Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Early MRI Blood Volume Changes in Constrictor Muscles Correlate With Postradiation Dysphagia

Predicting individual patient sensitivity to radiation therapy (RT) for tumor control or normal tissue toxicity is necessary to individualize treatment planning. In head and neck cancer, radiation doses are limited by many nearby critical structures, including structures involved in swallowing. Previous efforts showed that imaging parameters correlate with RT dose; here, we investigate the role of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) blood volume (BV) changes in predicting dysphagia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interdisciplinary Clinical Target Volume Generation for Cardiac Radioablation: Multicenter Benchmarking for the RAdiosurgery for VENtricular TAchycardia (RAVENTA) Trial

Cardiac radioablation is a novel treatment option for therapy-refractory ventricular tachycardia (VT) ineligible for catheter ablation. Three-dimensional clinical target volume (CTV) definition is a key step, and this complex interdisciplinary procedure includes VT-substrate identification based on electroanatomical mapping (EAM) and its transfer to the planning computed tomography (PCT). Benchmarking of this process is necessary for multicenter clinical studies such as the RAVENTA trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm

To comprehensively characterize dosimetric differences between calculations with a commercial model-based dose calculation algorithm (MBDCA) and the TG-43 formalism in application to accelerated partial breast irradiation (APBI) with the strut-adjusted volume implant (SAVI) applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Irradiated Brain Volume Within 12 Gy Is a Predictor for Radiation-Induced Changes After Stereotactic Radiosurgery in Patients With Unruptured Cerebral Arteriovenous Malformations

Our purpose was to determine whether the coverage of brain parenchyma within the 12 Gy radiosurgical volume (V12) correlates with the development of radiation-induced changes (RICs) in patients with unruptured cerebral arteriovenous malformations (AVM) after undergoing stereotactic radiosurgery (SRS).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Asymptotic-preserving semi-implicit finite volume scheme for extended magnetohydrodynamics

A Finite Volume (FV) scheme is developed for solving the extended magnetohydrodynamic (XMHD) equations, yielding accurate results in the ideal, resistive, and Hall MHD limits. This is accomplished by first re-writing the XMHD equations such that it allows the algorithm to retain the use of ideal MHD Riemann solvers and the constrained transport method to preserve divergence-free magnetic fields. Incorporation of electron inertia and displacement current introduces additional numerical stiffness which motivates a semi-implicit FV scheme that re-formulates the XMHD model as a relaxation system. The equations are then advanced in time using an explicit 2nd-order Runge–Kutta scheme with operator splitting applied to the implicit source term updates at each sub-stage. For additional numerical stability, a density-dependent slope limiter is implemented to increase flux diffusivity at low density regions where non-ideal effects become significant. The algorithm is subsequently implemented in a scalable adaptive mesh refinement (AMR) framework. As the new algorithm retains many aspects of the ideal MHD formulations, it asymptotes naturally to the ideal MHD limit. Moreover, it shows promising results at the resistive and Hall MHD limits. This is verified against reference test problems for ideal, resistive and Hall MHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory

For this study, ultra-low-level measurements of radionuclides in air have been conducted at the Savannah River National Laboratory (SRNL) to determine the atmospheric concentration of fission products released following the Fukushima Daiichi reactor accident on March 11, 2011. Air filter samples were acquired from two high-volume collection systems (a traditional filter-based system and an electrostatic precipitator-based system) to monitor airborne radionuclide concentrations in the period covering from 2 weeks to 3 years after the disaster. The world-wide spread of low-level concentrations of airborne fission products from the Fukushima event provided a unique opportunity to demonstrate SRNL's electrostatic particle collection technology and other improvements in environmental monitoring developed at the Savannah River Site (SRS). Detecting and analyzing the release allowed a comprehensive test of SRS systems for monitoring environmental radioactivity. Gamma-ray-emitting fission products ( 131,132 I, 134,136,137 Cs, and 129,132 Te) and cosmogenic isotopes ( 7 Be and 22 Na) in air were detected and quantified by high-resolution gamma-ray spectroscopy at concentrations as low as 0.07 μBq per standard cubic meter (SCM) (50 mBq total 137 Cs), while plutonium content was quantified by thermal ionization mass spectrometry (TIMS) at concentrations as low as 6.5 × 10 –21 g/SCM (3.0 fg 239+240 Pu). Isotope concentrations measured at SRNL from gamma-ray spectroscopy were compared to independent measurements from Chapel Hill, NC, located approximately 370 km (230 mi) NE of SRNL. Meteorological modeling was also used to predict radionuclide transport from the location of release to both measurement locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Multi-faceted framework for extrapolating early age flexural strength to facilitate rapid lifting/handling of high-volume fly ash precast members

Maintaining adequate early-age structural performance for precast concrete components has grown in importance as more sustainable mix designs become more widespread. Achieving high-early flexural strength is particularly crucial to facilitate rapid removal of hardened concrete components from formwork, often within 24 h after fresh concrete placement. Limited research has assessed the effectiveness of traditional design methods in correlating flexural strength with compressive strength for next-generation mix designs, or demonstrated extrapolation of such material performance to larger-scale structural tests. This paper presents a multi-faceted framework to reassess early-age flexural strength for concretes made with relatively high proportions of fly ash from both fresh and harvested sources. Here, the framework provides several pathways, from which the user can select based upon available resources and the specific application, to improve accuracy of early-age cracking moment calculations. Furthermore, the scope includes evaluation of strength performance under curing conditions emulative of those in a precast facility, recommending modulus of rupture equations which are more performance-driven than current design provisions, and experimental tests on prefabricated concrete beams to validate the proposed methodologies. Correlations of early-age strength with both concrete age and maturity measurements compare the effectiveness of utilizing in-situ data to further enhance the prediction methods. Ultimately, the proposed framework helped reduce errors when calculating cracking moment capacity at early ages by tailoring calculations to reflect mix-dependent behavior. Furthermore, most estimates of cracking moment were within 25 % of their corresponding experimental test results, thus promoting confidence for using these strategies with high-volume fly ash precast structures.

42 ENGINEERING↗

Enhancing the accuracy and generality of the Debye–Grüneisen Model: Optimizing the volume dependence for accurate predictions across varied compositions

In this work, we have introduced an optimized Debye-Grüneisen model that revolutionizes the determination of the Debye temperature and Grüneisen parameters. Unlike conventional methods, our model requires only the 0 K energy volume data for a material as input, eliminating the need to determine the bulk modulus and its pressure derivative, which often pose challenges due to numerical uncertainties. This unique feature sets our model apart from existing approaches and streamlines the process, enabling accurate predictions of thermal expansion behavior across various materials. To demonstrate its effectiveness, we showcase its excellent agreement with measured coefficients of thermal expansion (CTE) for the nickel-cobalt-chromium-aluminum-yttrium (Ni-Co-Cr-Al-Y) bond-coating system. Additionally, we apply our approach by conducting a high-throughput search for potential bond-coating materials among 90,000 compositions within the aluminum-cobalt-chromium-iron-nickel (Al-Co-Cr-Fe-Ni) system. From this extensive search, four compositions are synthesized, and the measured CTE values agree very well with theoretical predictions, hence validating our approach. In conclusion, the current optimized Debye-Grüneisen model combined with Density Functional Theory (DFT)-based thermodynamic database enables reliable and efficient high-throughput calculations of CTE of of a material without expensive phonon calculations.

Bond coating materials↗

High volume packing fraction TRISO-based fuel in light water reactors

We report that for a decade, fully ceramic microencapsulated (FCM) fuel, containing tri-structural isotropic (TRISO) fuel particles in a silicon carbide (SiC) matrix, has been investigated as an accident-tolerant fuel for light water reactors (LWRs). Other examples exist of TRISO-based concepts for LWR fuels with different matrix materials. Previous studies assumed TRISO particle volume packing of approximately 0.44 in SiC (or another) matrix, the highest realistic packing fractions possible with conventional manufacturing. Recent advances in advanced manufacturing have yielded the development and demonstration of a fuel form that consists of conventionally manufactured TRISO particles in a 3D-printed SiC matrix with significantly higher possible TRISO packing fractions (0.5–0.7). This increased uranium loading enhances the viability of using TRISO-based particle fuel forms in LWRs. The viability of high-packing-fraction TRISO-based particle fuel forms in LWRs is assessed from the perspective of fuel cycle length, achievable fuel burnup, reactivity coefficients, and fuel cycle performance. Higher-packing-fraction TRISO-based fuel enables either longer cycle lengths (by ~25% at a packing fraction of 0.55 relative to 0.44) at a constant enrichment or decreased enrichments (by ~25% at a packing fraction of 0.55 relative to 0.44) at a constant cycle length. Studies of different fuel kernel types (uranium nitride, uranium oxycarbide, and uranium carbide) yield similar results, although the cycle length of uranium oxycarbide is shorter than for uranium nitride or uranium carbide (due to the lower density of uranium oxide). This work also characterized the production of 14 C resulting from neutron absorption in 14 N during operation for uranium mononitride fuel kernels; the ratio of 14 C/N was 1–2 at. % at discharge. For the fuel cycle evaluation, the activity of spent nuclear fuel and high-level waste at 100 and 100,000 years was lower for high-packing-fraction fuels than for conventional LWR fuel. Environmental impact metrics were similar overall, but higher on the front end of the fuel cycle and lower on the back end of the fuel cycle. Reactivity coefficients of higher-packing-fraction TRISO-based fuel were reasonable compared with those of conventional fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Development of a Generalized Riser Flow Regime Map Based Upon Higher Moment and Chaotic Statistics Using Electrical Capacitance Volume Tomography (ECVT)

Dynamic analyses have been applied to the temporal signals from an Electro Capacitance Volume Tomography instrument located near mid-height on the riser of an industrial-scale cold-flow circulating fluidized bed to characterize gas-solids flow behavior in the riser. Twelve capacitance electrodes surround the cylindrical riser over a height of 1.3 m. The instrument used a neural network deconvolution algorithm to determine the spatially resolved solids fraction recorded at 52 Hz. Experiments were carried out over a range of gas and solids flows in the transport regime using a Geldart Group B bed material, high density polyethylene with mean particle size of 880 μm. The radial solids distribution was found to vary from one-time step to the next between profiles typical of laminar and turbulent flow. The duration of time spent in each of these flow profiles depended upon the operating regime – dilute, core-annular, or fast fluidized bed. The chaotic structure of the temporal data was characterized using the three conventional approaches: the first 4 moments from the distribution of signal in time, system memory parameters from the autocorrelation function and the Hurst exponent, and analysis of the correlationentropy and correlation dimension of the attractor. These signal analysis techniques were used to clearly distinguish differences between different transport operating regimes. Specifically, it was experimentally observed that a riser transitions from core annular flow profile to dilute and dense regimes via increasing the frequency of short term transients to either dilute or dense flow profiles, respectively. A regime map was generated based upon these dynamics using solids flux and gas velocity axes. Fast fluidized, core annular, and dilute each exhibited different degree of dynamic characteristics typical of fluid dominated or particle compromising behavior. It should be noted that the magnitude for the different statistics was in the same range regardless of the regime, it was the radial profile for the statistic that changed and subsequently identified that there was a change in the regime. Finally, a reduced regime map was developed consisting of plotting the gas velocity normalized by the upper transport velocity versus the solids flux normalized by the saturation carrying capacity. The use of this reduced plot allowed the data from widely different conditions to be plotted and compared on the same<p>graph. Note that in many instances, some of the statistics identified the operating point as being in one regime while others indicated that it was in another indicating a transition region between dilute or core annular regimes and between the core annular and fast fluidization regimes. This now provides a tool that can be used to optimize process performance, identify changes in operating states, or replicate process dynamics during process scaling or changing operating parameters. </p>

Breault, Ronald↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Screening Ionic Liquids Based on Ionic Volume and Electrostatic Potential Analyses

Ionic liquids are known to have tunable solvation properties, based on the pairing of different anions and cations, but the compositional landscape is vast and challenging to navigate efficiently. Some computational screening protocols are available, but they can be either time-consuming or difficult to implement. Herein, we perform a detailed investigation of the fundamental role of electrostatic interactions in these systems. We effectively develop a bridge between the previous volume-based approach (VBA) with a quantum structure–property relationship (QSPR) approach to create fast, simple screening guidelines. We propose a new parameter that is applicable to both monovalent and multivalent ions, the ionic polarity index (IPI), which is defined as the ratio of the average electrostatic surface potential ($\bar{V}$) of the ion to the net charge of the ion (q). The IPI correlation has been tested on a diverse dataset of 121 ions and reliable predictions can be obtained within a homologous series of ionic liquid compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relation between the Hydrated Electron Solvation Structure and Its Partial Molar Volume

It is now generally accepted that the hydrated electron occupies a cavity in water, but the size of the cavity and the arrangements of the solvating water molecules are not fully characterized. Here, we use the Kirkwood-Buff (KB) approach to examine how the partial molar volume (V M ) provides insight into these issues. The KB method relates V M to an integral of the electron-water radial distribution function, a key measure of the hydrated electron structure. Here we have applied it to three widely-used pseudopotentials and the results show that V M is a sensitive measure of the fidelity of hydrated electron descriptions. Thus, the measured V M places constraints on the hydrated electron structure that are important in developing and evaluating model descriptions. Importantly, we find that V M does not reflect only the cavity size (and thus should not be used to infer the cavity radius), but is strongly dependent on the extended solvation structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Water Volume Fraction on Water Adsorption in Anion Exchange Membranes

Water absorption plays a key role in the performance of polymeric anion exchange membranes. It influences important properties such as ionic conductivity and mechanical strength and alters their performance as solid electrolytes in hydrogen electrochemical devices for energy conversion. However, computational approaches that address the relationship between the polymer design and the absorption process are scarce. In this work, we introduce a simple thermodynamic model to predict the water absorption isotherms of polyelectrolyte membranes in contact with a water vapor reservoir that incorporates the specific chemical design of the polymers. The model accurately predicts the water content and macrostructural properties of polynorbornene membranes as a function of the water activity and successfully captures the effect of various polymer design parameters. The energy of pairwise attractive interactions predicted by our model provides a means to interpret the absorption process at the molecular level. The model also reveals the most significant favorable and unfavorable contributions to the free energy and indicates that their balance is solely governed by the water volume fraction, regardless of the polymer design. This universal behavior leads to important implications in the search for better ion exchange membranes.

Zaldivar, Gervasio [New York University, Brooklyn,↗