Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Small object detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

UNBURNED MATERIAL IN THE EJECTA OF TYPE Ia SUPERNOVAE

The presence of unburned material in the ejecta of normal Type Ia supernovae (SNe Ia) is investigated using early-time spectroscopy obtained by the Carnegie Supernova Project. The tell-tale signature of pristine material from a C+O white dwarf progenitor star is the presence of carbon, as oxygen is also a product of carbon burning. The most prominent carbon lines in optical spectra of SNe Ia are expected to arise from C II. We find that at least 30% of the objects in the sample show an absorption at Almost-Equal-To 6300 A which is attributed to C II {lambda}6580. An alternative identification of this absorption as H{alpha} is considered to be unlikely. These findings imply a larger incidence of carbon in SNe Ia ejecta than previously noted. We show how observational biases and physical conditions may hide the presence of weak C II lines, and account for the scarcity of previous carbon detections in the literature. This relatively large frequency of carbon detections has crucial implications on our understanding of the explosive process. Furthermore, the identification of the 6300 A absorptions as carbon would imply that unburned material is present at very low expansion velocities, merely Almost-Equal-To 1000 km s{sup -1} above the bulk of Si II. Based on spectral modeling, it is found that the detections are consistent with a mass of carbon of 10{sup -3} to 10{sup -2} M{sub Sun }. The presence of this material so deep in the ejecta would imply substantial mixing, which may be related to asymmetries of the flame propagation. Another possible explanation for the carbon absorptions may be the existence of clumps of unburned material along the line of sight. However, the uniformity of the relation between C II and Si II velocities is not consistent with such small-scale asymmetries. The spectroscopic and photometric properties of SNe Ia with and without carbon signatures are compared. A trend toward bluer color and lower luminosity at maximum light is found for objects which show carbon.

79 ASTRONOMY AND ASTROPHYSICS↗

Synthetic observations of the evolution of starless cores in a molecular cloud simulation: Comparisons with JCMT data and predictions for alma

Interpreting the nature of starless cores has been a prominent goal in star formation for many years. In order to characterize the evolutionary stages of these objects, we perform synthetic observations of a numerical simulation of a turbulent molecular cloud. We find that nearly all cores that we detect are associated with filaments and eventually form protostars. We conclude that observed starless cores that appear Jeans unstable are only marginally larger than their respective Jeans masses (within a factor of three). We note single dish observations such as those performed with the James Clerk Maxwell Telescope appear to miss significant core structure on small scales because of beam averaging. Finally, we predict that interferometric observations with Atacama Large Millimeter Array Cycle 1 will resolve the important small-scale structure, which has so far been missed by millimeter wavelength observations.

79 ASTRONOMY AND ASTROPHYSICS↗

SURVEY SIMULATIONS OF A NEW NEAR-EARTH ASTEROID DETECTION SYSTEM

We have carried out simulations to predict the performance of a new space-based telescopic survey operating at thermal infrared wavelengths that seeks to discover and characterize a large fraction of the potentially hazardous near-Earth asteroid (NEA) population. Two potential architectures for the survey were considered: one located at the Earth–Sun L1 Lagrange point, and one in a Venus-trailing orbit. A sample cadence was formulated and tested, allowing for the self-follow-up necessary for objects discovered in the daytime sky on Earth. Synthetic populations of NEAs with sizes as small as 140 m in effective spherical diameter were simulated using recent determinations of their physical and orbital properties. Estimates of the instrumental sensitivity, integration times, and slew speeds were included for both architectures assuming the properties of newly developed large-format 10 μm HgCdTe detector arrays capable of operating at ∼35 K. Our simulation included the creation of a preliminary version of a moving object processing pipeline suitable for operating on the trial cadence. We tested this pipeline on a simulated sky populated with astrophysical sources such as stars and galaxies extrapolated from Spitzer Space Telescope and Wide-field Infrared Explorer data, the catalog of known minor planets (including Main Belt asteroids, comets, Jovian Trojans, planets, etc.), and the synthetic NEA model. Trial orbits were computed for simulated position-time pairs extracted from the synthetic surveys to verify that the tested cadence would result in orbits suitable for recovering objects at a later time. Our results indicate that the Earth–Sun L1 and Venus-trailing surveys achieve similar levels of integral completeness for potentially hazardous asteroids larger than 140 m; placing the telescope in an interior orbit does not yield an improvement in discovery rates. This work serves as a necessary first step for the detailed planning of a next-generation NEA survey.

79 ASTRONOMY AND ASTROPHYSICS↗

sUAS Support for Mars 2020

The release of airborne radioactive material presents a health risk hazard to many individuals, including emergency responders and the public. Characterizing the unknown radioactive dangers produced during such incidents is essential. An advantage to utilizing unmanned aerial systems in this effort is the reduction of risk to personnel otherwise tasked with characterization, as well as more quickly obtaining data points during cloud immersion. By pairing a continuous air monitor (CAM) and detector with a drone, quantification of unknown material in the plume can be determined, and thus the extent of dose to people in the area can be estimated. A small, low-flow air sampler with a Geiger-Mueller counter may be characterized using experimental measurements of point sources representing a cloud of material and modelled using the Monte Carlo N-Particle Transport Code (MCNP), a software package for simulating nuclear processes, to find the usefulness and advantages of the system for detection of nuclides of concern in various nuclear plume scenarios. The flying time of small-unmanned aircraft systems (sUASs) is limited; thus, the minimum detectable activity and concentration rates possible must be determined over the system’s window of operation. While the activity concentrations corresponding to external and internal doses of concern can be detected with certainty for 90 Sr and 137 Cs in a plume, those corresponding to 238 Pu are more difficult to detect. The central principle of employing the sUAS is that the cockpit does not have an operator onboard the aircraft; therefore, control of the aircraft must take place by other means. With a sUAS, command and control can be separated into three distinct methods: (1) ground control or remote piloting, (2) semi-autonomous control, and (3) autonomous control. The isotope 238 Pu is used in the space industry, providing long-lived heat generation for fuel in outer space (NASA 2014). Due to the inherent risks with rocket launches to get objects into space, monitoring for release of these hazardous substances is a major undertaking. The current means is through employment of environmental CAMs. It is conceivable, however, that drone monitoring for release of 238 Pu in the event of a space launch mishap would give a greater chance of detection of plutonium particulate, because the particulate’s diffusion in air upon settling to the ground would make the probability of collecting a particle on a filter in a CAM very low.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Objective and Efficient Method for Assessing the Impact of Reduced-Precision Calculations On Solution Correctness

Recent studies have shown that reducing the precision of floating-point calculations in an atmospheric model can improve the models' computational performance without affecting model fidelity, but code changes are needed to accommodate lower precision, and a small number of calculations might need to retain higher precision to prevent undue round-off error. For complex and computationally expensive systems like the Energy Exascale Earth System Model (E3SM), a method is needed to objectively assess the quality of the lower-precision simulations and to quickly identify problematic code pieces This paper demonstrates that solution correctness can be evaluated through a simple and quantitative error metric based on time step convergence. The proposed test method can unambiguously detect the accumulation of precision error and objectively assess its impact on solution accuracy. Since fast physical processes are known to affect key features of the multi-year mean climate in an atmospheric model, we show that the convergence test applied to short simulations can provide useful information about the impact of reduced precision on a model’s long-term behavior. In contrast, the traditional way of climate model evaluation requires multi-year simulations and involves inspecting many physical quantities for statistical significance in the presence of natural variability. The simplicity, computational efficiency, and objectivity of the proposed method makes it very attractive for high-resolution model development. The method is also expected to be applicable to other models that numerically solve time evolution equations.

97 MATHEMATICS AND COMPUTING↗

DETECTION OF AN ULTRA-BRIGHT SUBMILLIMETER GALAXY BEHIND THE SMALL MAGELLANIC CLOUD

We report the discovery of a new ultra-bright submillimeter galaxy (SMG) behind the Small Magellanic Cloud (SMC). This SMG is detected as a 43.3 {+-} 8.4 mJy point source (MM J01071-7302, hereafter MMJ0107) in the 1.1 mm continuum survey of the SMC by AzTEC on the ASTE telescope. MMJ0107 is also detected in the radio (843 MHz), Herschel/SPIRE, Spitzer MIPS 24 {mu}m, all IRAC bands, Wide-field Infrared Survey Explorer, and near-infrared (J, H, K{sub S} ). We find an optical (U, B, V) source, which might be the lensing object, at a distance of 1.''4 from near-infrared and IRAC sources. Photometric redshift estimates for the SMG using representative spectral energy distribution templates show the redshifts of 1.4-3.9. We estimate total far-infrared luminosity of (0.3-2.2) Multiplication-Sign 10{sup 14} {mu}{sup -1} L{sub Sun} and a star formation rate of 5600-39, 000 {mu}{sup -1} M{sub Sun} yr{sup -1}, where {mu} is the gravitational magnification factor. This apparent extreme star formation activity is likely explained by a highly magnified gravitational lens system.

79 ASTRONOMY AND ASTROPHYSICS↗

DETECTABILITY OF GLYCINE IN SOLAR-TYPE SYSTEM PRECURSORS

Glycine (NH{sub 2}CH{sub 2}COOH) is the simplest amino acid relevant to life. Its detection in the interstellar medium is key to understanding the formation mechanisms of pre-biotic molecules and their subsequent delivery onto planetary systems. Glycine has been extensively searched for toward hot molecular cores, although these studies did not yield any firm detection. In contrast to hot cores, low-mass star forming regions, in particular their earliest stages represented by cold pre-stellar cores, may be better suited for the detection of glycine as well as more relevant to the study of pre-biotic chemistry in young solar system analogs. We present one-dimensional spherically symmetric radiative transfer calculations of the glycine emission expected to arise from the low-mass pre-stellar core L1544. Water vapor has recently been reported toward this core, indicating that a small fraction of the grain mantles in L1544 (∼0.5%) has been injected into the gas phase. Assuming that glycine is photo-desorbed together with water in L1544, and considering a solid abundance of glycine on ices of ∼10{sup –4} with respect to water, our calculations reveal that several glycine lines between 67 GHz and 80 GHz have peak intensities larger than 10 mK. These results show for the first time that glycine could reach detectable levels in cold objects such as L1544. This opens up the possibility of detecting glycine, and other pre-biotic species, at the coldest and earliest stages in the formation of solar-type systems with near-future instrumentation such as the Band 2 receivers of ALMA.

79 ASTRONOMY AND ASTROPHYSICS↗

INVISIBLE ACTIVE GALACTIC NUCLEI. II. RADIO MORPHOLOGIES AND FIVE NEW H i 21 cm ABSORPTION LINE DETECTORS

This is the second paper directed toward finding new highly redshifted atomic and molecular absorption lines at radio frequencies. To this end, we selected a sample of 80 candidates for obscured radio-loud active galactic nuclei (AGNs) and presented their basic optical/near-infrared (NIR) properties in Paper I. In this paper, we present both high-resolution radio continuum images for all of these sources and H i 21 cm absorption spectroscopy for a few selected sources in this sample. A-configuration 4.9 and 8.5 GHz Very Large Array continuum observations find that 52 sources are compact or have substantial compact components with size <0.″5 and flux densities >0.1 Jy at 4.9 GHz. The 36 most compact sources were then observed with the Very Long Baseline Array at 1.4 GHz. One definite and 10 candidate Compact Symmetric Objects (CSOs) are newly identified, which is a detection rate of CSOs ∼three times higher than the detection rate previously found in purely flux-limited samples. Based on possessing compact components with high flux densities, 60 of these sources are good candidates for absorption-line searches. Twenty-seven sources were observed for H i 21 cm absorption at their photometric or spectroscopic redshifts with only six detections (five definite and one tentative). However, five of these were from a small subset of six CSOs with pure galaxy optical/NIR spectra (i.e., any AGN emission is obscured) and for which accurate spectroscopic redshifts place the redshifted 21 cm line in a radio frequency intereference (RFI)-free spectral “window” (i.e., the percentage of H i 21 cm absorption-line detections could be as high as ∼90% in this sample). It is likely that the presence of ubiquitous RFI and the absence of accurate spectroscopic redshifts preclude H i detections in similar sources (only 1 detection out of the remaining 22 sources observed, 13 of which have only photometric redshifts); that is, H i absorption may well be present but is masked by the RFI. Future searches for highly redshifted H i and molecular absorption can easily find more distant CSOs among bright, “blank field” radio sources, but will be severely hampered by an inability to determine accurate spectroscopic redshifts due to their lack of rest-frame UV continuum.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-B-210-00: Carson/Zagzebski Distinguished Lectureship

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

WE-B-210-01: Introduction

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

WE-B-210-02: The Advent of Ultrafast Imaging in Biomedical Ultrasound

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

WE-B-210-03: Closing

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

Ultra-sensitive magnetic microscopy with an optically pumped magnetometer

Optically pumped magnetometers (OPMs) based on lasers and alkali-metal vapor cells are currently the most sensitive non-cryogenic magnetic field sensors. Many applications in neuroscience and other fields require high-resolution, high-sensitivity magnetic microscopic measurements. In order to meet this demand we combined a cm-size spin-exchange relaxation-free (SERF) OPM and flux guides (FGs) to realize an ultra-sensitive FG-OPM magnetic microscope. The FGs serve to transmit the target magnetic flux to the OPM thus improving both the resolution and sensitivity to small magnetic objects. We investigated the performance of the FG-OPM device using experimental and numerical methods, and demonstrated that an optimized device can achieve a unique combination of high resolution (80 μm) and high sensitivity (8.1 pT/). Additionally, we also performed numerical calculations of the magnetic field distribution in the FGs to estimate the magnetic noise originating from the domain fluctuations in the material of the FGs. We anticipate many applications of the FG-OPM device such as the detection of micro-biological magnetic fields; the detection of magnetic nano-particles; and non-destructive testing. From our theoretical estimate, an FG-OPM could detect the magnetic field of a single neuron, which would be an important milestone in neuroscience.

47 OTHER INSTRUMENTATION↗

RESOLUTION OF THE COMPACT RADIO CONTINUUM SOURCES IN Arp220

We present 2 cm and 3.6 cm wavelength very long baseline interferometry images of the compact radio continuum sources in the nearby ultra-luminous infrared galaxy Arp220. Based on their radio spectra and variability properties, we confirm these sources to be a mixture of supernovae (SNe) and supernova remnants (SNRs). Of the 17 detected sources we resolve 7 at both wavelengths. The SNe generally only have upper size limits. In contrast all the SNRs are resolved with diameters {>=}0.27 pc. This size limit is consistent with them having just entered their Sedov phase while embedded in an interstellar medium (ISM) of density 10{sup 4} cm{sup -3}. These objects lie on the diameter-luminosity correlation for SNRs (and so also on the diameter-surface brightness relation) and extend these correlations to very small sources. The data are consistent with the relation L{proportional_to}D{sup -9/4}. Revised equipartition arguments adjusted to a magnetic field to a relativistic particle energy density ratio of 1% combined with a reasonable synchrotron-emitting volume filling factor of 10% give estimated magnetic field strengths in the SNR shells of {approx}15-50 mG. The SNR shell magnetic fields are unlikely to come from compression of ambient ISM fields and must instead be internally generated. We set an upper limit of 7 mG for the ISM magnetic field. The estimated energy in relativistic particles, 2%-20% of the explosion kinetic energy, is consistent with estimates from models that fit the IR-radio correlation in compact starburst galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Island of misfit tortoises: waif gopher tortoise health assessment following translocation

Translocation, the intentional movement of animals from one location to another, is a common management practice for the gopher tortoise (Gopherus polyphemus). Although the inadvertent spread of pathogens is a concern with any translocation effort, waif tortoises—individuals that have been collected illegally, injured and rehabilitated or have unknown origins—are generally excluded from translocation efforts due to heightened concerns of introducing pathogens and subsequent disease to naïve populations. However, repurposing these long-lived animals for species recovery is desirable when feasible, and introducing waif tortoises may bolster small populations facing extirpation. The objective of this study was to assess the health of waif tortoises experimentally released at an isolated preserve in Aiken County, SC, USA. Our assessments included visual examination, screening for 14 pathogens using conventional or quantitative polymerase chain reaction (qPCR) and haematological evaluation. Of the 143 individuals assessed in 2017 and 2018, most individuals (76%; n = 109 of 143) had no overt clinical evidence of disease and, when observed, clinical findings were mild. In both years, we detected two known tortoise pathogens, Mycoplasma agassizii and Mycoplasma testudineum, at a prevalence of 10.2–13.9% and 0.0–0.8%, respectively. Additionally, we found emydid Mycoplasma, a bacterium commonly found in box turtles (Terrapene spp.), in a single tortoise that showed no clinical evidence of infection. The presence of nasal discharge was an important, but imperfect, predictor of Mycoplasma spp. infection in translocated tortoises. Hemogram data were comparable with wild populations. Our study is the first comprehensive effort to assess pathogen prevalence and hemogram data of waif gopher tortoises following translocation. Although caution is warranted and pathogen screening necessary, waif tortoises may be an important resource for establishing or augmenting isolated populations when potential health risks can be managed.

60 APPLIED LIFE SCIENCES↗

BLADE: An Automated Framework for Classifying Light Curves from the Center for Near-Earth Object Studies Fireball Database

Fireballs (bolides) are high-energy luminous phenomena produced when meteoroids and small asteroids enter Earth’s atmosphere at hypersonic speeds, often resulting in fragmentation or complete disintegration accompanied by significant energy release. The resulting bolide light curves capture temporal brightness variations as these objects traverse increasingly dense atmospheric layers, providing essential information on meteoroid entry dynamics, fragmentation behavior, and atmospheric energy deposition processes. The Center for Near-Earth Object Studies’ (CNEOS) continuously expanding fireball database offers a globally comprehensive archive of bolide events, including light curves and associated metadata. Events associated with infrasound detections allow direct correlations between acoustic signatures and light curve features, therefore enabling detailed analyses of fragmentation dynamics and energy deposition. Here, we introduce Bolide Light-curve Analysis and Discrimination Explorer (BLADE), a robust and high-fidelity framework specifically designed to analyze bolide light curves for objects detected from space. BLADE incorporates a processing pipeline integrating Savitzky–Golay filtering, prominence-based peak detection, and gradient analysis, enabling systematic identification and classification of fragmentation events and their associated energy release characteristics. Preliminary results demonstrate that BLADE reliably distinguishes distinct bolide behaviors, providing an objective, scalable methodology for characterization and analysis of large bolide light curve data sets. This foundational work establishes a novel pathway for advanced bolide research, with promising applications in planetary defense and global atmospheric monitoring. Future research should adopt an integrative approach combining CNEOS optical data with complementary infrasound measurements, further clarifying relationships between bolide energy deposition and acoustic signatures, thus refining our understanding of meteoroid and asteroid atmospheric entry processes.

Asteroids↗

SPITZER 24 {mu}m SURVEY FOR DUST DISKS AROUND HOT WHITE DWARFS

Two types of dust disks around white dwarfs (WDs) have been reported: small dust disks around cool metal-rich WDs consisting of tidally disrupted asteroids and a large dust disk around the hot central WD of the Helix planetary nebula (PN) possibly produced by collisions among Kuiper-Belt-like objects. To search for more dust disks of the latter type, we have conducted a Spitzer MIPS 24 {mu}m survey of 71 hot WDs or pre-WDs, among which 35 are central stars of PNe (CSPNs). Nine of these evolved stars are detected and their 24 {mu}m flux densities are at least two orders of magnitude higher than their expected photospheric emission. Considering the bias against the detection of distant objects, the 24 {mu}m detection rate for the sample is {approx}>15%. It is striking that seven, or {approx}20%, of the WD and pre-WDs in known PNe exhibit 24 {mu}m excesses, while two, or 5%-6%, of the WDs not in PNe show 24 {mu}m excesses and they have the lowest 24 {mu}m flux densities. We have obtained follow-up Spitzer Infrared Spectrograph spectra for five objects. Four show clear continuum emission at 24 {mu}m, and one is overwhelmed by a bright neighboring star but still shows a hint of continuum emission. In the cases of WD 0950+139 and CSPN K 1-22, a late-type companion is present, making it difficult to determine whether the excess 24 {mu}m emission is associated with the WD or its red companion. High-resolution images in the mid-infrared are needed to establish unambiguously the stars responsible for the 24 {mu}m excesses.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid Response Radiation Sensors for Homeland Security Applications

The National Security Technologies, LLC, Remote Sensing Laboratory is developing a rapid response radiation detection system for homeland security field applications. The intelligence-driven system is deployed only when non-radiological information about the target is verifiable. The survey area is often limited, so the detection range is small; in most cases covering a distance of 10 meters or less suffices. Definitive response is required in no more than 3 seconds and should minimize false negative alarms, but can err on the side of positive false alarms. The detection system is rapidly reconfigurable in terms of size, shape, and outer appearance; it is a plug-and-play system. Multiple radiation detection components (viz., two or more sodium iodide scintillators) are used to independently “over-determine” the existence of the threat object. Rapid response electronic dose rate meters are also included in the equipment suite. Carefully studied threat signatures are the basis of the decision making. The use of Rad-Detect predictive modeling provides information on the nature of the threat object. Rad-Detect provides accurate dose rate from heavily shielded large sources; for example those lost in Mexico were Category 1 radiation sources (~3,000 Ci of 60Co), the most dangerous of five categories defined by the International Atomic Energy Agency. Taken out of their shielding containers, Category 1 sources can kill anyone who is exposed to them at close range for a few minutes to an hour. Whenever possible sub-second data acquisition will be attempted, and, when deployed, the system will be characterized for false alarm rates. Although the radiation detection materials selected are fast (viz., faster scintillators), their speed is secondary to sensitivity, which is of primary importance. Results from these efforts will be discussed and demonstrated.

gamma detector, false alarm rate, sub-second data ↗