Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Neutron-induced reactions in the hohlraum to study reaction in flight neutrons

We are currently developing the physics necessary to measure the Reaction In Flight (RIF) neutron flux from a NIF capsule. A measurement of the RIF neutron flux from a NIF capsule could be used to deduce the stopping power in the cold fuel of the NIF capsule. A foil irradiated at the Omega laser at LLE was counted at the LANL low-background counting facility at WIPP. The estimated production rate of {sup 195}Au was just below our experimental sensitivity. We have made several improvements to our counting facility in recent months. These improvements are designed to increase our sensitivity, and include installing two new low-background detectors, and taking steps to reduce noise in the signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4

Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H reaction). The study of investigating the capture process probability for neutron energy of 5.1 meV to 2.27 meV (4 - 6 A) is presented. - Alpha particles and tritons travel for a few microns in the scintillation material (α ∼0.007 mm, T ∼0.04 mm) losing energy and ionizing the ZnS. The mean free path of the two particles in each of the component materials and the complete compound was investigated. - The ionization of the ZnS(Ag) scintillation material produces blue light photons with luminescence wavelength of 450 nm. The amount of light output produced for different grain sizes of ZnS is discussed. - A large portion of the scintillation photons are reabsorbed during their passage through the scintillation material. - The blue photons that reach the WLS fibers are absorbed by fluorescent dye and are re-emitted as green photons, conducted by the fiber to the SiPM photo-sensor. This work presents the CANDOR unique design and its design constrains, the results measured by the ultra-thin {sup 6}LiF:ZnS(Ag)-based neutron detector versus the simulation results for several binder concentrations. The light measurement attenuation results along with the measured stopping power were utilized to predict the sensitivity results of configuration with different ZnS grain size, weight ratios and fibers geometry (number and location). The simulations enable to optimize the final sensor design. This design successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection of 80 percent. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of GRB Observations with the Suzaku Wideband All-sky Monitor

The Wide-band All-sky Monitor (WAM) is a made up of the large lateral BGO shield of the Hard X-ray Detector (HXD) onboard Suzaku. Its large geometrical area of 800 cm{sup 2} per side, the large stopping power for the hard X-rays and the wide-field of view make the WAM an ideal detector for gamma-ray bursts (GRBs) observations in the energy range of 50-5000 keV. In fact, the WAM has observed 288 GRBs confirmed by other satellites, till the end of May 2007.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for Stopped Gluinos at CMS

We describe plans for a search for long-lived particles which will become stopped by the CMS detector. We will look for the subsequent decay of these particles during time intervals where there are no pp collisions in CMS: during gaps between crossings in the LHC beam structure, and during inter-fill periods between the beam being dumped and re-injection. Such long living particles decays will be recorded with dedicated calorimeter triggers. For models predicting these particles, such as split-susy gluinos, the large cross-section combined with good stopping power of CMS, yields a significant number of triggerable decays. If LHC instantaneous luminosity approaches 10{sup 32} cm{sup -2}s{sup -1} in 2009-10, 5sigma significance can be established in a matter of days, since these decays occur on top of a negligible background.Due to limited size, this paper concentrates on main idea and expected results. More details are available in https://twiki.cern.ch/twiki/bin/view/CMS/PhysicsResults.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of Coulomb coupling on friction in strongly magnetized plasmas

The friction force on a test particle traveling through a plasma that is both strongly coupled and strongly magnetized is studied using molecular dynamics simulations. In addition to the usual stopping power component aligned antiparallel to the velocity, a transverse component that is perpendicular to both the velocity and Lorentz force is observed. This component, which was recently discovered in weakly coupled plasmas, is found to increase in both absolute and relative magnitude in the strongly coupled regime. Strong coupling is also observed to induce a third component of the friction force in the direction of the Lorentz force. These first-principles simulations reveal novel physics associated with collisions in strongly coupled, strongly magnetized, plasmas that are not predicted by existing kinetic theories. The effect is expected to influence macroscopic transport in a number of laboratory experiments and astrophysical plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Roles of deformation and orientation in heavy-ion collisions induced by light deformed nuclei at intermediate energy

The reaction dynamics of axisymmetric deformed {sup 24}Mg+{sup 24}Mg collisions has been investigated systematically by an isospin-dependent quantum molecular dynamics model. It is found that different deformations and orientations result in apparently different properties of reaction dynamics. We reveal that some observables such as nuclear stopping power (R), multiplicity of fragments, and elliptic flow are very sensitive to the initial deformations and orientations. There exists an eccentricity scaling of elliptic flow in central body-body collisions with different deformations. In addition, the tip-tip and body-body configurations turn out to be two extreme cases in central reaction dynamical process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angular distribution of Cherenkov radiation from relativistic heavy ions taking into account deceleration in the radiator

Numerical methods are used to study the dependence of the structure and the width of the angular distribution of Vavilov-Cherenkov radiation with a fixed wavelength in the vicinity of the Cherenkov cone on the radiator parameters (thickness and refractive index), as well as on the parameters of the relativistic heavy ion beam (charge and initial energy). The deceleration of relativistic heavy ions in the radiator, which decreases the velocity of ions, modifies the condition of structural interference of the waves emitted from various segments of the trajectory; as a result, a complex distribution of Vavilov-Cherenkov radiation appears. The main quantity is the stopping power of a thin layer of the radiator (average loss of the ion energy), which is calculated by the Bethe-Bloch formula and using the SRIM code package. A simple formula is obtained to estimate the angular distribution width of Cherenkov radiation (with a fixed wavelength) from relativistic heavy ions taking into account the deceleration in the radiator. The measurement of this width can provide direct information on the charge of the ion that passes through the radiator, which extends the potentialities of Cherenkov detectors. The isotopic effect (dependence of the angular distribution of Vavilov-Cherenkov radiation on the ion mass) is also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaction-in-flight neutrons as a signature for shell mixing in National Ignition Facility capsules

Analytic calculations and results from computational simulations are presented that suggest that reaction-in-flight (RIF) neutrons can be used to diagnose mixing of the ablator shell material into the fuel in deuterium-tritium (DT) capsules designed for the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)]. Such mixing processes in NIF capsules are of fundamental physical interest and can have important effects on capsule performance, quenching the total thermonuclear yield. The sensitivity of RIF neutrons to hydrodynamical mixing arises through the dependence of RIF production on charged-particle stopping lengths in the mixture of DT fuel and ablator material. Since the stopping power in the plasma is a sensitive function of the electron temperature and density, it is also sensitive to mix. RIF production scales approximately inversely with the degree of mixing taking place, and the ratio of RIF to down-scattered neutrons provides a measure of the mix fraction and/or the mixing length. For sufficiently high-yield capsules, where spatially resolved RIF images may be possible, neutron imaging could be used to map RIF images into detailed mix images.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase transformations induced by high electronic excitation in ion-irradiated Gd{sub 2}(Zr{sub x}Ti{sub 1-x}){sub 2}O{sub 7} pyrochlores

The pyrochlore oxides (A{sub 2}B{sub 2}O{sub 7}) exhibit a remarkable range of structural, physical, and magnetic properties related to their various chemical compositions. This article reports the phase transformations induced by high electronic excitation in pyrochlores of the Gd{sub 2}(Zr{sub x}Ti{sub 1-x}){sub 2}O{sub 7} family irradiated with swift ions. The structural changes, investigated by using several analytical techniques (x-ray diffraction, Raman spectroscopy, and transmission electron microscopy), strongly depend on the chemical composition. The high electronic excitation along the ion trajectory results in the amorphization of ion tracks for Gd{sub 2}Ti{sub 2}O{sub 7} and Gd{sub 2}TiZrO{sub 7}, whereas a defective fluorite structure is formed in Gd{sub 2}Zr{sub 2}O{sub 7}. Moreover, the results underline the existence of an electronic stopping power threshold of 6 keV/nm for amorphizable compounds and 10 keV/nm for Gd{sub 2}Zr{sub 2}O{sub 7}, below which phase transformations do not occur. Finally, the study of the thermal recovery of irradiated pyrochlores provides the recrystallization temperature for amorphized samples and reveals differences in the recovery process which are related to the chemical composition.

36 MATERIALS SCIENCE↗

Updated S factors for the {sup 7}Be(p,{gamma}){sup 8}B reaction

We present revised {sup 7}Be(p,{gamma}){sup 8}B S factors based on our previously published measurements, using a more detailed target analysis and improved stopping powers. Extrapolating our data below the 1{sup +} resonance to solar energies using the latest cluster model calculations of Descouvemont, we find that S{sub 17}(0)=21.5+-0.6(expt) +- 0.7(theor) eV b. Fitting all modern, low-energy (p,{gamma}) data with the same theory, we find a 'best' value of S{sub 17}(0)=20.9+-0.6(expt) +- 0.7(theor) eV b.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommendations for clinical electron beam dosimetry: Supplement to the recommendations of Task Group 25

The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance testing and treatment planning of new accelerators with therapeutic electron beams. Since the publication of the TG-25 report, significant advances have taken place in the field of electron beam dosimetry, the most significant being that primary standards laboratories around the world have shifted from calibration standards based on exposure or air kerma to standards based on absorbed dose to water. The AAPM has published a new calibration protocol, TG-51, for the calibration of high-energy photon and electron beams. The formalism and dosimetry procedures recommended in this protocol are based on the absorbed dose to water calibration coefficient of an ionization chamber at {sup 60}Co energy, N{sub D,w}{sup 60{sub C}{sub o}}, together with the theoretical beam quality conversion coefficient k{sub Q} for the determination of absorbed dose to water in high-energy photon and electron beams. Task Group 70 was charged to reassess and update the recommendations in TG-25 to bring them into alignment with report TG-51 and to recommend new methodologies and procedures that would allow the practicing medical physicist to initiate and continue a high quality program in clinical electron beam dosimetry. This TG-70 report is a supplement to the TG-25 report and enhances the TG-25 report by including new topics and topics that were not covered in depth in the TG-25 report. These topics include procedures for obtaining data to commission a treatment planning computer, determining dose in irregularly shaped electron fields, and commissioning of sophisticated special procedures using high-energy electron beams. The use of radiochromic film for electrons is addressed, and radiographic film that is no longer available has been replaced by film that is available. Realistic stopping-power data are incorporated when appropriate along with enhanced tables of electron fluence data. A larger list of clinical applications of electron beams is included in the full TG-70 report available at http://www.aapm.org/pubs/reports. Descriptions of the techniques in the clinical sections are not exhaustive but do describe key elements of the procedures and how to initiate these programs in the clinic. There have been no major changes since the TG-25 report relating to flatness and symmetry, surface dose, use of thermoluminescent dosimeters or diodes, virtual source position designation, air gap corrections, oblique incidence, or corrections for inhomogeneities. Thus these topics are not addressed in the TG-70 report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mathematical modeling of gas-dynamic and radiative processes in experiments with the use of laser and heavy-ion beams

Results are presented from theoretical and experimental studies of gas-dynamic and radiative processes in the plasma that is planned to be used in future experiments on the stopping of fast heavy-ion beams. These experiments are aimed at measuring the enhanced (as compared to cold substance) plasma stopping power. To reliably interpret the experimental results, it is necessary to create a hydrodynamically stable homogeneous plasma with a uniform temperature and a lifetime exceeding the transit time of the heavy-ion beam (3–5 ns). The method for calculating plasma gas-dynamic characteristics with allowance for radiative heat transfer is described. The specific features of the so-called ion model of plasma, which is used to calculate plasma radiative characteristics, are discussed. The emission spectrum formed as a result of conversion of laser radiation into X-rays and the subsequent passing through a triacetate cellulose (C{sub 12}H{sub 16}O{sub 8}) target is calculated. The simulated spectrum of transmitted radiation satisfactorily agrees with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Beam Facility at the University of Chile; Applications and Basic Research

The main characteristics of the ion beam facility based on a 3.75 MeV Van de Graaff accelerator at the University of Chile are described at this work. Current activities are mainly focused on the application of the Ion Beam Analysis techniques for environmental, archaeological, and material science analysis. For instance, Rutherford Backscattering Spectrometry (RBS) is applied to measure thin gold film thickness which are used to determine their resistivity and other electrical properties. At this laboratory the Proton Induced X-Ray Emission (PIXE) and Proton Elastic Scattering Analysis (PESA) methodologies are extensively used for trace element analysis of urban aerosols (Santiago, Ciudad de Mexico). A similar study is being carried out at the Antarctica Peninsula. Characterization studies on obsidian and vitreous dacite samples using PIXE has been also perform allowing to match some of these artifacts with geological source sites in Chile.Basic physics research is being carried out by measuring low-energy cross section values for the reactions {sup 63}Cu(d,p){sup 64}Cu and {sup Nat}Zn(p,x){sup 67}Ga. Both radionuclide {sup 64}Cu and {sup 67}Ga are required for applications in medicine. Ongoing stopping power cross section measurements of proton and alphas on Pd, Cu, Bi and Mylar are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technical Note: On the proton range and nuclear interactions in compounds and mixtures

Purpose: Range and probability of nonelastic nuclear interactions (NNIs) for protons can be found only for a limited number of compounds and mixtures in nuclear data tables, and the proton-related analytical studies are therefore restricted to those materials for which the data are provided in these documents. In this paper, the authors present general solutions for calculating the proton range and probability of NNIs for desired compounds and mixtures. Methods: Benefiting from the Bragg–Kleeman approximation of mass stopping power, the authors derive a concise formula for calculating the proton range in materials with arbitrary number of constituent elements. Additionally, the authors propose another relation for obtaining the probability of undergoing NNIs which is suggested to be additive. Results: The examination of the formula presented shows that the authors’ method can be considered as general solutions for analytical evaluation of the range in compounds and mixtures. The formula proposed for probability of NNIs is valid for almost every compound except for those materials containing H. It is shown that this formula can be modified so that it covers these materials. Conclusions: The authors present a general analytical method for calculating the range and probability of NNIs for protons which are mathematically easy to handle and valid for desired compounds or mixtures composed of an arbitrary number of constituent elements, including materials of interest for proton radiotherapy purposes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New reaction rate for {sup 16}O(p,{gamma}){sup 17}F and its influence on the oxygen isotopic ratios in massive AGB stars

The {sup 16}O(p,{gamma}){sup 17}F reaction rate is revisited with special emphasis on the stellar temperature range of T=60-100 MK, important for hot bottom burning in asymptotic giant branch (AGB) stars. We evaluate existing cross-section data that were obtained since 1958 and, if appropriate, correct published data for systematic errors that were not noticed previously, including the effects of coincidence summing and updated effective stopping powers. The data are interpreted by using two different models of nuclear reactions, that is, a potential model and R-matrix theory. A new astrophysical S factor and recommended thermonuclear reaction rates are presented. As a result of our work, the {sup 16}O(p,{gamma}){sup 17}F reaction has now the most precisely known rate involving any target nucleus in the mass A{>=}12 range, with reaction rate errors of about 7% over the entire temperature region of astrophysical interest (T=0.01-2.5 GK). The impact of the present improved reaction rate with its significantly reduced uncertainties on the hot bottom burning in AGB stars is discussed. In contrast to earlier results we find now that there is not clear evidence to date for any stellar grain origin from massive AGB stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-350: Effective Point of Measurement and Total Perturbation Correction P for Parallel-Plate Ion Chambers in High-Energy Photon Beams

Purpose: This paper aims to determine the effective point of measurement and the total perturbation correction p of parallel-plate chambers for clinical photon dosimetry. Methods: The effective point of measurement (EPOM) was calculated using the EGSnrc Monte Carlo code system with the EGSnrc user code egs- chamber. Depth dose curves of the ionization chambers were calculated in a water phantom for several high energy photon spectra (4, 6, 10, 15, 18 MV-X). Different normalization criterions (normalization to the maximum of the depth dose curve and normalization to the value in 10 cm depth) have been applied. The EPOM was determined by shifting the normalized depth dose curve of a small water voxel against the depth ionization curve until the disagreement (calculated by the root mean square deviation) reaches a minimum. In addition, the total perturbation correction p was calculated by the ratio of the dose to water and the product of the dose determined in the chamber and the water to air stopping power ratio. Results: The EPOM varied slightly depending on the chosen normalization criterion. For all chambers the necessary shift of the EPOM decreased linearly with increasing beam quality specifier TPR{sub 20/10}. For the Roos and NACP chamber, the results were positive suggesting that the chambers need to be shifted towards the focus. For the Markus chamber, the required shift was negative and for the Advanced Markus chamber partly negative and partly positive. The total perturbation correction p was almost independent of the depth. Only for regions below 1 cm the perturbation correction deviated significantly from unity. Conclusion: In the present study, the effective point of measurement and the total perturbation correction p was determined for four parallel-plate ionization chambers and five clinical relevant photon spectra. Applying the calculated EPOM, the residual perturbation correction p was mostly depth independent.

60 APPLIED LIFE SCIENCES↗

Fission-Fusion: A new reaction mechanism for nuclear astrophysics based on laser-ion acceleration

We propose to produce neutron-rich nuclei in the range of the astrophysical r-process around the waiting point N = 126 by fissioning a dense laser-accelerated thorium ion bunch in a thorium target (covered by a CH{sub 2} layer), where the light fission fragments of the beam fuse with the light fission fragments of the target. Via the 'hole-boring' mode of laser Radiation Pressure Acceleration using a high-intensity, short pulse laser, very efficiently bunches of {sup 232}Th with solid-state density can be generated from a Th target and a deuterated CD{sub 2} foil, both forming the production target assembly. Laser-accelerated Th ions with about 7 MeV/u will pass through a thin CH{sub 2} layer placed in front of a thicker second Th foil (both forming the reaction target) closely behind the production target and disintegrate into light and heavy fission fragments. In addition, light ions (d,C) from the CD{sub 2} layer of the production target will be accelerated as well, inducing the fission process of {sup 232}Th also in the second Th layer. The laser-accelerated ion bunches with solid-state density, which are about 10{sup 14} times more dense than classically accelerated ion bunches, allow for a high probability that generated fission products can fuse again. The high ion beam density may lead to a strong collective modification of the stopping power, leading to significant range and thus yield enhancement. Using a high-intensity laser as envisaged for the ELI-Nuclear Physics project in Bucharest (ELI-NP), order-of-magnitude estimates promise a fusion yield of about 10{sup 3} ions per laser pulse in the mass range of A = 180-190, thus enabling to approach the r-process waiting point at N = 126.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗