Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fuel Heating System Design and Thermal Modeling for Aviation Combustion Research

Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.

Jet fuel heating system↗

Hall Thruster Thermal Modeling and Test Data Correlation

HERMeS - Hall Effect Rocket with Magnetic Shielding. Developed through a joint effort by NASA/GRC and the Jet Propulsion Laboratory (JPL). Design goals: High power (12.5 kW) high Isp (3000 sec), high efficiency (> 60%), high throughput (10,000 kg), reduced plasma erosion and increased life (5 yrs) to support Asteroid Redirect Robotic Mission (ARRM). Further details see "Performance, Facility Pressure Effects and Stability Characterization Tests of NASAs HERMeS Thruster" by H. Kamhawi and team. Hall Thrusters (HT) inherently operate at elevated temperatures approx. 600 C (or more). Due to electric magnetic (E x B) fields used to ionize and accelerate propellant gas particles (i.e., plasma). Cooling is largely limited to radiation in vacuum environment.Thus the hardware components must withstand large start-up delta-T's. HT's are constructed of multiple materials; assorted metals, non-metals and ceramics for their required electrical and magnetic properties. To mitigate thermal stresses HT design must accommodate the differential thermal growth from a wide range of material Coef. of Thermal Expansion (CTEs). Prohibiting the use of some bolted/torqued interfaces.Commonly use spring loaded interfaces, particularly at the metal-to-ceramic interfaces to allow for slippage.However most component interfaces must also effectively conduct heat to the external surfaces for dissipation by radiation.Thus contact pressure and area are important.

Model↗

Saturn's icy satellites - Thermal and structural models

Thermal history models which assume formation as homogeneous ice-silicate mixtures are constructed for the small, icy Saturnian satellites Mimas, Tethys, Dione, Rhea, and Iapetus, including the effects of radiogenic and accretional heating, conductive and subsolidus convective heat transfer, and lithosphgeric growth. Accretional heating is not likely to have melted the water ice in the interiors of these bodies, and solid state creep of the ice-dominated material precludes melting by radiogenic heating. The four largest satellites are sufficiently large and rich in heat-producing silicates to possess a solid state convection system beneath a rigid lithosphere, irrespective of initial conditions. The model thermal histories are qualitatively consistent with the present appearances of these satellites.

Ellsworth, K.↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

Discrete Green’s functions and spectral graph theory for computationally efficient thermal modeling

Here, this work concerns solutions of the heat equation with the spectral graph method, for which the temperature is defined at discrete points in the domain and the spatial relationship among the points is described by a graph. The heat equation on the graph is solved using matrix techniques involving the eigenvectors and eigenvalues of the Laplacian matrix. The spectral graph approach precludes the computationally intensive meshing and numerous time-integration steps of the finite element method. In the present work, the spectral graph method is extended to include heat loss at the boundaries with a generalized boundary condition, and physics-based edge weights are introduced which simplify the calibration process. From this approach a discrete Green’s function is defined which allows for solutions under a variety of heating conditions including: space-varying initial conditions; time-and-space varying internal heating; and, time-and-space-varying heating at boundaries of type 1 (Dirichlet), type 2 (Neumann) and type 3 (Robin). Results are provided for benchmark heat transfer problems in one spatial dimension and in three spatial dimensions, and verification is provided by comparison with exact analytical solutions and finite difference solutions. The spectral graph method converges within 0.4% error of the analytical solution. The practical utility of the approach is demonstrated by thermal simulation of a multilayer additive manufacturing process. The spectral graph results are compared to experimentally-obtained temperature data for two metal parts, with error less than 5% of the experimental measurements, with computation time less than one minute on a desktop computer.

36 MATERIALS SCIENCE↗

Safe Affordable Fission Engine (SAFE 30) Module Conductivity Test Thermal Model Correlation

Two SAFE 30 modules were tested to determinate the thermal conductivity efficiency of the tri-cusps filled between the heat pipe and the heater cores. The modules consisted of four one-inch diameter tubes with heaters joined to an empty 1 inch diam. tube. The test was conducted on a vacuum chamber with 4 configurations: tri-cusps filled with and without radiation shielding and non-filled tri-cusps with and without radiation shielding. The tri-cusps material helps the bonding of the heat pipe to the four electric heater cores, filling the gap between the pipes. The baseline configuration is a brazed joint between the pipe. The test consisted of controlling the power applied to the heaters until a set surface temperature is reach. The temperatures varied between a max. of 800 C to 500 C. Test data, input energy and chamber surface temperature from each individual test, was used as boundary conditions for the model. Nodes located on the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown n variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis varying the surface emissivity and view factor until a good match was reach.

Roman, Jose↗

Thermal Modeling of an Advanced Geared Turbofan for Distributed Engine Control Application

Reliability and life-expectancy of gas turbine engine components is very much correlated to the temperature environment in which they operate. This is no different for control system components, especially those with electronic parts. In recent years, the concept of Distributed Engine Control (DEC) has emerged to address the limitations of the current centralized control implementation. This new approach involves relocating control system components from a relatively benign environment to the harsher thermal environment of the engine casing and its surrounding structures and cavities. In this paper, an approach to modeling the gas turbine thermal environment is described. The modeling approach is applied to a 3rd generation geared turbofan design with a focus on the engine locations where control instrumentation and actuation could be installed. The analysis was conducted with an eye toward component reliability and service life as it relates to the thermal environment. The results were found to be reasonable. Furthermore, the model is shown to execute in real-time within a multi-model simulation environment that demonstrates the capability to interact with hardware to drive test equipment.

Kratz, Jonathan↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Adiabatic and nonadiabatic processes in thermal models of solar hard X-ray bursts

The temporal evolution of thermal-bremsstrahlung-emitting material at the top of a solar coronal loop under various processes is examined as a model of solar hard X-ray bursts. The behavior of emission measure and temperature with time is analyzed for the hot plasma confined in a segment at the top of a loop, taking into account the effects or the time variation of the confining toroidal magnetic field, the longitudinal expansion of the source through the motion of a pair of collisionless conduction fronts and unspecified heating or cooling processes. Analytic expressions for the behavior of the toroidal magnetic field and the heating rate necessary to reproduce a given behavior of emission measure and temperature with time are obtained in terms of the initial magnetic field strength and density of the heated region and a characteristic longitudinal expansion time. Results are applied to observations of two impulsive solar hard X-ray bursts, and it is shown that the contribution of heating is negligible after the first few seconds of the events, although significant nonadiabatic heating occurs early in the events.

Emslie, A. G.↗

A thermal model for analysis of infrared images

A mathematical model derived from the equation of heat conduction was developed to assist in interpreting thermal infrared images acquired from aircraft and spacecraft. The model assumes steady state boundary conditions. It contains parameters of rock and soil properties, atmospheric effects, site location, and season. The results predicted provide an explanation for the thermal differences among granite, limestone, and dolomite recorded in the December 1968 daytime and predawn flights over the Mill Creek, Oklahoma test site, during which representative thermal inertia and albedo values were used. A second test of the model made use of data acquired during the June 1970 predawn overflight of Mill Creek. A simple model of transient heating of the ground was constructed as an extension of the overall model, in order to examine the effects of atmospheric perturbations. The results obtained are consistent with those of ground observations made at the time of the overflight.

Watson, K.↗

One-dimensional thermal modeling of vertical Bridgman-type crystal growth

Articles by Naumann (1982) and Jasinski et al. (1983) examined the axial temperature distribution of the charge during vertical Bridgman-type crystal growth. A comparison of their results demonstrates that Naumann's model is applicable for K (ratio of crucible to charge thermal conductivity) equal to or greater than 1 or for small Biot numbers. The Jasinski model provides a correction for larger Biot numbers and is also applicable for small values of K.

Jasinski, T.↗

Preliminary Thermal Modeling of HI-STORM 100 Storage Modules at Diablo Canyon Power Plant ISFSI

Thermal analysis is being undertaken at Pacific Northwest National Laboratory (PNNL) in support of inspections of selected storage modules at various locations around the United States, as part of the Used Fuel Disposition Campaign of the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) Fuel Cycle Research and Development. This report documents pre-inspection predictions of temperatures for two modules at the Diablo Canyon Power Plant ISFSI identified as candidates for inspection. These are HI-STORM 100 modules of a site-specific design for storing PWR 17x17 fuel in MPC-32 canisters. The temperature predictions reported in this document were obtained with detailed COBRA-SFS models of these storage systems, with the following boundary conditions and assumptions. • storage module overpack configuration based on FSAR documentation of HI-STORM100S-218, Version B; due to unavailability of site-specific design data for Diablo Canyon ISFSI modules • Individual assembly and total decay heat loadings for each canister, based on at-loading values provided by PG&E, “aged” to time of inspection using ORIGEN modeling - Special Note: there is an inherent conservatism of unquantified magnitude – informally estimated as up to approximately 20% -- in the utility-supplied values for at-loading assembly decay heat values • Axial decay heat distributions based on a bounding generic profile for PWR fuel. • Axial location of beginning of fuel assumed same as WE 17x17 OFA fuel, due to unavailability of specific data for WE17x17 STD and WE 17x17 Vantage 5 fuel designs • Ambient conditions of still air at 50°F (10°C) assumed for base-case evaluations - Wind conditions at the Diablo Canyon site are unquantified, due to unavailability of site meteorological data - additional still-air evaluations performed at 70°F (21°C), 60°F (16°C), and 40°F (4°C), to cover a range of possible conditions at the time of the inspection. (Calculations were also performed at 80°F (27°C), for comparison with design basis assumptions.) All calculations are for steady-state conditions, on the assumption that the surfaces of the module that are accessible for temperature measurements during the inspection will tend to follow ambient temperature changes relatively closely. Comparisons to the results of the inspections, and post-inspection evaluations of temperature measurements obtained in the specific modules, will be documented in a separate follow-on report, to be issued in a timely manner after the inspection has been performed.

Site Inspection↗

Investigations on Repository Near-Field Thermal Modeling - Repository Science/Thermal Load Management & Design Concepts (M41UF033302)

The various layers of material from the waste package (such as components of the engineered barrier system and the host rock surface) to a given distance within the rock wall at a given distance can be described as concentric circles with varying thermal properties (see Figure 5.1-1). The selected model approach examines the contributions of the waste package, axial waste package neighbors and lateral neighboring emplacement drifts (see Section 5.2.1 and Appendix H, Section 2). In clay and deep borehole media, the peak temperature is driven by the central waste package whereas, in granite and salt, the contribution to the temperature rise by adjacent (lateral) waste packages in drift or emplacement borehole lines is dominant at the time of the peak temperature. Mathematical models generated using Mathcad software provide insight into the effects of changing waste package spacing for six waste forms, namely UOX, MOX, co-extraction, new extraction, E-Chem ceramic and E-Chem metal in four different geologic media (granite, clay, salt and deep borehole). Each scenario includes thermal conductivity and diffusivity for each layer between the waste package and the host rock, dimensions of representative repository designs (such as waste package spacing, drift or emplacement borehole spacing, waste package dimensions and layer thickness), and decay heat curves generated from knowledge of the contents of a given waste form after 10, 50, 100 and 200 years of surface storage. Key results generated for each scenario include rock temperature at a given time calculated at a given radius from the central waste package (Section 5.2.1 and Appendix H, Section 3), the corresponding temperature at the interface of the waste package and EBS material, and at each EBS layer in between (Section 5.2.2 and Appendix H, Section 4). This information is vital to understand the implications of repository design (waste package capacity, surface storage time, waste package spacing, and emplacement drift or borehole spacing) by comparing the peak temperature to the thermal limits of the concentric layers surrounding the waste package; specifically 100 C for the bentonite buffer in granite and clay repositories, 100 C for rock wall in a clay repository and 200 C at the rock wall for a salt repository. These thermal limits are both preliminary and approximate, and serve as a means to evaluate design options rather than determining compliance for licensing situations. The thermal behavior of a salt repository is more difficult to model because it is not a concentric geometry and because the crushed salt backfill initially has a much higher thermal resistance than intact salt. Three models were investigated, namely a waste package in complete contact with crushed salt, secondly a waste package in contact with intact salt, and thirdly a waste package in contact with 75% intact and 25% crushed salt. The latter model best depicts emplacement of a waste package in the corner of an intact salt alcove and subsequently covered with crushed salt backfill to the angle of repose. The most conservative model (crushed salt) had temperatures much higher than the other models and although bounding, is too conservative to use. The most realistic model (75/25) had only a small temperature difference from the simplest (non-conservative, intact salt) model, and is the one chosen in this report (see Section 5.2.3). A trade-study investigating three key variables (surface storage time, waste package capacity and waste package spacing) is important to understand and design a repository. Waste package heat can be reduced by storing for longer periods prior to emplacement, or by reducing the number of assemblies or canisters within that waste package. Waste package spacing can be altered to optimize the thermal load without exceeding the thermal limits of the host rock or EBS components. By examining each of these variables, repository footprint (and therefore cost) can be optimized. For this report, the layout was fixed for each geologic medium based on prior published designs in the international community, but it will be varied in future work. Section 5.2.4 summarizes the conclusions based on varying two of the three parameters (storage time and waste package capacity), and the results are shown in Appendix H, Sections 5 and 6.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Thermal Modeling of Hi-Storm 100S-218 Version B Storage Modules at Hope Creek Nuclear Power Station ISFSI

This report fulfills the M3 milestone M3FT-13PN0810022, “Report on Inspection 1”, under Work Package FT-13PN081002. Thermal analysis is being undertaken at Pacific Northwest National Laboratory (PNNL) in support of inspections of selected storage modules at various locations around the United States, as part of the Used Fuel Disposition Campaign of the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) Fuel Cycle Research and Development. This report documents pre-inspection predictions of temperatures for four modules at the Hope Creek Nuclear Generating Station ISFSI that have been identified as candidates for inspection in late summer or early fall/winter of 2013. These are HI-STORM 100S-218 Version B modules storing BWR 8x8 fuel in MPC-68 canisters. The temperature predictions reported in this document were obtained with detailed COBRA-SFS models of these four storage systems, with the following boundary conditions and assumptions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigations on Repository Near-Field Thermal Modeling - Repository Science/Thermal Load Management & Design Concepts (M41UF033302) (Rev.1)

The modeling tools generated in MathCAD, Excel, and MatLab were used to calculate the temperature evolution for combinations of waste form and geologic medium, assuming a particular emplacement layout for each concept (Sutton et al. 2011). Two types of spent nuclear fuel assemblies (SNFA) were considered, namely UOX from an open fuel cycle and MOX from a modified-­‐open fuel cycle. Four types of high level waste (HLW) canisters were considered, namely “co-­‐extraction” glass from a modified-­‐open fuel cycle and “new extraction” glass, electrochemical ceramic (EC-­‐C) and electrochemical metal (EC-­‐M) from a closed fuel cycle. While the “coextraction” process is similar in function to the industrial Co-­‐Extraction™ (COEX) process deployed by AREVA, the two processes assume different processing methods and steps and so the product and waste streams cannot be directly compared. Similar is true for the “new extraction” process documented in this report and the NUEX industrial process proposed by Energy Solutions, which also cannot be directly compared.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Modeling Studies for Active Storage Modules in the Calvert Cliffs ISFSI

Temperature measurements obtained for two storage modules in the Calvert Cliffs Nuclear Power Station’s Independent Spent Fuel Storage Installation (ISFSI) as part of the Used Fuel Disposition Campaign of the Department of Energy (DOE) were used to perform validation and sensitivity studies on detailed computational fluid dynamics (CFD) models of the concrete storage modules, including the dry storage canister within the modules. The storage modules in the Calvert Cliffs Nuclear Power Station’s ISFSI are a site-specific version of the standard NUHOMS® HSM. The two modules inspected each contained a 24P DSC loaded with 24 CE 14x14 spent fuel assemblies. The thermal analysis was performed using the STAR-CCM+ package, and the models developed for the specific ISFSI modules yielded temperature predictions in actual storage conditions for the concrete structure, the DSC and its contents, including preliminary estimates of fuel cladding temperatures for the used nuclear fuel. The results of this work demonstrate that existing CFD modeling tools can be used to obtain reasonable and accurate detailed representations of spent fuel storage systems with realistic decay heat loadings when the model omits specific conservatisms and bounding assumptions normally used in design-basis and safety-basis calculations. This paper presents sensitivity studies on modeling detail (for the storage module and the DSC), boundary conditions, and decay heat load, to evaluate the effect of the modeling approach on predicted temperatures and temperature distributions. Because nearly all degradation mechanisms for materials and structures comprising dry storage and transportation systems are dependent on temperature, accurate characterization of local temperatures and temperature gradients that the various components of these systems will experience over the entire storage period has been identified as a primary requirement for evaluation of very long term storage of used nuclear fuel.

long term storage↗

A comparison of the height distributions of solar flare hard X-rays in thick target and thermal models

The height structure of hard X-ray bremsstrahlung emission in solar flares is computed for two different models of bremsstrahlung production: emission from a descending beam of nonthermal electrons, and thermal emission from a coronally confined hot plasma. It is shown how these models give rise to hard X-ray spatial distributions which are distinguishable by current instrumentation, and that, therefore, the models may be distinguished by such spatially resolved hard X-ray measurements.

Emslie, A. G.↗