Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Excitation and Evolution of the Quasi 2-Day Wave Observed in UARS/MLS Temperature Measurements

The quasi 2-day wave is known as a strong dynamic perturbation occurring usually after solstice in the middle and upper atmosphere. Propagating characteristics of the 2-day wave are studied based on 8- month temperature measurements from the Microwave Limb Sounder on the Upper Atmosphere Research Satellite. Possible causes of the excitation mechanism responsible for the 2-day wave are discussed.

atmospheric↗

Effect of Measurement Temperature on Electrical Cable Frequency Domain Reflectometry Response

In nuclear power plants, electrical cables are exposed to stressors, such as elevated temperature and radiation. Evaluation of the effect of stressors on the lifetime of electrical cables can be conducted using offline electrical reflectometry techniques, such as frequency domain reflectometry (FDR). However, recent work has raised the concern that FDR measurements at temperatures higher than ambient may diminish or reduce the response due to stressors, potentially leading to incorrect predictions of electrical cable damage and lifetime. In this work, we explore the FDR response of an electrical cable exposed to an oven-based thermal stressor up to 140°C, including both ramping up and ramping down temperature. It was observed that, for both the oven entrance and exit, an increase in the FDR measurement temperature led to a decrease in the FDR reflection coefficient. In particular, it was found that the reflection coefficient at the oven entrance decreased from the ambient measurement by approximately 7%, 22%, and 36% at a temperature of 60°C, 100°C, and 140°C, respectively.

Spencer, Mychal P.↗

Surface pyrometry in presence of radiation from other sources with application to turbine blade temperature measurement

Surface pyrometry is feasible even when the amount of surface radiation is exceeded by radiation from surrounding sources. To measure and correct for this interfering radiation, several methods that use multiple wavelength pyrometry were compared by an error analysis. For a specific application to turbine blade temperature measurement in a turbofan engine, a two wavelength method was best. Auxiliary measurements at the same wavelengths substantially improve the accuracy of the method.

Buchele, D. R.↗

An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently

A gas containment vessel that is not in thermal equilibrium with the bulk gas can affect its temperature measurement. The physical nature of many gas dynamics experiments often makes the accurate measurement of temperature a challenge. The environment itself typically requires that the thermocouple be sheathed, both to protect the wires and hot junction of the instrument from their environment, and to provide a smooth, rigid surface for pressure sealing of the enclosure. However, that enclosure may also be much colder than the gas to be sensed, or vice-versa. Either way, the effect of such gradients is to potentially skew the temperature measurements themselves, since heat may then be conducted by the instrument. Thermocouple designers traditionally address this problem by insulating the sheath from the thermocouple leads and hot junction as much as possible. The thermocouple leads are typically packed in a ceramic powder inside the sheath, protecting them somewhat from temperature gradients along the sheath, but there is no effective mechanism to shield the sheath from the enclosure body itself. Standard practice dictates that thermocouples be used in installations that do not present large thermal gradients along the probe. If this conduction dominates heat transfer near the tip of the probe, then temperature measurements may be expected to be skewed. While the same problem may be experienced in the measurement of temperature at various points within a solid in a gradient, it tends to be aggravated in the measurements of gas temperature, since heat transfer dependent on convection is often less efficient than conduction along the thermocouple. The proposed solution is an inefficient fin thermocouple probe. Conventional wisdom suggests that in many experiments where gas flows through an enclosure (e.g., flow in pipe, manifold, nozzle, etc.), the thermocouple be introduced flush to the surface, so as not to interfere with the flow. In practice, however, many such experiments take place where the flow is already turbulent, so that a protruding thermocouple probe has a negligible effect on the flow characteristics. The key question then becomes just how far into the flow should a thermocouple protrude in order to properly sense the gas temperature at that point. Modeling the thermocouple as an "inefficient fin" directly addresses this question. The appropriate assumptions in this case are: one-dimensional conduction along the fin; steady-state, constant, and homogeneous thermal conductivity; negligible radiation; and a uniform, constant heat transfer coefficient over the probe surface. It is noted that the nature of the ceramic-filled probe makes the key assumption of homogeneous thermal conductivity that much more conservative.

Lemieux, Patrick↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

CARS temperature measurements in the fuel preburner of the Space Shuttle main engine: A feasibility study

This report discusses the feasibility of making temperature profile measurements in the fuel preburner of the main engine of the space shuttle (SSME) using coherent anti-Stokes Raman spectroscopy (CARS). The principal thrust of the work is to identify problems associated with making CARS measurements in high temperature gas phase hydrogen at very high pressures (approx 400 atmospheres). To this end a theoretical study was made of the characteristics of the CAR spectra of H2 as a function of temperature and pressure and the accuracy with which temperatures can be extracted from this spectra. In addition the experimental problems associated with carrying out these measurements on a SSME at NSTL were identified. A conceptual design of a CARS system suitable for this work is included. Many of the results of the calculations made in this report are plotted as a function of temperature. In the course of presenting these results, it was necessary to decide whether the number of density or the pressure should be treated as a fixed parameter.

Beiting, E. J.↗

Body temperature measuring system (M171)

The body temperature probe is used in support of experiment M171 to determine if crewmen are storing heat following exercise and to monitor crew health in case of illness.

Lem, J. D.↗

Remote optical techniques for liquid flow and temperature measurement for Spacelab experiments

Three nonintrusive measurement techniques for Spacelab experiments are investigated. In the photochromic dye technique, a small amount of dye is dissolved in a low viscosity silicone oil and dye streaks are produced upon exposure to a UV source; the movement of the streaks reveals the flow. A laser Doppler dual-scatter system is being developed for low flow speed measurement; an accuracy of a few percent has been demonstrated for flows of a few millimeters per second. A double-grid schlieren system is being developed for temperature measurement; the optical arrangement is such that an image of a Ronchi ruling is superposed on the original ruling, giving a uniform gray field of view.

Fowlis, W. W.↗

Floating Probe Assembly for Measuring Temperature of Water

A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. These types of measurements are used in computer models to relate remotely sensed water-surface temperature to bulkwater temperature. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured.

Stewart, Randy↗

Infrared surface temperature measurements for the surface tension driven convection experiment

In support of the Surface Tension Driven Convection Experiment (STDCE), a planned space transportation system (STS) flight experiment, a commercially available infrared thermal imaging system is used to quantify the imposed thermal signature along the free surface. The system was tested and calibrated for the STDCE with ground-based equivalents of the STDCE hardware. Before using the system, consideration was given to the radiation characteristics of the target (silicone oil). Absorption coefficients were calculated to understand the surface depth as seen by the imager and the penetration depth of the surface heater (CO2 laser). The performance and operational specifications for the imager and image processing system are described in detail to provide an understanding of the equipment. Measurements made with the system were compared to thermocouple measurements and a calculated surface temperature distribution. This comparison showed that in certain regions the IR imager measurements were within 5 percent of the overall temperature difference across the free surface. In other regions the measurements were within + or - 10 percent of the overall temperature gradient across the free surface. The effective emissivity of silicone oil for these experimental conditions was also determined. Measurement errors and their possible solutions are discussed.

Pline, Alexander D.↗

Noncontact true temperature measurement

A laser pyrometer has been developed for acquiring the true temperature of a levitated sample. The laser beam is first expanded to cover the entire cross-sectional surface of the target. For calibration of such a system, the reflectivity signal of an ideal 0.95 cm diameter gold-coated sphere (reflectivity = 0.99) is used as the reference for any other real targets. The emissivity of the real target can then be calculated. The overall system constant is obtained by passively measuring the radiance of a blackbody furnace (emissivity = 1.0) at a known, arbitrary temperature. Since the photo sensor used is highly linear over the entire operating temperature range, the true temperature of the target can then be computed. Preliminary results indicate that true temperatures thus obtained are in excellent correlation with thermocouple measured temperatures.

Lee, Mark C.↗

Excitation and Evolution of the Quasi-2-Day Wave Observed UARS/MLS Temperature Measurements

The quasi-2-day wave is known as a strong and transient perturbation in the middle and upper atmosphere that often occurs shortly after solstice. The excitation mechanisms of this transient wave have been discussed for years, but no clear answer has yet been attained. In this paper, propagating characteristics of the 2-day wave are studied based on 8-mon temperature measurements from the Microwave Limb Sounder onboard the Upper Atmosphere Research Satellite. The studies are focused on the wave events that happened in January 1993 and in July-August 1993. The observations suggest that winter planetary waves could be responsible for triggering the summer 2-day wave through long penetration into the summer stratosphere. A connection is evident in the evolution of the wave amplitude between the summer 2-day wave generation and winter wave penetration. The data also suggest that the enhancement of the wave amplitude is a manifestation of both a local unstable wave and a global normal-mode Rossby wave.

Wu, D. L.↗

System and method for multi-channel pyrometer allowing non-contact temperature measurements down to 800 K on the microsecond scale

The present disclosure relates to a system for sensing temperature changes on a microsecond scale. The system uses a multi-channel pyrometer that works in the NIR spectrum to receive thermal radiation. Each channel includes an interference filter tuned to pass thermal radiation within a specified wavelength range, and a detector. Each detector detects thermal radiation focused on it. Each channel further includes an interference filter which reflects thermal radiation which does not pass through it to a subsequent downstream interference filter of a subsequent channel. Each subsequent interference filter is oriented to reflect the thermal radiation not passing through it to a next downstream one of the subsequent interference filters. A subsystem is included for receiving the output from the detectors and determining sensed temperature data therefrom, allowing measurement of temperatures down to 800 K.

Montgomery, Jeffrey↗

An efficient technique for determining apparent temperature distributions from antenna temperature measurements

A method by which the apparent microwave temperature characteristic of a flat scene is estimated from dual polarized measurements is derived and interpreted. Approximate linear relationships between antenna and apparent temperatures are established by weighting emission components in spherical bands under the assumption that the surface is isotropic. The weighting factors are formed by integrating the antenna pattern functions over these bands. The vector aspect of the formulation is retained to account for the difference between the definition of the antenna polarizations and the polarizations of the emitted fields. The method is largely applicable to the measurement of smooth temperature distributions by an antenna having good spatial resolution of the distributions and is considered efficient for inverting large volumes of measurements. Sample cases are presented and the implications of these cases on remote radiometer observations are discussed. It is shown that cross-coupling occurs between the polarizations of the emitted fields and the polarizations of the antenna. For this reason and because practical antennas have cross-polarized patterns associated with them, it is necessary to conduct measurements at both horizontal and vertical polarizations to realize the inversion. It is also made evident that thorough inversions require that the apparent temperatures be sampled at a sufficient number of points between nadir and zenith.

Claassen, J. P.↗

Vibrational and rotational temperature measurements in a shock tube

Vibrational and rotational temperatures in nitrogen test gas relaxing behind a normal shock are measured using the emission spectra of N2(+)(1-) and N2(2+) band systems in an electric-arc driven shock tube, at a shock velocity of 6.2 km/sec. The results are compared with similar data obtained by AVCO-Everett Research Laboratory during the 1960s. The vibrational and rotational temperatures in the equilibrium region obtained in the present experiment agreed with those of AVCO, but those in the nonequilibrium region are greatly different from the AVCO results. The measured rotational temperature seems to be in nonequilibrium with the translational temperature, contradicting the two-temperature model widely used in CFD. Also, the relaxation rates for both N2(+) and N2 molecules seem to be of the same order.

Sharma, S. P.↗

An alexandrite regenerative amplifier for water vapor and temperature measurements

The Differential Absorption Lidar (DIAL) technique is a powerful method for determining meteorological parameters, but it requires high quality of the laser source: high energy, very narrow bandwidth, high wavelength stability, and spectral purity. Although many efforts have been made to improve the lasers in view of these aspects, a satisfactory solution has not been demonstrated up to now. We describe a regenerative amplifier, using a Ti:sapphire laser as master oscillator and an alexandrite laser as slave amplifier, which is expected to meet the requirements for water vapor concentration and temperature measurements.

Thro, P.-Y.↗