Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

LaAlO{sub 3} thickness window for electronically controlled magnetism at LaAlO{sub 3}/SrTiO{sub 3} heterointerfaces

Complex-oxide heterostructures exhibit rich physical behavior such as emergent conductivity, superconductivity, and magnetism that are intriguing for scientific reasons as well as for potential technological applications. It was recently discovered that in-plane magnetism at the LaAlO{sub 3}/SrTiO{sub 3} (LAO/STO) interface can be electronically controlled at room temperature. Here, we employ magnetic force microscopy to investigate electronically controlled ferromagnetism at the LAO/STO interface with LAO thickness t varied from 4 unit cell (u.c.) to 40 u.c. Magnetic signatures are observed only within a thickness window 8 u.c. ≤ t ≤ 25 u.c. Within this window, the device capacitance corresponds well to the expected geometric value, while for thicknesses outside this window, the capacitance is strongly suppressed. The ability to modulate electronic and magnetic properties of LAO/STO devices depends on the ability to control carrier density, which is in turn constrained by intrinsic tunneling mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate measurements and temperature dependence of the water vapor self-continuum absorption in the 2.1 μm atmospheric window

In spite of its importance for the evaluation of the Earth radiative budget, thus for climate change, very few measurements of the water vapor continuum are available in the near infrared atmospheric windows especially at temperature conditions relevant for our atmosphere. In addition, as a result of the difficulty to measure weak broadband absorption signals, the few available measurements show large disagreements. We report here accurate measurements of the water vapor self-continuum absorption in the 2.1 μm window by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) for two spectral points located at the low energy edge and at the center of the 2.1 μm transparency window, at 4302 and 4723 cm{sup −1}, respectively. Self-continuum cross sections, C{sub S}, were retrieved with a few % relative uncertainty, from the quadratic dependence of the spectrum base line level measured as a function of water vapor pressure, between 0 and 16 Torr. At 296 K, the C{sub S} value at 4302 cm{sup −1} is found 40% higher than predicted by the MT-CKD V2.5 model, while at 4723 cm{sup −1}, our value is 5 times larger than the MT-CKD value. On the other hand, these OF-CEAS C{sub S} values are significantly smaller than recent measurements by Fourier transform spectroscopy at room temperature. The temperature dependence of the self-continuum cross sections was also investigated for temperatures between 296 K and 323 K (23-50 °C). The derived temperature variation is found to be similar to that derived from previous Fourier transform spectrometer (FTS) measurements performed at higher temperatures, between 350 K and 472 K. The whole set of measurements spanning the 296-472 K temperature range follows a simple exponential law in 1/T with a slope close to the dissociation energy of the water dimer, D{sub 0} ≈ 1100 cm{sup −1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma window performance and scaling for an accelerator-based neutron source

A “plasma window” was developed for use with a SHINE accelerator-based neutron source. In this work, the design of the plasma window is presented along with results demonstrating successful operation in deuterium over a range of aperture diameters (5–12 mm), gas flow rates (3.5 to 12.5 slm), and input powers (10–55 kW). Here, an empirically determined relationship between the aperture diameter, deuterium gas flow rate, input power, and plasma window pressure differential is also presented.

43 PARTICLE ACCELERATORS↗

The role of sample–window coupling in shock temperature experiments

Radiometric studies of opaque materials under shock compression probe a sample–window interface that may be very different than the bulk state. Subtle experimental details, particularly an initial sample–window gap vs an adhesively bonded stack, have tremendous influence on measured temperature. This work experimentally tests gapped vs bonded targets and theoretically investigates observed differences in the measured temperature. The results indicate that perturbations created by a thin adhesive are smaller than those suggested by a previous work, whereas sample–window gaps alter the measured state more significantly than that previously realized.

Adhesives↗

Prevention of Residual Gas Condensation on the Laser Entry Hole Windows on Cryogenic NIF Targets Using a Protective Warm Film

Many of the early cryogenic shots on NIF were plagued by buildup of considerable mass of extraneous ice on the LEH windows, a consequence of condensation of the residual air in the surrounding chamber. Thickness of this ice depended on the exact chamber pressure and the target fielding time duration, both extremely difficult to keep constant given the broad range of target types being shot. In this paper, we describe our work in designing a robust solution in the form of a second thin film that shielded the LEH window from the contaminating ice. Several detailed cryogenic considerations were required to ensure the proper functioning of this new window, which were simulated and verified experimentally. Data from numerous subsequent shots showed marked improvement in performance, which made this new feature an essential component for all cryogenic NIF targets.

36 MATERIALS SCIENCE↗

Fabrication of flat SiGe heterostructure nanomembrane windows via strain-relief patterning

The lattice mismatch between SiGe and Si in heteroepitaxial Si/SiGe/Si trilayers leads to buckling when confined nanomembrane windows formed from these heterostructures are released from silicon-on-insulator substrates. We demonstrate that large areas in which the curvature and curvature-induced strain are reduced by an order of magnitude can be produced by patterning the windows to concentrate buckling in narrow arms with low flexural rigidity supporting a flat central region. Synchrotron x-ray thermal diffuse scattering shows that the improved flatness of patterned windows permits fundamental studies with fidelity similar to what can be achieved with flat single-component Si nanomembranes.

buckling↗

Observational window effects on multi-object reverberation mapping

ABSTRACT Contemporary reverberation mapping campaigns are employing wide-area photometric data and high-multiplex spectroscopy to efficiently monitor hundreds of active galactic nuclei (AGNs). However, the interaction of the window function(s) imposed by the observation cadence with the reverberation lag and AGN variability time-scales (intrinsic to each source over a range of luminosities) impact our ability to recover these fundamental physical properties. Time dilation effects due to the sample source redshift distribution introduce added complexity. We present comprehensive analysis of the implications of observational cadence, seasonal gaps, and campaign baseline duration (i.e. the survey window function) for reverberation lag recovery. We find that the presence of a significant seasonal gap dominates the efficacy of any given campaign strategy for lag recovery across the parameter space, particularly for those sources with observed-frame lags above 100 d. Using the Australian Dark Energy Survey as a baseline, we consider the implications of this analysis for the 4MOST/Time-Domain Extragalactic Survey campaign providing concurrent follow-up of the Legacy Survey of Space and Time deep-drilling fields, as well as upcoming programmes. We conclude that the success of such surveys will be critically limited by the seasonal visibility of some potential field choices, but show significant improvement from extending the baseline. Optimizing the sample selection to fit the window function will improve survey efficacy.

79 ASTRONOMY AND ASTROPHYSICS↗

Data-driven results for light-quark connected and strange-plus-disconnected hadronic g − 2 short- and long-distance windows

A key issue affecting the attempt to reduce the uncertainty on the Standard Model prediction for the muon anomalous magnetic moment is the current discrepancy between lattice-QCD and data-driven results for the hadronic vacuum polarization. Progress on this issue benefits from precise data-driven determinations of the isospin-limit light-quark-connected (lqc) and strange-plus-light-quark-disconnected ( s + lqd ) components of the related RBC/UKQCD windows. In this paper, using a strategy employed previously for the intermediate window, we provide data-driven results for the lqc and s + lqd components of the short- and long-distance RBC/UKQCD windows. Comparing these results with those from the lattice, we find significant discrepancies in the lqc parts but good agreement for the s + lqd components. We also explore the impact of recent CMD- 3 e + e − → π + π − cross section results, demonstrating that an upward shift in the ρ -peak region of the type seen in the CMD-3 data serves to eliminate the discrepancies for the lqc components without compromising the good agreement between lattice and data-driven s + lqd results. Published by the American Physical Society 2025

Benton, Genessa (ORCID:0009000515763654)↗

Hadronic vacuum polarization for the muon 𝑔 − 2 from lattice QCD: Complete short and intermediate windows

We present complete results for the hadronic vacuum polarization (HVP) contribution to the muon anomalous magnetic moment 𝑎 𝜇 in the short- and intermediate-distance window regions, which account for roughly 10% and 35% of the total HVP contribution to 𝑎 𝜇 , respectively. In particular, we perform lattice-QCD calculations for the isospin-symmetric connected and disconnected contributions, as well as corrections due to strong-isospin breaking. For the short-distance window observables, we investigate the so-called log-enhancement effects as well as the significant oscillations associated with staggered quarks in this region. For the dominant, isospin-symmetric light-quark-connected contribution, we obtain 𝑎$^{𝑙⁢𝑙,SD}_{𝜇⁡}$(conn) = 48.139⁢(11) stat ⁢(91) syst ⁢[92] total × 10 −10 and 𝑎$^{𝑙⁢𝑙,W}_{𝜇}$⁡(conn) = 206.90⁢(14) stat ⁢(61) syst ⁢[63] total × 10 −10 . We use Bayesian model averaging to fully estimate the covariance matrix between the individual contributions. Our determinations of the complete window contributions are 𝑎$^{SD}_{𝜇}$ = 69.05⁢(1) stat⁢ (21) syst ⁢[21] total × 10 −10 and 𝑎$^{W}_{𝜇}$ = 236.45⁢(17) stat⁢ (83) syst ⁢[85] total × 10 −10 . This work is part of our ongoing effort to compute all contributions to HVP with an overall uncertainty at the few-permille level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation attenuation by single-crystal diamond windows

As artificial diamond becomes more cost effective it is likely to see increasing use as a window for sample environment equipment used in diffraction experiments. Such windows are particularly useful as they exhibit exceptional mechanical properties in addition to being highly transparent to both X-ray and neutron radiation. A key application is in high-pressure studies, where diamond anvil cells (DACs) are used to access extreme sample conditions. However, despite their utility, an important consideration when using single-crystal diamond windows is their interaction with the incident beam. In particular, the Bragg condition will be satisfied for specific angles and wavelengths, leading to the appearance of diamond Bragg spots on the diffraction detectors but also, unavoidably, to loss of transmitted intensity of the beam that interacts with the sample. This effect can be particularly significant for energy-dispersive measurements, for example, in time-of-flight neutron diffraction work using DACs. Furthermore, this article presents a semi-empirical approach that can be used to correct for this effect, which is a prerequisite for the accurate determination of diffraction intensities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-physics simulations of particle tracking in arterial geometries with a scalable moving window algorithm

In arterial systems, cancer cell trajectories determine metastatic cancer locations; similarly, particle trajectories determine drug delivery distribution. Predicting trajectories is challenging, as the dynamics are affected by local interactions with red blood cells, complex hemodynamic flow structure, and downstream factors such as stenoses or blockages. Direct simulation is not possible, as a single simulation of a large arterial domain with explicit red blood cells is currently intractable on even the largest supercomputers. To overcome this limitation, we present a multi-physics adaptive window algorithm, in which individual red blood cells are explicitly modeled in a small region of interest moving through a coupled arterial fluid domain. We describe the coupling between the window and fluid domains, including automatic insertion and deletion of explicit cells and dynamic tracking of cells of interest by the window. We show that this algorithm scales efficiently on heterogeneous architectures and enables us to perform large, highly-resolved particle-tracking simulations that would otherwise be intractable.

Herschlag, Gregory↗

Breakdown in ceramic window

A capacitive type coaxial ceramic window is designed for the SC linac. The coaxial power coupler has inner conductor diameter 34.8 mm and outer conductor diameter 80 mm. An alumina disk of diameter 150 mm and thickness 3.6 mm is used as ceramic. The diameter of the inner conductor of the coupler near the ceramic is increased to 39.2 mm to match the impedance at 1050 MHz. A copper prototype of the window is fabricated and characterized. A performance of the window is often degraded because of the multipacting. A CST particle studio is used to simulate the multipacting trajectories. The particle trajectories are observed at different locations and different power levels up to 1 MW. The results are dependent on the initial position of the primary electron and power level. A few soft multipacting barriers are observed at the operating power level. (author)

43 PARTICLE ACCELERATORS↗

Effects of Wire Diameter and Filament Size on the Processing Window of Bi-2212 Round Wire

High engineering critical current density (J E of 1300 A/mm 2 at 4.2 K and 15 T) in Bi-2212 round wire has been achieved through a partial melt, overpressure heat treatment process. J E varies strongly with processing conditions, particularly the maximum heat treatment temperature (T max ). Increasing T max results in longer time in the melt (defined as the time between when Bi-2212 melts on heating and when Bi-2212 begins to form on cooling), more bridging between the filaments, lower J E , and higher ac losses. A wide processing window with a large range of T max that has a nearly constant J E is desired for processing large coils with large thermal mass and significant thermal time constants that may make precise control over the desired temperature – time profiles uncertain. Accordingly, we wanted to explore broadening the T max window by controlling the Bi-2212 powder melting or wire architecture design. In this work, we report on studies of the performance variation with T max for two production wires with a filling factor of about 20% and 85 × 18 filaments where filament size was varied by changing the wire diameter, a process which also shortens the distance between filaments. We found that wires with smaller filament diameter (9 to 11 μm) showed a peak J E at the low end of T max and also a J E that was more sensitive to T max . A J E – T max plot showed a plateau J E (4.2 K, 5 T) of ~1100 A/mm 2 between T max of 886 and 894 °C for 1.0 and 1.2 mm wires, where J E is less sensitive to the wire diameter and T max . This J E plateau range is a preferred processing window for achieving high J E in coils.

36 MATERIALS SCIENCE↗

SU-E-T-478: Sliding Window Multi-Criteria IMRT Optimization

Purpose: To demonstrate a method for what-you-see-is-what-you-get multi-criteria Pareto surface navigation for step and shoot IMRT treatment planning. Methods: We show mathematically how multiple sliding window treatment plans can be averaged to yield a single plan whose dose distribution is the dosimetric average of the averaged plans. This is incorporated into the Pareto surface navigation based approach to treatment planning in such a way that as the user navigates the surface, the plans he/she is viewing are ready to be delivered (i.e. there is no extra ‘segment the plans’ step that often leads to unacceptable plan degradation in step and shoot Pareto surface navigation). We also describe how the technique can be applied to VMAT. Briefly, sliding window VMAT plans are created such that MLC leaves paint out fluence maps every 15 degrees or so. These fluence map leaf trajectories are averaged in the same way the static beam IMRT ones are. Results: We show mathematically that fluence maps are exactly averaged using our leaf sweep averaging algorithm. Leaf transmission and output factor corrections effects, which are ignored in this work, can lead to small errors in terms of the dose distributions not being exactly averaged even though the fluence maps are. However, our demonstrations show that the dose distributions are almost exactly averaged as well. We demonstrate the technique both for IMRT and VMAT. Conclusions: By turning to sliding window delivery, we show that the problem of losing plan fidelity during the conversion of an idealized fluence map plan into a deliverable plan is remedied. This will allow for multicriteria optimization that avoids the pitfall that the planning has to be redone after the conversion into MLC segments due to plan quality decline. David Craft partially funded by RaySearch Laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the optimal tolerance for MLC positioning in sliding window and VMAT techniques

Purpose: Several authors have recommended a 2 mm tolerance for multileaf collimator (MLC) positioning in sliding window treatments. In volumetric modulated arc therapy (VMAT) treatments, however, the optimal tolerance for MLC positioning remains unknown. In this paper, the authors present the results of a multicenter study to determine the optimal tolerance for both techniques. Methods: The procedure used is based on dynalog file analysis. The study was carried out using seven Varian linear accelerators from five different centers. Dynalogs were collected from over 100 000 clinical treatments and in-house software was used to compute the number of tolerance faults as a function of the user-defined tolerance. Thus, the optimal value for this tolerance, defined as the lowest achievable value, was investigated. Results: Dynalog files accurately predict the number of tolerance faults as a function of the tolerance value, especially for low fault incidences. All MLCs behaved similarly and the Millennium120 and the HD120 models yielded comparable results. In sliding window techniques, the number of beams with an incidence of hold-offs >1% rapidly decreases for a tolerance of 1.5 mm. In VMAT techniques, the number of tolerance faults sharply drops for tolerances around 2 mm. For a tolerance of 2.5 mm, less than 0.1% of the VMAT arcs presented tolerance faults. Conclusions: Dynalog analysis provides a feasible method for investigating the optimal tolerance for MLC positioning in dynamic fields. In sliding window treatments, the tolerance of 2 mm was found to be adequate, although it can be reduced to 1.5 mm. In VMAT treatments, the typically used 5 mm tolerance is excessively high. Instead, a tolerance of 2.5 mm is recommended.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-JeP1-15: Sliding Window Prior Data Assisted Compressed Sensing for MRI Lung Tumor Tracking

Purpose: Prior Data Assisted Compressed Sensing (PDACS) is a partial k-space acquisition and reconstruction method for mobile tumour (i.e. lung) tracking using on-line MRI in radiotherapy. PDACS partially relies on prior data acquired at the beginning of dynamic scans, and is therefore susceptible to artifacts in longer duration scan due to slow drifts in MR signal. A novel sliding window strategy is presented to mitigate this effect. Methods: MRI acceleration is simulated by retrospective removal of data from the fully sampled sets. Six lung cancer patients were scanned (clinical 3T MRI) using a balanced steady state free precession (bSSFP) sequence for 3 minutes at approximately 4 frames per second, for a total of 650 dynamics. PDACS acceleration is achieved by undersampling of k-space in a single pseudo-random pattern. Reconstruction iteratively minimizes the total variations while constraining the images to satisfy both the currently acquired data and the prior data in missing k-space. Our novel sliding window technique (SW-PDACS), uses a series of distinct pseudo-random under-sampling patterns of partial k-space – with the prior data drawn from a sliding window of the most recent data available. Under-sampled data, simulating 2 – 5x acceleration are reconstructed using PDACS and SW-PDACS. Three quantitative metrics: artifact power, centroid error and Dice’s coefficient are computed for comparison. Results: Quantitively metric values from all 6 patients are averaged in 3 bins, each containing approximately one minute of dynamic data. For the first minute bin, PDACS and SW-PDACS give comparable results. Progressive decline in image quality metrics in bins 2 and 3 are observed for PDACS. No decline in image quality is observed for SW-PDACS. Conclusion: The novel approach presented (SW-PDACS) is a more robust for accelerating longer duration (>1 minute) dynamic MRI scans for tracking lung tumour motion using on-line MRI in radiotherapy. B.G. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Multipacting analysis of the SNS drift tube linac (DTL) RF vacuum window using Spark3d

An ongoing study at the Spallation Neutron Source (SNS) seeks to better understand and address potential multipacting issues associated with the Drift Tube Linac (DTL) RF vacuum windows. An analysis of several failed operational windows showed indications of excessive RF heating on the TiN-coated alumina ceramics. Coupled with vacuum bursts and arcing during conditioning and/or operational periods, these problems have been attributed to electron activity likely caused by multipacting. The status of the study, 3-D electromagnetic simulation results, mitigating techniques and a future experimental plan for studying multipacting in the SNS DTL vacuum windows are presented.

Toby, George↗

Comparison of the Window-Frame RHIC-abort kicker with C-type Kicker

The high intensity proton bunches (~2.5x10 11 p/bunch ) circulating in RHIC increase the temperature of the ferrite-made RHIC-abort-kickers above the Curie point; as a result, the kickers cannot provide the required field to abort the beam at the beam dump. A team of experts in the CAD department worked on modifying the design of the window-frame RHIC-abort kicker to minimize the hysteresis losses responsible for the increase of the ferrite’s temperature. In this technical note we report some results from the study of two possible modifications of the window-frame RHIC-abort kicker, and we compare these results with those of a propose C-type RHIC-abort kicker. We also include an Appendix where we describe a method which may further reduce the hysteresis losses of the window-frame kicker.

43 PARTICLE ACCELERATORS↗