Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Gaseous hydrogen storage system with cryogenic supply

A gaseous hydrogen storage and distribution system with a cryogenic supply and a method for the cryogenic conversion of liquid hydrogen into high-pressure gaseous hydrogen are provided. The gaseous hydrogen storage and distribution system includes pressuring liquid hydrogen from a cryogenic tank using a low pressure liquid pump before vaporization within a relatively small vaporizer. The resulting high pressure gaseous hydrogen is transferred to a plurality of storage tanks at ambient temperature according to a desired fill sequence. The high pressure hydrogen gas is subsequently distributed from the storage tanks through a hydrogen fueling dispenser according to a desired dispensing sequence. The present system and method provide improvements in operational safety, eliminates the use of high pressure gas compressor, and minimizes boiling off and ventilation losses at a reduced cost when compared to existing thermal compression storage systems.

Feng, Zhili↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY2022 Filter Test for TRU Waste Drum Prototype Unit

Continuing last year’s (fiscal year 2021) work, a prototype instrument and an NPI-6 Integrated Work Document (IWD) were developed to assess the functionality of filters on transuranic waste containers (commonly called 55 Gallon ring-top drums) without requiring the removal of the drum lid. The purpose of this work is to determine the air flow and pressure characteristics associated with filter clogging, filter pressure drop at a fixed flow rate, and leakage around the lid seal. The FY22 objectives included: (A) Development of prototype device, (B) Drafting an IWD document, (C) Defining a filter clogging parameter, (D) Assessing filter damage due to over-pressure events, and (E) A path forward to obtain approval of the system safety filters in compliance with P101-16 Industrial Ventilation – non HVACR (LANL 2022).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Analysis Approach for Large Data Volumes in a Connected Community

Recent advancements within smart neighborhoods where utilities are enabling automatic control of appliances such as heating, ventilation, and air conditioning (HVAC) and water heater (WH) systems are providing new opportunities to minimize energy costs through reduced peak load. This requires systematic collection, storage, management, and in-memory processing of large volumes of streaming data for fast performance. In this paper, we propose a multi-tier layered IoT software framework that enables effective descriptive and predictive data analysis for understanding live operation of the neighborhood, fault identification, and future opportunities for further optimization of load curves. We then demonstrate how we achieve live situational awareness of the connected neighborhood through a suite of visualization components. Finally, we discuss a few analytic dashboards that address questions such as peak load reductions obtained due to optimization, customer preference for automatic control of appliances (do they override the automatic control of HVAC?, etc.). 1 1 This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a nonexclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).

Chinthavali, Supriya↗

Smart indoor air venting system

A venting system in accordance with the present disclosure includes a ventilation fan and one or more sensors coupled to the ventilation fan. The ventilation fan is positioned to vent air from an indoor environment. The sensors are positioned to monitor conditions in the indoor environment and selectively operate the ventilation fan to condition air in the indoor environment.

Moore, Mike↗

Simple Wins: Driving Effective Implementation of Energy Efficiency Projects

Small- and medium-sized manufacturers (SMMs) in the United States, making up over 98% of manufacturing firms, account for 48.3% of the sector’s energy consumption. Despite access to energy assessments and technical resources, such as those from the US Department of Energy’s Better Plants program and Industrial Training and Assessment Centers, implementation rates for identified energy-saving measures remain lower than expectations, averaging 47%. Some barriers were identified by other researchers as limited workforce capacity, inadequate training, and time constraints hinder progress. This article studied the development of customized checklists together with the energy assessment report as a practical solution to improve implementation rates for energy efficiency projects among SMMs. The framework for the checklists was grounded in five principles: short, precise, actionable, relevant, and codeveloped (SPARC). A case study of a 500,000-squarefoot SMM demonstrates how tailored checklists targeting significant energy users—such as heating, ventilating and air conditioning (HVAC), lighting, and compressed air systems for this facility—can simplify the process for staff to do facility walkthroughs to monitor best practices and track the progress of energy efficiency project implementation.

Guo, Wei [Oak Ridge National Laboratory (ORNL), Oa↗

Final Seismic Shake Table Test Plan

The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test on the dry storage systems of spent nuclear fuel (SNF) to close the gap related to seismic loads on fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. Full-scale testing is needed because a dry storage system is a complex and highly nonlinear system making it hard to predict (model) the responses to seismic excitations. The non-linearity arises from the multiple spatial gaps in the system – between fuel rods and the basket, between the basket and dry storage canister, between the dry storage canister and the storage cask (overpack), and ventilation gaps. The non-linearities pose significant limitations on the value of tests with scaled systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Management of Grid-Interactive Efficient Buildings via Safe Reinforcement Learning

Reinforcement learning (RL)-based methods have achieved significant success in managing grid-interactive efficient buildings (GEBs). However, RL does not carry intrinsic guarantees of constraint satisfaction, which may lead to severe safety consequences. Besides, in GEB control applications, most existing safe RL approaches rely only on the regularisation parameters in neural networks or penalty of rewards, which often encounter challenges with parameter tuning and lead to catastrophic constraint violations. To provide enforced safety guarantees in controlling GEBs, this paper designs a physics-inspired safe RL method whose decision-making is enhanced through safe interaction with the environment. Different energy resources in GEBs are optimally managed to minimize energy costs and maximize customer comfort. The proposed approach can achieve strict constraint guarantees based on prior knowledge of a set of developed hard steady-state rules. Simulations on the optimal management of GEBs, including heating, ventilation, and air conditioning (HVAC), solar photovoltaics, and energy storage systems, demonstrate the effectiveness of the proposed approach.

Huo, Xiang↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous bi-products of research activities or airborne pathogens. As a result, building ventilation is the primary defense against unseen airborne hazards. Critical laboratory facilities already demand the need for effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently available contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers on a limited budget. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in the critical laboratory environment. In this session, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories without breaking the bank. This paper describes a low-cost solution for providing a safe, healthy building environment and reducing energy use through effective, efficient ventilation.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Neonatal respiratory support strategies—short and long-term respiratory outcomes

Mechanical ventilation (MV), although life-saving, is associated with chronic respiratory morbidity in both preterm and term born infants. New ventilation modes have been developed with the aim of minimising lung injury. These include invasive and non-invasive respiratory support strategies, techniques for less invasive surfactant administration (LISA) and closed-loop automated oxygen control (CLAC) systems. Increasingly, newborn infants with signs of respiratory distress are stabilised on continuous positive airway pressure (CPAP) and receive LISA. Early CPAP when compared to mechanical ventilation reduced the incidence of BPD and respiratory morbidity at 18 to 22 months corrected age. Nasal intermittent positive pressure ventilation reduced treatment failure rates compared to CPAP, but not bronchopulmonary dysplasia (BPD). LISA compared with intubation and surfactant delivery reduced BPD, but there is no evidence from randomised trials regarding long-term respiratory and neurodevelopmental outcomes. Synchronisation of positive pressure inflations with the infant's respiratory efforts used with volume targeting should be applied for infants requiring intubation as this strategy reduces BPD. A large RCT with long term follow up data demonstrated that prophylactic high frequency oscillatory ventilation (HFOV) improved respiratory and functional outcomes at school age, but those effects were not maintained after puberty. CLAC systems appear promising, but their effect on long term clinical outcomes has not yet been explored in randomised trials. Further studies are required to determine the role of newer ventilation modes such as neurally adjusted ventilator assist (NAVA). All such respiratory support strategies should be tested in randomised controlled trials powered to assess long-term outcomes.

Kaltsogianni, Ourania↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design.

42 ENGINEERING↗