Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Energy Performance Validation of a Gaseous Air Cleaning Technology for Commercial Buildings

The U.S. Department of Energy (DOE) Building Technologies Office Commercial Building Integration group conducts evaluations of new energy efficiency technologies as part of the High Impact Technology Catalyst program. The subject of this field validation project is an air cleaning technology that removes gaseous contaminants from indoor air to reduce outdoor air ventilation requirements. Reducing the volume of outdoor air required reduces heating, ventilating, and air conditioning (HVAC) loads and can provide significant energy savings for some buildings in certain climates. The technology, called the HLR (HVAC Load Reduction), was developed by enVerid. The technology uses a solid regenerable sorbent material that was developed by DOE's National Energy Technology Laboratory and licensed to the vendor for this application. The sorbent material was originally developed to adsorb carbon dioxide (CO2); the vendor continued to develop the sorbent and the overall system so that it can also remove volatile organic compounds (including aldehydes), carbon monoxide, ozone, and particulate matter 2.5 micrometers in diameter or smaller (PM2.5) from the air. This material has low regeneration temperature requirements, and its sorption properties are unaffected by humidity levels, both of which are beneficial for building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transactive HVAC Agent - Design and Performance Evaluation

Transactive energy systems are playing an increasingly important role in the efficient and reliable marketbased operation of the power grid. Since a significant portion of the residential building energy consumption is from heating ventilation and air conditioning (HVAC) systems, HVAC is one of the most promising resources to provide load flexibility. However, utilizing HVAC flexibility to provide various grid services while simultaneously maintaining consumer comfort and cost-reductions is challenging. This paper presents a design of a transactive HVAC agent (T-HVAC) to be used as a supervisory control for the HVAC system that can simultaneously ensure comfort and cost-reduction. In particular, the T-HVAC a) estimates HVAC thermal dynamics, b) ensures optimal operations of the HVAC system, and c) participates into markets, and d) implements a market-based control via controlling the thermostat temperature set-point. The T-HVAC performance is demonstrated through multiple scenarios and illustrations.

Demand flexibility, distribution system, HVAC, Tra↗

Temporal Characterization and Filtering of Sensor Data to Support Anomaly Detection

Here, we present an approach for characterizing complex temporal behavior in the sensor measurements of a system in order to support detection of anomalies in that system. We first characterize typical behavior by extending a hidden Markov model-based approach to time series alignment. We then use a trace of that learned behavior to develop a particle filter that enables efficient estimation of the filtering distribution on the state space. This produces filtered residuals that can then be used in an anomaly detection framework. Our motivating example is the daily behavior of a building’s heating, ventilation, and air conditioning (HVAC) system, using sensor measurements that arrive every minute and induce a state space with 15,120 states. We provide an end-to-end demonstration of our approach showing improved performance of anomaly detection after application of alignment and filtering compared to the unaligned data. The proposed model is implemented as a computationally efficient R package alignts (align time series) built with R and Fortran 95 with OpenMP support.

47 OTHER INSTRUMENTATION↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Automated Fault Detection and Diagnosis Records as an Indicator of HVAC Fault Prevalence: Methodology and Preliminary Results

Faults in commercial buildings can cause energy waste and other performance problems such as reduced occupant comfort, reduced equipment longevity, and increased noise. However, it is currently unknown how commonly faults occur in different equipment types. A method has been developed to estimate the prevalence of faults in air handling units, air terminal units, and rooftop units. This method includes two types of data. The first is data from several automated fault detection and diagnostics (AFDD) software technologies. This type of data provides a large sample that represents a wide range of building types, geographical locations, and equipment types. It includes fault diagnoses from thousands of buildings around the United States, as well as anonymized metadata describing the building and equipment characteristics. The number of fault records is in the order of 107. However, despite the size and richness of the data sample, this data contains some degree of inaccuracy, i.e., false positive and false negative findings. Therefore, the study includes a second type of data, coming from manual inspection of buildings that have had the same AFDD methods applied to them (from the commercial AFDD offerings). Since the field tests are conducted in buildings with AFDD-generated fault prevalence data, they can be combined with the larger sample size to provide insight into the potential biases or lower sensitivity of the AFDD data. Once a library of fault prevalence data is built, it will be studied to provide further insight into the drivers of fault prevalence, for example, whether prevalence is correlated with building type, geographical location (which is tied to climate and to utility rates), building size, etc. This paper describes the methods developed for this study and illustrates them with preliminary data. It discusses some of the challenges of harmonizing disparate outputs from multiple AFDD vendors, application of a unifying fault taxonomy, and fault prevalence metrics.

Ebrahimi Fakhar, Amir↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan↗

A Real-time Agent Based Optimization and Control Approach for Residential Building Heating Ventilation and Air Conditioning Systems

The prevalence of the loT (Internet of Things) is fostering the development of new control options and decision making that was not previously available. This is creating a wealth of opportunities for real-time control approaches and systems that can optimize for a common goal. This paper presents a smart residential neighborhood with optimization at the residential level utilizing a system of agents. The optimization utilizes information and modeling to optimize variable speed HVAC real-time operation in actual residential buildings. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Hall, Joni↗

Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China

Increasing envelope facet albedos considerably reduces solar heat gain, thus yielding building cooling energy savings. Few studies have explored the potential benefits of utilizing cool coatings on building envelopes (“cool-coated buildings”) based on life-cycle cost analysis. A holistic approach integrating the field testing, building energy simulation, and a 20-year life-cycle-based optimization was developed to explore cool-coated building performance and the maximum net savings of optimal building envelope retrofit and design. Experimental results showed that applying cool coatings to a west wall of an office building in Chongqing, China reduced its exterior surface temperature by up to 9.3 °C in summer. Additionally, simulation results showed that in Chongqing, making the roof and walls cool could reduce annual HVAC electricity use by up to 11.9% in old buildings (with poorly insulated envelopes) and up to 5.9% in new buildings. Retrofitting old buildings with a cool roof provided the net savings per modified area with present values up to 42.8 CNY/m2; retrofitting a new building with a cool roof or cool walls was not cost-effective. Optimizing both envelope insulation and envelope albedo can achieve 5.6 times the net savings of optimizing the insulation only, and 1.6 times that of optimizing albedo only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

Microcam: A Low Power and Privacy Preserving Multi-modal Platform for Occupancy Detection (Final Report)

Heating, ventilation, and air conditioning (HVAC) consumes a significant portion of the energy used in buildings. Much of this is wasted energy, used when buildings are either not occupied at all, or occupied well under their maximum design conditions. This project has focused on residential occupancy detection to autonomously control HVAC systems and save energy. Limitations of existing occupancy sensors include one or more of the following: (i) they employ sensors or algorithms that are not able to detect stationary occupants; (ii) they cannot classify the source of the motion (such as a pet); (iii) depending on the camera resolution and employed algorithms, they do not allow for embedded or onboard computation, and require external or cloud-based processing; (iv) many algorithms developed for camera-based systems are sensitive to lighting changes, and thus prone to missed detections or false alarms; (v) Most existing systems depend on adjustment of settings for different scenarios, complicating self-commissioning; (vi) they cannot provide high enough accuracy; (vii) they are costly; (viii) they are not battery-powered, thus limiting ease of use and installation. In this project, Syracuse University and its partner SRI have developed a low-cost, high accuracy, standalone residential occupancy sensing platform, referred to as the MicroCam, to address all of the aforementioned challenges. MicroCam can operate on typical alkaline batteries without relying on the “cloud” or external computing resources, and consists of low-power, Artificial Intelligence (AI)-based, IoT platforms. Each platform has multi-modal sensors and can process motion, audio and video data, and send binary occupancy result to a lead platform. All sensor data is processed locally on platforms, and the only transmitted data is the binary occupancy state. In addition, preliminary work has been done on images wherein occupants are not discernable. Thus, MicroCam is a standalone solution preserving privacy of the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cluster analysis of occupancy schedules in residential buildings in the United States

The energy performance of residential buildings significantly depends on the building occupants’ behavior, which can be highly variable. When the heating, ventilation and air conditioning (HVAC) system is controlled based on the presence or absence of occupants in a building, occupant behavior is of even further importance to its energy performance. In current practice, building energy simulation tools generally use a single occupancy profile to represent the building’s occupancy schedule, the schedule of which is considered to be the same, regardless of the type of household being modeled. Thus, there is significant potential for improvement to allow for more flexibility and accuracy in calculation of occupancy. The objective of this study is to assess the variations in the typical types of occupancy schedules followed by the U.S. population using cluster analysis. American Time Use Survey data, which statically represents the overall U.S. population’s activities, across 12 years (2006–2017), is used. The ATUS data is segregated into smaller groups based on age and weekday/weekend, then divided into activities that are considered “at home” and “away from home”, which are mapped to the presence or non-presence of occupants in the home. Cluster analysis is then used to identify common types of occupancy schedule patterns for each age group. Three main types of patterns are obtained from cluster analysis for each age group, which together represent approximately 88% of people in the United States. The output of the cluster analysis is further analyzed to evaluate the variation in characteristics, including the number of times leaving home, time of day when leaving the home, and the timespan of absence from the home. The results of this study provide detailed insights on how typical occupants in the United States spend their time in residential spaces which can be used to create occupancy profiles for residential buildings. Finally, these occupancy profiles could be utilized inform an assessment of the energy use impact of occupancy-based controls of energy consuming systems and technologies.

42 ENGINEERING↗