Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Single Photon Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Development of a Sodium LIDAR for Spaceborne Missions

We are currently developing laser and electro-optic technologies to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of a Heliophysics mission targeted to study the composition and dynamics of Earths mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. There is a pressing need in the Ionosphere Thermosphere - Mesosphere (ITM) community for high-resolution measurements that can characterize small-scale dynamics (i.e. Gravity Waves with wavelengths smaller than a few hundred km) and their effects in the Mesosphere-Lower-Termosphere (MLT) on a global basis. This is compelling because they are believed to be the dominant contributors to momentum transport and deposition in the MLT, which largely drive the global circulation and thermal structure and interactions with the tides and planetary waves in this region. We are developing a spaceborne remote sensing technique that will enable acquisition of global Na density, temperature and wind measurements in the MLT with the spatial and temporal resolution required to resolve issues associated with the structure, chemistry, dynamics, and energetics of this regionA nadir-pointing spaceborne Na Doppler resonance fluorescence LIDAR on board of the ISS will essentially make high-resolution, in time and space, Na density, temperature and vertical wind measurements, from 75-115 km (MLT region). Our instrument concept consisted of a high-energy laser transmitter at 589 nm and highly sensitive photon counting detector that allows for range-resolved atmospheric-sodium-temperature profiles. The atmospheric temperature is deduced from the linewidth of the resonant fluorescence from the atomic sodium vapor D2 line as measured by our tunable laser. We are currently developing a high power energy laser that allows for some day time sodium lidar observations with the help of a narrow bandpass filter based on etalon or atomic sodium Faraday filter with 5 to 10 pm optical bandwidth. The current baseline detector for the lidar instrument is a 16-channel Photomultiplier Tube with receiver electronics that has been space-qualified for the ICESat-2ATLAS mission. Our technique uses the 16-channels as a photon-number-resolving single detector to provide the required full-spectroscopic sodium lineshape waveform for recovering Mesospheric temperature profiles. In this paper, we will describe our instrument concept for a future Heliophysics space mission based on board of the International Space Station (ISS).

lidar↗

Cloud Thickness from Diffusion of Lidar Pulses in Clouds

Measurements of the distribution of reflected light from a laser beam incident on an aqueous suspension of particles or "cloud" with known thickness and particle size distribution are reported. The distribution is referred to as the "cloud radiative Green's function", G. In the diffusion domain, G is sensitive to cloud thickness, allowing that important quantity to be retrieved. The goal of the laboratory simulation is to provide preliminary estimates of sensitivity of G to cloud thickness,for use in the optimal design of an offbeam Lidar instrument for remote sensing of cloud thickness (THOR, Thickness from Offbeam Returns). These clouds of polystyrene microspheres suspended in water are analogous to real clouds of water droplets suspended in air. The microsphere size distribution is roughly lognormal, from 0.5 microns to 25 microns, similar to real clouds. Density of suspended spheres is adjusted so mean-free-path of visible photons is about 10 cm, approximately 1000 times smaller than in real clouds. The light source is a ND:YAG laser at 530 nm. Detectors are flux and photon-counting Photomultiplier Tube (PMTS), with a glass probe for precise positioning. A Labview 5 VI controls positioning, and data acquisition, via an NI Motion Control board connected to a stepper motor driving an Edmund linear slider, and a 16-channel 16-bit NI-DAQ board. The stepper motor is accurate to 10 microns, and step size is selectable from the VI software. Far from the incident beam, the rate of exponential increase as the direction of the incident beam is approached scales as expected from diffusion theory, linearly with the cloud thickness, and inversely as the square root of the reduced optical thickness, and is independent of particle size. Near the beam the signal begins to increase faster than exponential, due to single and low-order scattering near the backward direction, and here the distribution depends on particle size. Results are being used to verify 3D Monte Carlo radiative transfer simulations, used to estimate signal-to-noise ratios for remotely sensed off beam returns, for both homogeneous and inhomogeneous clouds. Signal-to-noise estimates show that unfiltered observations are straight forward at night, while narrow band pass filters are being studied for day.

Cahalan, Robert F.↗

Photon-Counting Multikilohertz Microlaser Altimeters

Spaceborne laser altimeters in planetary orbit typically use high energy (approximately 100 mJ) solid state lasers, large telescopes (50 to 100 cm), and high detection thresholds to achieve unambiguous surface returns with few or no ifalse alarmsi resulting from solar background noise. As a result of this conservative design philosophy, spacecraft prime power weight, or size constraints typically restrict operations to modest repetition rates on the order of a few tens of Hz which, at a typical ground velocity of 7 Km/sec, limits along-track spatial sampling to one sample every few hundred meters. The surface return rate of an Earth-orbiting altimeter can be increased by up to two orders of magnitude for a given laser output power by emitting the available photons in a high frequency (few KHz) train of low energy (< 1 mJ) pulses, as produced by passively Q-switched solid state "microlasers", and using single photon detection. while simultaneously using much smaller telescope diameters on the order of 10 cm. Simple onboard software algorithms, based on post-detection Poisson filtering techniques, can be employed to identify and extract the surface data from solar background noise prior to onboard data storage or transmission to a ground station. Under NASAis Instrument Incubator Program, we have begun the design and construction of a scanning airborne instrument to demonstrate the potential advantages of the technique for future space missions.

Degnan, John J.↗

High-dynamic-range MCP structures

We report on the development of a new high-dynamic-range two-stage Multi-Anode Microchannel Array (MAMA) imaging tube designed for improved high count rate performance at FUV and EUV wavelengths. The new two-stage MAMA tube employs two 25-mm-diameter format MCPs placed in tandem with a small gap between the plates. The front (input) MCP is designed to be a low-gain converter plate that supports an opaque photocathode and converts the detected photons to electrons, while the second (output) MCP is of higher conductivity and thus maintains the overall gain of the multiplier at high count rates. The second MCP is mounted in proximity focus with a (224 x 960)-pixel fine-fine coincidence MAMA array for high-spatial-resolution imaging studies. The applied voltage across each MCP can be controlled independently. We report on the gain and dynamic range performance characteristics of the two-stage MAMA tube in two different configurations: first, with the output MCP having moderate conductivity (about 100 MOhm); and second, with the output MCP having very high conductivity (about 2 MOhm). These results are compared and contrasted with those of the more conventional MAMA tube configuration which employs a single high-gain curved-channel MCP.

Slater, David C.↗

Few-Mode Fiber Coupled Superconducting Nanowire Single-Photon Detectors for Photon Efficient Optical Communications

The NASA Glenn Research Center's development of a high-photon efficiency real-time optical communications ground receiver has added superconducting nanowire single-photon detectors (SNSPDs) coupled with few-mode fibers (FMF). High data rate space-to-ground optical communication links require enhanced ground receiver sensitivity to reduce spacecraft transmitter constraints, and therefore require highly efficient coupling from fiber to detector. In the presence of atmospheric turbulence the received optical wave front can be severely distorted introducing higher-order spatial mode components to the received signal. To reduce mode filtering and mismatch loss and the resulting degradations to detector coupling efficiency, we explore the use of few-mode fiber coupling to commercial single-pixel SNSPDs. Graded index 20-µm few-mode fibers allow the commercial single pixel SNSPD's active area to couple with equal efficiency as single mode fibers. Here we determine detector characteristics such as count rate, detection efficiency, dark counts, and jitter, as well as detection efficiencies for higher-order fiber spatial modes. Additionally, we assess the laboratory performance of the detectors in an optical system which emulates future deep space optical communications links.

Vyhnalek, Brian E.↗

A gain series method for accurate EMCCD calibration

Abstract Calibration of the gain and digital conversion factor of an EMCCD is necessary for accurate photon counting. We present a new method to quickly calibrate multiple gain settings of an EMCCD camera. Acquiring gain-series calibration data and analyzing the resulting images with the EMCCD noise model more accurately estimates the gain response of the camera. Furthermore, we develop a method to compare the results from different calibration approaches. Gain-series calibration outperforms all other methods in this self-consistency test.

36 MATERIALS SCIENCE↗

Approaching the Ultimate Limits of Communication Efficiency with a Photon-Counting Detector

Coherent states achieve the Holevo capacity of a pure-loss channel when paired with an optimal measurement, but a physical realization of this measurement is as of yet unknown, and it is also likely to be of high complexity. In this paper, we focus on the photon-counting measurement and study the photon and dimensional efficiencies attainable with modulations over classical- and nonclassical-state alphabets. We first review the state-of-the-art coherent on-off-keying (OOK) with a photoncounting measurement, illustrating its asymptotic inefficiency relative to the Holevo limit. We show that a commonly made Poisson approximation in thermal noise leads to unbounded photon information efficiencies, violating the conjectured Holevo limit. We analyze two binary-modulation architectures that improve upon the dimensional versus photon efficiency tradeoff achievable with conventional OOK. We show that at high photon efficiency these architectures achieve an efficiency tradeoff that differs from the best possible tradeoff--determined by the Holevo capacity--by only a constant factor. The first architecture we analyze is a coherent-state transmitter that relies on feedback from the receiver to control the transmitted energy. The second architecture uses a single-photon number-state source.

thermal noises↗

Observation of biexciton emission from single semiconductor nanoplatelets

Quasi-two-dimensional semiconductor nanoplatelets (NPLs) are intriguing systems for studying the influence of Auger recombination processes on the multiexciton emission efficiencies in the weak in-plane confinement regime. We investigate CdSe/CdS core/shell NPLs using cryogenic temperature single particle spectroscopy and observe bright biexciton emission at high excitation powers. The average binding energy of the biexcitons is determined to be 16.5 meV. The observed switching between the biexciton and trion states indicates charging-decharging dynamics of the NPLs mediated by the Auger ionization process. These findings are highly relevant for harvesting efficient biexciton emission for energy, lighting, and quantum applications.

36 MATERIALS SCIENCE↗

The Single Aperture Far-Infrared (SAFIR) Observatory and its Cryogenic Detector Needs

The development of a large, far-infrared telescope in space has taken on a new urgency with breakthroughs in detector technology and recognition of the fundamental importance of the far-infrared spectral region to questions ranging from cosmology to our own Solar System. The Single Aperture Far-InfraRed (SAFIR) Observatory is l0m-class far-infrared observatory that would begin development later in this decade to meet these needs. SAFIR's science goals are driven by the fact that youngest stages of almost all phenomena in the universe are shrouded in absorption by and emission from cool dust that emits strongly in the far-infrared, 20 microns - 1mm. Its operating temperature (4 K) and instrument complement would be optimized to reach the natural sky confusion limit in the far-infrared with diffraction-limited performance down to at least the atmospheric cutoff at 40 microns. This would provide a point source sensitivity improvement of several orders of magnitude over that of SIRTF. In order to achieve this, large arrays of detectors with NEPs ranging from a few to a hundred zeptowatts/sqrt(Hz) are needed. Very low temperature superconducting transition edge sensors and far-infrared "photon counting" detectors are critical technologies requiring development for the SAFIR mission.

Benford, Dominic J.↗

Estimating Random Errors Due to Shot Noise in Backscatter Lidar Observations

In this paper, we discuss the estimation of random errors due to shot noise in backscatter lidar observations that use either photomultiplier tube (PMT) or avalanche photodiode (APD) detectors. The statistical characteristics of photodetection are reviewed, and photon count distributions of solar background signals and laser backscatter signals are examined using airborne lidar observations at 532 nm using a photon-counting mode APD. Both distributions appear to be Poisson, indicating that the arrival at the photodetector of photons for these signals is a Poisson stochastic process. For Poisson-distributed signals, a proportional, one-to-one relationship is known to exist between the mean of a distribution and its variance. Although the multiplied photocurrent no longer follows a strict Poisson distribution in analog-mode APD and PMT detectors, the proportionality still exists between the mean and the variance of the multiplied photocurrent. We make use of this relationship by introducing the noise scale factor (NSF), which quantifies the constant of proportionality that exists between the root-mean-square of the random noise in a measurement and the square root of the mean signal. Using the NSF to estimate random errors in lidar measurements due to shot noise provides a significant advantage over the conventional error estimation techniques, in that with the NSF uncertainties can be reliably calculated from/for a single data sample. Methods for evaluating the NSF are presented. Algorithms to compute the NSF are developed for the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) lidar and tested using data from the Lidar In-space Technology Experiment (LITE). OCIS Codes:

Liu, Zhaoyan↗

Solid state photomultiplier for astronomy, phase 2

Epitaxial layers with varying donor concentration profiles were grown on silicon substrate wafers using chemical vapor deposition (CVD) techniques, and solid state photomultiplier (SSPM) devices were fabricated from the wafers. Representative detectors were tested in a low background photon flux, low temperature environment to determine the device characteristics for comparison to NASA goals for astronomical applications. The SSPM temperatures varied between 6 and 11 K with background fluxes in the range from less than 5 x 10 to the 6th power to 10 to the 13th power photons/square cm per second at wavelengths of 3.2 and 20 cm. Measured parameters included quantum efficiency, dark count rate and bias current. Temperature for optimal performance is 10 K, the highest ever obtained for SSPMs. The devices exhibit a combination of the lowest dark current and highest quantum efficiency yet achieved. Experimental data were reduced, analyzed and used to generate recommendations for future studies. The background and present status of the microscopic theory of SSPM operation were reviewed and summarized. Present emphasis is on modeling of the avalanche process which is the basis for SSPM operation. Approaches to the solution of the Boltzmann transport equation are described and the treatment of electron scattering mechanisms is presented. The microscopic single-electron transport theory is ready to be implemented for large-scale computations.

Besser, P. J.↗

Injector Mixing Efficiency Experiments

Various optical diagnostic techniques such as laser induce fluorescence, Raman spectroscopy, laser Doppler velocimetry, and laser light scattering have been employed to study the flowfield downstream of a single injector element in a optically accessible rocket chamber at Penn State for a number o years. These techniques have been used with both liquid and gaseous oxygen at pressures up to 1000 psia which is the limit of the facility. The purpose of the test programs at Penn State were to develop the techniques and to study the flow field from various injector designs. To extend these studies to higher pressure and ultimately to multiple injectors require the capabilities of the Marshall Space Flight Center. These studies will extend the data base available for the various injector designs to higher pressure as well as to determine the interaction between multiple injectors. During this effort the Princeton Instruments ICCD camera was set up and checked out. The functionality of the system has been thoroughly checked and the shutter compensation time was found to be not working. The controller was returned to the manufacturer for warranty repair. The sensitivity has been measured and found to be approximately 60 counts per photon at maximum gain which agrees with the test data supplied by the manufacturer. The actual value depends on wavelength. The Princeton Instruments camera was been installed in a explosion proof tube for use with the rocket combustor. A 35 mm camera was also made ready for taking still photos inside the combustor. A fiber optic was used to transmit the laser light from an argon-ion laser to the rocket combustor for the light scattering images. This images were obtained for a LOX-hydrogen swirl coax injector. Several still photos were also obtained with the 35 mm camera for these firings.

Moser, Marlow D.↗

ICESat-2 Atmospheric Channel Description, Data Processing and First Results

The Advanced Topographic Laser Altimeter System (ATLAS) was launched aboard the Ice Cloud and land-Elevation Satellite-2 (ICESat-2) satellite in September 2018. ATLAS is a single wavelength (532 nm) lidar system designed to acquire high resolution measurements of the earth's surface while also obtaining atmospheric backscatter from molecules, clouds, and aerosols. Because ATLAS is optimized for altimetry, the atmospheric data acquired is unique in many respects and requires non-standard analysis techniques. For example, the high repetition rate laser limits the vertical extent of the profiles to just 14 km and causes atmospheric scattering from above 15 km to be added to the scattering in the lower 0–14 km profile. In addition, the limited vertical range of the acquired profiles renders it difficult to compute the magnitude of the solar background and hinders the application of standard calibration techniques. Despite these limitations, methods have been developed to successfully produce data products that have value to the atmospheric community for cloud and aerosol research and are currently available at the National Snow and Ice Data Center (NSIDC). In this paper we describe the ICESat-2 atmospheric channel and the methods used to process the ATLAS raw photon count data to obtain calibrated backscatter and higher level products such as layer heights and type, blowing snow, column optical depth and apparent surface reflectance.

Stephen P Palm↗

Graviton detection and the quantization of gravity

We revisit a question asked by Dyson: “Is a graviton detectable?” We demonstrate that in both Dyson’s original sense and in a more modern measurement-theoretic sense, it is possible to construct a detector sensitive to single gravitons, and in fact a variety of existing and near-term gravitational wave detectors can achieve this. However, while such a signal would be consistent with the quantization of the gravitational field, we draw on results from quantum optics to show how the same signal could just as well be explained via classical gravitational waves. We outline the kind of measurements that would be needed to demonstrate quantization of gravitational radiation and explain why these are substantially more difficult than simply counting graviton clicks or observing gravitational noise in an interferometer, and likely impossible to perform in practice. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

NASA Tech Briefs, October 2007

Topics covered include; Wirelessly Interrogated Position or Displacement Sensors; Ka-Band Radar Terminal Descent Sensor; Metal/Metal Oxide Differential Electrode pH Sensors; Improved Sensing Coils for SQUIDs; Inductive Linear-Position Sensor/Limit-Sensor Units; Hilbert-Curve Fractal Antenna With Radiation- Pattern Diversity; Single-Camera Panoramic-Imaging Systems; Interface Electronic Circuitry for an Electronic Tongue; Inexpensive Clock for Displaying Planetary or Sidereal Time; Efficient Switching Arrangement for (N + 1)/N Redundancy; Lightweight Reflectarray Antenna for 7.115 and 32 GHz; Opto-Electronic Oscillator Using Suppressed Phase Modulation; Alternative Controller for a Fiber-Optic Switch; Strong, Lightweight, Porous Materials; Nanowicks; Lightweight Thermal Protection System for Atmospheric Entry; Rapid and Quiet Drill; Hydrogen Peroxide Concentrator; MMIC Amplifiers for 90 to 130 GHz; Robot Would Climb Steep Terrain; Measuring Dynamic Transfer Functions of Cavitating Pumps; Advanced Resistive Exercise Device; Rapid Engineering of Three-Dimensional, Multicellular Tissues With Polymeric Scaffolds; Resonant Tunneling Spin Pump; Enhancing Spin Filters by Use of Bulk Inversion Asymmetry; Optical Magnetometer Incorporating Photonic Crystals; WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics; Raman-Suppressing Coupling for Optical Parametric Oscillator; CO2-Reduction Primary Cell for Use on Venus; Cold Atom Source Containing Multiple Magneto- Optical Traps; POD Model Reconstruction for Gray-Box Fault Detection; System for Estimating Horizontal Velocity During Descent; Software Framework for Peer Data-Management Services; Autogen Version 2.0; Tracking-Data-Conversion Tool; NASA Enterprise Visual Analysis; Advanced Reference Counting Pointers for Better Performance; C Namelist Facility; and Efficient Mosaicking of Spitzer Space Telescope Images.

Source record↗

Bennett-Brassard 1984 quantum key distribution using conjugate homodyne detection

Optical homodyne detection has been widely used in continuous-variable (CV) quantum information processing for measuring field quadrature. In this paper we explore the possibility of operating a conjugate homodyne detection system in “photon counting” mode to implement discrete-variable (DV) quantum key distribution (QKD). A conjugate homodyne detection system, which consists of a beam splitter followed by two optical homodyne detectors, can simultaneously measure a pair of conjugate quadratures X and P of the incoming quantum state. In classical electrodynamics, X 2 + P 2 is proportional to the energy (the photon number) of the input light. In quantum optics, X and P do not commute and thus the above photon-number measurement is intrinsically noisy. This implies that a blind application of standard security proofs of QKD could result in pessimistic performance. We overcome this obstacle by taking advantage of two special features of the proposed detection scheme. First, the fundamental detection noise associated with vacuum fluctuations cannot be manipulated by an external adversary. Second, the ability to reconstruct the photon number distribution at the receiver's end can place additional constraints on possible attacks from the adversary. As an example, we study the security of the BB84 QKD using conjugate homodyne detection and evaluate its performance through numerical simulations. This study may open the door to a family of QKD protocols, complementary to the well-established DV-QKD based on single-photon detection and CV-QKD based on coherent detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗