Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VASCULAR DISEASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Crossing Ureteric Strictures: Microcatheters to the Rescue When Conventional Methods Fail

Tight distal ureteric strictures can be most challenging to traverse both from above, by interventional radiologists, and below, by urologists. Despite the advent of numerous guidewires, manufactured from different materials, often ureteric strictures are too tight to allow conventional guidewires to pass through. We describe an alternative approach to cross tight ureteric strictures, using a microguidewire and microcatheter combination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Saphenous Venous Ablation with Hot Contrast in a Canine Model

Purpose. To determine the feasibility, efficacy, and safety of thermal ablation of the saphenous vein with hot contrast medium. Methods. Twelve saphenous veins of 6 dogs were percutaneously ablated with hot contrast medium. In all animals, ablation was performed in the vein of one leg, followed by ablation in the contralateral side 1 month later. An occlusion balloon catheter was placed in the infragenicular segment of the saphenous vein via a jugular access to prevent unwanted thermal effects on the non-target segment of the saphenous vein. After inflation of the balloon, 10 ml of hot contrast medium was injected under fluoroscopic control through a sheath placed in the saphenous vein above the ankle. A second 10 ml injection of hot contrast medium was made after 5 min in each vessel. Venographic follow-up of the ablated veins was performed at 1 month (n = 12) and 2 months (n = 6). Results. Follow-up venograms showed that all ablated venous segments were occluded at 1 month. In 6 veins which were followed up to 2 months, 4 (66%) remained occluded, 1 (16%) was partially patent, and the remaining vein (16%) was completely patent. In these latter 2 cases, an inadequate amount of hot contrast was delivered to the lumen due to a closed balloon catheter downstream which did not allow contrast to displace blood within the vessel. Discussion. Hot contrast medium thermal ablation of the saphenous vein appears feasible, safe, and effective in the canine model, provided an adequate amount of embolization agent is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Therapeutic Results of Computed Tomography-Guided Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma: Results of 265 Tumors in 79 Patients

Purpose. To elucidate the local therapeutic results of computed tomography (CT)-guided transcatheter arterial chemoembolization (TACE) as initial treatment for hepatocellular carcinoma (HCC), and to verify factors which affect local therapeutic results. Methods. From 1992 to 2002, 265 tumors of 79 HCC patients were treated by 139 sessions of CT-guided TACE as initial treatment. Among these 265 tumors, 182 constituted multiple new lesions, and the remaining 83 tumors were single new lesions. Local recurrence was retrospectively ascertained on follow-up CT images obtained after TACE. Results. The overall local recurrence-free rates (LR-FRs) after a single TACE session at 6, 12, and 36 months were 67%, 49%, and 28%; those of the single new lesions were 80%, 66%, and 32%; and those of tumors with complete lipiodol accumulation were 82%, 68%, and 41%, respectively. LR-FRs of tumors of the single new lesions, and those of tumors with complete lipiodol accumulation, were significantly higher than the LR-FRs of multiple new lesions and tumors with incomplete lipiodol accumulation, respectively. For single new lesions {<=}4 cm and the tumors that were one of multiple new lesions, there were no significant differences in the LR-FRs regarding the number of TACE sessions on the basis of patient, tumor location, or tumor size. Conclusion. Local therapeutic results of single new lesions were better than those of multiple new lesions, and the local therapeutic effect of TACE was not affected by the number of treatments on the basis of patient, tumor location, or tumor size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutting Balloon Angioplasty (CBA) Versus Conventional Balloon Angioplasty (PTA) in the Pre-Dilatation of Carotid Artery Stenosis: Our Preliminary Experience

A retrospective study was carried out to evaluate the efficacy and safety of cutting-balloon angioplasty (CBA) for the predilatation of tight fibrocalcified carotid stenosis before carotid artery stenting (CAS). We also compared the intraprocedural results of CBA with those of conventional percutaneous transluminal angioplasty (PTA) in terms of postdilatation rate. The study population was composed of 32 patients who underwent CAS requiring predilatation before stent implantation. In detail, predilatation was performed by using a conventional balloon (PTA) in 14 patients (group A) and a cutting balloon (CBA) in 18 patients (group B). Intraprocedural and periprocedural mortality, major and minor procedural and neurologic complications, arterial damage, and embolic debris found in the distal filter were recorded. We statistically compared the rate of postdilatation obtained in the two groups. Technical success was obtained in 100% of the cases. No death, major neurologic or periprocedural complications, or arterial damage were recorded in either group. Minor neurologic reactions were recorded in 1 patient from group A (4%) and in 1 patient from group B (3%). Embolic debris was found in the distal filter in 2 patients from group A (8%) and in 3 patients from group B (10%). Postdilatation was necessary in 14 patients from group A (100%) and in 9 patients from group B (50%) (p < 0.05). Although limited to a small number of patients, compared with PTA, CBA seems to be a safe and effective procedure for the predilatation of tight fibrocalcified carotid stenoses before stent placement and may decrease the need for postdilatation in this patient population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonary embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In conclusion, there was an increase in the use of retrievable filters over the study period and an overall increase in the total number of filters implanted. The increased use of these filters appeared to be due to expanded indications predicated by their retrievability. Placement and retrieval of these filters have a low risk of complications, and retrievable filters appeared effective, as there was low rate of clinically significant pulmonary embolism associated with these filters during their indwelling time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of an Insulinoma of the Pancreas with Trisacryl Gelatin Microspheres as Definitive Treatment

Insulinomas are rare, mostly benign neuroendocrine tumors, originating in 99% of cases from the pancreas, that synthesize and secrete insulin, causing symptomatic hypoglycemia. Today the treatment of choice is surgical removal. We present the case of an 84-year-old woman with a symptomatic insulinoma who refused surgery and was treated with arterial embolization using trisacryl gelatin microspheres as definitive treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infarction of Uterine Fibroids After Embolization: Relationship Between Postprocedural Enhanced MRI Findings and Long-Term Clinical Outcomes

Purpose. To retrospectively evaluate the relationship between the degree of infarction of uterine fibroids on enhanced MRI after embolization and long-term clinical outcomes. Methods. During 92 months, 290 consecutive patients with symptomatic uterine fibroids were treated with embolization; 221 who underwent enhanced MRI before embolization and 1 week after embolization were included in this study. The infarction rates of all fibroid tissue were assessed using enhanced MRI after embolization. Patients were divided into three groups according to the infarction rates: group A (100% infarction, n 142), group B (90-99% infarction, n = 74), group C (<90% infarction, n = 5). The cumulative rates of clinical outcomes were compared among groups using the Kaplan-Meier limited method. Results. Group A had a significantly higher rate of symptom control than groups B and C. The cumulative rates of symptom control at 5 years were 93%, 71%, and 60% in groups A, B, and C, respectively. Group A had a significantly lower rate of gynecologic intervention after embolization than groups B and C. The cumulative rates of additional gynecologic intervention at 5 years were 3%, 15%, and 20% in groups A, B, and C, respectively. Conclusions. The degree of infarction of uterine fibroids after embolization on enhanced MRI was related to long-term clinical outcomes. Complete infarction of all fibroid tissue can induce a higher rate of symptom control, with a lower rate of additional gynecologic intervention in the long term compared with incomplete infarction of fibroid tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon Angioplasty Optimization: Should We Measure Balloon Volume As Well As Pressure?

Purpose. To investigate the influence that measurement of balloon volume as a controlled variable in addition to balloon pressure has on the outcome of balloon angioplasty in an experimental model. Methods. One hundred and three segments of explanted normal porcine carotid arteries were obtained. Five were used as controls, and the remaining 98 were subjected to balloon angioplasty with simultaneous measurement of balloon volume and pressure. These arteries were randomized into two groups. In one group the endpoint of the angioplasty was determined by balloon pressure (pressure-limited group, PLG) and in the other group by balloon volume (volume-limited group, VLG). Pressure/volume curves for each procedure were constructed by continuous measurement of both parameters by a purpose-designed computer-controlled inflation device. The diameter of each arterial segment was measured by intravascular ultrasound (IVUS) and the ratio of the inflated balloon to arterial diameter calculated. Arterial appearances after angioplasty were recorded using IVUS. Results. The balloon volumes measured at the endpoint of angioplasty were significantly smaller in the PLG compared with the VLG (p < 0.001). Three types of pressure/volume curves were identified: A, B, and C. In the type A curves, IVUS identified fissures in 28% (17/60) and the examination was normal in 72% (43/60). In the type B curves, IVUS identified fissures in 44% (4/9), dissections in 22% (2/9), and the examination was normal in 33% (3/9). In the type C curves, IVUS identified fissures in 44% (4/9) and dissection in 56% (5/9) with no normal examinations. In undamaged arterial segments a very high correlation was achieved between balloon volume and the balloon/artery ratio (Pearson correlation = -0.979, R{sup 2} = 0.957, p < 0.0001, n = 27). Conclusion. The measurement of pressure and volume during angioplasty enabled the construction of pressure/volume curves that showed deviations from the curves obtained in air. The balloon volume results, and significant deviation of the curve shape from the control curve shape, predicted vessel damage, which was confirmed by the IVUS appearance of the vessel after angioplasty. When pressure was used as the endpoint of balloon inflation the balloons were significantly underdilated compared with the manufacturer's nominal sizes. These data indicate that monitoring of pressure and volume during angioplasty may provide an alternative method of predicting vessel damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postpyelolithotomy Renal Artery Pseudoaneurysm Management with Percutaneous Thrombin Injection: A Case Report

Renal artery pseudoaneurysm leading to life-threatening hematuria can occur after a surgical procedure such as pyelolithotomy, albeit rarely. With recent advances in transarterial embolization techniques, this minimally invasive procedure has become the treatment of choice, replacing surgery. We present a case of massive hematuria due to renal artery pseudoaneurysm developing after pyelolithotomy that was managed with percutaneus thrombin injection directly into the pseudoaneurysm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Empyema and Effusion: Outcome of Image-Guided Small-Bore Catheter Drainage

Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Percutaneous Jejunostomy-An Underutilized Interventional Technique?

Our aim in this study was to report our single-center experience with direct percutaneous jejunostomy over a 4-year period with regard to technical success rate, immediate and late complications, and patient tolerance of the procedure. Institutional records of 22 consecutive patients who underwent radiological insertion of a percutaneous jejunostomy for a variety of indications were reviewed. The proximal jejunum was punctured under either fluoroscopic or ultrasonic guidance, and following placement of retention sutures, a 10- to 12-Fr catheter inserted. There was a 100% technical success rate in placement involving a total of seven operators. The indications for placement were prior gastric resection, newly diagnosed resectable esophageal or gastric carcinoma, unresectable gastric carcinoma with outlet obstruction, and palliative drainage of bowel obstruction. Mean duration of follow-up was 100 days, and catheter placement 57.7 days. There were six minor early complications, consisting of loss of two retention anchors requiring repuncture, three cases of localized excessive postprocedural pain, and one failed relief of symptoms of small bowel obstruction. Four tubes developed late complications (two blocked, one catheter cracked, and one inadvertently pulled out). Three of the four were successfully replaced through the existing tracts. One patient subsequently developed a minor skin infection, while another developed late pericatheter leakage from ascites. We conclude that direct percutaneous jejunostomy is a valuable treatment modality applicable to a number of clinical scenarios, with a high technical success rate and low serious complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Lost or Misplaced Intravascular Objects: Experiences of 12 Years

This paper reports our experience with endovascular techniques for the retrieval of lost or misplaced intravascular objects. Over 12 years, 78 patients were referred for interventional retrieval of intravascular foreign objects. In this retrospective study, radiological procedure records and patients' medical records were reviewed to determine the exact removal procedure in every case, to report success rates, and to identify significant procedure-related complications. Written, informed consent was obtained from all patients prior to the intervention; this retrospective analysis was performed according to the guidelines of the Institutional Review Board. Thirty-six of seventy-eight foreign objects (46%) were located in the venous system, 27 of 78 (35%) in the right heart, and 15 of 78 (19%) in the pulmonary arteries. For foreign object removal, in 71 of 78 (91%) cases a snare loop was used, in 6 of 78 (8%) cases a sidewinder catheter combined with a snare loop was used, and in 1 case (1%) a sidewinder catheter alone was used for foreign object removal. In 68 of 78 (87%) cases, primary success was achieved. In 3 of 78 cases (4%), foreign objects were successfully mobilized to the femoral vessels and surgically removed. In 7 of 78 cases (9%), complete removal of the foreign object was not possible. In 5 of 78 cases (6%), minor complications occurred during the removal procedure. In conclusion, endovascular retrieval of lost or misplaced intravascular objects is highly effective, with relatively few minor complications. On the basis of our findings, these techniques should be considered as the therapy of choice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR Reproducibility in the Assessment of Uterine Fibroids for Patients Scheduled for Uterine Artery Embolization

Magnetic resonance imaging (MRI) is increasingly applied in the evaluation of uterine fibroids. However, little is known about the reproducibility of MRI in the assessment of uterine fibroids. This study evaluates the inter- and intraobserver variation in the assessment of the uterine fibroids and concomitant adenomyosis in women scheduled for uterine artery embolization (UAE). Forty patients (mean age: 44.5 years) with symptomatic uterine fibroids who were scheduled for UAE underwent T{sub 1}- and T{sub 2}-weighted MRI. To study inter- and intraobserver agreement 40 MR images were evaluated independently by two observers and reevaluated by both observers 4 months later. Inter- and intraobserver agreement was calculated using Cohen's {kappa} statistic and intraclass correlation coefficient for categorical and continuous variables, respectively. Inter-observer agreement for uterine volumes ({kappa} = 0.99, p < 0.0001), dominant fibroid volumes ({kappa} = 0.98, p {<=} 0.0001), and number of fibroids ({kappa} = 0.88; CI, 0.77-0.93; p < 0.0001) was excellent. For the T{sub 1}- and T{sub 2}-weighted signal intensity of the dominant fibroid there was good agreement between the observers (87%; 95% CI, 71.9%-95.6%) and the intraobserver agreement was good for observer A (95%; 95% CI, 83.1%-99.4%) and moderate for observer B ({kappa} = 0.47). The interobserver agreement with respect to the presence of adenomyosis was good ({kappa} = 0.73, p < 0.0001), while both intraobserver agreements were fair to moderate (observer A, {kappa} = 0.55, p = 0.0003; and observer B, {kappa} = 0.66, p < 0.0001). In conclusion, MRI criteria used for the selection of suitable UAE patients show good inter- and intraobserver reproducibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗