Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STACKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Identifying different stacking sequences in few-layer CVD-grown Mo S 2 by low-energy atomic-resolution scanning transmission electron microscopy

We present that atomically thin MoS 2 grown by chemical vapor deposition (CVD) is a promising candidate for next-generation electronics due to inherent CVD scalability and controllability. However, it is well known that the stacking sequence in few-layer MoS 2 can significantly impact electrical and optical properties. Herein we report different intrinsic stacking sequences in CVD-grown few-layer MoS 2 obtained by atomic-resolution annular-dark-field imaging in an aberration-corrected scanning transmission electron microscope operated at 50 keV. Trilayer MoS 2 displays a new stacking sequence distinct from the commonly observed 2H and 3R phases of MoS 2 . Finally, density functional theory is used to examine the stability of different stacking sequences, and the findings are consistent with our experimental observations.

36 MATERIALS SCIENCE↗

Thermal cycling induced alteration of the stacking order and spin-flip in the room temperature van der Waals magnet Fe 5 GeTe 2

The magnetic properties of the quasi-two-dimensional van der Waals magnet Fe 5–δ GeTe 2 (F5GT), which has a high ferromagnetic ordering temperature T C ~315 K, remain to be better understood. It has been demonstrated that the magnetization of F5GT is sensitive to both the Fe deficiency δ and the thermal-cycling history. Here, we investigate the structural and magnetic properties of F5GT single crystals with a minimal Fe deficiency (|δ |≤ 0.1), utilizing combined x-ray and neutron scattering techniques. Herein our study reveals that the quenched F5GT single crystals experience an irreversible, first-order transition at T S ~110 K upon first cooling, where the stacking order partly or entirely converts from ABC-stacking order to AA-stacking order. Importantly, the magnetic properties, including the magnetic moment direction and the enhanced T C after the thermal cycling, are intimately related to the alteration of the stacking order. Our work highlights the significant influence of the lattice symmetry to the magnetism in F5GT.

2-dimensional systems↗

FPGA-Based Optical Cavity Phase Stabilization for Coherent Pulse Stacking

Coherent pulse stacking (CPS) is a new time-domain coherent addition technique that stacks several optical pulses into a single output pulse, enabling high pulse energy from fiber lasers. We develop a robust, scalable, and distributed digital control system with firmware and software integration for algorithms, to support the CPS application. We model CPS as a digital filter in the Z domain and implement a pulse-pattern-based cavity phase detection algorithm on an field-programmable gate array (FPGA). A two-stage (2+1 cavities) 15-pulse stacking system achieves an 11.0 peak-power enhancement factor. Each optical cavity is fed back at 1.5kHz, and stabilized at an individually-prescribed round-trip phase with 0.7deg and 2.1deg rms phase errors for Stages 1 and 2, respectively. Optical cavity phase control with nanometer accuracy ensures 1.2% intensity stability of the stacked pulse over 12 h. The FPGA-based feedback control system can be scaled to large numbers of optical cavities.

43 PARTICLE ACCELERATORS↗

HAM: Hotspot-Aware Manager for Improving Communications with 3D-Stacked Memory

merging High-Performance Computing (HPC) workloads, such as graph analytics, machine learning, and big data science, are data-intensive. Data-intensive workloads usually present fine-grained memory accesses with limited or no data locality, and thus incur frequent cache misses and low utilization of memory bandwidth. 3D-stacked memory devices such as Hybrid Memory Cube (HMC) and High Bandwidth Memory (HBM) can provide significantly higher bandwidth than conventional memory modules. However, the traditional interfaces and optimization methods for JEDEC DDR devices do not allow to fully exploit the potential performance of 3D-stacked memory with the massive amount of irregular memory accesses of data-intensive applications. In this paper, we propose a novel Hotspot-Aware Manager (HAM) infrastructure for 3D-stacked memory devices capable of optimizing memory access streams via request aggregation, hotspot detection, and in-memory prefetching. %and an associated hotspot-aware page policy. We present the HAM design and implementation, and simulate it on a system using RISC-V embedded cores with attached HMC devices. We extensively evaluate HAM with over 12 benchmarks and applications representing diverse irregular memory access patterns. The results show that, on average, HAM reduces redundant requests by 37.51\% and increases the prefetch buffer hit rate by 4.2 times, compared to a baseline streaming prefetcher. On the selected benchmark set, HAM provides performance gains of 21.81\% in average (up to 34.28\%) and power savings of 35.07\% over a standard 3D-stacked memory.

Wang, Xi↗

Mechanisms for plasma etching of HfO{sub 2} gate stacks with Si selectivity and photoresist trimming

To minimize leakage currents resulting from the thinning of the insulator in the gate stack of field effect transistors, high-dielectric constant (high-k) metal oxides, and HfO{sub 2} in particular, are being implemented as a replacement for SiO{sub 2}. To speed the rate of processing, it is desirable to etch the gate stack (e.g., metal gate, antireflection layers, and dielectric) in a single process while having selectivity to the underlying Si. Plasma etching using Ar/BCl{sub 3}/Cl{sub 2} mixtures effectively etches HfO{sub 2} while having good selectivity to Si. In this article, results from integrated reactor and feature scale modeling of gate-stack etching in Ar/BCl{sub 3}/Cl{sub 2} plasmas, preceded by photoresist trimming in Ar/O{sub 2} plasmas, are discussed. It was found that BCl{sub n} species react with HfO{sub 2}, which under ion impact, form volatile etch products such as B{sub m}OCl{sub n} and HfCl{sub n}. Selectivity to Si is achieved by creating Si-B bonding as a precursor to the deposition of a BCl{sub n} polymer which slows the etch rate relative to HfO{sub 2}. The low ion energies required to achieve this selectivity then challenge one to obtain highly anisotropic profiles in the metal gate portion of the stack. Validation was performed with data from literature. The effect of bias voltage and key reactant probabilities on etch rate, selectivity, and profile are discussed.

36 MATERIALS SCIENCE↗

Stacked-mosaic amplifier and diode delivery concept for kJ-class inertial fusion energy laser driver

We report on a laser amplifier architecture designed as a modular element for scaling to multi-megajoule laser facilities intended for inertial fusion energy (IFE) power plants. This kilojoule-class module features a stacked mosaic of gain media integrated with a diode delivery system for efficient optical pumping of the mosaic-structured gain medium, enabling high-repetition-rate operation at high wall plug efficiencies, necessary for an IFE driver. Details of a diode delivery system capable of pumping the mosaic architecture are presented. Comprehensive numerical modeling demonstrates that the stacked-mosaic approach reduces transverse gain by five orders of magnitude compared to a conventional full-aperture Yb:YAG based amplifier, substantially suppressing transverse amplified spontaneous emission (TASE) and enabling enhanced longitudinal energy extraction. Detailed analysis of thermal management and wavefront distortion in a 4 × 4 mosaic array indicates that temperature gradients and thermally induced aberrations are effectively controlled using gas cooling and commercially available phase-plate and deformable mirror technologies. We further discuss the applicability of a stacked-mosaic architecture to direct-drive IFE schemes, where broad spectral bandwidth is critical, and its compatibility with frequency conversion modules for up-conversion to blue wavelengths. Finally, an example point design for a 10 kJ, 10 Hz Yb:YAG module operating at 175 K with wall-plug efficiency exceeding 10 % is presented, underscoring the feasibility of this approach for next-generation high-energy lasers for IFE drivers. The results establish the stacked-mosaic amplifier as a scalable, robust platform not only for IFE but also for a broad range of advanced scientific and industrial laser applications.

Lasers↗

Stacked filters: learning to filter by structure

We present Stacked Filters, a new probabilistic filter which is fast and robust similar to query-agnostic filters (such as Bloom and Cuckoo filters), and at the same time brings low false positive rates and sizes similar to classifier-based filters (such as Learned Filters). The core idea is that Stacked Filters incorporate workload knowledge about frequently queried non-existing values. Instead of learning, they structurally incorporate that knowledge using hashing and several sequenced filter layers, indexing both data and frequent negatives. Stacked Filters can also gather workload knowledge on-the-fly and adaptively build the filter. We show experimentally that for a given memory budget, Stacked Filters achieve end-to-end query throughput up to 130x better than the best alternative for a workload, either query-agnostic or classifier-based filters, and depending on where data is (SSD or HDD).

Computer Science↗

Assessment of the Group 3-4 (HV-S1, HV-S2, IHLW-S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 3-4 exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The HV-S1, HV-S2, and IHLW-S1 exhaust stacks were tested together as a group (Test Group 3-4) because they share a geometric attribute: the common factor in their design is that the last significant flow disturbance upstream of the air sampling probe is a jog (i.e., two conjoined bends of equal and opposite curvature resulting in a change in elevation of the duct). Federal regulations require that a sampling probe be located in the exhaust stack according to criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Glissmeyer, John A.↗

Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Glissmeyer, John A.↗

Assessment of the National Research Universal Reactor Proposed New Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mercury Dispersion Modeling And Purge Ventilation Stack Height Determination For Tank 40H

The SRNL Atmospheric Technologies Group performed an analysis for mercury emissions from H-Tank Farm - Tank 40 ventilation system exhaust in order to assess whether the Short Term Exposure Limit (STEL), or Threshold Limit Value (TLV) levels for mercury will be exceeded during bulk sludge slurry mixing and sludge removal operations. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the main dispersion modelling tool for this analysis. The results indicated that a 45-foot stack is sufficient to raise the plume centerline from the Tank 40 release to prevent mercury exposure problems for any of the stack discharge scenarios provided. However, a 42-foot stack at Tank 40 is sufficient to prevent mercury exposure concerns in all emission scenarios except the 50 mg/m 3 release. At a 42-foot stack height, values exceeding the exposure standards are only measured on receptors located above 34 feet.

54 ENVIRONMENTAL SCIENCES↗

Open stack thermal battery tests

We present selected results from a series of Open Stack thermal battery tests performed in FY14 and FY15 and discuss our findings. These tests were meant to provide validation data for the comprehensive thermal battery simulation tools currently under development in Sierra/Aria under known conditions compared with as-manufactured batteries. We are able to satisfy this original objective in the present study for some test conditions. Measurements from each test include: nominal stack pressure (axial stress) vs. time in the cold state and during battery ignition, battery voltage vs. time against a prescribed current draw with periodic pulses, and images transverse to the battery axis from which cell displacements are computed. Six battery configurations were evaluated: 3, 5, and 10 cell stacks sandwiched between 4 layers of the materials used for axial thermal insulation, either Fiberfrax Board or MinK. In addition to the results from 3, 5, and 10 cell stacks with either in-line Fiberfrax Board or MinK insulation, a series of cell-free “control” tests were performed that show the inherent settling and stress relaxation based on the interaction between the insulation and heat pellets alone.

25 ENERGY STORAGE↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 31H

The SRNL Atmospheric Technologies Group performed an analysis of mercury emissions from the H-Tank Farm Tank 31-H to assess worst case 15-minute, 1-hour and 8-hour average concentrations and evaluate whether the ACIGH Short-Term Exposure Limit (STEL), PAC (Protection Action Criteria), or Threshold Limit Value (TLV) levels for mercury are exceeded. This analysis was also used to establish a minimum stack height at which ambient mercury concentration would not exceed the regulatory limits. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. The PAC standard is not exceeded for any of the stack heights, or release scenario. A 92 ft stack for the 25 mg/m 3 modeling scenario and 95 ft for the 50 mg/m 3 are necessary to prevent all exceedances at all receptors. If the highest receptor on the Evaporator West Stack Platform is excluded from the domain, then the maximum heights are 35 ft and 52 ft for the 25 mg/m 3 and the 50 mg/m 3 modeling scenarios, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 35H Bulk Sludge Removal

The SRNL Atmospheric Technologies Group performed an analysis of mercury emissions from the H-Tank Farm Tank 35-H to assess worst case 15-minute, 1-hour and 8-hour average concentrations and evaluate whether the ACIGH Short-Term Exposure Limit (STEL), PAC (Protection Action Criteria), or Threshold Limit Value (TLV) levels for mercury are exceeded. This analysis was also used to establish a minimum stack height at which ambient mercury concentration would not exceed the regulatory limits. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. The PAC standard is not exceeded for any of the stack heights, or release scenario. A 100 ft stack for the 50 mg/m 3 modeling scenario and 110 ft for the 100 mg/m3 are necessary to prevent all exceedances at all receptors. If the highest receptor on the Evaporator West Stack Platform is excluded from the domain, then the maximum heights are 65 ft and 105 ft for the 50 mg/m 3 and the 100 mg/m 3 modeling scenarios, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 42H

The Savannah River National Laboratory (SRNL) Atmospheric Technologies Group performed atmospheric dispersion modeling and analysis of mercury emissions from the H-Tank Farm - Tank 42 ventilation system exhaust to evaluate potential worker exposures to mercury vapor. This analysis was used to establish a minimum stack height at which ambient mercury concentration would not exceed any worker exposure limit. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. Results indicate that the default 10-foot stack results in ground level concentrations that significantly exceed exposure standards for the mercury discharge scenarios evaluated. For a discharge of 25 mg/m 3 , a 50-foot stack was necessary to raise the exhaust plume centerline from Tank 42H to a height that prevents mercury exposure problems for elevated receptors on buildings near the tank. If the discharge concentration is decreased to 10 mg/m 3 , the minimum stack height required to comply with exposure limits is of 40 feet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stacked Greenfield and Brownfield ROZ Fairways in the Illinois Basin Geo-Laboratory: Co-Optimization of EOR and Associated CO 2 Storage

Residual oil zones (ROZs) are economically viable targets for carbon dioxide enhanced oil recovery (CO 2 -EOR); thick, carbonate ROZs in the San Andres Formation in the Wasson Field of the Permian Basin are an example. Incremental oil produced from CO 2 -EOR can be carbon negative via associated storage of injected CO 2 . Given the regional extent of ROZ fairways and generally higher net utilization of CO 2 (compared to conventional CO 2 -EOR), ROZs provide the opportunity for significant carbon neutral to carbon negative oil production with associated CO 2 storage, and therefore should be a priority target for exploration. However, ROZs have not been widely recognized or identified due to poor or no conventional oil production. Hence, in places like the Illinois Basin (ILB), exploratory analyses are required to recognize the existence of an ROZ. As part of this study, four formations were selected for detailed regional characterization and analysis: Carper Sandstone (part of the Borden Siltstone), Tar Springs Sandstone, Cypress Sandstone, and Middle Devonian (Geneva Dolomite and associated Dutch Creek Sandstone). The four formations underwent regional geological characterization to develop a regional geologic framework for the ROZs and their overlying seals. Findings of this study are supported by data from two field laboratory sites, one with stacked greenfield ROZs and the other with a stacked complex that includes a brownfield ROZ and depleted conventional reservoirs. The field laboratory sites were used to collect data and conduct tests to validate ROZ detection methodologies and identify economic field-deployable strategies to co-optimize CO 2 -EOR and associated storage in stacked ROZs. Findings from these field sites were extrapolated to characterize the basin-wide stacked ROZ fairway resource.

01 COAL, LIGNITE, AND PEAT↗

Summary of Stack Tests at TA-16-Bldg 205: Horizontal Duct on WETF Roof

In late 2023 and early 2024, testing was done at the Weapons Engineering Tritium Facility (WETF) rooftop exhaust duct to verify that the stack sample location was in compliance with the ANSI standard for stack sampling, ANSI N13.1-1999. This ANSI standard is called out by the Clean Air Act rules for airborne radionuclide emissions from DOE facilities, 40 CFR 61 Subpart H. This sample location is designated 16020504, indicating Technical Area 16, Building 0205. The rooftop duct formerly discharged to Exhaust Stack 04, but in 2007 it was re-routed to exhaust out Building 0450, Exhaust Stack 05. For continuity, we have kept the 16020504 designation to represent this duct sample location.

54 ENVIRONMENTAL SCIENCES↗