Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Ion beam development for the needs of the JYFL nuclear physics programme

The increased requirements towards the use of higher ion beam intensities motivated us to initiate the project to improve the overall transmission of the K130 cyclotron facility. With the facility the transport efficiency decreases rapidly as a function of total beam intensity extracted from the JYFL ECR ion sources. According to statistics, the total transmission efficiency is of the order of 10% for low beam intensities (I{sub total}{<=}0.7 mA) and only about 2% for high beam intensities (I{sub total}>1.5 mA). Requirements towards the use of new metal ion beams for the nuclear physics experiments have also increased. The miniature oven used for the production of metal ion beams at the JYFL is not able to reach the temperature needed for the requested metal ion beams. In order to fulfill these requirements intensive development work has been performed. An inductively and a resistively heated oven has successfully been developed and both are capable of reaching temperatures of about 2000 deg. C. In addition, sputtering technique has been tested. GEANT4 simulations have been started in order to better understand the processes involved with the bremsstrahlung, which gives an extra heat load to cryostat in the case of superconducting ECR ion source. Parallel with this work, a new advanced ECR heating simulation program has been developed. In this article we present the latest results of the above-mentioned projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Recombination in a Dense Hydrogen Plasma

A high pressure hydrogen gas filled RF cavity was subjected to an intense proton beam to study the evolution of the beam induced plasma inside the cavity. Varying beam intensities, gas pressures and electric fields were tested. Beam induced ionized electrons load the cavity, thereby decreasing the accelerating gradient. The extent and duration of this degradation has been measured. A model of the recombination between ionized electrons and ions is presented, with the intent of producing a baseline for the physics inside such a cavity used in a muon accelerator. Analysis of the data taken during the summer of 2011 shows that self recombination takes place in pure hydrogen gas. The decay of the number of electrons in the cavity once the beam is turned off indicates self recombination rather than attachment to electronegative dopants or impurities. The cross section of electron recombination grows for larger clusters of hydrogen and so at the equilibrium of electron production and recombination in the cavity, processes involving H{sub 5}{sup +} or larger clusters must be taking place. The measured recombination rates during this time match or exceed the analytic predicted values. The accelerating gradient in the cavity recovers fully in time for the next beam pulse of a muon collider. Exactly what the recombination rate is and how much the gradient degrades during the 60 ns muon collider beam pulse will be extrapolated from data taken during the spring of 2012.

43 PARTICLE ACCELERATORS↗

The photon analysis, delivery, and reduction system at the FERMI-Elettra free electron laser user facility

The FERMI-Elettra free electron laser (FEL) user facility is currently under construction at the Sincrotrone Trieste laboratory in Trieste (Italy). It will cover the wavelength range from 100 to about 5 nm in the fundamental and 3 or 1 nm using the third harmonic. We report the layout of the photon beam diagnostics section, the radiation transport system to the experimental area, and the photon beam distribution system. Due to the peculiar characteristics of the emitted FEL radiation (high peak power, short pulse length, and statistical variation of the emitted intensity and distribution), the realization of the diagnostics system is particularly challenging. The end users are interested in parameters such as the radiation pulse intensity and spectral distribution, as well as in the possibility to attenuate the intensity. In order to accomplish these tasks, a photon analysis, delivery, and reduction system is now under development and construction and is presented here. This system will work on-line producing pulse-resolved information and will let users keep track of the photon beam parameters during the experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fracture Behavior and Properties of Functionally Graded Fiber-Reinforced Concrete

In concrete pavements, a single concrete mixture design is selected to resist mechanical loading without attempting to adversely affect the concrete pavement shrinkage, ride quality, or noise attenuation. An alternative approach is to design distinct layers within the concrete pavement surface which have specific functions thus achieving higher performance at a lower cost. The objective of this research was to address the structural benefits of functionally graded concrete materials (FGCM) for rigid pavements by testing and modeling the fracture behavior of different combinations of layered plain and synthetic fiber-reinforced concrete materials. Fracture parameters and the post-peak softening behavior were obtained for each FGCM beam configuration by the three point bending beam test. The peak loads and initial fracture energy between the plain, fiber-reinforced, and FGCM signified similar crack initiation. The total fracture energy indicated improvements in fracture behavior of FGCM relative to full-depth plain concrete. The fracture behavior of FGCM depended on the position of the fiber-reinforced layer relative to the starter notch. The fracture parameters of both fiber-reinforced and plain concrete were embedded into a finite element-based cohesive zone model. The model successfully captured the experimental behavior of the FGCMs and predicted the fracture behavior of proposed FGCM configurations and structures. This integrated approach (testing and modeling) demonstrates the viability of FGCM for designing layered concrete pavements system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Terahertz radiation source based on self-wake beam bunching

A table top device for producing high power T-ray beams is described. A rectangular electron beam that can be produced out of a photoinjector via stacking of the laser pulse, and running off-crest of the photoinjector rf is sent through a dielectric loaded waveguide. Due to the beam's self-wake its energy becomes modulated. In the chicane beamline following the dielectric energy-bunching section this energy modulation is converted to a density modulation-a bunch train. The density modulated beam can be sent through a power extraction section, like a dielectric loaded accelerating structure, or simply can intercept a foil target, producing THz radiation of various bandwidths and power levels.

43 PARTICLE ACCELERATORS↗

Analysis of the beam halo in negative ion sources by using 3D3V PIC code

The physical mechanism of the formation of the negative ion beam halo and the heat loads of the multi-stage acceleration grids are investigated with the 3D PIC (particle in cell) simulation. The following physical mechanism of the beam halo formation is verified: The beam core and the halo consist of the negative ions extracted from the center and the periphery of the meniscus, respectively. This difference of negative ion extraction location results in a geometrical aberration. Furthermore, it is shown that the heat loads on the first acceleration grid and the second acceleration grid are quantitatively improved compared with those for the 2D PIC simulation result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Brookhaven National Laboratory electron beam ion source for RHIC

As part of a new heavy ion preinjector that will supply beams for the Relativistic Heavy Ion Collider and the National Aeronautics and Space Administration Space Radiation Laboratory, construction of a new electron beam ion source (EBIS) is now being completed. This source, based on the successful prototype Brookhaven National Laboratory Test EBIS, is designed to produce milliampere level currents of all ion species, with q/m = (1/6)-(1/2). Among the major components of this source are a 5 T, 2-m-long, 204 mm diameter warm bore superconducting solenoid, an electron gun designed to operate at a nominal current of 10 A, and an electron collector designed to dissipate {approx} 300 kW of peak power. Careful attention has been paid to the design of the vacuum system, since a pressure of 10{sup -10} Torr is required in the trap region. The source includes several differential pumping stages, the trap can be baked to 400 C, and there are non-evaporable getter strips in the trap region. Power supplies include a 15 A, 15 kV electron collector power supply, and fast switchable power supplies for most of the 16 electrodes used for varying the trap potential distribution for ion injection, confinement, and extraction. The EBIS source and all EBIS power supplies sit on an isolated platform, which is pulsed up to a maximum of 100 kV during ion extraction. The EBIS is now fully assembled, and operation will be beginning following final vacuum and power supply tests. Details of the EBIS components are presented.

43 PARTICLE ACCELERATORS↗

Proton beam power limits for stationary water-cooled tungsten target with different cladding materials

The proton beam power limit for a solid-tungsten spallation target is largely determined by beam induced thermomechanical structural loads and decay heat power deposition, while its lifetime is limited by radiation damage and fatigue life of the target materials. In this paper, we studied the power limits of a stationary water-cooled solid tungsten target concept. Tantalum clad tungsten was considered as a reference case. Being a low activation material, zircaloy 2 cladding option was studied and its decay heat driven power limit was compared with the reference case. Zirconium alloys have proven operations records in spallation target and nuclear fission environments, supported by materials data obtained from post irradiation examinations. Recent study also demonstrated feasibility of diffusion bonding zirconium to tungsten using vanadium foil inter layer. Particle transport simulations code FLUKA was used to calculate energy deposition and decay heat power deposition in the target, based on the beam parameters technically feasible at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory. The energy deposition data were used for flow, thermal, and structural analyses to determine the beam intensity limit on the target concept studied. The decay heat deposition data were used to calculate the transient temperature evolution in the tungsten volumes in a loss of coolant accident (LOCA) scenario to determine its beam power limit. For a 1.3 GeV proton beam, the power limit on a stationary target was 400 kW for a tantalum clad target model and 800 kW for a zircaloy 2 clad target model.

Lee, Yong Joong↗

Transmission diamond imaging detector

Many modern synchrotron techniques are trending toward use of high flux beams and/or beams which require enhanced stability and precise understanding of beam position and intensity from the front end of the beamline all the way to the sample. For high flux beams, major challenges include heat load management in optics (including the vacuum windows) and a mechanism of real-time volumetric measurement of beam properties such as flux, position, and morphology. For beam stability in these environments, feedback from such measurements directly to control systems for optical elements or to sample positioning stages would be invaluable. To address these challenges, we are developing diamond-based instrumented vacuum windows with integrated volumetric x-ray intensity, beam profile and beam-position monitoring capabilities. A 50 µm thick single crystal diamond has been lithographically patterned to produce 60 µm pixels, creating a >1kilopixel free-standing transmission imaging detector. This device, coupled with a custom, FPGA-based readout, has been used to image both white and monochromatic x-ray beams and capture the last x-ray photons at the National Synchrotron Light Source (NSLS). This technology will form the basis for the instrumented end-station window of the x-ray footprinting beamline (XFP) at NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strength and elasticity of niobium under high pressure

High purity polycrystalline niobium contained in boron-epoxy gasket was compressed in a diamond anvil cell (DAC). The pressure was increased in steps of {approx}3 GPa and the diffraction patterns recorded at each pressure with the incident x-ray beam perpendicular to the load axis of the DAC (radial diffraction). The maximum pressure reached was 37.6 GPa. The compressive strength (differential stress) derived from the radial diffraction data is 0.44(1) GPa at 2.1 GPa and shows a shallow maximum at {approx}5 GPa, and then decreases to 0.35(5) at 12 GPa. At higher pressures, strength increases nearly linearly and the extrapolated value at 40 GPa is 0.94(6) GPa. At any pressure, the single-crystal elastic moduli derived from the diffraction data can be made to match well those obtained from the extrapolation of the elasticity data at ambient pressure by adjusting the weight parameter {alpha} that appears in the lattice strain theory. The parameter {alpha} is found to decrease from 2.00(8) at 2.1 GPa to 1.35(4) at 37.6 GPa.

36 MATERIALS SCIENCE↗

Emittance Growth from Electron Beam Modulatio

In Iinac ring colliders like MeRHIC and eRHIC a modulation of the electron bunch can load to a modulation of the beam beam tune shift and steering errors. These modulations can lead to emittance growth. This note presents simple formulas to estimate these effects which genera size some previous results.

43 PARTICLE ACCELERATORS↗

Acoustic Emission-Based Methodology to Evaluate Delamination Crack Growth Under Quasi-static and Fatigue Loading Conditions

The aim of this study was to investigate the applicability of acoustic emission (AE) technique to evaluate delamination crack in glass/epoxy composite laminates under quasi-static and fatigue loading. To this aim, double cantilever beam specimens were subjected to mode I quasi-static and fatigue loading conditions and the generated AE signals were recorded during the tests. By analyzing the mechanical and AE results, an analytical correlation between the AE energy with the released strain energy and the crack growth was established. It was found that there is a 3rd degree polynomial correlation between the crack growth and the cumulative AE energy. Using this correlation the delamination crack growth was predicted under both the static and fatigue loading conditions. The predicted crack growth values was were in a good agreement with the visually recorded data during the tests. The results indicated that the proposed AE-based method has good applicability to evaluate the delamination crack growth under quasi-static and fatigue loading conditions, especially when the crack is embedded within the structure and could not be seen visually.

42 ENGINEERING↗

Analytical workflow dependence of experimental observables for uranium chemistries

In this work, we investigated how the sequencing of laboratory analytical methods used for chemical and morphological characterization influences analytical findings for particulate materials relevant to the nuclear fuel cycle, including UO2, U3O8, studtite (UO2O2·4H2O), and β-UO3, in the context of nuclear forensic analysis. Particles of each chemistry obtained from consistent production batches were exposed to Raman spectroscopy and scanning electron microscopy in varying orders to elucidate how the order in which the techniques are applied influences morphological and chemical observations as a function of particle size. The results indicate that particles from all four chemistries exposed to high-resolution electron imaging before Raman spectral analysis demonstrate optical vibrational spectral changes that reduce accurate interpretation of the underlying chemistry via Raman spectral analysis. We hypothesize that these changes are due to the thermal load of the electron beam imparted to the sample being unable to be dissipated by materials with poor thermal conduction properties. Results from this study will aid in determining best practices for forensic analysis procedures to reduce uncertainty in chemical determination of unknown particulate samples.

Manns, Rebecca [University of Nevada, Las Vegas]↗

Numerical studies of powerful terahertz pulse generation from a super-radiant surface wave oscillator

The results of theoretical and numerical studies of coherent stimulated terahertz radiation from intense, subnanosecond electron beam are presented. The mechanism of terahertz pulse generation is associated with self-bunching of the beam and slippage of the wave over the whole electron flow. This so called Cherenkov super-radiance (SR) is used to propose a compact terahertz generator with high peak power. A large cross-section (overmoded), slow wave structure is designed to support the high power handling capability, and the mode competition is avoided by operating the device in the surface wave status. With 2.5 D particle-in-cell simulation, the 'hot' characteristics of the proposed super-radiant terahertz generator are investigated, and the numerical results show that the SR peak power could be further increased by optimizing the amplitude profile of electron pulse. Under the condition of 0.5 ns pulsewidth, 500 kV voltage, and 1.5 kA current, the 110 ps, 680 MW, and 0.14 THz SR pulse is achieved with a power efficiency of 90.67% in TM{sub 01} mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma formation in a double-gap vircator

Time-resolved light emission imaging was used to observe the plasma formation within the cavity of the double-gap vircator powered by a sub-microsecond generator ({approx}500 kV, {approx}10 kA, {approx}500 ns). The vircator generated well reproducible S-band microwave pulses of {approx}200 MW peak power and up to 200 ns full duration. The plasma light emission was observed {approx}30 ns prior to the ending of the generated microwave pulses at the surface of the aluminum foil separating the vircator cavity gaps, in the gap where the virtual cathode is formed. Estimations showed that the energy deposition into the foil by the high-current electron beam is sufficient for the surface plasma formation. The plasma ions accelerated toward the virtual cathode neutralize its electron space charge. The latter was confirmed by the increase in the electron current transmitted through the vircator cavity. In addition, the time of the plasma appearance was determined by comparing the measured transmitted current with that following from the one-dimensional model of a stationary un-neutralized two-stream electron flow. This time agrees with the maximum of the microwave power observed in the experiments, thus showing that the plasma ions cause the termination of the microwave generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computational evaluation of the flexoelectric effect in dielectric solids

Flexoelectricity is a size-dependent electromechanical mechanism coupling polarization and strain gradient. It exists in a wide variety of materials, and is most noticeable for nanoscale objects, where strain gradients are higher. Simulations are important to understand flexoelectricity because experiments at very small scales are difficult, and analytical solutions are scarce. Here, we computationally evaluate the role of flexoelectricity in the electromechanical response of linear dielectric solids in two-dimensions. We deal with the higher-order coupled partial differential equations using smooth meshfree basis functions in a Galerkin method, which allows us to consider general geometries and boundary conditions. We focus on the most common setups to quantify the flexoelectric response, namely, bending of cantilever beams and compression of truncated pyramids, which are generally interpreted through approximate solutions. While these approximations capture the size-dependent flexoelectric electromechanical coupling, we show that they only provide order-of-magnitude estimates as compared with a solution fully accounting for the multidimensional nature of the problem. We discuss the flexoelectric mechanism behind the enhanced size-dependent elasticity in beam configurations. We show that this mechanism is also responsible for the actuation of beams under purely electrical loading, supporting the idea that a mechanical flexoelectric sensor also behaves as an actuator. The predicted actuation-induced curvature is in a good agreement with experimental results. The truncated pyramid configuration highlights the critical role of geometry and boundary conditions on the effective electromechanical response. Our results suggest that computer simulations can help understanding and quantifying the physical properties of flexoelectric devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Horn-coupled, commercially-fabricated aluminum lumped-element kinetic inductance detectors for millimeter wavelengths

We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated 20-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, the horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the measured noise-equivalent temperatures for a 4 K optical load are in the range 26±6 μK√(s)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗