national effort focused on demonstrating the multi-faceted value of integrating low-temperature geothermal resources into national decarbonization strategies and community energy plans. Low-temperature geothermal resources are defined as reservoirs-natural or engineered-with temperatures < 150 degrees C. While the focus in the NREL effort is on geothermal heating and cooling (GHC), resources at the upper end of this temperature range can also be used for small-scale power generation. However, low-temperature geothermal resources have not been studied as extensively as higher-temperature geothermal resources. We identified three major classes of low-temperature geothermal play types: sedimentary basins, orogenic systems, and radiogenic systems. We developed workflows for evaluating the potential of these resources building off the Play Fairway Analysis (PFA) approach to de-risking geothermal exploration. This PFA-based approach to low-temperature geothermal resources includes: (1) identifying relevant data; (2) grouping and weighting of relevant datasets into PFA criteria (e.g., geological, risk, economic criteria); (3) developing favorability or common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection; and (4) estimating electric power generation and heating potential at those locations using the GeoRePORT Resource Size Assessment Tool. This project will facilitate future deployment of GHC by providing data, tools, and workflows applicable to low-temperature geothermal resources.

favorability maps↗

Low-Temperature Geothermal Resources: Relevant Data and PFA Methods to Reduce Development Risk

This project is part of a larger national effort focused on demonstrating the multi-faceted value of integrating low-temperature geothermal resources into national decarbonization strategies and community energy plans. Low-temperature geothermal resources are defined as reservoirs-natural or engineered-with temperatures < 150 degrees C. While the focus in the NREL effort is on geothermal heating and cooling (GHC), resources at the upper end of this temperature range can also be used for small-scale power generation. However, low-temperature geothermal resources have not been studied as extensively as higher-temperature geothermal resources. We identified three major classes of low-temperature geothermal play types: sedimentary basins, orogenic systems, and radiogenic systems. We developed workflows for evaluating the potential of these resources building off the Play Fairway Analysis (PFA) approach to de-risking geothermal exploration. This PFA-based approach to low-temperature geothermal resources includes: (1) identifying relevant data; (2) grouping and weighting of relevant datasets into PFA criteria (e.g., geological, risk, economic criteria); (3) developing favorability or common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection; and (4) estimating electric power generation and heating potential at those locations using the GeoRePORT Resource Size Assessment Tool. This project will facilitate future deployment of GHC by providing data, tools, and workflows applicable to low-temperature geothermal resources.

favorability maps↗

Sensor Incipient Fault Impacts on Building Energy Performance: A Case Study on a Multi-Zone Commercial Building

Existing studies show sensor faults/error could double building energy consumption and carbon emissions compared with the baseline. Those studies assume that the sensor error is fixed or constant. However, sensor faults are incipient in real conditions and there were extremely limited studies investigating the incipient sensor fault impacts systematically. This study filled in this research gap by studying time-developing sensor fault impacts to rule-based controls on a 10-zone office building. The control sequences for variable air volume boxes (VAV) with an air handling unit (AHU) system were selected based on ASHRAE Guideline 36-2018: High-Performance Sequences of Operation for HVAC Systems. Large-scale simulations on cloud were conducted (3600 cases) through stochastic approach. Results show (1) The site energy differences could go –3.3% lower or 18.1% higher, compared with baseline. (2) The heating energy differences could go –66.5% lower or 314.4% higher, compared with baseline. (3) The cooling energy differences could go –11.5% lower or 65.0% higher, compared with baseline. (4) The fan energy differences could go 0.15% lower or 6.9% higher, compared with baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗