Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Monte Carlo Study of Feasibility of Passive Time-Coincidence Measurements for Monitoring Large Fissile Storage Arrays

Monitoring the amount of HEU in large (metric tons) storage arrays with passive time coincidence distribution measurements is complicated by a variety of effects. These include: (1) time correlated background from HEU outside the particular localized section of the storage array being monitored, (2) cosmic radiation induced fission of nearby array materials, and (3) how large a portion of the array can be monitored with a set of detectors at a particular location in the array. Such a large storage array is typically rows of 2 wide and 3 high birdcages (metal structures that maintain safe nuclear criticality spacing between stored HEU castings) separated by 2-foot-wide aisles between rows. This evaluation investigates how large an array of birdcages can be monitored by two 4x4 arrays of proton recoil scintillators. Monte Carlo simulations provided the time distribution of coincidences, multiplets (number of times n detection events occur in a time interval), and Feynman variance as a function of the length of the array. These calculations were performed for hypothetical arrays of 18 kg HEU standard Y-12 storage castings spaced 20 in apart. These types of arrays are used because the spacing between HEU castings are loosely coupled in that the castings at the ends of the arrays only interact with adjacent castings; this makes monitoring of the entire array difficult with detectors at a particular location in the array.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Noninvasive acoustic time-of-flight measurements in heated, hermetically-sealed high explosives using a convolutional neural network

In this work, we present a data-driven technique for measuring the time-of-flight through material sealed within a container. Time-of-flight measurement provides a noninvasive means of quantifying the sound speed profile within a material by transmitting an acoustic burst and then measuring the time required for the burst to arrive at an opposing receiver. In a hermetically-sealed cylindrical container, a portion of the acoustic energy propagates through the material as a bulk wave, while the remainder of the acoustic energy propagates around the container walls as guided waves. As a result, interference from the guided waves obscures the bulk arrival, inhibiting measurement of the sound speed. The technique uses a Convolutional Neural Network (CNN) to identify critical features in the measured waveforms and identify bulk wave arrivals. We demonstrate this time-of-flight measurement technique on high explosive-filled containers as they are heated from room temperature to detonation. This is a particularly challenging application for acoustic time-of-flight measurements as the high explosives have significant sound speed gradients as they undergo heating, and they lead to significant attenuation of the bulk wave, as opposed to the guided waves, which do not suffer significant attenuation. We characterize the performance of the CNN as a function of the high explosive temperature and as a function of the CNN hyperparameters. We then provide physical insight into the error trends.

47 OTHER INSTRUMENTATION↗

Probe shapes that measure time-averaged streamwise momentum and cross-stream turbulence intensity

A method and apparatus for directly measuring the time-averaged streamwise momentum in a turbulent stream use a probe which has total head response which varies as the cosine-squared of the angle of incidence. The probe has a nose with a slight indentation on its front face for providing the desired response. The method of making the probe incorporates unique design features. Another probe may be positioned in a side-by-side relationship to the first probe to provide a direct measurement of the total pressure. The difference between the two pressures yields the sum of the squares of the cross-stream components of the turbulence level.

Rossow, Vernon J.↗

Third-order correlator for measuring the time profile of petawatt laser pulses

A third-order correlator with a single-shot time window and a full dynamic range of 10{sup 8} is developed. The time contrast of radiation from the front-end system of a petawatt femtosecond laser complex measured with the correlator within time windows {+-}1 ps and {+-}100 ps was 10{sup 4} and more than 10{sup 8}, respectively. Based on the theoretical analysis of the cross-correlator operation, a number of requirements providing the optimal functioning of the cross-correlator are found. The reasons restricting the technical parameters of the correlator are discussed. (measurement of parameters of laser radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct observation of electron emission and recombination processes by time domain measurements of charge pumping current

To analyze the charge pumping (CP) sequence in detail, the source/drain electron current and the substrate hole current under the CP mode of transistors are simultaneously monitored in the time domain. Peaks are observed in both the electron and hole currents, which are, respectively, attributed to the electron emission from the interface defects and to the recombination with holes. The peak caused by the electron emission is found to consist of two components, strongly suggesting that the present time-domain measurement can enable us to resolve different kinds of interface defects. Investigating the correlation between the number of emitted and recombined electrons reveals that only one of the two components contributes to the CP current for the gate-pulse fall time from 6.25 × 10{sup −4} to 1.25 × 10{sup −2} s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional-spatial distribution measurement of electron temperature and plasma density in low temperature plasmas

A real-time measurement method for two-dimensional (2D) spatial distribution of the electron temperature and plasma density was developed. The method is based on the floating harmonic method and the real time measurement is achieved with little plasma perturbation. 2D arrays of the sensors on a 300 mm diameter wafer-shaped printed circuit board with a high speed multiplexer circuit were used. Experiments were performed in an inductive discharge under various external conditions, such as powers, gas pressures, and different gas mixing ratios. The results are consistent with theoretical prediction. Our method can measure the 2D spatial distribution of plasma parameters on a wafer-level in real-time. This method can be applied to plasma diagnostics to improve the plasma uniformity of plasma reactors for plasma processing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

Time-Reference for Measurements of Arbitrarily Shaped Pulses

This paper addresses measurements of relative timing of irregularly and differently shaped pulses (by which we mean signals that are zero beyond a finite interval). For such pulses the usual time reference points become useless: rising edges may change their slopes and shapes, and maxima might split. We propose a definition of the time reference applicable to smooth but otherwise arbitrary pulses. It is applicable to signal scaling, simplifies the covariance matrix (of parameters’ error estimates) and yields an effective analytic estimate of timing error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proceedings of the Fourth Precise Time and Time Interval Planning Meeting

The proceedings of a conference on Precise Time and Time Interval Planning are presented. The subjects discussed include the following: (1) satellite timing techniques, precision frequency sources, and very long baseline interferometry, (2) frequency stabilities and communications, and (3) very low frequency and ultrahigh frequency propagation and use. Emphasis is placed on the accuracy of time discrimination obtained with time measuring equipment and specific applications of time measurement to military operations and civilian research projects.

Acrivos, H. N.↗

Time-integrated measurements of $\gamma$ at the Tevatron and prospects

The measurement of CP-violating asymmetries and branching ratios of B {yields} DK modes allows a theoretically-clean extraction of the CKM angle {gamma}. We report recent CDF measurements with Cabibbo suppressed ({pi}{pi}, KK) or doubly Cabibbo suppressed (K{sup +}{pi}{sup -}) D decays. These measurements are performed for the first time in hadron collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved measurement of Landau-Zener tunneling in different bases

A comprehensive study of the tunneling dynamics of a Bose-Einstein condensate in a tilted periodic potential is presented. We report numerical and experimental results on time-resolved measurements of the Landau-Zener tunneling of ultracold atoms introduced by the tilt, which experimentally is realized by accelerating the lattice. The use of different protocols enables us to access the tunneling probability, numerically as well as experimentally, in two different bases, namely, the adiabatic basis and the diabatic basis. The adiabatic basis corresponds to the eigenstates of the lattice, and the diabatic one to the free-particle momentum eigenstates. Our numerical and experimental results are compared with existing two-state Landau-Zener models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous liquid level measurements with time domain reflectometry

A time domain reflectometer is considered as a closed loop, one-dimensional radar system. Applying the principle of time domain reflectometry to the detection of cryogenic liquid levels, measurements on the order of + or - 0. 3% of total liquid level probe length are possible. The time domain reflectometer liquid level measurement is independent of liquid density variations and is simple to calibrate and operate. Construction of the liquid level sensing probe is described.

Cruz, J. E.↗

Time-resolved measurements of key intermediate products during cyclopentanone pyrolysis in a shock tube

The pyrolysis of cyclopentanone, a promising biofuel candidate identified by the Department of Energy’s Co-Optima program, is investigated in this work. Time resolved measurements of carbon monoxide, ethylene, and cyclopentanone are provided to gain a detailed understanding of the unimolecular decomposition pathway of the fuel. Experiments were conducted between 1156-1312 K near 9 atm with 0.1% fuel loading balanced in argon. A strategy to report species concentration with interference is presented and the measurements obtained are crucial validation targets for the development of detailed chemical kinetic mechanisms used to predict fuel chemistry.

09 BIOMASS FUELS↗

Phase effects due to previous pulses in time-resolved Faraday rotation measurements

Time-resolved Faraday rotation measurements have proved transformative in the investigation of spin dynamics in semiconductors. In materials with spin lifetimes which are on the order of, or greater than, the laser repetition time, the collective effect of spin polarization due to the whole pump pulse train becomes important. Here, we discuss a relative phase shift which results from these spins. We derive and experimentally validate a closed-form expression which describes this phase shift and characterize it throughout parameter space. A spin lifetime measurement based on this phase shift is described, and we discuss situations in which the model used must be augmented to be applicable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An absolute instrument for determination of the speed of sound in water

An apparatus for the absolute determination of the sound speed in water based on the time-of-flight technique is described. The time measurement is realized by hardware circuits and the distance measurement by a double-beam plane-mirror interferometer. A highly accurate time chip, with a resolution of approximately 90 ps, is employed for time measurements. The acoustic path length is adjustable and can be measured directly. Two transducers are used for transmitting and receiving ultrasonic signals without reflection. The transducers are immersed in a thermostatic vessel that maintains bath temperature with high stability. The speed of sound in pure water was measured at ambient pressure and at the temperatures 308 K, 303 K, 298 K, and 293 K. The achieved measurement uncertainties are 2 mK for temperature and 0.045 m/s for speed of sound. The results are compared to data from the literature, equation of state models, and measurements by two commercial sensors in the same experiment, showing excellent agreement among them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of air on energy and rise-time spectra measured by proportional gas counter

Air exerts a negative effect on radiation detection using a gas counter because oxygen contained in air has a high electron attachment coefficient and can trap electrons from electron-ion pairs created by ionization from incident radiation in counting gas. This reduces radiation counts. The present study examined the influence of air on energy and rise-time spectra measurements using a proportional gas counter. In addition, a decompression procedure method was proposed to reduce the influence of air and its effectiveness was investigated. For the decompression procedure, the counting gas inside the gas counter was decompressed below atmospheric pressure before radiation detection. For the spectrum measurement, methane as well as various methane and air mixtures were used as the counting gas to determine the effect of air on energy and rise-time spectra. Results showed that the decompression procedure was effective for reducing or eliminating the influence of air on spectra measurement using a proportional gas counter. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The stopped-drop method: a novel setup for containment-free and time-resolved measurements

A novel setup for containment-free time-resolved experiments at a free-hanging drop is reported. Within a dead-time of 100 ms a drop of mixed reactant solutions is formed and the time evolution of a reaction can be followed from thereon by various techniques. As an example, a small-angle X-ray scattering study on the formation mechanism of EDTA-stabilized CdS both at a synchrotron and a laboratory X-ray source is presented here. While the evolution can be followed with one drop only at a synchrotron source, a stroboscopic mode with many drops is preferable for the laboratory source.

containment-free↗