Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attribute measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Separating the Influence of Environment from Stress Relaxation Effects on Dwell Fatigue Crack Growth in a Nickel-Base Disk Alloy

Both environmental embrittlement and crack tip visco-plastic stress relaxation play a significant role in determining the dwell fatigue crack growth (DFCG) resistance of nickel-based disk superalloys. In the current study performed on the Low Solvus High Refractory (LSHR) disk alloy, the influence of these two mechanisms were separated so that the effects of each could be quantified and modeled. Seven different microstructural variations of LSHR were produced by controlling the cooling rate and the subsequent aging and thermal exposure heat treatments. Through cyclic fatigue crack growth testing performed both in air and vacuum, it was established that four out of the seven LSHR heat treatments evaluated, possessed similar intrinsic environmental resistance to cyclic crack growth. For these four heat treatments, it was further shown that the large differences in dwell crack growth behavior which still persisted, were related to their measured stress relaxation behavior. The apparent differences in their dwell crack growth resistance were attributed to the inability of the standard linear elastic fracture mechanics (LEFM) stress intensity parameter to account for visco-plastic behavior. Crack tip stress relaxation controls the magnitude of the remaining local tensile stresses which are directly related to the measured dwell crack growth rates. It was hypothesized that the environmentally weakened grain boundary crack tip regions fail during the dwells when their strength is exceeded by the remaining local crack tip tensile stresses. It was shown that the classical creep crack growth mechanisms such as grain boundary sliding did not contribute to crack growth, but the local visco-plastic behavior still plays a very significant role by determining the crack tip tensile stress field which controls the dwell crack growth behavior. To account for the influence of the visco-plastic behavior on the crack tip stress field, an empirical modification to the LEFM stress intensity parameter, Kmax, was developed by incorporating into the formulation the remaining stress level concept as measured by simple stress relaxation tests. The newly proposed parameter, Ksrf, did an excellent job in correlating the dwell crack growth rates for the four heat treatments which were shown to have similar intrinsic environmental cyclic fatigue crack growth resistance.

Dwell crack growth↗

Separating the Influence of Environment from Stress Relaxation Effects on Dwell Fatigue Crack Growth

Seven different microstructural variations of LSHR were produced by controlling the cooling rate and the subsequent aging and thermal exposure heat treatments. Through cyclic fatigue crack growth testing performed both in air and vacuum, it was established that four out of the seven LSHR heat treatments evaluated, possessed similar intrinsic environmental resistance to cyclic crack growth. For these four heat treatments, it was further shown that the large differences in dwell crack growth behavior which still persisted, were related to their measured stress relaxation behavior. The apparent differences in their dwell crack growth resistance were attributed to the inability of the standard linear elastic fracture mechanics (LEFM) stress intensity parameter to account for visco-plastic behavior. Crack tip stress relaxation controls the magnitude of the remaining local tensile stresses which are directly related to the measured dwell crack growth rates. It was hypothesized that the environmentally weakened grain boundary crack tip regions fail during the dwells when their strength is exceeded by the remaining local crack tip tensile stresses. It was shown that the classical creep crack growth mechanisms such as grain boundary sliding did not contribute to crack growth, but the local visco-plastic behavior still plays a very significant role by determining the crack tip tensile stress field which controls the dwell crack growth behavior. To account for the influence of the visco-plastic behavior on the crack tip stress field, an empirical modification to the LEFM stress intensity parameter, Kmax, was developed by incorporating into the formulation the remaining stress level concept as measured by simple stress relaxation tests. The newly proposed parameter, Ksrf, did an excellent job in correlating the dwell crack growth rates for the four heat treatments which were shown to have similar intrinsic environmental cyclic fatigue crack growth resistance.

environmental damage↗

Airborne and Ground-Based Measurements of Aerosol Optical Depth of Freshly Emitted Anthropogenic Plumes in the Athabasca Oil Sands Region

In this work we report the airborne aerosol optical depth (AOD) from measurements within freshly emitted anthropogenic plumes arising from mining and processing operations in the Athabasca Oil Sands Region (AOSR) in the context of ground-based AERONET climatological daily averaged AODs at Fort McMurray (Alberta, Canada). During two flights on 9 and 18 June 2018, the NASA airborne 4STAR (Spectrometers for Sky-Scanning, Sun-Tracking Atmospheric Research) Sun photometer registered high fine-mode (FM, <1 µm) in-plume AODs of up to 0.4 and 0.9, respectively, in the vicinity of the plume source (<20 km). Particle composition shows that the plumes were associated with elevated concentrations of sulfates and ammonium. These high AODs significantly exceed climatological averages for June and were not captured by the nearby AERONET instrument (mean daily AODs of 0.10±0.01 and 0.07±0.02, maximum AOD of 0.12) due possibly to horizontal inhomogeneity of the plumes, plume dilution and winds which in certain cases were carrying the plume away from the ground-based instrument. The average 4STAR out-of-plume (background) AODs deviated only marginally from AERONET daily averaged values. While 4STAR AOD peaks were generally well correlated in time with peaks in the in situ-measured particle concentrations, we show that differences in particle size are the dominant factor in determining the 4STAR-derived AOD. During the two flights of 24 June and 5 July 2018 when plumes likely travelled distances of 60 km or more, the average 4STAR FM AOD increased by 0.01–0.02 over ∼50 km of downwind particle evolution, which was supported by the increases in layer AODs calculated from the in situ extinction measurements. Based on these observations as well as the increases in organic mass, we attribute the observed AOD increase, at least in part, to secondary organic aerosol formation. The in-plume and out-of-plume AODs for this second pair of flights, in contrast to clear differences in in situ optical and other measurements, were practically indistinguishable and compared favourably to AERONET within 0.01–0.02 AOD. This means that AERONET was generally successful in capturing the background AODs, but missed some of the spatially constrained high-AOD plumes with sources as close as 30–50 km, which is important to note since the AERONET measurements are generally thought to be representative of the regional AOD loading. The fact that industrial plumes can be associated with significantly higher AODs in the vicinity of the emission sources than previously reported from AERONET can potentially have an effect on estimating the AOSR radiative impact.

AERONET↗

Satellite Investigations of Fire, Smoke, and Carbon Monoxide during April 1994 MAPS Mission: Case Studies over Tropical Asia

During April 9-19, 1994, the Measurement of Air Pollution from Satellites (MAPS) measured free tropospheric carbon monoxide (CO) concentrations on a near-global basis. For these eleven days the global lkm advanced very high resolution radiometer (AVHRR) Pathfinder data are used to detect fires and smoke over the Indo-Burma region (85 degrees E - 110 degrees E; 10 degrees N -30 degrees N). The fire activities are categorized for four major ecosystems that include (1) cropland/natural vegetation mosaic (CNVM), (2) evergreen broadleaf forest (EBF), (3) mixed forest (MFD), and (4) grassland (GL). Using published emission rates between particulate matter and carbon monoxide concentrations from temperate areas, the fire counts along with other information are used to obtain estimates of CO concentrations from the AVERR data. More than 7000 fires are detected during the study period with 23%, 43%, 24%, and 10% fires in the CNVM, EBF, MFD, and GL ecosystems, respectively. The enhanced CO concentrations over the area of study are either over or downwind of the fires detected by the AVHRR. The preliminary AVHRR estimates of CO concentrations are smaller than the MAPS-measured values by a factor of 4 to 5 for fire counts areater than 200. The differences are attributed to the lack of transport mechanisms and other assumptions in the current model. However, these results show a good potential for usino the AVHRR measurements to detect fires and smoke and also to estimate CO concentrations.

Christopher, Sundar A.↗

Airborne Observations of the Spatial and Temporal Variability of Tropospheric Carbon Dioxide during the INTEX-B Campaign

The Intercontinental Chemical Transport Experiment-North America (INTEX-NA) is an international field campaign envisioned to investigate the transport and transformation of gases and aerosols on transcontinental/intercontinental scales and assess their impact on air quality and climate. Phase B (INTEX-B) of the mission was conducted during a 10- week period from March 1 to May 15, 2006 and focused initially on pollution outflow from the Mexico City Metropolitan Area, later addressing the transport of pollution from Asia to North America during springtime meteorological conditions. During the deployment, fast-response (1-s resolution) CO2 measurements were recorded aboard the NASA DC-8 providing valuable regional-scale information on carbon sources and sinks over sparsely sampled areas of North America and adjacent ocean basins. When coupled with the enormously sophisticated chemistry payload on the DC-8, these measurements collectively afford extremely powerful multi-tracer constraints for carbon source/sink attribution. Preliminary examination of the two data sets from the INTEX-B campaign, acquired one month apart, reveals not only the influence of the CO2 seasonal cycle, but also the preponderance of human population and industrial activity in the northern hemisphere. In this presentation, a synergy of the ensemble of airborne and surface observations, bottomup emission inventories, as well as transport history are invoked in a GIS framework to elucidate the source/sink processes reflected in the observations. The airborne CO2 data, along with simultaneous surface measurements (e.g. NOAA ESRL), are examined to establish the vertical distribution and variability of CO2 as a function of location. The role of localized sources, long-range transport, the biosphere, stratospheric exchange, and dynamical processes on the CO2 spatial variability observed throughout the tropospheric column will be discussed.

Vay, Stephanie A.↗

Initial Trade Study for In-line Silver Sensor for Spacecraft Potable Water Systems

Ionic silver is currently baselined as the biocide for microbial control in potable water systems for future space exploration missions. In-line monitoring of silver ion concentration is desired for system feedback control to introduce and maintain sufficient and safe levels of biocide in the water. To date, NASA testing of silver biocide system prototypes has made use of an Ion-Selective Electrode (ISE) for in-line silver concentration measurements. However, known issues with ISE technology have continued to motivate a search for alternate sensor systems. Although devices capable of detecting silver are available for terrestrial applications, these systems are generally not well-suited for the unique demands of spaceflight. Desired attributes include: low weight, volume, and power consumption; stable, autonomous, and in-line measurement capability; long calibration lifetime; and limited maintenance requirements. This paper provides the results from a preliminary trade study conducted on three candidate silver sensor technologies: ISEs, Anodic Stripping Voltammetry (ASV), and Fiber Optic Chemical Sensors (FOCS). The review of these technologies includes the rationale for their selection, an overview of the principles of their operation, and a detailed assessment of their strengths and weaknesses relative to the anticipated requirements of future spacecraft applications. The study concluded that none of the currently-available versions of these technologies is suitable for immediate application to spacecraft systems; further technology development should be considered. To that end, recommendations for forward development work have been proposed and provided herein.

Potable Water↗

Electrical properties of the middle atmosphere

Probe techniques have been utilized extensively to measure middle atmospheric electrical properties such as the polar components of conductivity, ion mobility and density. The most variable of these parameters is conductivity, which is dependent on both charge mobility and concentration. Overall conductivity variations, attributable to different geophysical conditions, can exceed several orders of magnitude at some altitudes. Also, measurements of conductivity over the 20 to 90 km region indicate a general exponential increase with altitude, exceeding seven orders of magnitude during certain conditions. Gerdien condensers, on occasion, have measured very low-mobility positive ions in addition to the more commonly observed molecular species. These smaller mobility values appear to indicate the presence of very large ions at some altitudes, possibly charged particulates, having mass sizes greater than those identifiable by presently flown mass spectrometers. The presence of these large ions is of importance to middle atmospheric electrodynamics as a potential causal mechanism for measured large electric fields.

Mitchell, John D.↗

SIMBAD quality-control

The astronomical database SIMBAD developed at the Centre de donnees astronomiques de Strasbourg presently contains 760,000 objects (stellar and non-stellar). It has the unique characteristic of being structured specifically for astronomical objects. All types of heterogeneous data (bibliographic references, measurements, and sets of identification) are connected with each object. The attributes that define quality of the database include the following. Reliability: cross-identification should not rely upon just exact values object coordinates. It also means that information attached to one simple object should be consistent. The existing data must be controlled in order to start with a reliable base and to cross-identify new data assuring the quality as data grows. Exhaustivity: delays between publication of new informations and their inclusion in the database should be as short as possible. The integrity of the database has to be maintained as data accumulates. Taking the amount of data into consideration and the rate of new data production, it is necessary to use automatic methods. One of the possibilities is to use multivariate data analysis. The factor-space is a n-dimensional relevancy space which is described by the n-axes representing a set of n subject matter headings; the words and phrases can be used to scale the axes and the documents are then a vector average of the terms within them. The application reported herein is based on the NASA-STI bibliographical database. The selected data concern astronomy, astrophysics, and space radiation (102,963 references from 1975 to 1991 included 8070 keywords). The F-space is built from this bibliographical data. By comparing the F-space position obtained from the NASA-STI keywords with the F-space position obtained from the SIMBAD references, the authors will be able to show whether it is possible to retrieve information with a restricted set of words only. If the comparison is valid, this will be a way to enter bibliographic information in the SIMBAD quality control process. Furthermore, it is possible to connect the physical measurements of stars from SIMBAD to literature concerning these stars from the NASA-STI abstracts. The physical properties of stars (e.g. UBV colors) are not randomly distributed. Stars are distributed among different clusters in a physical parameter space. The authors will show that there are some relations between this classification and the literature concerning these objects clusters in a factor space. They will investigate the nature of the relationship between the SIMBAD measurements and the bibliography. These would be new relationships that are not pre-established by an astronomer. In addition, the bibliography could be neutral information that can be used in combination with the measured parameters.

Lesteven, Soizick↗

Total hemispherical emittance measured at high temperatures by the calorimetric method

A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements (plus or minus 5 percent). The probable error of the CVE measurements was typically less than 1 percent.

Difilippo, Frank↗

A Magnetic Field Response Recorder: A New Tool for Measurement Acquisition

A magnetic field response recorder was developed to facilitate a measurement acquisition method that uses magnetic fields to power and to interrogate all sensors. Sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic field responses when electrically activated by oscillating magnetic fields. When electrically activated, the sensor's magnetic field response attributes (frequency, amplitude and bandwidth) correspond to the one or more physical states that each sensor measures. The response recorder makes it possible to simultaneously measure two unrelated physical properties using this class of sensors. The recorder is programmable allowing it to analyze one or more response attributes simultaneously. A single sensor design will be used to demonstrate that the acquisition method and the sensor example can be used to for all phases of a component's life from manufacturing to damage that can destroy it.

Woodard, Stanley E.↗

A Novel Instrument and Methodology for the In-Situ Measurement of the Stress in Thin Films

We introduce a novel methodology for the in-situ measurement of mechanical stress during thin film growth utilizing a highly sensitive non-contact variation of the classic spherometer. By exploiting the known spherical deformation of the substrate the value of the stress induced curvature is inferred by measurement of only one point on the substrate's surface-the sagittal. From the known curvature the stress can be calculated using the well-known Stoney equation. Based on this methodology, a stress sensor has been designed which is simple, highly sensitive, compact, and low cost. As a result of its compact nature, the sensor can be mounted in any orientation to accommodate a given deposition geometry without the need for extensive modification to an already existing deposition system. The technique employs the use of a double side polished substrate that offers good specular reflectivity and is isotropic in its mechanical properties, such as <111> oriented crystalline silicon or amorphous soda lime glass, for example. The measurement of the displacement of the uncoated side during deposition is performed with a high resolution (i.e. 5nm), commercially available, inexpensive, fiber optic sensor which can be used in both high vacuum and high temperature environments (i.e. 10(exp-7) Torr and 480oC, respectively). A key attribute of this instrument lies in its potential to achieve sensitivity that rivals other measurement techniques such as the micro cantilever method but, due to the comparatively larger substrate area, offers a more robust and practical alternative for subsequent measurement of additional characteristics of the film that can might be correlated to film stress. We present measurement results of nickel films deposited by magnetron sputtering which show good qualitative agreement to the know behavior of polycrystalline films previously reported by Hoffman.

Broadway, David M.↗

A procedure for space SDR prioritization

It was first necessary to arrive at a common set of attributes which described the relative importance of each Scientific Data Requirement (SDR) to the DOE CO2 Research Program. Many attributes were considered. Some were rejected because they related more to engineering considerations than to scientific ones. Finally four were selected: importance for early detection of CO2-induced effects; need for additional measurements; importance for model inputs; and importance for model outputs. Each SDR was scored on these attributes. These scores were categorical (for example, low, medium, and high) and formed the basis for assigning a relative value to each SDR. For this ranking a methodology based on dominance theory was used. The methodology and the selected SDRs are discussed.

Source record↗

Shuttle antenna radome technology test program. Volume 2: Development of S-band antenna interface design

The effects of the Thermal Protection Subsystem (TPS) contamination on the space shuttle orbiter S band quad antenna due to multiple mission buildup are discussed. A test fixture was designed, fabricated and exposed to ten cycles of simulated ground and flight environments. Radiation pattern and impedance tests were performed to measure the effects of the contaminates. The degradation in antenna performance was attributed to the silicone waterproofing in the TPS tiles rather than exposure to the contaminating sources used in the test program. Validation of the accuracy of an analytical thermal model is discussed. Thermal vacuum tests with a test fixture and a representative S band quad antenna were conducted to evaluate the predictions of the analytical thermal model for two orbital heating conditions and entry from each orbit. The results show that the accuracy of predicting the test fixture thermal responses is largely dependent on the ability to define the boundary and ambient conditions. When the test conditions were accurately included in the analytical model, the predictions were in excellent agreement with measurements.

Kuhlman, E. A.↗

A comparison of experimental and theoretical bidirectional reflectance functions

Bidirectional reflectance models developed by radiative transfer theory calculations are compared with empirical models from Nimbus 7 ERB measurements for two cloud altitudes (medium height cloud tops at 3 km and high cloud tops at 9 km). For solar zenith angles less than 60 deg, the models agree to within 10 percent. For larger zenith angles, however, the differences between the models increase rapidly. These differences are attributed to three-dimensional cloud effects and to smearing effects associated with averaging measurements over finite solar zenith angle ranges. It is thus demonstrated, that the theoretical models provide a good description of the radiance fields of clouds as seen by the satellite.

Stuhlmann, R.↗

Ultraviolet spectroscopy of Venus - Initial results from the Pioneer Venus orbiter

Ultraviolet spectroscopy of the Venus cloud tops reveals absorption features attributed to sulfur dioxide in the atmosphere above the cloud tops. Measurements of scattered sunlight at 2663 angstroms show evidence for horizontal and vertical inhomogeneities in cloud structure. Images of the planet at SO2 absorption wavelengths show albedo features similar to those seen at 3650 angstroms from Mariner 10. Airglow emissions are consistent with an exospheric temperature of about 275 K, and a night airglow emission has been detected, indicating the precipitation of energy into the dark thermosphere.

Stewart, A. I.↗

Comparison of analytical and flight test identified aerodynamic derivatives for a tandem-rotor transport helicopter

Flight tests for verifying an analytical aerodynamic derivative model of a CH-47 helicopter were conducted for low cruise speeds and transition to hover portions of curved, decelerating landing approach trajectories. All testing was performed on a closed loop basis with the stability augmentation system of the helicopter operating, and response data were obtained using both manual and computer generated input maneuvers. The results indicate some differences between the measured response time histories and those predicted by both analytical and flight test identified derivatives. With some exceptions the discrepancies are not severe, and the overall agreement between the measured and computed time histories is reasonably good. No adverse effects attributable to closed loop testing were noted, and the use of computer generated inputs proved to be superior to manual ones.

Hodge, W. F.↗

Optical and microphysical properties of a cold cirrus cloud - Evidence for regions of small ice particles

An airborne lidar and a scanning radiometer aboard an ER-2 aircraft were used to observe a cold cirrus cloud, and a Forward Scattering Spectrometer Probe (FSSP) was used to obtain simultaneous in situ microphysical observations at two altitudes within the cloud. Lidar depolarization ratio data show that the clouds were composed predominantly of ice crystals. At an altitude where the temperature was -62.7 C, the lidar and radiometer analysis gave a visible extinction to infrared absorption ratio (alpha) of 2.3, while the cloud microphysics data provided an alpha value of 3.77. The discrepancy is attributed to undersizing of particles by the FSSP. Direct and remote measurements showed better agreement for a lower layer where the temperature was -47.3 C.

Platt, C. M. R.↗