Study of Thermodynamic Vent and Screen Baffle Integration for Orbital Storage and Transfer of Liquid Hydrogen

A comprehensive analytical and experimental program was performed to determine the feasibility of integrating an internal thermodynamic vent system and a full wall-screen liner for the orbital storage and transfer of liquid hydrogen (LH2). Ten screens were selected from a comprehensive screen survey. The experimental study determined the screen bubble point, flow-through pressure loss, and pressure loss along rectangular channels lined with screen on one side, for the 10 screens using LH2 saturated at 34.5 N/cm2 (50 psia). The correlated experimental data were used in an analysis to determine the optimum system characteristics in terms of minimum weight for 6 tanks ranging from 141.6 m3 (5,000 ft3) to 1.416 m3 (50 ft3) for orbital storage times of 30 and 300 days.

Cady, E. C.↗

Vented vectoring-nozzle for STOL and V/STOL aircraft

Vented vectoring-nozzle has superior thrust coefficient and is lighter in weight because it does not require completely enclosed elbow duct ordinarily used to deflect nozzle flow. Improved nozzle has primary nozzle and three-sided elbow deflector.

Esker, D. W.↗

Results of tests OA26 and IA16 in the NASA/ARC 3.5-foot hypersonic wind tunnel on an 0.015-scale model (36-OTS) of the space shuttle configuration 140A/B to obtain pressures for venting analysis

Tests were conducted, from November 15 to December 4, 1973, to obtain surface pressure data on an 0.015-scale replica of the Space Shuttle Vehicle 4. Data were obtained at Mach numbers of 5.3, 7.4, and 10.3, to support the venting analysis for both launch and entry conditions. These tests were the final tests in a series covering a Mach number range from 0.6 to 10.3. The model was instrumented with pressure orifices in the vicinity of the cargo bay door hinge and parting lines, and on the side of the fuselage at the crew compartment, and below the orbital maneuvering system pods at the aft compartment. The model was tested at angles of attack and sideslip consistent with expected divergencies from the nominal trajectory.

Spangler, R. H.↗

Space LOX vent system

This is the final report summarizing the work completed under contract NAS8-26972. Concept selection, design, fabricating and testing of a prototype compact heat exchanger thermodynamic vent system are discussed. The system is designed to operate in a 2.7m (9 foot) spherical liquid oxygen tank with a heating rate of 32.2 - 35.2 watts (110-120 Btu/hr) and to control pressure to 310 + or - 13.8 kN/sq m (45 + or - 2.0 psia.) the design mission is of 2,590 ks (30 days) duration on board a space shuttle orbiter.

Erickson, R. C.↗

Computer controlled vent and pressurization system

The Centaur space launch vehicle airborne computer, which was primarily used to perform guidance, navigation, and sequencing tasks, was further used to monitor and control inflight pressurization and venting of the cryogenic propellant tanks. Computer software flexibility also provided a failure detection and correction capability necessary to adopt and operate redundant hardware techniques and enhance the overall vehicle reliability.

Cieslewicz, E. J.↗

Computer controlled vent and pressurization system

The paper illustrates how the Centaur space launch vehicle airborne computer, which was primarily used to perform guidance, navigation, and sequencing tasks, was further used to monitor and control inflight pressurization and venting of the cryogenic propellant tanks. Computer software flexibility also provided a failure detection and correction capability necessary to adopt and operate redundant hardware techniques and enhance the overall vehicle reliability.

Cieslewicz, E. J.↗

Low pressure radon diffusion - A laboratory study and its implications for lunar venting

Results of a study of radon migration through columns of fine particulate materials, at total pressures of 0.02-0.2 torr, are reported. Materials studied were: NBS Glass Spheres (SRM 1003), Emerson & Cuming Eccospheres (IG-101), activated coconut charcoal, Lipaci obsidian, and W-1 Standard Diabase. Rates of diffusion were used to derive heats of adsorption for radon on the materials tested. The most reliable values found clustered around 8-9 kcal/mole. These high heats of adsorption, if typical for most materials, combined with low percentages of radon emanation by lunar soils found by other researchers, imply that random walk diffusion will not be an important mechanism for redistributing the radon and the radon daughters produced in the lunar regolith. In particular, since random walk migration is not a sufficient mechanism to account for localized high concentrations of radon-222 and its daughter polonium-210 observed by the Apollo 15 and 16 command modules, an alternative mechanism is proposed, in which radon would be swept to the surface by other gases during intermittent venting events.

Friesen, L. J.↗

Multiple-compartment venting

Program simulates venting characteristics of multireservoir multiconductor configurations. Reservoirs may be finite or infinite volume.

Donehoo, L. K.↗

Analysis and testing of two-dimensional vented Coanda ejectors with asymmetric variable area mixing sections

The analysis of asymmetric, curved (Coanda) ejector flow has been completed using a finite difference technique and a quasi-orthogonal streamline coordinate system. The boundary layer type jet mixing analysis accounts for the effect of streamline curvature in pressure gradients normal to the streamlines and on eddy viscosities. The analysis assured perfect gases, free of pressure discontinuities and flow separation and treated three compound flows of supersonic and subsonic streams. Flow parameters and ejector performance were measured in a vented Coanda flow geometry for the verification of the computer analysis. A primary converging nozzle with a discharge geometry of 0.003175 m x 0.2032 m was supplied with 0.283 cu m/sec of air at about 241.3 KPa absolute stagnation pressure and 82 C stagnation temperature. One mixing section geometry was used with a 0.127 m constant radius Coanda surface. Eight tests were run at spacing between the Coanda surface and primary nozzle 0.01915 m and 0.318 m and at three angles of Coanda turning: 22.5 deg, 45.0 deg, and 75.0 deg. The wall static pressures, the loci of maximum stagnation pressures, and the stagnation pressure profiles agree well between analytical and experimental results.

Maroti, L. A.↗

Safe venting for electronic components

Vented enclosure is made from lightweight metal. Printed-circuit boards are attached to bottom and end bulkheads and to top cover. Airflow cools components indirectly through walls of inner compartment. Flammability and smoke tests demonstrate safety of enclosure.

Currin, R., Jr.↗

Flashback flame arrester devices for fuel cargo tank vapor vents

The flame quenching capability of four types of flame arresting devices suitable for installation on fuel cargo tank vents of marine transport vessels is evaluated. A single 30 mesh screen, a dual 20 mesh screen, a spiral wound crimped metal ribbon, and a packed bed of ballast rings were tested. Flame speed and flame penetration of the test arresters were determined. Eight fuels representative of bulk cargoes were tested. The test arresters quenched a minimum of three flashback flames from all eight fuels, with one exception: high speed ethylene flames penetrated the dual 20 mesh screen on three tests. The arresters withstood the sustained flame from a propane/air mixture for 30 minutes. None of the arresters withstood the sustained flame from an ethylene/air mixture for more than 7 minutes.

Bjorklund, R. A.↗

Tests of a D vented thrust deflecting nozzle behind a simulated turbofan engine

A D vented thrust deflecting nozzle applicable to subsonic V/STOL aircraft was tested behind a simulated turbofan engine in the verticle thrust stand. Nozzle thrust, fan operating characteristics, nozzle entrance conditions, and static pressures were measured. Nozzle performance was measured for variations in exit area and thrust deflection angle. Six core nozzle configurations, the effect of core exit axial location, mismatched core and fan stream nozzle pressure ratios, and yaw vane presence were evaluated. Core nozzle configuration affected performance at normal and engine out operating conditions. Highest vectored nozzle performance resulted for a given exit area when core and fan stream pressure were equal. Its is concluded that high nozzle performance can be maintained at both normal and engine out conditions through control of the nozzle entrance Mach number with a variable exit area.

Watson, T. L.↗

Vented compression molding

A new process, vented compression molding, is developed for molding low density particulates, such as ablative materials used in the Space Shuttle. This process is a modification of standard compression molding that uses a perforated surface as the molding surface. An excess of material is used to fill the mold cavity and this material is forced through the openings in the surface of the mold as the mold closes. This process creates frictional forces, which can be determined approximately by Mohr-Coulomb yield criterion, generating the pressure that compacts the material. The pressure in the mold is shown to be governed by the geometry of the openings and the mechanical properties of the particulate, and not by the displacement or the volume of the mold. It is determined that this uncoupling of the pressure-displacement relationship allows uniform material distribution and compaction without requiring large-scale flow of the particulates.

Mccree, J. O.↗

First estimate of annual mercury flux at the Kilauea main vent

Mercury and sulphur dioxide analyses were conducted from 1971 to 1980 on air samples collected immediately downwind of Halemaumau, the Kilauea main vent, in Hawaii. On the basis of these measurements, an Hg/SO2 ratio of 0.00051 has been derived which, when applied to the recently determined SO2 mass output of Halemaumau, yields a calculated Hg flux of 2.6 x 10 to the 8th g annually. This rate is consistent with Varekamp and Busek's (1981) evidence suggesting that volcanogenic Hg significantly contributes to the atmospheric total.

Siegel, S. M.↗

Sparger system for MMH-helium vents

Based on a calculated vent flow rate and MMH concentration, a TI-59 program was run to determine total sparger hole area for a given sparger inlet pressure. Hole diameter is determined from a mass transfer analysis in the holding tank to achieve complete capture of MMH. In addition, based on oxidation kinetics and vapor pressure data, MMh atmospheric concentrations are determined 2 ft above the holding tank.

Rakow, A.↗

Efficient Vent Unloading of Air Compressors

Method for unloading one-and two-stage reciprocating air compressors increases energy efficiency and inhibits deterioration of components. In new unloader configuration, compressor vented to atmosphere on downstream side. Method implemented expeditiously as modification of existing systems.