At least 307 records · Page 17

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending Classification Algorithms to Case-Control Studies

Classification is a common technique applied to ’omics data to build predictive models and identify potential markers of biomedical outcomes. Despite the prevalence of case-control studies, the number of classification methods available to analyze data generated by such studies is extremely limited. Conditional logistic regression is the most commonly used technique, but the associated modeling assumptions limit its ability to identify a large class of sufficiently complicated ’omic signatures. We propose a data preprocessing step which generalizes and makes any linear or nonlinear classification algorithm, even those typically not appropriate for matched design data, available to be used to model case-control data and identify relevant biomarkers in these study designs. We demonstrate on simulated case-control data that both the classification and variable selection accuracy of each method is improved after applying this processing step and that the proposed methods are comparable to or outperform existing variable selection methods. Finally, we demonstrate the impact of conditional classification algorithms on a large cohort study of children with islet autoimmunity.

59 BASIC BIOLOGICAL SCIENCES↗

Rejoinder to “Graphics to facilitate informative discussion and team decision-making”

We would like to thank Dr Dae-Heung Jang and Dr Jennifer Van Mullekom for their thoughtful discussions. We are encouraged that they share our vision for highlighting and expanding the role of graphics for improving team discussion and decision-making. Here we would like to respond to several comments that they made in their discussions: (1) how the availability of the third dimension in graphics can improve team members' ability to properly visualize and connect with the data, (2) the importance of developing dynamic and interactive graphics to allow exploration of questions as they emerge during the discussion, (3) the role of process and relationships in helping reach good decisions based on the developed objectives, and (4) the benefits of building a body of case studies on which those new to the methods can draw understanding.

99 GENERAL AND MISCELLANEOUS↗

NEFTSec: Networked federation testbed for cyber-physical security of smart grid: Architecture, applications, and evaluation

As today's power grid is evolving into a densely interconnected cyber-physical system (CPS), a high fidelity and multifaceted testbed environment is needed to perform cybersecurity experiments in a realistic grid environment. Traditional standalone CPS testbeds lack the ability to emulate complex cyber-physical interdependencies between multiple smart grid domains in a real-time environment. Therefore, there are ongoing research and development (R&D) efforts to develop an interconnected CPS testbed by sharing geographically dispersed testbed resources to perform distributed simulation while analysing simulation fidelity. This paper presents a networked federation testbed for cybersecurity evaluation of today's and emerging smart grid environments. Specifically, it presents two novel testbed architectures, including cyber federation and cyber-physical federation, identifies R&D applications, and also describes testbed building blocks with experimental case studies. It also presents a novel co-simulation interface algorithm to facilitate distributed simulation within cyber-physical federation. The resources available at the PowerCyber CPS security testbed at Iowa State University (ISU) and the US Army Research Laboratory are utilised to develop this platform for performing multiple experimental case studies pertaining to wide-area protection and control applications in power system. Finally, experimental results are presented to analyse the simulation fidelity and real-time performance of the testbed federation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lights, Camera, Action ... and Cooling - The case for centralized low carbon energy at Fox Studios

Fox Studios partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit two production stages and one of its central cooling plants, to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program. Although this case study reports expected savings arising from proposed design recommendations for a unique building type and the unusual load characteristics associated with its use, the EEMs implemented for the central plant are applicable to any large campus, office and higher education facility. The intent is that by making the energy-efficiency measures (EEMs) set that were assessed as cost-effective from this project applicable to a larger number of buildings on the campus Fox Studios will be able to implement an integrated campus-wide energy strategy for the long term. The significant challenges for this project in the design phase included identifying how to assess and analyze multiple system types, develop a coherent strategy for assessment and analysis, implement the measurement and verification activities to collect the appropriate data (in terms of capturing ‘normal’ operating characteristics and granularity) and determine the best approach to providing cooling to the site buildings based on the nature of existing systems and the expected improvement in energy performance of the central cooling plant. The analytical framework adopted provides a blueprint for similar projects at other large commercial building campuses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Algal Biomass Production via Open Pond Algae Farm Cultivation: 2023 State of Technology and Future Research

The annual State of Technology (SOT) assessment is an essential activity for platform research conducted under the Bioenergy Technologies Office (BETO). It allows for the impact of research progress (both directly achieved in-house at the National Renewable Energy Laboratory [NREL] and furnished by partner organizations) to be quantified in terms of economic improvements in the overall biofuel production process for a particular biomass processing pathway, whether based on terrestrial or algal biomass feedstocks. As such, initial benchmarks can be established for currently demonstrated performance, and progress can be tracked toward out-year goals to ultimately demonstrate economically viable biofuel technologies. NREL's algae SOT benchmarking efforts historically focused both on front-end algal biomass production and separately on back-end conversion to fuels through NREL's "combined algae processing" (CAP) pathway. The production model is based on outdoor long-term cultivation data, enabled by comprehensive algal biomass production trials conducted under the Development of Integrated Screening, Cultivar Optimization, and Verification Research (DISCOVR) consortium efforts, driven by data furnished by Arizona State University (ASU) at the Arizona Center for Algae Technology and Innovation (AzCATI) testbed site. The CAP model is based on experimental efforts conducted primarily under NREL research and development projects. This report focuses on front-end algal biomass production, documenting the pertinent algal biomass cultivation parameters that were input to the NREL open pond algae farm model. Through partnerships under DISCOVR, collaborators at ASU furnished details on cultivation performance metrics including biomass productivity and harvest densities for recent growth trials done at the AzCATI site. The resulting biomass productivity was calculated at 16.7 g/m 2 /day (ash-free dry weight [AFDW], annual average) for seasonal cultivation of Picochlorum celeri TG2 and Monoraphidium minutum 26B-AM biomass strains at the ASU site. Picochlorum celeri achieved the best productivity from April to September, with Monoraphidium minutum 26B-AM being used between October and March. Tetraselmis striata LANL1001, usually part of the strain rotation in previous cultivation SOTs, was supplanted by Monoraphidium minutum 26B-AM in this year's outdoor cultivation trials. Finally, building from an industry case study presented in the 2022 SOT report, in the Appendix of this report we provide an update on further improved data furnished by an industry collaborator and resultant impacts on economics reflecting several seasonal scenarios. This case study provides a supplementary datapoint on work being performed elsewhere with a more dedicated focus on improved compositional quality, producing biomass enriched in lipids as may be more optimal for conversion upgrading to fuels and products.

09 BIOMASS FUELS↗

Occupant Behavior for Energy Conservation in Commercial Buildings: Lessons Learned from Competition at the Oak Ridge National Laboratory

Accompanying efforts worldwide to deploy sustainable building technologies shows a pressing need for expanded research on occupant behavior. Discourse is lacking concerning drivers of occupant behavior for energy conservation, especially in the case of commercial buildings. This paper explores potential determinants of occupant behavior for energy conservation in commercial buildings. This is investigated in a case study of a two-month energy conservation competition involving eight office buildings at the Oak Ridge National Laboratory. Four buildings achieved energy savings based on the previous year’s baseline. Potential challenges and success factors of occupant behavior for energy conservation during the competition were explored based on an explanatory research design incorporating energy data, participant interviews, and surveys. The findings suggest that both social and technological aspects may be important drivers of energy conservation. The determinants of occupant behavior for energy conservation in commercial buildings suggested for further research include bottom-up involvement, stakeholder relationship management, targeted information, real-time energy visualization, and mobile social platforms. This paper presents initial implications, with a need for further research on these propositions and on their impacts on occupant behavior. This paper aims to contribute to both academia and practitioners in the arena of commercial building sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulator for concurrent processing data flow architectures

A software simulator capability of simulating execution of an algorithm graph on a given system under the Algorithm to Architecture Mapping Model (ATAMM) rules is presented. ATAMM is capable of modeling the execution of large-grained algorithms on distributed data flow architectures. Investigating the behavior and determining the performance of an ATAMM based system requires the aid of software tools. The ATAMM Simulator presented is capable of determining the performance of a system without having to build a hardware prototype. Case studies are performed on four algorithms to demonstrate the capabilities of the ATAMM Simulator. Simulated results are shown to be comparable to the experimental results of the Advanced Development Model System.

Malekpour, Mahyar R.↗

Technology Solutions Case Study: Design Guidance for Passive Vents in New Construction, Multifamily Buildings

In an effort to improve indoor air quality in high-performance, new construction, multifamily buildings, dedicated sources of outdoor air are being implemented. Passive vents are being selected by some design teams over other strategies because of their lower first costs and operating costs. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings constructed eight steps, which outline the design and commissioning required for these passive vents to perform as intended.

building america↗

Smart building management vs. intuitive human control—Lessons learnt from an office building in Hungary

We report that smart building management and control are adopted nowadays to achieve zero-net energy use in buildings. However, without considering the human dimension, technologies alone do not necessarily guarantee high performance in buildings. An office building was designed and built according to state-of-the-art design and energy management principles in 2008. Despite the expectations of high performance, the owner was facing high utility bills and low user comfort in the building located in Budapest, Hungary. The objective of the project was to evaluate the energy performance and comfort indices of the building, to identify the causes of malfunction and to elaborate a comprehensive energy concept. Firstly, current building conditions and operation parameters were evaluated. Our investigation found that the state-of-the-art building management system was in good conditions but it was operated by building operators and occupants who are not aware of the building management practice. The energy consumption patterns of the building were simulated with energy modelling software. The baseline model was calibrated to annual measured energy consumption, using actual occupant behaviour and presence, based on results of self-reported surveys, occupancy sensors and fan-coil usage data. Realistic occupant behaviour models can capture diversity of occupant behaviour and better represent the real energy use of the building. This way our findings and the effect of our proposed improvements could be more reliable. As part of our final comprehensive energy concept, we proposed intervention measures that would increase indoor thermal comfort and decrease energy consumption of the building. A parametric study was carried out to evaluate and quantify energy, comfort and return on investment of each measure. It was found that in the best case the building could save 23% of annual energy use. Lastly, future work includes the follow-up of: occupant reactions to intervention measures, the realized energy savings, the measurement of occupant satisfaction and behavioural changes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A SIMPLIFIED ENERGY MODELING APPROACH FOR BUILDINGS

This paper introduces simplified energy modeling (SEM) approaches using DOE2 and EnergyPlus and proposes a validation method for simplified energy modeling. Simplified energy modeling can allow more design teams and owners to leverage the power of energy modeling to inform their designs and lead to greater energy savings and a lower first cost because the technologies and design strategies can be thoroughly tested against models before the decisions are made. By starting a discussion on how to develop simplified energy modeling approaches and methods to validate results, we hope to increase innovation in energy modeling software while decreasing variation between modelers. Simplified modeling is not yet widely accepted because it is unclear if the simplifications reduce the accuracy of the results. By starting an industry dialogue on a testing method for these modeling approaches, we hope to aid adoption of more streamlined tools when they can be shown to provide similar accuracy to more detailed tools. This paper proposes a method to test simplified energy modeling programs against the DOE prototype buildings. It builds on the testing procedure established for simulation engines by ASHRAE Standard 140. By comparing whole building and end use results from the accepted prototype buildings to any simplified modeling approach across multiple building types and climate zones we can determine if the simplifications create unwarranted error. We will present the SEM approach and results for a case study validation for a sample building types in 16 US climate zones from two such simplified energy modeling tools.

Energy Modeling, 90.1 Appendix G, Asset Score Tool↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Blocks for Secure and Prosperous Defense Critical Supply Chains: A Case Study from Microelectronics

Securing defense-critical supply chains, built on resilient and sustainable microelectronics fabrication and deployment, is a national imperative and one that requires an investment in basic and applied research, development, and deployment into industries in (and out of) the Defense Industrial Base (DIB). Critical next steps include the development of pilots for revolutionary concepts in a new formal verification model and the Cyber-Physical Passport (CPP) concept for chain of custody. Critical infrastructure leadership should take action with a sense of urgency. Working in conjunction with the Under Secretary for Acquisition and Sustainment, the Assistant Secretary of Defense for Research and Engineering should establish pilot programs with the Defense Advanced Research Projects Agency and the service labs to build and test both concepts in legacy and new system development.. Additionally, the Pentagon may be aware that an existing Manufacturing Innovation Institute is piloting, with the semiconductor industry, cyber innovations to provide verifiable security properties and guarantees of physical functions to build a more cyber secure, resilient and efficient micro-electronics supply chain.

99 GENERAL AND MISCELLANEOUS↗