Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Switched systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Novel, Middle and Long Wave Infrared Laser Sources For Accelerator Applications

The main accomplishment during Years 2020-2024 of the DOE Accelerator Stewardship Program is proof-of-principle demonstration of amplification of an ultrashort 10 µm seed pulse in a multiatmosphere CO 2 laser optically pumped by nanosecond pulses of either a ~4.3 µm Fe:ZnSe laser or a 2.8 µm electro-optically (EO) Q-switched Er: Laser. This has been accomplished at the UCLA Neptune Laboratory by using about 100 mJ, ~100 ns long pulses generated by the pump laser built for this purpose by the UAB team. Implementation of EO Q-switching regime in the solid-state Er:laser system made possible nanosecond synchronization between the pump pulse and the 0.5 ps seed pulse produced by a commercial Ti:sapphire laser based mid-IR OPA/DFG. The injection mode-locking regime realized in a compact Mult atmosphere 3 Hz CO 2 -He regenerative amplifier enabled generation of a train of ultrashort pulses separated by the cavity round-trip time of ~3.2 ns. The measured gain lifetime of ~1 µs at a total pressure of ~12-15 atm indicates that lifetime of the upper laser level is a critical limiting factor in designing high-pressure CO 2 amplifiers. A single picosecond 10 mm pulse with an energy 0.1-0.2 mJ was extracted from the amplifier’s cavity using an ultrafast Ge semiconductor switch whose reflectivity was photo-induced by a femtosecond 800 nm pulse. For direct amplification regime, nonlinear absorption in Ge at 10 mm at GW/cm 2 intensities limited the extracted energy. Therefore, the generated energy could be further increased by minimizing losses in the switch and optimizing the cavity mode size. Based on the obtained data in collaboration with BNL colleagues, we have designed a high-pressure CO 2 amplifier to be used as a preamplifier for the future experiments at the ATF BNL. The latter work is the subject of funding availability.

60 APPLIED LIFE SCIENCES↗

Inverter Controls for Smooth Transition Operation and Voltage Balancing of Networked Microgrids

With increasing penetrations of distributed energy resources (DERs), researchers have extensively studied the formation and networking of microgrids to improve reliability during distribution system outages. However, these operations might require DERs in the microgrids to switch between grid-following (GFL) and grid-forming (GFM) modes of operation. A smooth transition between the operation modes should be ensured to have a stable system operation and to avoid nuisance tripping. Additionally, as we network microgrids, inverter control schemes with voltage-balancing controls are needed for unbalanced distribution networks. This paper presents the design of a GFM and GFL capable inverter control scheme for reliable operation in networked microgrids with mechanisms for 1) smooth transition between the GFL and GFM modes, and 2) negative sequence voltage control for voltage balancing. Using electromagnetic transient (EMT) simulations, the control scheme is first tested on a simple two-source power system using a digital real-time simulator. Next, a real-world distribution feeder with unbalanced loading and multiple DERs is used to demonstrate stable operation during the networking of microgrids with voltage balance support.

distributed energy resources↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guest Editorial: Planning and operation of resilient distribution system for integrated multi-energy

Resilience is the ability of power systems to prepare for and adapt to low-probability, high-impact incidents and withstand and recover rapidly from disruptions. With the ageing of electricity distribution infrastructure and increasing threats of weather-related incidents and natural disasters, the need to effectively enhance the resilience of the electricity distribution system has become urgent and has attracted worldwide attention. Although there are an increasing number of publications related to enhancing resilience strategies, resilience is an emerging concept in power systems. Existing practices are mostly focused on deploying distributed energy resources (DERs) and microgrids, hardening the existing infrastructures and building redundant capacities. However, from a broader perspective, resilience enhancement of power distribution system is a systematic engineering, involving long-term system planning and upgrading (e.g., deployment of smart grid technologies and intelligent switches), short-term proactive scheduling, real-time robust and resilient control of DERs, and post-event restoration and recovery strategies. Based on this point, this Special Issue in IET Energy System Integration focuses on soliciting the most recent and original technologies, scheduling and control strategies for improving the resilience of power distribution system. Eight papers are presented in this Special Issue, covering various aspects related to resilience enhancement of power distribution system, including fault-tolerant frequency measurement, robust scheduling of integrated electricity and district heating systems, robust control of DERs, efficient methods for safety verification as well as novel graph theory-based approach to restore the distribution systems after multiple simultaneous faults. A brief introduction of these 8 papers is provided below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Containers on Switches: A Cluster School Experience

Network switches, such as those from Arista and Mellanox, often have underutilized computational resources in the form of built-in processors and memory. By leveraging these untapped resources, we can optimize functionality and efficiency of computational cluster networks. Our research focuses on deploying containers directly onto these switches to execute various auxiliary tasks ranging from metric logging to system-wide management via post-boot configuration. By doing so, we can significantly enchance the capabilities of the cluster without the need for additional dedicated hardware. Our research involved five distinct scenarios where switch utilization could have a profound impact on HPC Clusters: run cloud-init services via link-local connection; configuring a Telegraf container to export metrics; deploying a caching proxy; creating a reconfigurable IPv6 DHCP/DNS provider for VLAN; and implementing a client detection with Magellan discovery. These scenarios were containerized with podman and docker, and tested both physically on the switch virtually on a QEMU VM both running SONiC OS. Testing and findings indicate that network switches can indeed be used for these scenarios. They offer a wide range of possibilities beyond these applications. They run as expected as containers on the switches, and although there were some minor issues, work-arounds were implemented. Overall, this is a positive result that can be further explored with more scenarios.

97 MATHEMATICS AND COMPUTING↗

Nanoscale imaging of He-ion irradiation effects on amorphous TaO x toward electroforming-free neuromorphic functions

Resistive switching in thin films has been widely studied in a broad range of materials. Yet, the mechanisms behind electroresistive switching have been persistently difficult to decipher and control, in part due to their non-equilibrium nature. Here, we demonstrate new experimental approaches that can probe resistive switching phenomena, utilizing amorphous TaO x as a model material system. Specifically, we applied scanning microwave impedance microscopy and cathodoluminescence (CL) microscopy as direct probes of conductance and electronic structure, respectively. These methods provide direct evidence of the electronic state of TaO x despite its amorphous nature. For example, CL identifies characteristic impurity levels in TaO x , in agreement with first principles calculations. We applied these methods to investigate He-ion-beam irradiation as a path to activate conductivity of materials and enable electroforming-free control over resistive switching. However, we find that even though He-ions begin to modify the nature of bonds even at the lowest doses, the films' conductive properties exhibit remarkable stability with large displacement damage and they are driven to metallic states only at the limit of structural decomposition. Finally, we show that electroforming in a nanoscale junction can be carried out with a dissipated power of <20 nW, a much smaller value compared to earlier studies and one that minimizes irreversible structural modifications of the films. Importantly, the multimodal approach described here provides a new framework toward the theory/experiment guided design and optimization of electroresistive materials.

36 MATERIALS SCIENCE↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the cosmic microwave background with unprecedented sensitivity. This will require an order of magnitude increase in the 100-mK detector count, which, in turn, increases the demands on the readout system. The CMB-S4 readout will use time-division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuitry and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. Here, we present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

47 OTHER INSTRUMENTATION↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

A 50-kW Bidirectional Step-up / Step-down DC/DC Oak Ridge Converter for Wireless Charger Applications

This study presents a novel bidirectional concept by using Oak Ridge Converter (ORC) for wireless energy conversion (WEC) technologies such as wireless electric vehicle (EV) chargers, wireless mobile or energy storage systems (MESS / ESS), etc. The presented system can be deployed in a bidirectional wireless power transfer (WPT) structure for different input voltages by using two different operating frequencies. The proposed concept here achieves zero voltage switching (ZVS) in during step-up and step-down configurations. The system overall theoretical design and experimental test results are presented for 50 kW power transfer in both bidirectional operations modes. The laboratory demonstration of the system is presented for the three-phase bidirectional system with 6 inches of airgap between the coils and output of 560 VDC with 95.4% dc-to-dc efficiency.

Asa, Erdem↗

SoS-SDQN: System of Systems Software-defined Quantum Networking

Quantum networks are needed for quantum domain applications that may run across different network deployments - point-to-point, multi-node networks, and possibly across inter-domain quantum networks, like the quantum internet. Unlike classical computing networks, quantum networks involve heterogeneous systems nodes that currently require local and manual control. This needs a unified control approach to help them integrate, work seamlessly, and have global knowledge. Software-defined Networking (SDN) has been successfully leveraged in classical networking for seamless and software-driven control of network infrastructure and packet switching, but not in management of quantum network applications across heterogeneous systems. In this paper, we review the current state of the art and present early developments of a System-of-Systems Software-defined Quantum Networking architecture (SoS-SDQN), a generic architecture that supports software-driven quantum network experiments across heterogeneous quantum systems. The architecture modifies the generic SDN to address the domain requirements of quantum networks and proposes a multilevel SDQN to provide a global view of network status, running applications, and control of incorporated heterogeneous quantum systems. We also design and implement a SoS SouthBound Quantum Interface (SoS-SBQI), a quantum infrastructure protocol that abstracts automation of applications across the network.

Alnajjar, Anees [ORNL] (ORCID:0000000237101601)↗

Performance Study of CXL Memory Topology

This paper presents a comprehensive evaluation of the performance impact of various Compute Express Link (CXL) memory topologies, with a particular emphasis on CXL switches, in the context of High- Performance Computing (HPC) and Large Language Model (LLM) inference workloads. Our study unveils significant performance variations across different topologies, demonstrating that certain configurations yield superior performance for specific workloads. These findings underscore the critical importance of tailored topol- ogy selection in optimizing system performance. Additionally, we address the inherent challenges associated with integrating CXL switches, including overhead considerations and routing complex- ities. Our research highlights the necessity for thorough evalua- tion methodologies to fully leverage CXL technology’s potential in contemporary computing environments. These insights provide valuable guidance for system architects and data center operators in designing and optimizing CXL-based infrastructures for diverse workload requirements.

CXL, memory, Artificial Intelligence (AI), HPC↗

Control of SiC Based Integrated DC-DC Powertrain Charger for Electric Vehicles

In this paper, an automated controller for an integrated, reconfigurable dc-dc converter for plugin electric vehicles (EVs) is presented. The integrated converter combines both an interleaved boost converter and dual active bridge (DAB) converter, sharing magnetics and switching devices. The converter switches between operating modes using the existing battery management system (BMS) contactors. The integrated converter operates in isolated DAB mode during battery charging operation. During traction operation, the integrated converter is operated in interleaved boost mode for heavy load and DAB mode during light load, high voltage operation. An online transition algorithm is used to transition from interleaved boost mode to DAB mode with minimal bus distortion. The automated controller selects the operating mode and inverter bus voltage at different torque-speed conditions to get maximum overall traction drive efficiency. An experimental prototype of the integrated converter demonstrates the automated controller functionality.

Anwar, Saeed↗

UrbanScaping: Community Spatial Data Visualization & Analytics

Evaluating the electrification potential of buildings through retrofitting is crucial for reducing carbon emissions and the carbon footprint of built environments. This study leverages the Automatic Building Energy Modeling (AutoBEM) software, integrating the Model America database to create an urban context-based spatial analysis platform for community engagement and development. We selected Camp Hill Borough, PA, as a case study to analyze building-specific energy performance and evaluate the electrification potential of each building by switching to different Heating, Ventilation, and Air Conditioning (HVAC) systems and measurement components. The simulation results generated by the workflow provide retrofitting suggestions to help mitigate the carbon footprint as well as energy saving statistics of buildings. Additionally, the developed web-based interface serves as a community engagement platform, allowing residents to provide feedback and further develop interactive communication protocols. The outcomes of this project offer a baseline for community electrification planning and contribute to the design of low-carbon communities.

Chowdhury, Shovan [ORNL]↗

Exploring OpenSNAPI Use Cases and Evolving Requirements [Slides]

Emerging system architectures are rapidly transforming in order to meet shifting requirements. Motivated by expanding data volumes, energy efficiency concerns, and the omnipresent need to improve performance, architectures are increasingly adopting a data-centric approach. At the core of this concept is the goal of minimizing data motion and instead processing data in-situ to the greatest degree possible. Therefore, data-centric designs, in contrast to conventional CPU-centric models, typically distribute compute capabilities throughout the architecture. As part of this paradigm shift, a novel class of devices known as data processing units (DPUs), alongside CPUs and GPUs, are quickly forming a third pillar of data-centric systems. These devices, which include smart network adapters and switches, seek to offload computation on data at the network edge as well as in-flight within the network fabric. The Open Smart Network API (OpenSNAPI) project seeks to develop a unified API for DPU devices. In our previous talks, we introduced the OpenSNAPI project and detailed our investigations regarding the viability of offloading compute intensive kernels to BlueField DPUs. In contrast, in this talk we detail our efforts to offload application-level file I/O to the DPU. We also discuss plans and early efforts to explore in-network compute capabilities. Finally, we describe our observations with respect to the evolving design of OpenSNAPI.

97 MATHEMATICS AND COMPUTING↗

RHIC Recovery Review Report [See also: RHIC Recovery Review - Hybrid Meeting (11/28/2023) - Indico.bnl.gov]

Just after 12:30 PM on August 1, 2023, the RHIC superconducting magnet quench system triggered and consequently the energy dump resistors were switched into the blue ring quad and dipole circuits and the interaction region DX dipole heaters were switched on. This was a spurious trip (there was no actual quench) and was not unusual as the outdoor summer temperature often caused the quench detectors to cause such trips. The collider control room notified the on-duty cryogenics technical staff of the quench trip. A short time later building 1004B cryogenic low-helium and valve box insulation vacuum failure alarms were observed. The cryogenics technical staff observed the cryo-relief line from the blue ring valve box was exhausting helium outside the building.

43 PARTICLE ACCELERATORS↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗

Optimizing connectivity in reconfigurable networks

A method may include determining whether the topology of a network includes a direct path between a first endpoint and a second endpoint in the network. A direct path may be used to send a first type of traffic from the first endpoint to the second endpoint whereas any currently available path may be used to send a second type of traffic from the first endpoint to the second endpoint. If the topology of the network does not include a direct path, the first type of traffic may be buffered at the first endpoint until the topology of the network is reconfigured to include the direct path. The topology of the network may be reconfigured when at least one switch in the network reconfigures, for example, by switching from one interconnection to another interconnection pattern. Related systems and articles of manufacture are also provided.

Mellette, William↗

Deterministic Current–Induced Perpendicular Switching in Epitaxial Co/Pt Layers without an External Field

Current–induced spin–orbit torques (SOTs) have emerged as a powerful tool to control magnetic elements and non–uniform magnetic textures such as domain walls and skyrmions. SOT–induced switching of perpendicular magnetization generally requires an external field to break the rotational symmetry of the spin–orbit effective fields responsible for the deterministic reversal. The proposed mechanisms to eliminate this requirement often rely on complex multilayer structures that necessitate laborious optimization in the material and spin transport properties, making them less attractive for applications. Herein, current–induced, external field–free switching of an epitaxial MgO/Pt/Co trilayer with an extremely large perpendicular anisotropy in excess of 3 Tesla is reported. It is found that switching occurs due to the interplay of strong SOTs, local anisotropy fluctuations, and the Dzyaloshinkii–Moriya interaction inherent to this epitaxial system. Finally, given that these layers constitute the base stack of a magnetic tunnel junction, this switching mechanism offers the most technologically viable path toward devices such as field–free SOT–based magnetic random–access memories.

36 MATERIALS SCIENCE↗