Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale↗

Performance Evaluation of the International Space Station Flow Boiling and Condensation Experiment (FBCE) Test Facility

A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.

microgravity↗

Thermal Model of a Zero Boil Off System for the Nuclear Thermal Propulsion System

NASA is currently developing an updated concept for a nuclear thermal propulsion (NTP) system. To enable this concept, efficient thermal insulation and cryocooler heat exchanger systems are required to eliminate boil-off of propellant. This paper presents the results of a thermal model used to assess the feasibility of using active cooling with a tube-on-tank heat exchanger configuration for the inline tank of the NTP system. Results show that: cryocooler working fluid temperature and mass flow rate can be adjusted to achieve zero boil off (ZBO) with broad area cooling, over-sizing the cryocooler lift directly translates into a reduction in tank pressure, and broad area cooling may still maintain ZBO despite the reduced heat transfer between tank wall and propellant that is expected in reduced gravity.

zero boil off↗

Flow Boiling in Microgap Coolers - Suborbital Flight Results

Flow Boiling in Microgap Coolers (FBMC) is a thermal management technique that provides embedded, on-site heat removal for power dense electronic components and systems. The dielectric coolant undergoes liquid-to-vapor phase change as it passes through channels integrated within or between devices. By facilitating direct contact between the coolant and heat-generating devices and relying on phase change, the system provides tight temperature control, hot spot mitigation, very high heat transfer coefficients, and low pumping power. Ground tests demonstrated removal of high heat fluxes (up to 500 kW/m2), very high coefficients of performance (up to 40 W of heat transferred per W of pumping power), and consistent performance across five evaporator orientations under the appropriate conditions. As a follow-on study and to better assess the role of gravity on such two-phase systems, the FBMC payload was developed and flown twice aboard the Blue Origin New Shepard space vehicle in January and May 2019. Each flight exposed the payload to weightlessness (150 seconds below 0.01 g) and shorter periods of high-g during ascent (up to 3 g) and descent (up to 5 g). The flow boiling performance was consistent independent of the acceleration levels, which provides confidence that such systems will provide consistent performance when tested on the ground, orbiting or traveling through weightlessness, and operating on the surface of the Moon, Mars, and other planetary bodies. Details of the flight results, payload development, flight environment, and planned future testing will be presented.

Flow boiling↗

Topical: Boiling, Condensation and Two-Phase Flows in Microgravity

The white paper addresses both fundamental and technological questions in the science of phase-change fluid flows aimed at understanding thermal transport in flow boiling and condensation and the use of these processes in space and terrestrial thermal systems. While flow boiling and condensation are widely employed in Earth-based thermal equipment to reduce the cost, size, and power required to transfer heat, a lack of data and predictive models on the impact of gravity on these phenomena hinders the use of two-phase heat transport in a low-gravity environment. The white paper presents research tasks in long-duration microgravity recommended to expand our knowledge on phase-changing flows. Due to elimination of the masking gravity effects, the proposed research will provide a unique opportunity to bring new insights into the role of capillary and hydrodynamic forces in phase-changing flows. The potential impact of the proposed research ranges from the space power, thermal and cryogenic systems to various terrestrial applications in the petrochemical, pharmaceutical, biochemical, nuclear, and metallurgical industries.

Phase-change fluid flow↗

Experimental Results and Interfacial Lift-off Model Predictions of Critical Heat Flux for Flow Boiling with Subcooled Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

This study investigates critical heat flux (CHF) for subcooled flow boiling of n-Perfluorohexane based on results of pre-launch Earth-gravity Mission Sequence Tests (MSTs) of the Flow Boiling and Condensation Experiment (FBCE), which was launched to the International Space Station (ISS) in August 2021. CHF measurements were made in a rectangular channel having a 2.5 mm by 5 mm cross-section and a 114.6-mm long heated segment. Both single-sided and double-sided heating were tested in vertical upflow in Earth gravity for a variety of inlet conditions. The inlet subcooling was varied in the range of 0.4 – 32.0°C and encompassed both near-saturated and highly subcooled conditions. Experimental trends and high-speed video records were investigated to better understand the mechanism of CHF. Overall trends show CHF increases as flow rate and/or inlet subcooling are increased. Flow features from the events around CHF justify the applicability of the Interfacial Lift-off Model and the determination of limiting criteria for its application. The present experimental data are combined with prior databases for various flow orientations with respect to Earth gravity and microgravity data collected on parabolic flights. Predictions are made using the Interfacial Lift-off Model for this consolidated subcooled-inlet FBCE-CHF database. A heat utility ratio was included in the model to capture the effects of subcooling and corresponding thermodynamic non-equilibrium. An overall mean absolute error of 19.04% indicates good predictive capability of the model for both heating configurations, different gravity environments, and a wide range of inlet subcooling.

flow boiling↗

NASA Team Develops a Test Article to Demonstrate “Zero Boil-Off” Storage of Liquid Hydrogen via Cryocoolers and a Two-Stage Cooling Approach

Funded by NASA’s Technology Demonstration Mission Program and managed by the Cryogenic Fluid Management Portfolio Project, a NASA team is developing a test article to demonstrate the “zero boil-off” storage of liquid hydrogen using active cooling (cryocoolers) and a two-stage cooling approach. The current state of the art for storage of liquid hydrogen on-orbit is on the order of hours while future missions may require storage for months or even years. To enable such extended storage durations, “near zero” propellant loss, or “zero boil-off”, must be achieved. This may be accomplished with the implementation of “near zero” leakage components, a high performing suite of passive technologies to minimize the environmental heat loads, and active cooling via cryocoolers to intercept and remove heat from the propellant tanks and associated structure. Of course, with any cryogenic vehicle and mission, a mass and power trade should be conducted to determine if it is indeed feasible to carry the additional dry mass associated with active cooling, or if one could simply carry additional propellants to accommodate propellant loss which is typically not an option for a long duration mission.

Hydrogen Storage↗

A CFD Framework for Film Boiling and Quenching in Cryogenic Chilldown

Tests of cryogenic chilldown in a vertical stainless steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters the room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFD-based modeling framework employing the mixture multiphase model has been developed to simulate this chilldown process and applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a two test conditions are simulated to test the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and is considered in the CFD model. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. Simulated vapor volume fraction distributions are also presented, although the current lack of experimental volume fraction data does not permit a comparison.

Computational Fluid Dynamics↗

A CFD Framework for Film Boiling and Quenching in Cryogenic Chilldown

Tests of cryogenic chilldown in a vertical stainless-steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters a room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFDbased modeling framework employing the mixture multiphase model was developed to simulate this chilldown process and was applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a range of test conditions are simulated to assess the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and considered in the CFD framework. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. In addition, simulated distributions of the vapor volume fraction are presented, but the current lack of experimental volume fraction data prevents comparisons.

Computational Fluid Dynamics↗

A CFD Framework for Film Boiling and Quenching in Cryogenic Chilldown

Tests of cryogenic chilldown in a vertical stainless-steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters a room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFDbased modeling framework employing the mixture multiphase model was developed to simulate this chilldown process and was applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a range of test conditions are simulated to assess the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and considered in the CFD framework. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. In addition, simulated distributions of the vapor volume fraction are presented, but the current lack of experimental volume fraction data prevents comparisons.

Computational Fluid Dynamics↗

Decoupling Surface Topography from Gravitational Acceleration in Cryogenic Pool Boiling

Boiling heat transfer is governed by a complex interplay between surface conditions and gravitational acceleration. To isolate the sole effects of gravity, we investigated the pool boiling characteristics of liquid nitrogen on atomically smooth silicon dioxide (SiO 2 ) surfaces under terrestrial (1-g) and reduced gravity (0±0.02 g) conditions achieved via parabolic flight. Our results quantify a drastic reduction in the critical heat flux (CHF) in reduced gravity, decreasing from 16.15 W/cm 2 at 1-g to 5−6 W/cm 2 at μ-g due to the suppression of buoyancy. Conversely, we observed a distinct increase in the heat transfer coefficient (HTC) in the reduced gravity condition prior to CHF. By utilizing a surface with a maximum peak-to-valley height of ≈36.7 nm and low contact angle hysteresis (<10°), we confirm this HTC enhancement is an intrinsic response to the gravitational environment, decoupled from surface-defect-induced nucleation. These findings demonstrate that the influence of surface topography is significantly more prominent in reduced gravity than in terrestrial conditions, providing a critical baseline for rationalizing the design of cryogenic thermal management systems in space and quantum applications.

Liquid nitrogen↗

Heating surface material’s effect on subcooled flow boiling heat transfer of R134a

In this study, subcooled flow boiling of R134a on copper (Cu) and stainless steel (SS) heating surfaces was experimentally investigated from both macroscopic and microscopic points of view. By utilizing a high-speed digital camera, bubble growth rate, bubble departure size, and nucleation site density, were able to be observed and analyzed from the microscopic point of view. Macroscopic characteristics of the subcooled flow boiling, such as heat transfer coefficient, were able to be measured as well. Experimental results showed that there are no obvious difference between the copper and the stainless surface with respect to bubble dynamics, such as contact angle, growth rate and departure size. On the contrary, the results clearly showed a trend that the copper surface had a better performance than the stainless steel surface in terms of heat transfer coefficient. It was also observed that wall heat fluxes on both surfaces were found highly correlated with nucleation site density, as bubble hydrodynamics are similar on these two surfaces. The difference between these two surfaces was concluded as results of different surface thermal conductivities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Time-resolved measurement of subchannel void distribution for boiling two-phase flow in 5 x 5 rod bundle at high-pressure and high-temperature

A subchannel void sensor (SCVS) was improved to acquire time-resolve boiling two-phase flow in a 5-by-5 heated rod bundle at high-pressure and high-temperature. The SCVS consists of 6-by-6 wire electrodes and 5-by-5 rod electrodes. The SCVS can acquire a time series data of local void fraction at 32 points of central subchannel region in addition to 100 points of rod surface regions between rods. The devised sensors are installed in the heated rod bundle at eight height levels to acquire two-phase flow dynamics and its development. The axial and radial power profile of the heated rod bundle are uniform, and eight pairs of sheath thermocouples are embedded on the heated rod to monitor its surface temperature distribution. The paper addresses the axial and cross-sectional distributions of void fraction at various pressure and rod bundle power conditions, which simulates an accidental condition in reactor core and in a spent fuel pool of a boiling water reactor (BWR). The experimental data are suitable to validate the computational multi-fluid dynamics (CMFD) and subchannel codes. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A new model for active nucleation site density in boiling systems

A new model for active nucleation site density in boiling systems has been developed. The model is based on parametric analysis of existing experimental data and is a function of wall superheat, pressure, and contact angle. The model is applicable for a wide pressure range - from 0.101 MPa to 19.8 MPa. Preliminary studies of temperature dependency of the contact angle have also been performed. The new model is intended to improve the predictions of the interfacial area concentration in two-fluid models and the wall temperature in subcooled boiling simulations. Validation activities have shown that the active nucleation site density predicted by the new model is in a good agreement with various published experimental data, and have demonstrated the achieved improvements as compared to existing models. (authors)

42 ENGINEERING↗

The Effect of Support Rod on Film Boiling Heat Transfer for Hot Metal Sphere in Subcooled Water

In fuel-coolant interaction (FCI), the heat transfer of corium has been conventionally evaluated by the correlations with a sphere developed in boiling region for subcooled film. However, these correlations do not give significant consideration on the support rod for the sphere from their developments, although Nishio et al. pointed out that the heat transfer and the vapor film collapsing mode would depend on H/D ratio. In this study, we performed experimental tests with the SS316 sphere (10 mm) and found the noticeable increase on the heat transfer in subcooled film boiling region with the deeper immersion depth and larger diameter of support rod. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Heterogeneous Nucleating Agent for High‐Boiling‐Point Nonhalogenated Solvent‐Processed Organic Solar Cells and Modules

Abstract High‐boiling‐point nonhalogenated solvents are superior solvents to produce large‐area organic solar cells (OSCs) in industry because of their wide processing window and low toxicity; while, these solvents with slow evaporation kinetics will lead excessive aggregation of state‐of‐the‐art small molecule acceptors (e.g. L8‐BO), delivering serious efficiency losses. Here, a heterogeneous nucleating agent strategy is developed by grafting oligo (ethylene glycol) side‐chains on L8‐BO (BTO‐BO). The formation energy of the obtained BTO‐BO; while, changing from liquid in a solvent to a crystalline phase, is lower than that of L8‐BO irrespective of the solvent type. When BTO‐BO is added as the third component into the active layer (e.g. PM6:L8‐BO), it easily assembles to form numerous seed crystals, which serve as nucleation sites to trigger heterogeneous nucleation and increase nucleation density of L8‐BO through strong hydrogen bonding interactions even in high‐boiling‐point nonhalogenated solvents. Therefore, it can effectively suppress excessive aggregation during growth, achieving ideal phase‐separation active layer with small domain sizes and high crystallinity. The resultant toluene‐processed OSCs exhibit a record power conversion efficiency (PCE) of 19.42% (certificated 19.12%) with excellent operational stability. The strategy also has superior advantages in large‐scale devices, showing a 15.03‐cm 2 module with a record PCE of 16.35% (certificated 15.97%).

Chemistry↗