Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

One System, Many Models: Designing a Surrogate Model for Sulfur Thermal Energy Storage: Preprint

Industrial process heating (IPH) relies primarily on thermal energy generated by fossil fuel combustion to produce, treat, and alter manufactured goods. Thermal energy storage (TES) helps reduce the carbon footprint of IPH systems by facilitating the utilization of renewable and waste heat sources. A promising new TES technology uses elemental sulfur as the heat-storage medium. The design of sulfur TES systems can be evaluated with the aid of computational fluid dynamics (CFD). However, the computational cost of such CFD efforts is prohibitive to comprehensive optimizations over design parameters. To reduce this computational cost, machine learning (ML) models can be developed to act as surrogates for CFD. In this paper, we describe the process of building and evaluating surrogate ML models for facilitating optimization of sulfur TES systems for IPH. To enforce the thermodynamic relationship between the two modeled quantities, we develop a hybrid model for sulfur temperature using both direct predictions of temperature and calculations of temperature from predictions of the heat transfer coefficient. The hybrid model enforces this constraint at the expense of the slightly reduced accuracy compared to two disjoint models. The overall high accuracy observed in our model evaluation demonstrates the usefulness of such surrogate modeling for studying TES systems. This work contributes to the field of TES surrogate modeling by offering a novel accurate hybrid approach to predicting simultaneously the heat transfer coefficient and temperature of the heat storage medium.

computational fluid dynamics↗

A Dynamic Model of Refrigerator with Thermal Energy Storage for Demand Flexibility

A refrigerator is an essential appliance for both commercial and residential applications. Thermal (Cold) energy storage can effectively reduce the carbon emission from refrigerators. This preliminary study investigated the demand flexibility of a domestic refrigerator using thermal (cold) energy storage through dynamic modeling and controls. The models include both fresh and frozen compartments, a vapor compression cycle loop, and thermal storage panels. Results show that thermal energy storage can effectively achieve temperature control of the compartments within the 4-hour time window. The load reduction and cost savings (46.3%) were achieved through the TES using TOU rates.

Gao, Zhiming↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Economic Analysis of an Electric Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The renewable power integration with storage can support future carbon-free utility and has several significant impacts including increasing the value of renewable generation to the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Economic Analysis of a Novel Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage: Preprint

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The integration of renewable power and storage to support future carbon-free utility has several significant and positive impacts including expanding the renewable generation into the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Integrated Thermal Energy Storage and Brayton Cycle Equipment Demonstration (Integrated TESTBED) Project Design Basis

The Integrated Thermal Energy Storage and Brayton cycle Equipment Demonstration (Integrated TESTBED) project seeks to retire commercial-scale risks associated with the design, integration,and operation of a supercritical carbon dioxide (sCO2) power cycle and concentrating solar power (CSP) thermal energy storage (TES) system. This requires an understanding of commercial-scale collector system transient impacts on the TES system, the dynamics of heat exchange from theTES to the power cycle, and the control and operation of the power cycle to accommodate various dispatch strategies. In order to retire these risks, Heliogen has proposed to construct a 5 MWe CSP demonstration facility based on directly heated particle and sCO2 technology. The receivers, primary heat exchanger, and power cycle will be deployed at a full commercial scale based on Heliogen’s modular plant architecture to ensure actual system integration risks are validated during design, construction, and operation. This work summarizes the design basis for the Integrated TESTBED project demonstration facility including a design target for capacity factor to support test operations, hours of storage, particle silo arrangement, centrifugal article receivers, a diffusion bonded particle-sCO2 heat exchanger, and a 5 MWe (net) integrally geared sCO2 recompression Brayton cycle.

14 SOLAR ENERGY↗

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Evaluation of in-situ thermal energy storage for lunar based solar dynamic systems

A practical lunar based thermal energy storage system, based on locally available materials, could significantly reduce transportation requirements and associated costs of a continuous, solar derived power system. The concept reported here is based on a unique, in-situ approach to thermal energy storage. The proposed design is examined to assess the problems of start-up and the requirements for attainment of stable operation. The design remains, at this stage, partially conceptional in nature, but certain aspects of the design, bearing directly on feasibility, are examined in some detail. Specifically included is an engineering evaluation of the projected thermal performance of this system. Both steady state and start-up power requirements are evaluated and the associated thermal losses are evaluated as a basis for establishing potential system performance.

Crane, Roger A.↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Particle-wall heat transfer in narrow-channel bubbling fluidized beds for thermal energy storage

Robust metal oxide particles can provide low-cost and stable thermal energy storage (TES) to temperatures up to 1200 °C or higher. The transfer of heat into and out of the particles in cost-effective high-temperature particle heat exchangers remains a principal challenge to implementing particle-based TES. The present work expands on prior studies of particle-wall heat transfer in narrow-channel fluidized beds operated in the bubbling fluidization regime. Batch-mode experiments with various oxide particles over a range of temperatures and airflow rates indicate that particle-wall heat transfer increases with higher bed temperature and decreasing particle size. Measured particle-wall heat transfer coefficients in a 12 mm deep channel are fit to a Nusselt number correlation proportional to a non-monotonic function of excess fluidization velocity. Particle-wall heat transfer coefficients rise rapidly with excess fluidization velocities until reaching a maximum at intermediate air velocities due to a trade-off between enhanced transverse particle mixing and decreasing particle volume fraction with increased fluidization velocity. The heat transfer coefficient reaches a maximum of ≈ 400% of values without fluidization for oxide particles ranging in diameter d p from 159 to 408 μm. For the smallest particles tested, composed of olivine sand, particle-wall heat transfer coefficients peak above 1100 Wm –2 K –1 at 450 °C. 100-h tests at 500 °C and near-optimal heat transfer fluidization velocities indicated minimal wall wear or oxide scaling. Furthermore, high particle-wall heat transfer coefficients suggest narrow channel fluidized beds as a potential pathway for reducing the required surface area and cost of high-temperature particle heat exchangers, as needed in large-scale thermal energy storage applications.

14 SOLAR ENERGY↗

Active heat exchange system development for latent heat thermal energy storage

Active heat exchange concepts for use with thermal energy storage systems in the temperature range of 250 C to 350 C, using the heat of fusion of molten salts for storing thermal energy are described. Salt mixtures that freeze and melt in appropriate ranges are identified and are evaluated for physico-chemical, economic, corrosive and safety characteristics. Eight active heat exchange concepts for heat transfer during solidification are conceived and conceptually designed for use with selected storage media. The concepts are analyzed for their scalability, maintenance, safety, technological development and costs. A model for estimating and scaling storage system costs is developed and is used for economic evaluation of salt mixtures and heat exchange concepts for a large scale application. The importance of comparing salts and heat exchange concepts on a total system cost basis, rather than the component cost basis alone, is pointed out. The heat exchange concepts were sized and compared for 6.5 MPa/281 C steam conditions and a 1000 MW(t) heat rate for six hours. A cost sensitivity analysis for other design conditions is also carried out.

Lefrois, R. T.↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of thermal energy storage for the proposed Twin Cities District Heating system

The technical and economic feasibility of incorporating thermal energy storage components into the proposed Twin Cities District heating project was evaluated. The technical status of the project is reviewed and conceptual designs of district heating systems with and without thermal energy storage were compared in terms of estimated capital requirements, fuel consumption, delivered energy cost, and environmental aspects. The thermal energy storage system is based on cogeneration and the storage of heat in aquifers.

Meyer, C. F.↗

Mathematical modeling of moving boundary problems in thermal energy storage

The capability for predicting the performance of thermal energy storage (RES) subsystems and components using PCM's based on mathematical and physical models is developed. Mathematical models of the dynamic thermal behavior of (TES) subsystems using PCM's based on solutions of the moving boundary thermal conduction problem and on heat and mass transfer engineering correlations are also discussed.

Solomon, A. D.↗

Design of a Meso-Scale Test of a Fracture Thermal Energy Storage (FTES) System

This paper will present the characterization, scaling, and design of an intermediate-scale field test of a fracture thermal energy storage system (FTES). Seasonal storage of thermal energy has the potential to both significantly reduce the total energy requirements for heating and cooling of buildings, but also allow for the flexibility to store thermal energy from intermittent sources. With approximately half of global energy consumption currently being used for heating and cooling, this represents an important path to reducing greenhouse gas (GHG) emissions. The concept of FTES is to drill two or more wells into a low permeability formation, generally at a depth of less than a few hundred meters, and then generate hydraulic fractures to create flow paths for water to circulate between the wells. Hot or cold thermal energy can then be stored in the surrounding rock mass by circulating hot or cold water through the fractures, which will heat or cool the rock mass. To recover the stored energy, ambient temperature water can be then circulated through the fractures, which will then be heated or cooled by the rock mass. Fractures inherently have a very large ratio of surface area to volume. This allows for very high heat fluxes to and from the rock mass to be achieved despite the relatively low thermal conductivity of most geologic formations. Because large fractures can be made with low-cost equipment and with only inexpensive and environmentally safe materials such as water and sand, the cost to construct even large FTES systems is expected to be quite low. This paper will present what the performance requirements, size, and operating conditions of a full-scale system to operate a commercial building. The paper will describe how these full-scale system characteristics will be used as a design basis for an intermediate-scale FTES test to be conducted at the Sanford Underground Research Facility (SURF) in Lead, SD.

Burghardt, Jeffrey A.↗

Intelligent Control of Thermal Energy Storage in the Manufacturing Sector for Plant-Level Grid Response

Industrial facilities are seeking new strategies that help in providing savings mechanisms for demand charges. Demand charges are the charges incurred by industrial facilities as a result of power usage. Thermal energy storage has advanced significantly with lots of new applications, garnering the interest of many industrial facilities. These applications could be used to shave the industrial facilities’ peak electric demand and reduce their demand charges. This paper aims to demonstrate the efficacy of thermal energy storage in reducing demand charges and highlight new developments in the integration of smart control systems with thermal energy storage. The study compares energy consumption and peak demand for a facility equipped with and without thermal energy storage tanks using a fixed schedule for charging and discharging. Additionally, the paper examines the impact of incorporating a smart controller to determine when to charge and discharge the tank based on the facility’s real-time power usage and a given setpoint. The results indicate cost savings from the use of thermal energy storage tanks under two proposed scenarios, reflected in the reduced cost of power consumption for the studied facility. The incorporation of a smart controller with the thermal energy storage tank in the facility studied could provide estimated savings of 3.3% per year of power consumption charges, without considering the contribution of any incentives. The estimated savings provided by the fixed schedule scenario are 2.7% per year.

25 ENERGY STORAGE↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗