Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A sensitivity analysis of the columnar-to-equiaxed transition for Ni-based superalloys in electron beam additive manufacturing

Solidification conditions experienced during Selective-Electron Beam Melting (S-EBM) of Nickel-Base superalloys generally lead to epitaxial grain growth from previous layers, resulting in highly textured columnar grain structures, and consequently, highly anisotropic mechanical properties. However, in recent work, researchers have been able to produce equiaxed grain structures by changing the scan strategy to influence the solidification conditions, thereby obtaining isotropic properties. The competition between columnar and equiaxed grain formation is governed by both the local thermal conditions and alloy thermodynamics. The above examples demonstrate successful manipulation of the thermal conditions through changes in process parameters. However, there is no guarantee that process conditions that encourage the formation of equiaxed grains for a given alloy will coincide with the production of defect free material. The goal of this work is therefore to understand the influence of alloy composition on the columnar-to-equiaxed transition (CET) so that alloys may be designed such that grain structure control is accessible to a wider range of S-EBM process conditions. A CET model originally developed by Hunt and extended by Gäumann was used to relate processing conditions to resulting microstructure. A sensitivity analysis of the CET model was performed using the Element Effects Methods. Furthermore, the results lead to a comparison of the relative effects of various alloying additions on the CET, as well as an assessment of other model parameters, including, most significantly, the nucleation density of equiaxed grains.

36 MATERIALS SCIENCE↗

Thermo-mechanical assessment of full SiC/SiC composite cladding for LWR applications with sensitivity analysis

SiC/SiC composites are considered among leading candidates for accident tolerant fuel cladding in light water reactors. However, when SiC-based materials are exposed to neutron irradiation, they experience significant changes in dimensions and physical properties. Under a large heat flux application (i.e. fuel cladding), the non-uniform changes in the dimensions and physical properties will lead to build-up of stresses in the structure over the course of time. To ensure reliable and safe operation of such a structure it is important to assess its thermo-mechanical performance under in-reactor conditions of irradiation and elevated temperature. In this work, the foundation for 3D thermo-mechanical analysis of SiC/SiC cladding is put in place and a set of analyses with simplified boundary conditions has been performed. The analyses were carried out with two different codes that were benchmarked against one another and prior results in the literature. A constitutive model is constructed and solved numerically to predict the stress distribution and variation in the cladding under normal operating conditions. The dependence of dimensions and physical properties variation with irradiation and temperature has been incorporated. These robust models may now be modified to take into account the axial and circumferential variation in neutron and heat flux to fully account for 3D effects. Here, the results from the simple analyses show the development of high tensile stresses especially in the circumferential and axial directions at the inner region of the cladding. Based on the results obtained, design guidelines are recommended. For lack of certainty in or tailor-ability for the physical and mechanical properties of SiC/SiC composite material a sensitivity analysis is conducted. The analysis results establish a precedence order of the properties based on the extent to which these properties influence the temperature and the stresses.

Accident tolerant fuel↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Exponential Decay in the Sensitivity Analysis of Nonlinear Dynamic Programming

In this report, we study the sensitivity of discrete-time dynamic programs with nonlinear dynamics and objective to perturbations in the initial conditions and reference parameters. Under uniform controllability and boundedness assumptions for the problem data, we prove that the directional derivative of the optimal state and control at time $k$, $x^*_k$, and $u^*_k$, with respect to the reference signal at time $i$, $d_i$, will have exponential decay in terms of $|k-i|$ with a decay rate $\rho$ independent of the temporal horizon length. The key technical step is to prove that a version of the convexification approach proposed by Verschueren et al. can be applied to the KKT conditions and results in a convex quadratic program with uniformly bounded data. In turn, Riccati techniques can be further employed to obtain the sensitivity result, borne from the observation that the directional derivatives are solutions of quadratic programs with structure similar to the KKT conditions themselves. We validate our findings with numerical experiments on a small nonlinear, nonconvex, dynamic program.

97 MATHEMATICS AND COMPUTING↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled Calculations of the NuScale FIV Tests – Pre-test Simulations and Sensitivity Analysis

The NEAMS program aims to develop an integrated multi-physics simulation capability “pellet-to-plant” for the design and analysis of future generations of nuclear power plants. In particular, the Reactor Product Line code suite's multi-resolution hierarchy is being designed to ultimately span the full range of length and time scales present in relevant reactor design and safety analyses, as well as scale from desktop to petaflop computing platforms. Flow-induced vibration (FIV) is widespread problem in energy systems because they rely on fluid movement for energy conversion. Vibrating structures may be damaged as fatigue or wear occurs. Given the importance of reliable components in the nuclear industry, flow-induced vibration has long been a major concern in safety and operation of nuclear reactors. In particular, nuclear fuel rods and steam generators have been known to suffer from flow-induced vibration and related failures. Advanced reactors, such as integral Pressurized Water Reactors (PWRs) considered for Small Modular Reactors (SMR), often rely on innovative component designs to meet cost and safety targets. One component that is the subject of advanced designs is the steam generator, some designs of which forego the usual shell-and-tube architecture in order to fit within the primary vessel. A significant amount of data exists on flow-induced vibration in shell-and-tube heat exchangers, and heuristic methods are available to predict FIV based on a set of given assumptions. In contrast, advanced designs have far less data available. Advanced modeling and simulation based on coupled structural and fluid simulations have the potential to predict flow-induced vibration in a variety of designs, reducing the need for expensive experimental programs, especially at the conceptual design stage. Over the past several years, the Reactor Product Line has developed a FIV capability in SHARP. SHARP contains high-fidelity single-physics codes Diablo for structural mechanics and Nek5000 for fluid mechanics calculations. Both codes are state-of-the-art, highly scalable tools that have been extensively validated. In previous reports we have discussed the implementation and validation of an FIV capability for helical steam generators and fuel assemblies. In this report we discuss one-way coupled calculations performed with Nek5000 and Diablo for the NuScale FIV tests. In the turbulent fretting regime one-way coupling is judged to be sufficient because the pressure loads do not cause substantial displacements. It is also the most common source of vibration in helical steam generators per the low flows expected in integral PWRs. The simulations precede the tests, as experimental data was not available at the delivery of this report. Several assumptions had to be made on the support-tube interaction and multiple tests and sensitivity analysis have been performed. Additional work remains to be done and it is discussed in the future work section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data Assimilation using Non-invasive Monte Carlo Sensitivity Analysis of Reactor Kinetics Parameters [Slides]

Sensitivity coefficients of prompt neutron decay constant (α) and effective delayed neutron fraction (β eff ) to Pu-239 nuclear data were calculated using a newly available tool (ACEtk). Uncertainty calculations showed the following trends: (1) The prompt neutron decay constant can be used to reduce nuclear data-induced uncertainty in Pu-239(n,f) and (2) the effective delayed neutron fraction can be used to effectively reduce nuclear data-induced uncertainty in Pu-239 total fission $\tilde{v}$. Sensitivity/uncertainty analysis can be used to determine optimal experiment/detector setup to identify compensating errors in nuclear data. Upcoming work includes investigating other nuclide-reaction pairs and response sensitivities, such as Δ$\rho$, neutron leakage spectra, and reaction rate measurements to constrain nuclear data of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Helium Refrigerator Liquid Nitrogen Pre-Cooler Component Parameter Sensitivity Analysis

For helium refrigerators using liquid nitrogen (LN) pre-cooling it is not uncommon for the ambient helium refrigeration return stream(s) exiting the cold box to be significantly colder and for the cycle to use more nitrogen than estimated by the process studies. Often there is an emphasis on the length of 300 to 80-K helium-nitrogen heat exchangers to ensure the exiting nitrogen is as close to ambient as possible. However, it is really the size and flow distribution of the 300 to 80-K helium-helium heat exchangers which are the dominate influence of the nitrogen consumption. As such, an analysis was done to identify and quantify the sensitivity the key parameters in the refrigerator LN pre-cooler section affecting the LN consumption.

42 ENGINEERING↗

PEBBED Uncertainty and Sensitivity Analysis of the CRP-5 PBMR DLOFC Transient Benchmark with the SUSA Code

The need for a defendable and systematic uncertainty and sensitivity approach that conforms to the Code Scaling, Applicability, and Uncertainty (CSAU) process, and that could be used for a wide variety of software codes, was defined in 2008. The GRS (Gesellschaft für Anlagen und Reaktorsicherheit) company of Germany has developed one type of CSAU approach that is particularly well suited for legacy coupled core analysis codes, and a trial version of their commercial software product SUSA (Software for Uncertainty and Sensitivity Analyses) was acquired on May 12, 2010. This report summarized the results of the initial investigations performed with SUSA, utilizing a typical High Temperature Reactor benchmark (the IAEA CRP-5 PBMR 400MW Exercise 2) and the PEBBED-THERMIX suite of codes. The following steps were performed as part of the uncertainty and sensitivity analysis: 1. Eight PEBBED-THERMIX model input parameters were selected for inclusion in the uncertainty study: the total reactor power, inlet gas temperature, decay heat, and the specific heat capability and thermal conductivity of the fuel, pebble bed and reflector graphite. 2. The input parameters variations and probability density functions were specified, and a total of 800 PEBBED-THERMIX model calculations were performed, divided into 4 sets of 100 and 2 sets of 200 Steady State and Depressurized Loss of Forced Cooling (DLOFC) transient calculations each. 3. The steady state and DLOFC maximum fuel temperature, as well as the daily pebble fuel load rate data, were supplied to SUSA as model output parameters of interest. The 6 data sets were statistically analyzed to determine the 5% and 95% percentile values for each of the 3 output parameters with a 95% confidence level, and typical statistical indictors were also generated (e.g. Kendall, Pearson and Spearman coefficients). 4. A SUSA sensitivity study was performed to obtain correlation data between the input and output parameters, and to identify the primary contributors to the output data uncertainties. It was found that the uncertainties in the decay heat, pebble bed and reflector thermal conductivities were responsible for the bulk of the propagated uncertainty in the DLOFC maximum fuel temperature. It was also determined that the two standard deviation (2s) uncertainty on the maximum fuel temperature was between ±58oC (3.6%) and ±76oC (4.7%) on a mean value of 1604 oC. These values mostly depended on the selection of the distributions types, and not on the number of model calculations above the required Wilks criteria (a (95%,95%) statement would usually require 93 model runs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Semi-analytical sensitivity analysis for nonlinear transient problems

Efficient analytical sensitivity computations are essential elements of gradient-based optimization schemes; however, they can be difficult to implement. This implementation issue is often resolved by adopting the semi-analytical method which exhibits the efficiency of the analytical methods and the ease of implementation of the finite difference method. However, care must be taken as semi-analytical sensitivities may exhibit errors due to truncation and round-off. Additional errors are introduced if the convergence tolerance of the primal analysis is not sufficiently small. This paper gives a general overview and some new developments of the analytical and semi-analytical sensitivity analyses for nonlinear steady-state, transient, and dynamic problems. We discuss the restrictive assumptions, accuracy, and consistency of these methods. Both adjoint and direct differentiation methods are studied. Numerical examples are provided.

42 ENGINEERING↗

Simulations of carbon dioxide push-pull into a conjugate fault system modeled after Dixie Valley—Sensitivity analysis of significant parameters and uncertainty prediction by data-worth analysis

Characterizing the faults and fractures that provide flow pathways for efficient geothermal energy production is critical for design of sustainable geothermal energy production. Both natural faults and stimulated fractures in enhanced geothermal systems (EGS) are difficult to image and map by seismic methods because hot brine filling the fractures and faults does not create a strong seismic property contrast relative to surrounding rock. We investigate here the technical feasibility of using supercritical CO 2 (scCO 2 ) injection into faults in a single-well push-pull scenario to characterize the hydraulic properties of the fault zone by emplacing scCO 2 that can serve as a contrast fluid for seismic monitoring. We develop a conceptual and numerical reservoir model of two intersecting faults based on the Dixie Valley geothermal system in Nevada, USA.

15 GEOTHERMAL ENERGY↗

Sensitivity analysis of static resistance of slender beam under bending

The paper deals with statical and sensitivity analyses of resistance of simply supported I-beams under bending. The resistance was solved by geometrically nonlinear finite element method in the programme Ansys. The beams are modelled with initial geometrical imperfections following the first eigenmode of buckling. Imperfections were, together with geometrical characteristics of cross section, and material characteristics of steel, considered as random quantities. The method Latin Hypercube Sampling was applied to evaluate statistical and sensitivity resistance analyses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity analysis and optimization of the nuclear fuel cycle

A sensitivity study has been conducted to assess the robustness of the conclusions presented in the MIT Fuel Cycle Study. The Once Through Cycle (OTC) is considered as the base-line case, while advanced technologies with fuel recycling characterize the alternative fuel cycles. The options include limited recycling in LWRs and full recycling in fast reactors and in high conversion LWRs. Fast reactor technologies studied include both oxide and metal fueled reactors. The analysis allowed optimization of the fast reactor conversion ratio with respect to desired fuel cycle performance characteristics. The following parameters were found to significantly affect the performance of recycling technologies and their penetration over time: Capacity Factors of the fuel cycle facilities, Spent Fuel Cooling Time, Thermal Reprocessing Introduction Date, and in core and Out-of-core TRU Inventory Requirements for recycling technology. An optimization scheme of the nuclear fuel cycle is proposed. Optimization criteria and metrics of interest for different stakeholders in the fuel cycle (economics, waste management, environmental impact, etc.) are utilized for two different optimization techniques (linear and stochastic). Preliminary results covering single and multi-variable and single and multi-objective optimization demonstrate the viability of the optimization scheme. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity analysis for dose deposition in radiotherapy via a Fokker–Planck model

In this paper, we study the sensitivities of electron dose calculations with respect to stopping power and transport coefficients. We focus on the application to radiotherapy simulations. We use a Fokker–Planck approximation to the Boltzmann transport equation. Equations for the sensitivities are derived by the adjoint method. The Fokker–Planck equation and its adjoint are solved numerically in slab geometry using the spherical harmonics expansion (P N ) and an Harten-Lax-van Leer finite volume method. Our method is verified by comparison to finite difference approximations of the sensitivities. Finally, we present numerical results of the sensitivities for the normalized average dose deposition depth with respect to the stopping power and the transport coefficients, demonstrating the increase in relative sensitivities as beam energy decreases. In conclusion, this in turn gives estimates on the uncertainty in the normalized average deposition depth, which we present.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗

A non-linear k-{epsilon} turbulent model sensitivity analysis for flow across a PWR spacer grid with mixing vanes

In this work we studied the sensitivity of different computational fluid dynamics (CFD) numerical solutions on turbulence model, domain discretization mesh type, and inlet boundary conditions. The case under examination is a turbulent one-phase flow (water) through a scaled nuclear pressurized water reactor (PWR) fuel assembly. The main feature of this geometrical configuration is the presence of a spacer grid with mixing vanes. The design of a spacer grid with mixing vanes plays a key role for the core heat transfer efficiency, increasing the coolant heat transfer coefficient. The main reason for this is the introduction of the top mixing vanes, which consist of an ordered repetitive succession of wings that generate secondary swirling flows. The increase of heat transfer efficiency also increases the critical heat flux (CHF), making it possible to increase the design and operational limits, far from boiling crises (departure of nucleate boiling in case of a PWR). The main focus of this work was to analyze the simulation capabilities of Reynolds-averaged Navier-Stokes (RANS) models (a cubic non-linear k-epsilon model formulation) for this complex flow geometry. The CFD code used was CD-Adapco STAR-CCM+.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

(U) Second-Order Sensitivity Analysis of Uncollided Particle Contributions to Radiation Detector Responses Using Ray-Tracing

The Second-Level Adjoint Sensitivity System (2nd-LASS) that yields the second-order sensitivities of a response of uncollided particles with respect to isotope densities, cross sections, and source emission rates is derived in Refs. 1 and 2. In Ref. 2, we solved problems for the uncollided leakage from a homogeneous sphere and a multiregion cylinder using the PARTISN multigroup discrete-ordinates code. In this memo, we derive solutions of the 2nd-LASS for the particular case when the response is a flux or partial current density computed at a single point on the boundary, and the inner products are computed using ray-tracing. Both the PARTISN approach and the ray-tracing approach are implemented in a computer code, SENSPG. The next section of this report presents the equations of the 1st- and 2nd-LASS for uncollided particles and the first- and second-order sensitivities that use the solutions of the 1st- and 2nd-LASS. Section III presents solutions of the 1st- and 2nd-LASS equations for the case of ray-tracing from a detector point. Section IV presents specific solutions of the 2nd-LASS and derives the ray-trace form of the inner products needed for second-order sensitivities. Numerical results for the total leakage from a homogeneous sphere are presented in Sec. V and for the leakage from one side of a two-region slab in Sec. VI. Section VII is a summary and conclusions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear data uncertainty and sensitivity analysis of the VHTRC benchmark using SCALE

The Very High Temperature Critical Assembly (VHTRC) experiment represents one of the few data sets available for the validation of HTGR lattice physics. Within the framework of the IAEA Coordinated Research Project on HTGR Uncertainty Analysis in Modeling, uncertainty and sensitivity analyses of this graphite-moderated facility are performed as the validation reference to the prismatic MHTGR-350 fuel block calculations. Nominal multi-group and continuous-energy criticality calculations with the KENO-VI Monte Carlo code of the SCALE code package are compared with the continuous-energy Monte Carlo Code Serpent. Good agreement with a maximum difference of 250 pcm is obtained. The experimental data set, however, differs by several hundred pcm with the results of both codes when using the ENDF-VII.0 library. When using ENDF/B-VII.1 data, this difference is reduced to a few hundred pcm and the calculations lie within the experimental error bars. Uncertainties of the VHTRC multiplication factors due to uncertainties in nuclear data are determined with SAMPLER/KENO-VI of SCALE 6.2 and with continuous-energy TSUNAMI of SCALE 6.2. For all experimental configurations, the obtained uncertainty is found to be 0.58% when using ENDF/B-VII.0 data. The top contributor to this uncertainty is the average number of neutrons per fission event of U-235. With ENDF/B-VII.1 data, uncertainties of about 0.66% are obtained in particular due to an increased uncertainty of U-235 nu-bar in the latest ENDF release. In conclusion, when considering these nuclear data uncertainties, the obtained 1s uncertainty intervals are overlapping with the experimental error bars.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗