Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURFACE CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

MARSAME Radiological Release Report for Metal Items from Technical Area 53, Set 28

Environmental Protection and Compliance, Environmental Stewardship Group (EPC-ES) has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) at Technical Area 53 (TA-53) and found that the metal items described in Table 1 of this report (identified by Radiation Protection [RP] Tracking Numbers) meet the criteria for unrestricted release under Department of Energy (DOE) Order 458.1 Chg 4, Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item in Attachment 1). Process knowledge indicates that items were released from radiological areas, including radiation areas, prior to the implementation of the 2000 metals moratorium. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from DOE facilities. Additionally, Los Alamos National Laboratory (LANL) has determined that there is no practical opportunity for internal DOE reuse of this metal. Process knowledge indicates that these metal items were unlikely to ever be in direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in depth showed no identifiable gamma radiation from beam activation.

61 RADIATION PROTECTION AND DOSIMETRY↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 22

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order458.1 Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal. Process knowledge indicates that these metal items were unlikely to ever bein direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in-depth showed no identifiable gamma radiation from beam activation.

36 MATERIALS SCIENCE↗

ORNLERASE - EPA COUNTS PER MINUTE CALCULATOR CONVERSION FACTORS

This database is used in the EPA's Superfund Counts Per Minute (CPM) Calculator (https://epa-cpm.ornl.gov/index.html). This database contains conversion factors used in the calculator that help users estimate the expected radiation detector reading, in counts per minute (CPM), corresponding to a measured radioactivity level reported in either pCi/cm² or pCi/g. Because surface contamination and volumetric contamination behave differently, the tool uses separate conversion processes, each based on Monte Carlo N-Particle (MCNP)–derived conversion factors. The CPM Calculator supports conversions for a range of common environmental media—including soil, steel, glass, drywall, concrete, and wood—to generate detector-ready CPM values. The primary goal of this tool is to enable more efficient, real-time field measurements, reducing reliance on laboratory analyses and ultimately saving both time and money during Superfund assessments.

Dolislager, Fred [ORNL] (ORCID:0009000325477921)↗

Wear studies made of slip rings and gas bearing components

Neutron activation analysis techniques were employed for the study of the wear and performance characteristics of slip ring and rotor assemblies and of the problems arising from environmental conditions with special reference to surface contamination. Results showed that the techniques could be successfully applied to measurement of wear parameters.

Furr, A. K.↗

The welding of Saturn V.

Welding techniques from Saturn 5 booster, discussing surface contamination effect on weld strength

Hoppes, R. V.↗

Improved fire resistant radio frequency anechoic materials

Protective, flameproof foam covering improves the resistance to fire and surface contamination of low-cost radio frequency absorbing and shielding anechoic materials. This promotes safety of operating personnel and equipment being tested in an otherwise combustible anechoic chamber.

Robinson, D. A.↗

Water/glycol temperature control circuit failed in the automatic mode: Apollo 16

An anomaly report concerning failure of the water/glycol temperature control circuit during the Apollo 16 flight is presented. The anomaly is described and diagrams of the system are presented. The malfunction was caused by cracked semiconductor chips in the output silicon-controlled rectifier. Surface contamination in the crack allowed the device to self-gate on and remain on, resulting in a secondary failure of the feedback capacitor.

Source record↗