High-throughput transient thermal interface testing method using time-domain thermal response
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Explore the source record for details and available documents.
Not Available
We play the role of an ice age ecologist (IAE) charged with conserving biodiversity during the climate changes accompanying the last deglaciation. We develop reserve-selection strategies for the IAE and check them against rankings based on modern data. Three reserve-selection strategies are developed. (1) Abiotic: the IAE uses no information about species–climate relationships, instead maximizing the climatic and geographic dispersion of reserves. (2) Species distribution models (SDMs): the IAE uses boosted-regression trees calibrated against pollen data and CCSM3 palaeoclimatic simulations from 21 to 15 ka bp to predict modern taxon distributions, then uses these as input to the Zonation reserve-ranking program. (3) Rank-and-regress: regression models are used to identify climatic predictors of zonation rankings. All strategies are assessed against a Zonation ranking based on modern pollen distributions. Analysis units are ecoregions and grid cells. The abiotic strategy has a negative or no correlation between predicted and actual rankings. The SDM-based strategy fares better, with a significantly positive area-corrected correlation (r= 0.474, P < 0.001) between predicted and actual rankings. Predictive ability drops when grid cells are the analysis unit (r= 0.217, P = 0.058). Predictive ability for the rank-and-regress strategy is similar to the SDM results. For the IAE, SDMs improve the predictive ability of reserve-selection strategies. However, predictive ability is limited overall, probably due to shifted realized niches during past no-analogue climates, new species interactions as species responded individually to climate change, and other environmental changes not included in the model. Twenty-first-century conservation planning also faces these challenges, and is further complicated by other anthropogenic impacts. The IAE's limited success does not preclude the use of climate scenarios and niche-based SDMs when developing adaptation strategies, but suggests that such tools offer at best only a rough guide to identifying possible areas of future conservation value.
Not Available
Purpose: The objectives of this study are to develop an magnetic resonance imaging and spectroscopy (MRI-MRS) fused phantom along with the inserts for metabolite quantification and to conduct quantitative analysis and evaluation of the layered vials of brain-mimicking solution for quality assurance (QA) performance, according to the localization sequence. Methods: The outer cylindrical phantom body is made of acrylic materials. The section other than where the inner vials are located was filled with copper sulfate and diluted with water so as to reduce the T1 relaxation time. Sodium chloride was included to provide conductivity similar to the human body. All measurements of MRI and MRS were made using a 3.0 T scanner (Achiva Tx 3.0 T; Philips Medical Systems, Netherlands). The MRI scan parameters were as follows: (1) spin echo (SE) T1-weighted image: repetition time (TR), 500ms; echo time (TE), 20ms; matrix, 256×256; field of view (FOV), 250mm; gap, 1mm; number of signal averages (NSA), 1; (2) SE T2-weighted image: TR, 2,500 ms; TE, 80 ms; matrix, 256×256; FOV, 250mm; gap, 1mm; NSA, 1; 23 slice images were obtained with slice thickness of 5mm. The water signal of each volume of interest was suppressed by variable pulse power and optimized relaxation delays (VAPOR) applied before the scan. By applying a point-resolved spectroscopy sequence, the MRS scan parameters were as follows: voxel size, 0.8×0.8×0.8 cm{sup 3}; TR, 2,000ms; TE, 35ms; NSA, 128. Results: Using the fused phantom, the results of measuring MRI factors were: geometric distortion, <2% and ±2 mm; image intensity uniformity, 83.09±1.33%; percent-signal ghosting, 0.025±0.004; low-contrast object detectability, 27.85±0.80. In addition, the signal-to-noise ratio of N-acetyl-aspartate was consistently high (42.00±5.66). Conclusion: The MRI-MRS QA factors obtained simultaneously using the phantom can facilitate evaluation of both images and spectra, and provide guidelines for obtaining MRI and MRS QA factors simultaneously. This study was supported by grant (2012-007883 and 2014R1A2A1A10050270) from the Mid-career Researcher Program through the NRF funded by Ministry of Science. In addition, this study was supported by the Industrial R&D of MOTIE/KEIT (10048997, Development of the core technology for integrated therapy devices based on real-time MRI-guided tumor tracking)
Manganese-rich oxides continue to gain interest with respect to the development of Earth-abundant options for lithium-ion cathodes. Of the unique challenges that hinder the respective performance of various classes of such materials, manganese dissolution still stands as a common theme. The work herein explores Li 3 PO 4 as a robust surface protection layer on a prototypical, Co-free, manganese-rich cathode in the way of a lithium- and manganese-rich oxide. The study highlights the critical importance of synthesis and processing in realizing optimal performance of a given surface treatment by comparing sol-gel and atomic layer deposition methods. Furthermore, cycling protocols are emphasized as a critical factor in adequately gauging the efficacy of surface protection strategies to mitigate manganese dissolution and the subsequent electrochemical consequence. Optimized Li 3 PO 4 coatings coatings on lithium- and manganese-rich cathode particles are shown to greatly mitigate capacity fade, impedance rise, pore/void formation and mechanical damage during long-term cycling.
Not provided.
Not provided.
The overarching goal of this work is to advance the capabilities of technology evaluators in evaluating the building-level baseline modeling capabilities of Energy Management and Information System (EMIS) software. Through their customer engagement platforms and products, EMIS software products have the potential to produce whole-building energy savings through multiple strategies: building system operation improvements, equipment efficiency upgrades and replacements, and inducement of behavioral change among the occupants and operations personnel. Some offerings may also automate the quantification of whole-building energy savings, relative to a baseline period, using empirical models that relate energy consumption to key influencing parameters, such as ambient weather conditions and building operation schedule. These automated baseline models can be used to streamline the whole-building measurement and verification (M&V) process, and therefore are of critical importance in the context of multi-measure whole-building focused utility efficiency programs.
During an urban wide-area incident involving the release of a biological warfare agent, the recovery/restoration effort will require extensive resources and will tax the current capabilities of the government and private contractors. In fact, resources may be so limited that decontamination by facility owners/occupants may become necessary and a simple decontamination process and material should be available for this use. One potential process for use by facility owners/occupants would be a liquid sporicidal decontaminant, such as pHamended bleach or activated-peroxide, and simple application devices. While pH-amended bleach is currently the recommended low-tech decontamination solution, a less corrosive and toxic decontaminant is desirable. The objective of this project is to provide an operational assessment of an alternative to chlorine bleach for low-tech decontamination applications activated hydrogen peroxide. This report provides the methods and results for activatedperoxide evaluation experiments. The results suggest that the efficacy of an activated-peroxide decontaminant is similar to pH-amended bleach on many common materials.
Nuclear materials are an essential aspect of nuclear engineering. While great effort is spent on designing more advanced reactors or enhancing a reactor’s safety, materials have been the bottleneck of most new developments. The designs of new reactor concepts are driven by neutronic and thermodynamic aspects, leading to unusual coolants (liquid metal, liquid salt, gases), higher temperatures, and higher radiation doses than conventional light water reactors have. However, any (nuclear) engineering design must consider the materials used in the anticipated application in order to ever be realized. Designs which may look easy, simple and efficient considering thermodynamics or neutronic aspects can show their true difficulty in the materials area, which then prevents them from being deployed. In turn, the materials available are influencing the neutronic and thermodynamic designs and therefore must be considered from the beginning, requiring close collaborations between different aspects of nuclear engineering. If a particular design requires new materials, the licensing of the reactor must be considered, but licensing can be a costly and time consuming process that results in long lead times to realize true materials innovation.
This is a technical report from the lead institution – University of Utah, Kahlert School of Computing – funded under the Department of Energy, Office of Science, Office of Advanced Scientific Computing Research under award number DE-SC0022252. We summarize our work done over the three years of funding received. The relevant papers and software have already been uploaded at the DOE site.
Explore the source record for details and available documents.