Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Semiclassical analysis of the Efimov energy spectrum in the unitary limit

We demonstrate that the (s-wave) geometric spectrum of the Efimov energy levels in the unitary limit is generated by the radial motion of a primitive periodic orbit (and its harmonics) of the corresponding classical system. The action of the primitive orbit depends logarithmically on the energy. It is shown to be consistent with an inverse-squared radial potential with a lower cutoff radius. The lowest-order WKB quantization, including the Langer correction, is shown to reproduce the geometric scaling of the energy spectrum. The (WKB) mean-squared radii of the Efimov states scale geometrically like the inverse of their energies. The WKB wave functions, regularized near the classical turning point by Langer's generalized connection formula, are practically indistinguishable from the exact wave functions even for the lowest (n=0) state, apart from a tiny shift of its zeros that remains constant for large n.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High order perturbative corrections to the determination of |V{sub ub}| from the P{sub +} spectrum in B{yields}X{sub u}l{nu}{sub l}

We investigate the behavior of the perturbative relation between the photon energy spectrum in B{yields}X{sub s}{gamma} and the hadronic P{sub +} spectrum in semileptonic B{yields}X{sub u}l{nu} decay at high orders in perturbation theory in the 'large-{beta}{sub 0}' limit, in which only terms of order {alpha}{sub s}{sup n}{beta}{sub 0}{sup n-1} are retained. The leading renormalon in the weight function W({delta},P{sub {gamma}}) relating the two spectra is confirmed to be at u=1/2, corresponding to nonperturbative corrections at O({lambda}{sub QCD}/m{sub b}). We show that the P{sub {gamma}} dependent pieces of the weight function have no infrared renormalons in this limit, and so the factorial growth in perturbation theory arises solely from the constant terms. We find no numerical enhancement of leading logarithms, suggesting that fixed-order perturbation theory is more appropriate than a leading-log resummation for the extraction of |V{sub ub}|. The importance of various terms in the expansion of the weight function is studied using a model for the B{yields}X{sub s}{gamma} photon spectrum. Our analysis suggests that higher order perturbative corrections do not introduce a significant uncertainty in the extraction of |V{sub ub}|.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum chaos, integrability, and late times in the Krylov basis

Quantum chaotic systems are conjectured to display a spectrum whose fine-grained features (gaps and correlations) are well described by random matrix theory (RMT). We propose and develop a complementary version of this conjecture: quantum chaotic systems display a Lanczos spectrum whose local means and covariances are well described by RMT. To support this proposal, we first demonstrate its validity in examples of chaotic and integrable systems. We then show that for Haar-random initial states in RMTs the mean and covariance of the Lanczos spectrum suffice to produce the full long-time behavior of general survival probabilities including the spectral form factor, as well as the spread complexity. In addition, for initial states with continuous overlap with energy eigenstates, we analytically find the long-time averages of the probabilities of Krylov basis elements in terms of the mean Lanczos spectrum. This analysis suggests a notion of eigenstate complexity, the statistics of which differentiate integrable systems and classes of quantum chaos. Lastly, we clarify the relation between spread complexity and the universality classes of RMT by exploring various values of the Dyson index and Poisson distributed spectra.

Combinatorics↗

Measurements of Impurity Transport Due to Drift-Wave Turbulence in a Toroidal Plasma

The first direct measurements of an impurity particle flux driven by drift-wave turbulence in a toroidal magnetized plasma are reported. The correlation between the impurity density and radial velocity fluctuations is measured using ion Doppler spectroscopy. The small, very fast radial velocity fluctuation is resolved with the aid of a new linearized spectrum correlation analysis method that rejects uncorrelated noise as the sample size increases. The measured C 2+ turbulent impurity flux in the edge of the plasma is directed inward and is consistent with impurity density measurements. This is also the first direct evidence for fluctuation-induced transport due to trapped-electron-mode turbulence in reversed field pinch plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward Practical Federal Spectrum Sharing for Advanced Wireless Technologies

Wireless communications have become critical to modern society as the foundation of vital services, business interactions, and social connections. As technology develops and new scenarios emerge, wireless communications become increasingly entrenched as a foundation for modern life. The materialization of 5G has been especially impactful as an enabler for a wide range of new scenarios and increased dependence. With increasing demand for wireless communications comes increasing demand for the radio frequency (RF) spectrum necessary to support these communications. This spectrum demand, largely driven by desire to realize ubiquitous 5G networks, both public and private, is currently driving a reconsideration of spectrum assignments and forcing legacy users of spectrum to update their use of spectrum. As one of the largest legacy users of spectrum, the U.S. Government (USG) is particularly impacted by the increasing demand for spectrum for non USG use. Unfortunately, there is no clear pathway for U.S. federal agencies to modernize their spectrum use and instead these agencies are forced to simply react to spectrum repurposing driven by overwhelming demand. Here we present preliminary work toward a roadmap for federal agencies to modernize their spectrum use through practical analysis and leveraging emerging spectrum sharing (SS) technologies. This effort utilizes the example of DOE spectrum use in the context of National Telecommunications and Information Administration (NTIA) and Federal Communications Commission (FCC) repurposing to examine the factors that must be considered to facilitate spectrum sharing by federal agencies. Furthermore, this work provides an initial survey of the SS models and SS technologies of highest relevance to federal use. We particularly examine the emerging capabilities of 5G itself to enable SS and unlicensed access through transformative capabilities such as new radio unlicensed (NR-U). This work is a step toward translating the large body of academic discussion on SS into a practical roadmap for federal agencies.

5G↗

Optimal Bandwidth for Multitaper Spectrum Estimation

A systematic method for bandwidth parameter selection is desired for Thomson multitaper spectrum estimation. We give a method for determining the optimal bandwidth based on a mean squared error (MSE) criterion. When the true spectrum has a second-order Taylor series expansion, one can express quadratic local bias as a function of the curvature of the spectrum, which can be estimated by using a simple spline approximation. This is combined with a variance estimate, obtained by jackknifing over individual spectrum estimates, to produce an estimated MSE for the log spectrum estimate for each choice of time-bandwidth product. The bandwidth that minimizes the estimated MSE then gives the desired spectrum estimate. Additionally, the bandwidth obtained using our method is also optimal for cepstrum estimates. We give an example of a damped oscillatory (Lorentzian) process in which the approximate optimal bandwidth can be written as a function of the damping parameter. Furthermore, the true optimal bandwidth agrees well with that given by minimizing estimated the MSE in these examples.

97 MATHEMATICS AND COMPUTING↗

Tailoring Thermal and Mechanical Performance Through Multimaterial Laser Powder Directed Energy Deposition of Copper and 17-4PH Stainless Steel

This study investigates the additive manufacturing (AM) processing, microstructural evolution, and resulting mechanical and thermal properties of multimaterial components combining 17-4PH stainless steel and pure copper (Cu) fabricated via laser powder directed energy deposition (LP-DED). Conventional tooling steels exhibit limited thermal conductivity, significantly constraining production throughput in high-volume processes. Incorporating Cu, with its superior thermal conductivity, could significantly enhance tool performance, though Cu and steel present metallurgical incompatibilities when processed via AM. A systematic investigation was conducted across compositions ranging from 0 to 100 wt% Cu, revealing critical thresholds influencing solidification behavior, defect formation, microstructure, hardness, and thermal transport. Optical microscopy, electron backscatter diffraction (EBSD), hardness testing, and thermal conductivity measurements provided comprehensive process–structure–property correlations. Severe hot cracking occurred at low-Cu contents (6–25 wt%), aligning generally well with crack susceptibility modeling, with an unexpected discrepancy at 25 wt%. Porosity remained low (≥99% dense) throughout the compositional spectrum. EBSD analysis revealed a transformation from columnar martensitic structures at low-Cu contents to equiaxed FCC Cu-dominated structures at higher Cu concentrations, highlighting the complex microstructural transitions driven by Cu-induced changes in solidification and phase stability. Hardness decreased from 330 HV (pure 17-4PH) to 62 HV (pure Cu), consistent with microstructural changes. Concurrently, thermal conductivity improved substantially from 13.5 W/m K to 367.9 W/m K, emphasizing Cu’s dominant role in thermal transport. The findings highlight the feasibility of leveraging compositional gradients between 17-4PH and Cu to achieve tailored tooling with optimized thermal and mechanical performance.

17-4PH↗

Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology

Purpose: Iterative reconstruction (IR) reduces noise, thereby allowing dose reduction in computed tomography (CT) while maintaining comparable image quality to filtered back-projection (FBP). This study sought to characterize image quality metrics, delineation, dosimetric assessment, and other aspects necessary to integrate IR into treatment planning. Methods: CT images (Brilliance Big Bore v3.6, Philips Healthcare) were acquired of several phantoms using 120 kVp and 25–800 mAs. IR was applied at levels corresponding to noise reduction of 0.89–0.55 with respect to FBP. Noise power spectrum (NPS) analysis was used to characterize noise magnitude and texture. CT to electron density (CT-ED) curves were generated over all IR levels. Uniformity as well as spatial and low contrast resolution were quantified using a CATPHAN phantom. Task specific modulation transfer functions (MTF{sub task}) were developed to characterize spatial frequency across objects of varied contrast. A prospective dose reduction study was conducted for 14 patients undergoing interfraction CT scans for high-dose rate brachytherapy. Three physicians performed image quality assessment using a six-point grading scale between the normal-dose FBP (reference), low-dose FBP, and low-dose IR scans for the following metrics: image noise, detectability of the vaginal cuff/bladder interface, spatial resolution, texture, segmentation confidence, and overall image quality. Contouring differences between FBP and IR were quantified for the bladder and rectum via overlap indices (OI) and Dice similarity coefficients (DSC). Line profile and region of interest analyses quantified noise and boundary changes. For two subjects, the impact of IR on external beam dose calculation was assessed via gamma analysis and changes in digitally reconstructed radiographs (DRRs) were quantified. Results: NPS showed large reduction in noise magnitude (50%), and a slight spatial frequency shift (∼0.1 mm{sup −1}) with application of IR at L6. No appreciable changes were observed for CT-ED curves between FBP and IR levels [maximum difference ∼13 HU for bone (∼1% difference)]. For uniformity, differences were ∼1 HU between FBP and IR. Spatial resolution was well conserved; the largest MTF{sub task} decrease between FBP and IR levels was 0.08 A.U. No notable changes in low-contrast detectability were observed and CNR increased substantially with IR. For the patient study, qualitative image grading showed low-dose IR was equivalent to or slightly worse than normal dose FBP, and is superior to low-dose FBP (p < 0.001 for noise), although these did not translate to differences in CT number, contouring ability, or dose calculation. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using the most aggressive IR level [−1.2 ± 4.9 HU (range: −17.6–12.5 HU)]. No clinically significant contour differences were found between IR and FBP, with OIs and DSCs ranging from 0.85 to 0.95. Negligible changes in dose calculation were observed. DRRs preserved anatomical detail with <2% difference in intensity from FBP combined with aggressive IRL6. Conclusions: These results support integrating IR into treatment planning. While slight degradation in edges and shift in texture were observed in phantom, patient results show qualitative image grading, contouring ability, and dosimetric parameters were not adversely affected.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-06: Prospective Patient Evaluation of Iterative Reconstruction in Radiation Oncology

Purpose: This work incorporates iterative reconstruction (IR) into a dose reduction study to characterize image quality metrics, delineation, and dosimetric assessment, with the goal of reducing imaging dose in Radiation Oncology. Methods: Three-dimensional noise power spectrum (NPS) analysis characterized noise magnitude/texture (120 kVp, 50–200 mAs, IR levels 1–6 yielding noise reduction of 0.89–0.55 compared to filtered backprojection (FBP)). Task-specific Modulation Transfer Functions (MTFtask) were characterized across varied subject contrasts. A prospective dose reduction study (500 to 150 mAs) was conducted for 12 patients (43 inter-fraction CTs) for high-dose rate brachytherapy. Three physicians performed qualitative image assessment between full-dose FBP (FD-FBP, 500 mAs), low-dose FBP (LD-FBP, 150–250 mAs), and low-dose IRL5-6 (LD-IR) scans for image noise, cuff/bladder interface detectability, spatial resolution, texture, and segmentation confidence. Comparisons between LD-FBP and LD-IR were conducted for the following metrics: delineation (bladder and rectum evaluated via overlap indices (OI) and Dice similarity coefficients (DSC)), noise, boundary changes, dose calculation, and digitally reconstructed radiographs (DRRs). Results: NPS showed ∼50% reduction in noise magnitude and ∼0.1 1/mm spatial frequency shift with IRL6. The largest MTFtask decrease between FBP and IR was 0.08 A.U. Qualitative patient image evaluation revealed LD-IR was equivalent or slightly worse than FD-FBP, and superior to LD-FBP for all metrics except low contrast interface and texture. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using IRL6 (−1.2 ± 4.9 HU (range: −17.6 – 12.5 HU)). No significant contour differences (OIs and DSCs = 0.85 – 0.95) and dose calculation discrepancy (<0.02%) were observed. DRRs preserved anatomical detail and demonstrated <2% difference in intensity between LD-FBP and LD-IRL6. Conclusion: While phantom analysis showed slight noise texture differences with IR, patient results revealed that image quality, contouring ability, and dosimetric parameters were not adversely affected, thus support integrating IR into treatment planning. Research supported in part by a grant from Philips HealthCare.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-04: How Iterative Reconstruction Algorithms Affect the NPS of CT Images

Purpose: To evaluate how the third generation model based iterative reconstruction (MBIR) compares with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASiR), and the second generation MBIR based on noise power spectrum (NPS) analysis over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP515 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 19mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 0.984 pitch and reconstructed thickness 2.5mm (VEO3.0: Abd/Pelvis with Texture and NR05). At each CTDIvol level, 10 repeated scans were acquired for achieving sufficient data sampling. The images were reconstructed using Standard kernel with FBP; 20%, 40% and 70% ASiR; and two versions of MBIR (VEO2.0 and 3.0). For evaluating the effect of the ROI spatial location to the Result of NPS, 4 ROI groups were categorized based on their distances from the center of the phantom. Results: VEO3.0 performed inferiorly comparing to VEO2.0 over all dose levels. On the other hand, at low dose levels (less than 3 mGy), it clearly outperformed ASiR and FBP, in NPS values. Therefore, the lower the dose level, the relative performance of MBIR improves. However, the shapes of the NPS show substantial differences in horizontal and vertical sampling dimensions. These differences may determine the characteristics of the noise/texture features in images, and hence, play an important role in image interpretation. Conclusion: The third generation MBIR did not improve over the second generation MBIR in term of NPS analysis. The overall performance of both versions of MBIR improved as compared to other reconstruction algorithms when dose was reduced. The shapes of the NPS curves provided additional value for future characterization of the image noise/texture features.

60 APPLIED LIFE SCIENCES↗

Hydrothermal Synthesis and Characterization of a New Strandberg-type Diphosphopentamolybdate (C{sub 6}N{sub 3}H{sub 18}){sub 2}[P{sub 2}Mo{sub 5}O{sub 23}] · 6H{sub 2}O

An inorganic-organic hybrid material formulated as (C{sub 6}N{sub 3}H{sub 18}){sub 2}[P{sub 2}Mo{sub 5}O{sub 23}] · 6H{sub 2}O, has been hydrothermally synthesized and characterized by single crystal X-ray diffraction technique, IR spectrum, thermogravimetric analysis and UV-visible spectroscopy. The structure consists of diphosphopentamolybdate Strandberg type polyoxoanions [P{sub 2}Mo{sub 5}O{sub 23}]{sup 6–}, protonated 1-(2-aminoethyl)piperazine cations and six crystallization water molecules. These anions are connected with the organic amine through hydrogen bonding interactions between the hydrogen atoms of the organic molecules and the oxygen atoms of the polyoxoanion and water molecules which generate a three-dimensional network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging and microanalysis of thin ionomer layers by scanning transmission electron microscopy

Improved conditions for imaging and spectroscopic mapping of thin perfluorosulfonic acid (PFSA) ionomer layers in fuel cell electrodes by scanning transmission electron microscopy (STEM) have been investigated. These conditions are first identified on model systems of Nafion ionomer-coated nanostructured thin films and nanoporous Si. The optimized conditions are then applied in a quantitative study of the ionomer through-layer loading for two typical electrode catalyst coatings using electron energy loss and energy dispersive X-ray spectroscopy in the transmission electron microscope. The e-beam induced damage to the perfluorosulfonic acid (PFSA) ionomer is quantified by following the fluorine mass loss with electron exposure and is then mitigated by a few orders of magnitude using cryogenic specimen cooling and a higher incident electron voltage. Multivariate statistical analysis is also applied to the analysis of spectrum images for data denoising and unbiased separation of independent components related to the catalyst, ionomer, and support.

Cullen, David A↗

Cathodoluminescence Spectrum Imaging Software [SWR-11-08]

The software developed for spectrum imaging is applied to the analysis of the spectrum series generated by our cathodoluminescence instrumentation. This software provides advanced processing capabilities s such: reconstruction of photon intensity (resolved in energy) and photon energy maps, extraction of the spectrum from selected areas, quantitative imaging mode, pixel-to-pixel correlation spectrum line scans, ASCII, output, filling routines, drift correction, etc.

Romero, ManuelJ.↗

Concerning the Spatial Heterodyne Spectrometer

A modified Spatial Heterodyne Spectrometer (SHS) is used for measuring atomic emission spectra with high resolution. This device is basically a Fourier Transform Spectrometer, but the Fourier transform is taken in the directions perpendicular to the optical propagation and heterodyned around one preset wavelength. In recent descriptions of this device, one specific phenomenon - the tilt of the energy front of wave packets when diffracted from a grating - was neglected. This led to an overestimate of the resolving power of this spectrograph, especially in situations when the coherence length of the radiation under test is in the order of the effective aperture of the device. In conclusion, the limits of usability are shown here together with some measurements of known spectral lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gap-filled meteorological data (2011-2020) and modeled potential evapotranspiration data from the KCOMTCRE2 WeatherUnderground weather station, from the East River Watershed, Colorado

This dataset is a gap-filled meteorological dataset (years 2011-2020) that includes modeled potential evapotranspiration from a station near the pumphouse on the East River (KCOMTCRE2 WeatherUnderground ) near the top of the ridge at the Pumphouse PLM wells. These datasets are useful as model inputs. The KOMTCRE2 station is located on Mt. Crested Butte in Colorado. More information can be found at: https://www.wunderground.com/dashboard/pws/KCOMTCRE2/table/2020-12-7/2020-12-7/daily. The purpose of this dataset is to use as input to hydrological and flow-reactive transport models as meteorological forcing. One attached file includes metadata files with definitions for all variables and units. Subsequent files include the same time series dataset, but aggregated and gap-filled at different time-stamp intervals. These include 5 minute time-series, 15 minute time-series, 30 minute time-series, 1 hour time-series, daily time-series, and hourly and daily modeled evapotranspiration.

54 ENVIRONMENTAL SCIENCES↗

New Routes for the Production of Fission Products and Their Separation from the Source Material for the Development of Realistic Nuclear Forensic Debris

In order to fully characterize the NIF neutron spectrum, SAND-II-SNL software was requested/received from the Radiation Safety Information Computational Center. The software is designed to determine the neutron energy spectrum through analysis of experimental activation data. However, given that the source code was developed in Sparcstation 10, it is not compatible with current version of FORTRAN. Accounts have been established through the Lawrence Livermore National Laboratory’s High Performance Computing in order to access different compiles for FORTRAN (e.g. pgf77, pgf90). Additionally, several of the subroutines included in the SAND-II-SNL package have required debugging efforts to allow for proper compiling of the code.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗