Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VEIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Shergottite Impact Melt Glasses Contain Soil from Martian Uplands

Martian meteorite (shergottite) impact melt glasses that contain high concentrations of martian atmospheric noble gases and show significant variations in Sr-87/Sr-86 isotopic ratios are likely to contain Martian surface fines mixed with coarser regolith materials. The mixed soil constituents were molten due to shock at the time of meteoroid impact near the Martian surface and the molten glass got incorporated into the voids and cracks in some shergottite meteorites. Earlier, Rao et al. found large enrichments of sulfur (sulfate) during an electron-microprobe study of several impact melt glass veins and pods in EET79001,LithC thin sections. As sulfur is very abundant in Martian soil, these S excesses were attributed to the mixing of a soil component containing aqueously altered secondary minerals with the LithC precursor materials prior to impact melt generation. Recently, we studied additional impact melt glasses in two basaltic shergottites, Zagami and Shergotty using procedures similar to those described by Rao et al. Significant S enrichments in Zagami and Shergotty impact melt glass veins similar to the EET79001, LithC glasses were found. In addition, we noticed the depletion of the mafic component accompanied by the enrichment of felsic component in these impact melt glass veins relative to the bulk host rock in the shergottites. To explain these observations, we present a model based on comminution of basaltic rocks due to meteroid bombardment on martian regolith and mechanical fractionation leading to enrichment of felsics and depletion of mafics in the fine grained dust which is locally mobilized as a result of saltation and deflation due to the pervasive aeolian activity on Mars.

Rao, M. N.↗

Shergottite Impact Melt Glasses Contain Soil from Martian Uplands

Martian meteorite (shergottite) impact melt glasses that contain high concentrations of martian atmospheric noble gases and show significant variations in Sr-87/Sr-86 isotopic ratios are likely to contain Martian surface fines mixed with coarser regolith materials. The mixed soil constituents were molten due to shock at the time of meteoroid impact near the Martian surface and the molten glass got incorporated into the voids and cracks in some shergottite meteorites. Earlier, Rao et al. found large enrichments of sulfur (sulfate) during an electron-microprobe study of several impact melt glass veins and pods in EET79001,LithC thin sections. As sulfur is very abundant in Martian soil, these S excesses were attributed to the mixing of a soil component containing aqueously altered secondary minerals with the LithC precursor materials prior to impact melt generation. Recently, we studied additional impact melt glasses in two basaltic shergottites, Zagami and Shergotty using procedures similar to those described. Significant S enrichments in Zagami and Shergotty impact melt glass veins similar to the EET79001, LithC glasses were found. In addition, we noticed the depletion of the mafic component accompanied by the enrichment of felsic component in these impact melt glass veins relative to the bulk host rock in the shergottites. To explain these observations, we present a model based on comminution of basaltic rocks due to meteoroid bombardment on martian regolith and mechanical fractionation leading to enrichment of felsics and depletion of mafics in the fine grained dust which is locally mobilized as a result of saltation and deflation due to the pervasive aeolian activity on Mars.

Rao, M. N.↗

Effects of guar gum and cellulose on glucose absorption, hormonal release and hepatic metabolism in the pig

Six Large White pigs (mean body-weight 59 (SE 1.7) kg) were surgically fitted with permanent catheters in the portal vein, the brachiocephalic artery and the right hepatic vein, as well as with electromagnetic flow probes around the portal vein and the hepatic artery, and allowed to recover. The non-anaesthetized animals were given a basal non-fibre diet (diet A) alone or together with 60 g guar gum/kg (diet B) or 150 g purified cellulose/kg (diet C) by substitution for mica. The diets were given for weekly periods and according to a replicated 3 x 3 Latin square design. On the last day of each such adaptation period, test meals of 800 g were given before blood sampling. Sampling was continued for 8 h. Guar gum strongly reduced glucose apparent absorption without changing the absorption and the hepatic uptake profiles. Production rates of insulin, gastric inhibitory polypeptide and insulin-like growth factor-1 (IGF-1) were lowest after guar gum ingestion. However, the reductions in peripheral blood insulin levels caused by guar gum were not associated with a change in hepatic insulin extraction. IGF-1 appeared to be strongly secreted by the gut, whereas the liver had a net uptake of the peptide. Ingestion of guar gum increased the hepatic extraction coefficient of gut-produced IGF-1. Guar gum ingestion appeared also to decrease glucagon secretion. Cellulose at the level consumed had very few effects on the variables considered. It is suggested that the modulation of intestinal mechanisms by guar gum was sufficient to mediate the metabolic effects described.

Cellulose/administration & dosage↗

Glucose absorption, hormonal release and hepatic metabolism after guar gum ingestion

Six non-anaesthetized Large White pigs (mean body weight 59 +/- 1.7 kg) were fitted with permanent catheters in the portal vein, the brachiocephalic artery and the right hepatic vein and with electromagnetic flow probes around the portal vein and the hepatic artery. The animals were provided a basal none-fibre diet (diet A) alone or together with 6% guar gum (diet B) or 15% purified cellulose (diet C). The diets were given for 1 week and according to a replicated 3 x 3 latin-square design. On the last day of each adaptation period test meals of 800 g were given prior to blood sampling. The sampling was continued for 8 h. Guar gum strongly reduced the glucose absorption as well as the insulin, gastric inhibitory polypeptide (GIP) and insulin-like growth factor-1 (IGF-1) production. However, the reduction in peripheral blood insulin levels caused by guar gum was not associated with a change in hepatic insulin extraction. IGF-1 appeared to be strongly produced by the gut. The liver had a net uptake of the peptide. Ingestion of guar gum increased the hepatic extraction coefficient of gut produced IGF-1. Guar gum ingestion also appeared to decrease pancreatic glucagon secretion. Cellulose at the level consumed had very little effect on the parameters considered. It is suggested that the modulation of intestinal mechanisms by guar gum was sufficient to mediate the latter internal metabolic effects.

Glucose/metabolism↗

Cardiovascular tissues contain independent circadian clocks

Acute cardiovascular events exhibit a circadian rhythm in the frequency of occurrence. The mechanisms underlying these phenomena are not yet fully understood, but they may be due to rhythmicity inherent in the cardiovascular system. We have begun to characterize rhythmicity of the clock gene mPer1 in the rat cardiovascular system. Luciferase activity driven by the mPer1 gene promoter is rhythmic in vitro in heart tissue explants and a wide variety of veins and arteries cultured from the transgenic Per1-luc rat. The tissues showed between 3 and 12 circadian cycles of gene expression in vitro before damping. Whereas peak per1-driven bioluminescence consistently occurred during the late night in the heart and all arteries sampled, the phases of the rhythms in veins varied significantly by anatomical location. Varying the time of the culture procedure relative to the donor animal's light:dark cycle revealed that, unlike some other rat tissues such as liver, the phases of in vitro rhythms of arteries, veins, and heart explants were affected by culture time. However, phase relationships among tissues were consistent across culture times; this suggests diversity in circadian regulation among components of the cardiovascular system.

Non-NASA Center↗

Chromite-Plagioclase Assemblages as a New Shock Indicator; Implications for the Shock and Thermal Histories of Ordinary Chondrites

Chromite in ordinary chondrites (OC) can be used as a shock indicator. A survey of 76 equilibrated H, L and LL chondrites shows that unshocked chromite grains occur in equant, subhedral and rounded morphologies surrounded by silicate or intergrown with metallic Fe-Ni and/or troilite. Some unmelted chromite grains are fractured or crushed during whole-rock brecciation. Others are transected by opaque veins; the veins form when impacts cause localized heating of metal-troilite intergrowths above the Fe-FeS eutectic (988 C), mobilization of metal-troilite melts, and penetration of the melt into fractures in chromite grains. Chromite-plagioclase assemblages occur in nearly every shock-stage S3-S6 OC; the assemblages range in size from 20-300 microns and consist of 0.2-20-micron-size euhedral, subhedral, anhedral and rounded chromite grains surrounded by plagioclase or glass of plagioclase composition. Plagioclase has a low impedance to shock compression. Heat from shock-melted plagioclase caused adjacent chromite grains to melt; chromite grains crystallized from this melt. Those chromite grains in the assemblages that are completely surrounded by plagioclase are generally richer in Al2O3, than unmelted, matrix chromite grains in the same meteorite. Chromite veinlets (typically 0.5-2 microns thick and 10-300 microns long) occur typically in the vicinity of chromite-plagioclase assemblages. The veinlets formed from chromite-plagioclase melts that were injected into fractures in neighboring silicate grains; chromite crystallized in the fractures and the residual plagioclase-rich melt continued to flow, eventually pooling to form plagioclase-rich melt pockets. Chromite-rich chondrules (consisting mainly of olivine, plagioclase-normative mesostasis, and 5-15 vol.% chromite) occur in many shocked OC and OC regolith breccias but they are absent from primitive type-3 OC. They may have formed by impact melting chromite, plagioclase and adjacent mafic silicates during higher-energy shock events. The melt was jetted from the impact site and formed droplets due to surface tension. Crystallization of these droplets may have commenced in flight, prior to landing on the parent-body surface. Chromite-plagioclase assemblages and chromite veinlets occur in 25 out of 25 shock-stage S1 OC of petrologic type 5 and 6 that I examined. Although these rocks contain unstrained olivine with sharp optical extinction, most possess other shock indicators such as extensive silicate darkening, numerous occurrences of metallic Cu, polycrystalline troilite, and opaque veins. It seems likely that these rocks were shocked to levels at least as high as shock-stage S3 and then annealed by heat generated during the shock event. During annealing, the olivine crystal lattices healed but other shock indicators survived. Published Ar-Ar age data for some SI OC indicate that many shock and annealing events occurred very early in the history of the parent asteroids. The common occurrence of shocked and annealed OC is consistent with collisions being a major mechanism responsible for metamorphosing OC.

Rubin, Alan E.↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and Braslet-M Occlusion Cuffs

The objective of this joint U.S. - Russian project was the development and validation of an in-flight methodology to assess a number of cardiac and vascular parameters associated with circulating volume and its manipulation in long-duration space flight. Responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound (US) before, during, and after temporary volume reduction by means of Braslet-M thigh occlusion cuffs (Russia). Materials and Methods: The study protocol was conducted in 14 sessions on 9 ISS crewmembers, with an average exposure to microgravity of 122 days. Baseline cardiovascular measurements were taken by echocardiography in multiple modes (including tissue Doppler of both ventricles) and femoral and jugular vein imaging on the International Space Station (ISS). The Braslet devices were then applied and measurements were repeated after >10 minutes. The cuffs were then released and the hemodynamic recovery process was monitored. Modified Valsalva and Mueller maneuvers were used throughout the protocol. All US data were acquired by the HDI-5000 ultrasound system aboard the ISS (ATL/Philips, USA) during remotely guided sessions. The study protocol, including the use of Braslet-M for this purpose, was approved by the ISS Human Research Multilateral Review Board (HRMRB). Results: The effects of fluid sequestration on a number of echocardiographic and vascular parameters were readily detectable by in-flight US, as were responses to respiratory maneuvers. The overall volume status assessment methodology appears to be valid and practical, with a decrease in left heart lateral E (tissue Doppler) as one of the most reliable measures. Increase in the femoral vein cross-sectional areas was consistently observed with Braslet application. Other significant differences and trends within the extensive cardiovascular data were also observed. (Decreased - RV and LV preload indices, Cardiac Output, LV E all maneuvers, LV Stroke Volume). Conclusions: This Study: 1) Addressed specific aspects of operational space medicine and space physiology, including assessment of circulating volume disturbances 2) Expanded the applications of diagnostic ultrasound imaging and Doppler techniques in microgravity. 3) Used respiratory maneuvers against the background of acute circulating volume manipulations which appear to enhance our ability to noninvasively detect volume-dependency in a number of cardiac and vascular parameters. 4) Determined that Tei index is not clinically changed therefore contractility not altered in the face of reduced preload. 5) Determined that increased Femoral Vein Area indicating blood being sequestered in lower extremities correlates with reduced preload and cardiac output. 6) That Braslet may be the only feasible means of acutely treating high pressure pulmonary edema in reduced gravity environments.

Hamilton, Douglas↗

Diagenetic Features in Yellowknife Bay, Gale Crater, Mars: Implications for Substrate Rheology and Potential Gas Release

Multiple diagenetic features have been observed in clay­-bearing mudstone exposed within Yellowknife Bay, Gale Crater, Mars. These features occurred during at least two separate episodes: an early generation of spheroidal concretions that co-­occur with a dense networks of mineralized fractures, and a later generation of mineralized veins. Concretions consist of mm-sized spheroids (0.4 to 8.0 mm, mean diameter of 1.2 mm) that are distinctly more resistant than the encompassing mudstone. Dissected spheroids suggest an origin via compaction and incipient lithification of the substrate at the perimeter of syndepositional void space. Concretions are generally patchy in their distribution within clay-‐bearing mudstone, but in places can be the dominant fabric element. Locally dense networks of mineralized fractures occur in regions of low concretion abundance. These consist of short (< 50 cm), curvilinear to planar mineralized voids that occur across a range of orientations from vertical to subhorizontal. Fractures are filled by multi-phase cement consisting of two isopachous, erosionally resistant outer bands, and a central less resistant fill. Physical relationships suggests that original fractures may have formed as both interconnected voids and as discrete cross--cutting features. Co--occurrence of early diagenetic concretions and fracture networks suggests a common origin via gas release within a subaqueous, shallow substrate. We suggest that gas release within weakly cohesive subsurface sediments resulted in substrate dewatering and an increase in the cohesive strength of the substrate. Local differences in substrate strength and rate of gas production would have result in formation of either discrete voids or fracture networks. A second generation of mineralized veins is characterized by a regionally low spatial density, predominantly vertical or horizontal orientations, and a single phase of Ca-‐sulfate mineral fill. These veins cross-cut the early diagenetic elements and intersect a greater thickness of stratigraphy within Yellowknife Bay, suggesting a later-‐diagenetic origin via hydraulic fracturing.

Kah, L. C.↗

Analysis of Retinal Vascular Branching in Human Subjects Undergoing 70-Day Head-Down Tilt by NASAs VESGEN Software

Significant risks for visual impairment were discovered recently in astronauts following spaceflight, especially after long-duration missions. We hypothesize that microgravity-induced fluid shifts result in pathological changes within the retinal vasculature that precede visual and other ocular impairments. We therefore are analyzing retinal vessels in healthy subjects before and after head-down tilt (HDT), a ground-based microgravity analog with NASA's VESsel GENeration Analysis (VESGEN) software. Methods. Spectralis® infrared (IR) fundus images were collected from both eyes of 6 subjects before and after 70 days of bed rest at 6 degree HDT (NASA Campaign 11). For our retrospective study, branching patterns in arterial and venous trees are mapped by VESGEN into vessel branching generations (Gx) that are quantified by parameters such as densities of vessel length (Lv), area (Av), number (Nv) and fractal dimension (Df) as described previously for diabetic retinopathy (IOVS 51(1):498). Results are further assigned by VESGEN into groups of large (G1-3), medium (G4-6) and small (G≥7) vessels. Results. All subjects remained asymptomatic throughout duration of HDT. To date, we have analyzed one IR image from each of the 12 eyes. Interestingly, two groups of the masked study population identified by VESGEN are distinguished by the presence or absence of small veins (G≥7). For example, L≥7 and Av≥7 are 2.7+/-1.3 E-4 px/px2 and 7.2+/-3.6 E-4 px2/px2 in 6 retinas, but 0 in the other 6 retinas. Nonetheless, the space-filling properties of the entire venous trees were remarkably uniform by all parameters, such as Df = 1.56+/-0.02 for 6 retinas with G≥7 and 1.55+/-0.02 for retinas without G≥7. No small arteries (G≥7) were detected. Conclusions. For our preliminary masked analysis, two groups of venous trees with and without small veins (G≥7) were clearly revealed by VESGEN. Upon completing all images and unmasking the subject status of before and after HDT, we will determine whether differences in the presence or absence of small veins are important correlates, and perhaps reliable predictors, of other ocular and physiological adaptations to prolonged head-down tilt and microgravity. Clinical methods for examining adaptive microvascular remodeling in the retina to microgravity space flight are not currently established.

Fractal↗

Association Between Vascular Density and Loss of Protective RAS During Early NPDR by Fractal Dimension

Purpose: Our hypothesis predicts that blood vessels within the retina increase in density during early-stage nonproliferative diabetic retinopathy (NPDR), based on previous results of a small retrospective study. For the current prospective study, the remodeling of arteries and veins during progression of early NPDR is assessed by a repertoire of parameters that includes the fractal dimension (D(sub f) ). In complex structures such as branching vascular trees, D(sub f) is a sensitive measure of space-filing capacity. The renin-angiotensin system (RAS) is implicated in DR pathogenesis and the function of circulating angiogenic cells (CACs), a critical bone marrow-derived population instrumental in vascular repair. Methods: Arterial and venous branching patterns were extracted from images of 6 normal controls and 3 early NPDR subjects (2 moderate, 1 mild) acquired by Heidelberg Spectralis (Registered Trademark) OCT following fluorescein angiography (FA). The vascular branching patterns were analyzed by NASAs VESsel GENeration Analysis (VESGEN) software, in which skeletonized representations were generated automatically to yield D(sub f) by the box-counting method. For binary 2D images, D(sub f) varies between limiting Euclidean dimensions of 1 and 2. Peripheral blood of diabetics and controls was collected for CD34+ CAC isolation. The gene expression of RAS in CACs was assessed by qPCR for Mas receptor to Ang-(1-7). The vasoreparative function of the CACs was measured by migration ability toward CXCL12 (SDF-1). Results: By D(sub f), venous and arterial densities were 1.370 +/- 0.006 and 1.329 +/- 0.016 for early NPDR, compared to 1.318 +/- 0.012 and 1.320 +/- 0.036 for control. The space filling capacity in early NPDR measured by D(sub f), a sensitive parameter, therefore demonstrated a pronounced increase for veins, but not for arteries. Mas receptor mRNA in CACs was increased in diabetics without DR but reduced with onset of NPDR, indicating possible loss of compensation of protective RAS during early DR. Migratory dysfunction of CD34+ cells was further associated with DR. Conclusions: As assessed by the fractal dimension in our preliminary study, the space-filling capacity of veins, but not arteries, was greater in early NPDR than in control. Larger patient populations will be examined as we complete our ongoing longitudinal study. Results further suggest the protective RAS axis within diabetic CACs is lost early in DR and is associated with increased vascular remodeling as evidenced by VESGEN analysis.

vascular↗

Importance of Sulfur for Phosphorus Mobility on the Martian Surface

Sulfur and phosphorus were mobile on the martian surface, and we present evidence that sulfate was likely a control on phosphate mobility. Mobility of the two elements on the martian surface is crucial for the habitability of Mars because their availability for biochemical reactions and biological structures is a major constraint on life. In the sedimentary rocks of Gale crater, the rover Curiosity has discovered evidence of mobile S and P with the alpha particle X-ray spectrometer (APXS). Sulfur-rich fluids are evident in ubiquitous Ca-sulfate veins that crosscut the bedrock. Compelling evidence of P mobility is in nodules, veins, crusts, and haloes with P2O5 enrichments (1.5-7.5 wt%) relative to the median bedrock (0.9-1.2 wt%) and average basaltic crust (~0.9 wt%). We have investigated phosphorus mobility in Hawaiian analogues, where the primary P2O5 (0.2-2.1 wt%) is contained in Ca-apatite. Four relevant processes have emerged: (1) In open-system, circumneutral regolith weathering profiles, we found up to 40% of the P was leached over 10s-100s ka. (2) Natural acid-sulfate alteration at the Maunakea summit resulted in the dissolution of apatite and mobilization of phosphate 10s-1000s µm to rock surfaces where it formed Al-phosphates and substituted into crystalline sulfates (alunite and jarosite). (3) Experimental results indicate that basaltic sediment chemisorbs phosphate (pH < 7). (4) In experimental systems containing water, basaltic sediment, and a starting pH = 2-7, phosphate has higher solubility in chloride-rich fluids, but significantly lower solubility in sulfate-rich fluids. For example, in water doped with phosphate (~100-500 mg/L), ~60-80% of the PO43- was removed from the sulfate-rich fluid, whereas ~20% of the PO43- was removed from the Cl-rich and pure water fluids (likely via adsorption). Gypsum precipitated from the sulfate-rich fluids; the fate of phosphate in the solid residue is unconfirmed. The potential for phosphate incorporation in martian sulfates is reflected in the enrichment of P2O5 in Gale Ca-sulfate veins, based on preliminary analyses of APXS data. Models for the mobility of phosphorus in Gale crater should consider these conflicting P characteristics: (1) P solubility may have been inhibited by sulfate and (2) P¬ is enriched in diagenetic features and was therefore mobile.

Jeff A. Berger↗

Enhancement of the visibility of objects located below the surface of a scattering medium

Techniques are provided for enhancing the visibility of objects located below the surface of a scattering medium such as tissue, water and smoke. Examples of such an object include a vein located below the skin, a mine located below the surface of the sea and a human in a location covered by smoke. The enhancement of the image contrast of a subsurface structure is based on the utilization of structured illumination. In the specific application of this invention to image the veins in the arm or other part of the body, the issue of how to control the intensity of the image of a metal object (such as a needle) that must be inserted into the vein is also addressed.

47 OTHER INSTRUMENTATION↗

Zinc distribution and speciation in Arabidopsis halleri x Arabidops is lyrata progenies presenting various zinc accumulation capacities

- The purpose of this study was to investigate the relationship between the chemical form and localization of zinc (Zn) in plant leaves and their Zn accumulationcapacity. - An interspecific cross between Arabidopsis halleri sp. halleri and Arabidopsis lyrata sp. petrea segregating for Zn accumulation was used. Zinc (Zn) speciation and Zn distribution in the leaves of the parent plants and of selected F1 and F2 progenies were investigated by spectroscopic and microscopic techniques and chemical analyses. - A correlation was observed between the proportion of Zn being in octahedral coordination complexed to organic acids and free in solution (Zn?OAs + Znaq) and Zn content in the leaves. This pool varied between 40percent and 80percent of total leaf Zn depending on the plant studied. Elemental mapping of the leaves revealed different Zn partitioning between the veins and the leaf tissue. The vein : tissue fluorescence ratio was negatively correlated with Zn accumulation. - The higher proportion of Zn?OAs + Znaq and the depletion of the veins in the stronger accumulators are attributed to a higher xylem unloading and vacuolar sequestration in the leaf cells. Elemental distributions in the trichomes were also investigated, and results support the role of carboxyl and⁄ or hydroxyl groups as major Zn ligands in these cells.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating the frequency and severity of ovarian venous congestion on adult computed tomography

Purpose: While pelvic congestion syndrome and chronic pelvic pain are relatively common in women, no large- or medium-sized studies have been conducted to our knowledge to evaluate the frequency and severity of ovarian vein dilatation (OVD) on computed tomography (CT). The purpose of our study was therefore to analyze a large number of consecutive abdominal and pelvic CT scans in adult women to determine OVD frequency and severity. Methods: An IRB-approved, single-institution retrospective analysis of 1042 consecutive abdominal and pelvic CT scans in women ages 25–65 was performed. Scans were evaluated for the presence and severity of OVD and association with “nutcracker anatomy.” A gradation scheme was developed based on quartile analysis. Results: 143 of the CT scans had OVD (13.7%). Of the positive scans, 96 were bilateral, 29 were left-side only, 18 were right-side only, and 18 had nutcracker-type compression of the left renal vein (14.4% of scans with left or bilateral OVD). In positive scans, the mean and median left OVD were 7.5 and 7 mm, respectively, and right-side were 7.2 and 7 mm, respectively. Based on quartile analysis, OVD grading was mild (< 6 mm), moderate (6–8 mm), or severe (> 8 mm), with moderate including the middle 50% of patients. Conclusions: OVD was found on 13.7% of 1042 consecutive female abdominal and pelvic CT scans, with “nutcracker anatomy” present in 14.4% of the scans with left OVD. Moderate dilatation was defined as an OVD of 6–8 mm at the iliac crests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Purpose: To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. Materials and methods: The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded. Results: The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively). Conclusion: The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT and MRI features of undifferentiated carcinomas with osteoclast-like giant cells of the pancreas: a case series

Purpose: The purpose of this case series was to describe computed tomography (CT) and magnetic resonance imaging (MRI) features of undifferentiated carcinoma with osteoclast-like giant cells of the pancreas. Methods: Institutional ethics review board approval was obtained, and informed consent was waived for this case series. We reviewed CT and MRI of patients with pathologically confirmed undifferentiated carcinoma with osteoclast-like giant cells of the pancreas found in the medical records of our hospital between 2006 and 2016. Results: Seven patients (3 males and 4 females; age, 59–82 years (mean, 71)) with confirmation by surgical resection (n = 3) or biopsy (n = 4) were identified. They underwent CT (n = 7) and MRI (n = 6). The tumors 26–83 mm in diameter (mean, 44 mm) were located in the head (n = 4) or body (n = 3) of the pancreas. They were demonstrated as lower attenuation areas relative to the adjacent pancreas on CT images obtained in both pancreatic and portal vein phases (n = 7) with a well-defined smooth margin (n = 5). They were demonstrated as hypointense areas relative to the pancreas on T2-weighted images (n = 4) and T2*-weighted images (n = 4) and diffusion-weighted images (n = 3). They contained hemosiderin deposits on histology (n = 7). Conclusions: Undifferentiated carcinoma with osteoclast-like giant cells of the pancreas might be present as low attenuation areas with a well-defined smooth margin on CT images obtained in pancreatic and portal vein phases, and hypointense areas on T2-, T2*-, and diffusion-weighted images caused by hemosiderin deposits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization with the Amplatzer Vascular Plug in TIPS Patients

Vessel embolization can be a valuable adjunct procedure in transjugular intrahepatic portosystemic shunt (TIPS). During the creation of a TIPS, embolization of portal vein collaterals supplying esophageal varices may lower the risk of secondary rebleeding. And after creation of a TIPS, closure of the TIPS itself may be indicated if the resulting hepatic encephalopathy severely impairs mental functioning. The Amplatzer Vascular Plug (AVP; AGA Medical, Golden Valley, MN) is well suited for embolization of large-diameter vessels and has been employed in a variety of vascular lesions including congenital arteriovenous shunts. Here we describe the use of the AVP in the context of TIPS to embolize portal vein collaterals (n = 8) or to occlude the TIPS (n = 2)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Thrombin Injection of a Femoral Artery Pseudoaneurysm with Simultaneous Venous Balloon Occlusion of a Communicating Arteriovenous Fistula

An 82-year-old woman developed acute occlusion of her right coronary artery. She underwent percutaneous coronary stent placement and aortic balloon pump installation. In the postprocedural period, she developed a common femoral artery pseudoaneurysm (PSA) that communicated with the common femoral vein via an arteriovenous fistula (AVF). After unsuccessful ultrasound-guided compression, ultrasound-guided thrombin injection of the PSA was performed, with simultaneous balloon occlusion of the common femoral vein at the level of the AVF. There was complete thrombosis of the PSA and AVF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗