Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WHISPER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Temperature switching of cavity modes in InN microcrystals

InN optical cavities supporting low-order whispering-gallery modes up to room temperature are formed by molecular-beam epitaxy on patterned substrates. The observed switching of the mode type with increasing temperature is explained in terms of changes in the optical parameters due to a shift of the absorption edge and modification of its shape. Modeling taking into account a variation in the refractive index reproduces the typical distributions of the electromagnetic-field intensity in the cavities.

36 MATERIALS SCIENCE↗

THz Stimulated Emission from Simple Superlattice in Positive Differential Conductivity Region

Narrow band emissions at 2.6–2.8 THz are observed out of liquid helium cooled 1 mm disk chips prepared of a wafer with the very low n type doped weak barrier GaAs–GaAlAs superlattice of 1000 periods. The emissions are at about 8.0–18.0 V pulsed voltage applied to the chips in region of the chips positive DC differential conductivity that guaranties absence of inhomogeneous electric field domains in the chips. The emission frequency bands are estimated with a cyclotron resonance filter; the measurements show that the band width is of about that of the THz quantum cascade laser. By using long voltage pulses the chip heating above 100 K is achieved without substantial change in emission power. We speculate that the emission is super luminescence (amplification) of whispering gallery modes in the chips as a result of inverted Wannier-Stark level transitions under bias. The results are the first world demonstration of THz stimulated emission in a simple superlattice within region of positive DC differential conductivity; they give strong impetus for development of THz and higher frequency sources based on such simple superlattices; the sources should well compete with the THz quantum cascade lasers in particular at elevated temperatures.

36 MATERIALS SCIENCE↗

Aerosol Synthesis of Highly Dispersed Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+} Phosphor with Intense Photoluminescence

A simple method of pyrolysis of an aerosol solution of yttrium, aluminum, and cerium nitrates with the addition of urea or citric acid, followed by brief annealing, is developed to obtain a highly dispersed aluminum–yttrium garnet powder that demonstrates intense photoluminescence in the visible light region. Characterization of the synthesized samples (photoluminescence spectra, X-ray diffraction analysis, Raman spectra) showed that intense photoluminescence is achieved only in a narrow window of process conditions, namely, the concentration of nitrate solution and the concentration of citric acid or urea. The photoluminescence intensity increases upon annealing synchronously with an increase in the crystallite size, which, along with the optimal cerium concentration (~0.5 at %), is a determining factor for obtaining high-quality samples. The synthesized powders had intense photoluminescence and high optical perfection, as evidenced by the observation of whispering gallery modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-Time Tracking of Carbon Dioxide Concentration Using an Optical Microsphere Resonator Sensor

Whispering gallery mode resonator sensors are nondisruptive optical sensors that can detect and monitor perturbations in a gaseous environment. Through its resonant properties of peak wavelength, amplitude, and quality factor (Q factor), changes in concentration can be quantified within seconds and monitored over days with great stability. In addition, the small footprint, low cost, and high sensitivity are ideal properties for a disposable sensor that can be utilized in extreme environments. Further, the large Q factor of the resonant cavity enables long interaction lengths and amplifies the effect of small changes in the background refractive index, which is detectable in picometer shifts of the resonance wavelength. However, this measurement is susceptible to changes in other environmental factors such as temperature, pressure, and humidity, which manifest on the picometer wavelength scale, reinforcing the need to decouple the variables. In this work, we compare the spectral response of different diameter resonators to carbon dioxide, nitrogen, and its mixtures, observing the spectral shifting and broadening of the cavity resonance near 1550 nm. In addition, the effect of environmental temperature on spectral shifting due to the thermo-optic effect is characterized and quantified. Lastly, the gas concentrations are changed in real time to showcase the tracking and recovery capabilities of the resonator sensor.

47 OTHER INSTRUMENTATION↗

Validation of MCNP Critical Benchmark Models of Moderated Highly Enriched Uranium Slabs

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The benchmark experiments are described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and the initial set of benchmark models are derived from the Whisper Suite provided with MCNP6.2. This effort is a collaboration among the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with HEU-MET-FAST-007, “Uranium Metal Slabs Moderated with Polyethylene, Plexiglas, and Teflon”. The Monte Carlo n-Particle (MCNP) models were compared to the second revision of HEU-MET-FAST-007. The experiment considered critical configurations of highly enriched uranium (HEU) metal slabs and various moderators in 43 unique cases. The slabs of uranium were separated by layers of moderating material, forming an assembly. The assembly was separated in two halves with one half placed on a stationary table and the other attached to a moveable table that could be raised and lowered via pulleys connected to the ceiling of the shielded room. To reach criticality, the two halves were brought together with a negligible gap between the assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated reference cavity with dual-mode optical thermometry for frequency correction

Photonic integrated resonators have advantages over traditional benchtop cavities in terms of size, weight, and cost with the potential to enable applications that require spectrally pure light. However, integrated resonators suffer from temperature-dependent frequency variations and are sensitive to external environmental perturbations, which hinders their usage in precision frequency applications. One solution is to use interrogation of the cavity temperature through dual-mode optical thermometry (DMOT) by measuring the shift of the resonance frequency difference between two polarization or optical frequency modes. Yet this approach has only been demonstrated in bulk-optic whispering gallery mode and fiber resonators. In this paper, we implement dual-mode optical thermometry in an ultra-high Q integrated silicon nitride resonator. A dual-mode resonance frequency difference temperature sensitivity of 188 ± <#comment/> 15 M H z / K is measured. We demonstrate feedforward DMOT frequency correction that, under an applied external temperature ramp, is able to reduce the optical frequency change to 0.31 kHz/s as compared to an uncorrected 10.03 kHz/s, a factor of 30 × <#comment/> reduction. These results show promise for on-chip frequency correction solutions for quantum, metrology, atomic, and coherent optical communications applications.

Zhao, Qiancheng (ORCID:0000000206968667)↗

Advanced Output Coupling for High Power Gyrotrons

The Phase II program developed an internal RF coupler that transforms the whispering gallery RF mode produced in gyrotron cavities to an HE11 waveguide mode propagating in corrugated waveguide. This power is extracted from the vacuum using a broadband, chemical vapor deposited (CVD) diamond, Brewster angle window capable of transmitting more than 1.5 MW CW of RF power over a broad range of frequencies. This coupling system eliminates the Mirror Optical Units now required to externally couple Gaussian output power into corrugated waveguide, significantly reducing system cost and increasing efficiency. The program simulated the performance using a broad range of advanced computer codes to optimize the design. Both a direct coupler and Brewster angle window were built and tested at low and high power. Test results confirmed the performance of both devices and demonstrated they are capable of achieving the required performance for scientific, defense, industrial, and medical applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Machine Learning to Predict MCNP Bias

For many real-world applications in radiation transport where simulations are compared to experimental measurements, like in nuclear criticality safety, the bias (simulated - experimental k eff ) in the calculation is an extremely important quantity used for code validation. The objective of this project is to accurately predict the bias of MCNP6 [1] criticality calculations using machine learning (ML) algorithms, with the intention of creating a tool that can complement the current nuclear criticality safety methods. In the latest release of MCNP6, the Whisper tool is available for criticality safety analysts and includes a large catalogue of experimental benchmarks, sensitivity profiles, and nuclear data covariance matrices. This data, coming from 1100+ benchmark cases, is used in this study of ML algorithms for criticality safety bias predictions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Verification of the MCNP6.2 Release for Nuclear Criticality Safety Applications

MCNP6.2 was released in 2018 and is the latest production release of MCNP ® available from RSICC. Previous releases were MCNP6.1 [3] in 2013 and MCNP6.1.1 in 2014. MCNP6.2 includes all of the standard features for NCS calculations that have been available for the past 15 years, along with new features for sensitivity-uncertainty based methods using Whisper for NCS validation

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Piezoelectric Nano-Optomechanical Systems

Lithium niobate, due to its material properties, is often used for optical waveguides, optical modulators, and other linear and nonlinear optical applications. In this research, we present monolithically integrated microdisk resonators with an integrated ground plane fabricated from a commercially purchased lithium niobate on insulator wafer. Using this architecture, we demonstrate excitation of a 167MHz mechanical resonance as well as electro-optic modulation of a 1.93THz optical mode in a free-standing whispering gallery mode (WGM) resonator. By hovering a signal probe above the disk while grounding the device using the integrated ground plane, an electric field can be applied across the device which both induces an electro-optic effect as well as drives mechanical motion via the piezoelectric effect. Detection of the mechanical mode and electro-optic shift was performed by coupling to the high quality factor (Q = 454,000) optical modes of the microresonator using a tapered optical fiber.

42 ENGINEERING↗

Verification of MCNP6.2 with ENDF/B-VIII.0 Nuclear Data for Nuclear Criticality Safety Applications

MCNP6.2 was released in 2018 and is the latest production release of MCNP ® available from RSICC. MCNP6.2 includes all of the standard features for nuclear criticality safety (NCS) calculations that have been available for the past 15 years, along with new features for sensitivity-uncertainty based methods using Whisper for NCS validation. MCNP6.2 verification using ENDF/B-VII.1 nuclear data was previously reported in. This report focuses on the initial testing and verification of MCNP6.2 using the ENDF/B-VIII.0 nuclear data that were released in 2018. The sections that follow provide guidance for NCS users on modifying existing MCNP input files to use the new ENDF/B-VIII.0 ACE nuclear data, discussion of results for several ICSBEP-based benchmark suites using MCNP6.2 with ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical Experiment Benchmark Results using MCNP6.2 Unstructured Mesh

The purpose of this report is to document the results of five critical experiment benchmarks modeled using the unstructured mesh (UM) geometry capability in MCNP®1 code, version 6.2. LANL currently has a vast critical experiment benchmark library with over 1100 cases, modeled using constructive solid geometry (CSG) and packaged with Whisper-1.1. Validation efforts for the purposes of nuclear criticality safety typically focus on benchmark libraries built using CSG models. Results of UM geometry models are compared with CSG results and the critical experiment k-effective from the ICSBEP handbook. All computed k-effective results in this study are well within 1% of the experimental result.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Comparative Analysis of Confidence Metrics for Nuclear Criticality Safety

Nuclear criticality safety standards provide guidance on the requirements and recommendations to establish confidence in computerized model results used to support operation with fissionable materials. By design, the guidance is not prescriptive, leaving the analysts free to determine how various sources of uncertainties are to be statistically aggregated. This report compares the analyses and key assumptions behind four notable methodologies documented in the nuclear criticality safety literature: the parametric, nonparametric, Whisper, and TSURFER methodologies. Because of the involved use of statistics entangled with heuristic recipes, the results of these methodologies are often difficult to interpret. Also, they are augmented by additional large administrative margins, eliminating the incentive to understand their differences. With the new resurgent wave of advanced nuclear systems focused on economizing operation—including advanced reactors, fuel cycles, and fuel concepts—there is a strong need to develop a clear understanding of uncertainties and their fusion methodologies to reduce uncertainties in a scientifically defensible manner. This report offers a deep dive into the various assumptions of the four noted methodologies, their adequacy, and their limitations, to provide guidance on developing confidence for the emergent nuclear systems. These systems are expected to be challenged by the scarcity of experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement and analysis of a microwave oscillator stabilized by a sapphire dielectric ring resonator for ultra-low noise

Phase-noise measurements are presented for a microwave oscillator whose frequency is stabilized by a whispering-gallery sapphire ring resonator with Q of 200,000. This mode involves little metallic conduction and allows nearly full use of the very low dielectric loss in sapphire. Several mode families have been identified, in good agreement with frequency calculations. For a 5-cm wheel resonator in a 7.6-cm container, Q values above 100,000 were found at room temperature for all of the modes in this sequence. Coupling Q-values for these same modes ranged from 10,000 (n = 5) to 100,000 (n = 10) for a WR112 waveguide port at the center of the cylinder wall of the containing can. Phase noise measurements for a transistor oscillator locked to the n = 10 (7.84-GHz) mode showed a 1/f cubed dependence for low offset frequencies, and a value of L(f) = -55 dB/Hz at an offset of 10 Hz from the carrier.

Dick, G. John↗

Sapphire Ring Resonator For Microwave Oscillator

Sapphire dielectric ring resonator operating in "whispering-gallery" mode helps to stabilize frequency and phase of microwave oscillator. Reduces phase noise appreciably at room temperature and promises unprecedented stability of phase at cryogenic temperatures.

Dick, G. John↗