Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Improved modeling of the solid-to-plasma transition of polystyrene ablator for laser direct-drive inertial confinement fusion hydrocodes

We report that the target performance of laser direct-drive inertial confinement fusion (ICF) can be limited by the development of hydrodynamic instabilities resulting from the nonhomegeneous laser absorption at the target surface, i.e., the laser imprint on the ablator. To understand and describe the formation of these instabilities, the early ablator evolution during the laser irradiation should be considered. In this work, an improved modeling of the solid-to-plasma transition of a polystyrene ablator for laser direct-drive ICF is proposed. This model is devoted to be implemented in hydrocodes dedicated to ICF which generally assume an initial plasma state. The present approach consists of the two-temperature model coupled to the electron, ion and neutral dynamics including the chemical fragmentation of polystyrene. The solid-to-plasma transition is shown to significantly influence the temporal evolution of both free electron density and temperatures, which can lead to different shock formation and propagation compared with an initial plasma state. The influence of the solid-to-plasma transition on the shock dynamics is evidenced by considering the scaling law of the pressure with respect to the laser intensity. The ablator transition is shown to modify the scaling law exponent compared with an initial plasma state.

36 MATERIALS SCIENCE↗

WE-EF-BRA-12: Magnetic Resonance- Guided High-Intensity Focused Ultrasound for Localized Ablation of Head and Neck Tissue Structures: A Feasibility Study in An Animal Model

Purpose: High-intensity focused ultrasound (HIFU) ablation is feasible in the head and neck [1]. This study aims to expand upon these findings to assess the feasibility of treatment planning and monitoring via magnetic resonance imaging (MRI) guidance using a clinical MR-guided HIFU platform. Methods: Two 31 kg pigs were anaesthetized, shaved, and positioned prone on the HIFU table (Sonalleve, Philips Healthcare, Vantaa, Finland). The necks were acoustically coupled to the integrated transducer using gel pads and degassed water. MR imaging verified acoustic coupling and facilitated target selection in the thyroid and thymus. Targets were thermally ablated with 130–200 W of acoustic power over a period of 16 s at a frequency of 1.2 MHz while being monitored through real-time, multi-planar MR-thermometry. Contrast-enhanced MR imaging was used to assess treatment efficacy. Post-treatment, animals were euthanized and sonicated tissues were harvested for histology assessment. Results: MR-thermometry, post-contrast-imaging, and gross pathology demonstrated that the system was capable of causing localized thermal ablation in both the thyroid and the thymus without damaging the aerodigestive tract. In one animal, superficial bruising was observed in the ultrasound beam path. Otherwise, there were no adverse events. Analysis of the tissue histology found regions of damage consistent with acute thermal injury at the targeted locations. Conclusion: It is feasible to use a clinical MR-guided HIFU platform for extracorporeal ablation of porcine head and neck tissues. MR guidance and thermometry are sufficient to target and monitor treatment in the thyroid region, despite the presence of the inhomogeneous aerodigestive tract. Further study is necessary to assess efficacy and survival using a tumor model, and to examine what modifications should be made to the transducer positioning system and associated patient positioning aids to adapt it for clinical head and neck targets.Reference:[1] Esnault et al. (2011). Thyroid, 21(9), 965– 973. Funding support provided by Philips Healthcare. Ari Partanen is a paid employee of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Laser-Ablation Sampling for Accurate Analysis of Sulfur in Edible Salts

We evaluated the performance of laser ablation analysis techniques such as laser-induced breakdown spectroscopy (LIBS), laser ablation inductively coupled optical emission spectrometry (LA-ICP-OES), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), in comparison with that of ICP-OES using aqueous solutions for the quantification of sulfur (S) in edible salts from different geographical origins. We found that the laser ablation based sampling techniques were not influenced by loss of S, which was observed in ICP-OES with aqueous solutions for a certain salt upon their dissolution in aqueous solutions, originating from the formation of volatile species and precipitates upon their dilution in water. Although detection of S using direct laser sampling with LA-ICP-MS has well-known isobaric and polyatomic interferences, LIBS and LA-ICP-OES showed good accuracy in the detection of S for all salts. LIBS also provided the ability to identify the dominant chemical form in which S is present in salts. Correlation between S and oxygen, observed in LIBS spectra, provided chemical information about the presence of S 2- or SO$^{2-}_4$, which are associated with the origin and quality of edible salts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using double pulse laser ablation in air to enhance the strength of laser-driven shocks

In the process of multi-pulse laser ablation, inter-pulse delay time, Δ t , is known to be an important parameter for maximizing ablation efficiency as well as impulse imparted to the target. In this work, using photon Doppler velocimetry, we show that for single pairs of colinear pulses (1064 nm, 8 ns, ∼ 60 J cm -2 per pulse) in air, the peak free surface velocity of the back surface of an aluminum target (125 µm thick) is increased, by a factor of nearly 3, when Δ t = 10 microseconds, compared with both pulses arriving simultaneously (Δ t = 0). Fast imaging of the ablation process suggests this enhancement is due to rarefaction of the contiguous air in the passage of the leading shock produced by ablation, which then in turn allows a larger fraction of the energy of the second pulse to reach the target surface. This interpretation is strengthened by additional experiments in which the two pulses do not overlap on the target surface, but the shock strength is nevertheless enhanced. Given a fixed energy budget this work suggests a prescription for maximizing laser-driven shock strength by judicious choice of inter-pulse delay.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reduction of ablated surface expansion in pulsed-power-driven experiments using an aerosol dielectric coating (Final Technical Report)

The quality of warm dense matter samples created by magnetic compression can be largely affected by material ablation. When the ablated material carries currents, local instabilities can grow, which can lead to nonuniformities in the final magnetic pressure. Extending the previous work by Peterson et al. [Phys. Rev. Lett. 112, 135002 (2014)], Awe et al. [Phys. Rev. Lett. 116, 065001 (2016)], and Hutchison et al. [Phys. Rev. E 97, 053208 (2018)], the experiments reported here demonstrate that the expansion of the ablated material can be significantly reduced by using a simple aerosol spray technique. Coating the current-carrying surfaces with a 30–60-μm layer of polyurethane reduced the expansion of the ablated material by a factor of 2 and eliminated material ejections from sharp corners. This technique, tested at the Michigan Accelerator for Inductive Z-Pinch Experiments pulsed power facility at the University of Michigan with currents up to 400 kA, could allow the production of homogeneous warm dense matter samples on pulsed-power drivers. Because of the simplicity of this method, this work brings forth an important contribution to pulsed-power-driven experiments designed to study nuclear fusion, material properties, and radiation science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reflecting ablating heat shields for planetary entry.

Heat shielding for planetary entry probes of future Jovian and Venusian missions will encounter heating levels well beyond those previously experienced. These entries are typically dominated by radiative heating from the shock layer. This paper demonstrates the potential of reflecting this incident radiation diffusely from an ablating material. This technique contrasts with the absorption experienced by char-forming or graphitic ablators. Two dielectric materials, Teflon (polytetra-fluoroethylene) and boron nitride, are examined for their ablative performance, including reflection, in a combined convective- and radiative-heating environment. For Teflon, at the conditions obtained, superimposition of radiative heating upon a convective stream causes no additional increase in surface recession over the convective only results. For boron nitride, an excellent room-temperature reflector in the visible spectrum, a decrease in reflectivity from 90 to 55 percent is experienced when the surface undergoes sublimation at high temperatures. The process of reflection in each of these materials is described in terms of backscattering from crystals. The significance of a sizable reflection as a mode of energy accommodation is demonstrated for Venusian entries as a potential reduction in mass loss due to ablation.

Peterson, D. L.↗

Comparison of the aerodynamic characteristics of an ablating and nonablating blunted conical body

The influence of ablation on the aerodynamic characteristics of a blunted slender cone was investigated. Plastic models were launched in free flight at ablating conditions. The results were compared with results of similar tests using metal nonablating models. Ablation was found to decrease the dynamic stability and the drag, but had little effect on static stability and lift. The plastic models appeared to experience ablation-induced roll.

Kruse, R. L.↗

Ablative system

A carrier liquid containing ablative material bodies is connected to a plenum chamber wall with openings to a high temperature environment. The liquid and bodies pass through the openings of the wall to form a self replacing ablative surface. The wall is composed of honeycomb layers, spheres containing ablative whiskers or wads, and a hardening catalyst for the carrier liquid. The wall also has woven wicks of ablative material fibers that extend through the wall openings and into plenum chamber which contains the liquid.

Gray, V. H.↗

The thermal and mechanical properties of a low density elastomeric ablation material

Thermal and mechanical properties data were obtained for a low density elastomeric resin based ablation material with phenolic-glass honeycomb reinforcement. Data were obtained for the material in the charred and uncharred state. Ablation material specimens were charred in a laboratory furnace at temperatures in the range from 600 K to 1700 K to obtain char specimens representative of the ablation char layer formed during reentry. These specimens were then used to obtain effective thermal conductivity, heat capacity, porosity, and permeability data at the char formation temperature. This provided a boxing of the data which enables the prediction of the transient response of the material during ablation. Limited comparisons were made between the furnace charred specimens and specimens which had been exposed to simulated reentry conditions.

Engelke, W. T.↗

Ablation and radiation coupled viscous hypersonic shock layers.

Coupled ablator shock layer solutions for the stagnation point are presented for typical hyperbolic entry atmospheric flight conditions. These solutions were obtained by numerically solving the stagnation line shock layer equations and quasi-steady ablator equations. These equations included ablation and radiation coupling within the viscous shock layer, line and continuum radiation for both air and phenolic-nylon ablation species and local thermodynamic equilibrium throughout. The results presented provide a sound basis for understanding many of the processes characteristic of hypersonic shock layer heating.-

Engel, C. D.↗

An experimental investigation of the damping contribution of an elastomeric ablator on aluminum beams

Damping results are presented for an elastometric ablation material bonded to an aluminum alloy substrate. Tests were conducted on aluminum beams 0.159, 0.318, and 0.476 cm thick, and with and without an ablator. Ablation-material thickness varied from 0.159 to 0.953 cm. Comparative damping data were obtained by using variations of the free-free beam technique with strain gages and piezoelectric transducers. Of the two test arrangements employed, the technique using strain gages produced results that indicated less restraint of the beams. Ablation material, in thicknesses less than 1 cm, substantially increased the damping parameter of the aluminum beams.

Howell, W. E.↗

Artificial meteor ablation studies

Artificial meteor ablation was performed on natural minerals, composed predominately of magnetite and hematite, using an arc heated plasma stream of air. Analysis of the ablated debris indicated most was composed of two or more minerals. The more volatile elements were depleted and the relative abundance of Fe increased as a result of both volatile depletion and a reduction in its oxidation state. Hematite was converted to magnetite in the ablation zone, and quartz and apatite minerals were converted to an Fe-rich glass consisting of varying amounts of Si, P, Cl, and Ca, depending upon the accessory minerals available at the time of melting. Artificially created ablation products from iron oxides exhibited unique properties depending on the composition of the original material and the environmental conditions of formation. In addition to the accepted elemental criteria, these properties were morphologic characteristics, textural parameters, and the existence of metastable minerals.

Blanchard, M. B.↗

Effects of insulator ablation on the operation of a quasi-steady MPD arc

Multimegawatt operation of quasi-steady MPD arcjets can involve serious ablation of the insulator surfaces within the arc discharge chamber. Various degrees of insulator ablation manifest themselves by significantly perturbing the voltage-current characteristics and the exhaust velocity profiles. Voltage-current characteristics for two different insulator materials, Plexiglas and boron nitride, are interpreted in terms of an empirical Ohm's law. Use of the refractory insulator material eliminates the ablation-dominated nature of the terminal voltage, but the exhaust stream is still disturbed by insulator material. An Alfven critical velocity model can be applied to this influence of insulator ablation on exhaust velocity. Appropriate changes in the propellant injection geometry eliminate this influence and result in arcjet operation which is independent of insulator material. A particular combination of propellant injection geometries reduces the terminal voltage for a given current and mass flow while maintaining insulator-independent operation, thus implying an improvement in the overall efficiency of the device.

Boyle, M. J.↗

Ablative thermal protection for space tug multipass, aerobraking entry

Analytical studies had found the employment of an aerobraking trajectory for return of a reusable Space Tug from geosynchronous missions to be feasible and practical. To establish the minimum-weight ablative dome heat shield, trajectories involving 2 and 30 perigee passes were investigated both analytically and by plasma arc testing. Silicone-base ablators with densities of 15, 30, and 50 lb/cu ft were selected for evaluation. All models withstood the multipass exposures without deleterius surface recession or char erosion. Dome heat shield weights based on optimum ablative compositions indicated that ablators are a highly efficient thermal protection system for these missions.

Strauss, E. L.↗

Interaction of graphite and ablative materials with CO2-laser, carbon-arc, and xenon-arc radiation

The behavior of graphite and several charring ablators in a variety of high radiative heat flux environments was studied in various radiative environments produced by a CO2 laser and a carbon arc facility. Graphite was also tested in xenon arc radiation. Tests were conducted in air nitrogen, helium, and a mixture of CO2 and nitrogen, simulating the Venus atmosphere. The experimental results are compared with theoretical results obtained with a one dimensional charring ablator analysis and a two dimensional subliming ablator analysis. Photomicroscopy showed no significant differences in appearance or microstructure of the charring ablators or graphite after testing in the three different facilities, indicating that the materials respond fundamentally the same to the radiation of different frequencies. The performance of phenolic nylon and graphite was satisfactorily predicted with existing analyses and published material property data.

Brewer, W. D.↗

Thermal performance of a mechanically attached ablator tile for on-orbit repair of shuttle TPS

The reusable surface insulation (RSI) material used in the shuttle thermal protection system is susceptible to damage. If any RSI tiles are damaged or lost during ascent, they must be repaired or replaced prior to entry. One approach to replacing a damaged or missing RSI tile consists of mechanically attaching a tile of ablation material in the place of the RSI tile. The thermal performance of this type of repair tile was evaluated in a simulated entry heating environment. The test specimen consisted of the ablator repair tile mechanically fastened to the strain isolation pad and surrounded by RSI tiles. The evaluation of the thermal performance was based on temperature response, surface integrity, and predicted flight performance. When the ablator tile protruded 1/8 inch above the surrounding RSI tiles, the forward facing steps caused significant inflow of hot gas down the ablator RSI joints and this inflow caused greatly increased back surface temperatures.

Thompkins, S. S.↗

Shuttle subscale ablative nozzle tests

Recent subscale nozzle tests have identified new and promising carbon phenolic nozzle ablatives which utilize staple rayon, PAN, and pitch based carbon cloth. A 4-inch throat diameter submerged test nozzle designed for the 48-inch Jet Propulsion Laboratory char motor was used to evaluate five different designs incorporating 20 candidate ablatives. Test results indicate that several pitch and PAN-based carbon phenolic ablatives can provide erosion and char performance equivalent or superior to the present continuous rayon-based SRM ablative.

Powers, L. B.↗

Analysis of internal ablation for the thermal control of aerospace vehicles

A new method of thermal protection for transatmospheric vehicles is introduced. The method involves the combination of radiation, ablation and transpiration cooling. By placing an ablating material behind a fixed-shape, porous outer shield, the effectiveness of transpiration cooling is made possible while retaining the simplicity of a passive mechanism. A simplified one-dimensional approach is used to derive the governing equations. Reduction of these equations to non-dimensional form yields two parameters which characterize the thermal protection effectiveness of the shield and ablator combination for a given trajectory. The non-dimensional equations are solved numerically for a sample trajectory corresponding to glide re-entry. Four typical ablators are tested and compared with results obtained by using the thermal properties of water. For the present level of analysis, the numerical computations adequately support the analytical model.

Camberos, Jose A.↗