Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Application of Model Reference Adaptive Control System to Instrument Pointing System /IPS/

A Model Reference Adaptive Controller (MRAC) is derived for a Shuttle payload called the Instrument Pointing System (IPS). The unique features of this MRAC design are that total state feedback is not required, that the internal structure of the model is independent of the internal structure of the IPS, and that the model input is of bounded variation and not required a priori. An application of Liapunov's stability theorems is used to synthesize a control signal which assures MRAC asymptotic stability. Exponential observers are used to obtain the necessary state information to implement the control synthesis. Results are presented which show how effectively the MRAC can maneuver the IPS.

Waites, H. B.↗

Stabilizing Microwave Frequency of a Photonic Oscillator

A scheme for stabilizing the frequency of a microwave signal is proposed that exploits the operational characteristics of a coupled optoelectronic oscillator (COEO) and related optoelectronic equipment. An essential element in the scheme is a fiber mode-locked laser (MLL), the optical frequency of which is locked to an atomic transition. In this scheme, the optical frequency stability of the mode-locked laser is transferred to that of the microwave in the same device. Relative to prior schemes for using wideband optical frequency comb to stabilize microwave signals, this scheme is simpler and lends itself more readily to implementation in relatively compact, rugged equipment. The anticipated development of small, low-power, lightweight, highly stable microwave oscillators based on this scheme would afford great benefits in communication, navigation, metrology, and fundamental sciences. COEOs of various designs, at various stages of development, in some cases called by different names, have been described in a number of prior NASA Tech Briefs articles. A COEO is an optoelectronic apparatus that generates both short (picosecond) optical pulses and a steady microwave signal having an ultrahigh degree of spectral purity. The term "coupled optoelectronic" in the full name of such an apparatus signifies that its optical and electronic oscillations are coupled to each other in a single device. The present frequency-stabilization scheme is best described indirectly by describing the laboratory apparatus used to demonstrate it. The apparatus (see figure) includes a COEO that generates a comb-like optical spectrum, the various frequency components of which interfere, producing short optical pulses. This spectrum is centered at a nominal wavelength of 1,560 nm. The spectrum separation of this comb is about 10 GHz, as determined primarily by the length of an optical loop and the bandpass filter in the microwave feedback loop. The optical loop serves as microwave resonator having a very high value of the resonance quality factor (Q). The optical frequency of MLL is then stabilized by locking it to an atomic transition as described below. The COEO contains a tunable 1-nm band-pass optical filter and a piezoelectric-transducer (PZT) drum over which a stretch of fiber is wound. The 1-nm-wide pass band of the filter provides coarse tuning to overlap the frequency comb with the atomic transition frequency. Controlled stretching of the fiber by means of the PZT drum can be used in conjunction with temperature control for locking the laser frequency. To reference to an atomic resonance at 780 nm in this demonstration setup, the optical output of the COEO at 1,560 nm is fed through an erbium-doped-fiber amplifier (EDFA) to a frequency doubler in the form of a periodically poled lithium niobate (PPLN) crystal. The frequency-doubled output is combined with the output of a separate frequency-stabilized diode laser at a photodetector. As described thus far, the two 780-nm laser subsystems are nominally independent of each other and can, therefore, operate at different frequencies. Hence, at the photodetector, the two laser beams interfere, so that the output of the photodetector includes a beat note (a component at the difference between the two laser frequencies).

Maleki, Lute↗

Application of high stability oscillators to radio science experiments using deep space probes

The microwave telecommunication links between the earth and deep space probes have long been used to conduct radio science experiments which take advantage of the phase coherency and stability of these links. These experiments measure changes in the phase delay of the signals to infer electrical, magnetic and gravitational properties of the solar system environment and beyond through which the spacecraft and radio signals pass. The precision oscillators, from which the phase of the microwave signals are derived, play a key role in the stability of these links and therefore the sensitivity of these measurements. These experiments have become a driving force behind recent and future improvements in the Deep Space Network and spacecraft oscillators and frequency and time distribution systems. Three such experiments which are key to these improvements are briefly discussed and relationship between their sensitivity and the signal phase stability is described. The first is the remote sensing of planetary atmospheres by occultation in which the radio signal passes through the atmosphere and is refracted causing the signal pathlength to change from which the pressure and the temperature of the atmosphere can be derived. The second experiment is determination of the opacity of planetary rings by passage of the radio signals through the rings. The third experiment is the research for very low frequency gravitational radiation. The fractional frequency variation of the signal is comparable to the spatial strain amplitude the system is capable of detecting. A summary of past results and future possibilities for these experiments are presented.

Kursinski, Emil R.↗

Microplasma source for optogalvanic spectroscopy of nanogram samples

The demand for analysis of smaller samples in isotopic ratio measurements of rare isotopes is continuously rising with the development of new applications, particularly in biomedicine. Interesting in this aspect are methods based on optogalvanic spectroscopy, which have been reported to facilitate both {sup 13}C-to-{sup 12}C and {sup 14}C-to-{sup 12}C ratio measurements with high sensitivity. These methods also facilitate analysis of very small samples, down to the microgram range, which makes them very competitive to other technologies, e.g., accelerator mass spectroscopy. However, there exists a demand for moving beyond the microgram range, especially from regenerative medicine, where samples consist of, e.g., DNA, and, hence, the total sample amount is extremely small. Making optogalvanic spectroscopy of carbon isotopes applicable to such small samples, requires miniaturization of the key component of the system, namely the plasma source, in which the sample is ionized before analysis. In this paper, a novel design of such a microplasma source based on a stripline split-ring resonator is presented and evaluated in a basic optogalvanic spectrometer. The investigations focus on the capability of the plasma source to measure the optogalvanic signal in general, and the effect of different system and device specific parameters on the amplitude and stability of the optogalvanic signal in particular. Different sources of noise and instabilities are identified, and methods of mitigating these issues are discussed. Finally, the ability of the cell to handle analysis of samples down to the nanogram range is investigated, pinpointing the great prospects of stripline split-ring resonators in optogalvanic spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural Basis of TLR5-Flagellin Recognition and Signaling

Toll-like receptor 5 (TLR5) binding to bacterial flagellin activates signaling through the transcription factor NF-{kappa}B and triggers an innate immune response to the invading pathogen. To elucidate the structural basis and mechanistic implications of TLR5-flagellin recognition, we determined the crystal structure of zebrafish TLR5 (as a variable lymphocyte receptor hybrid protein) in complex with the D1/D2/D3 fragment of Salmonella flagellin, FliC, at 2.47 angstrom resolution. TLR5 interacts primarily with the three helices of the FliC D1 domain using its lateral side. Two TLR5-FliC 1:1 heterodimers assemble into a 2:2 tail-to-tail signaling complex that is stabilized by quaternary contacts of the FliC D1 domain with the convex surface of the opposing TLR5. The proposed signaling mechanism is supported by structure-guided mutagenesis and deletion analyses on CBLB502, a therapeutic protein derived from FliC.

59 BASIC BIOLOGICAL SCIENCES↗

Region-Based Stability Analysis of Resilient Distribution Systems with Hybrid Grid-Forming and Grid-Following Inverters

In this paper, distribution system stability considering mixed grid-forming (GFM) and grid-following (GFL) inverters is discussed. A holistic small-signal model of the distribution feeder accommodating both GFM and GFL inverters is derived. In contrast to conventional point-by-point stability analysis, a region-based stability assessment approach is proposed and implemented to evaluate small-signal system stability with both GFM and GFL controls. Furthermore, to enhance the computational efficiency, an Artificial Intelligence (AI) assisted Kernel Ridge Regression (KRR) approach is developed to obtain the stability region boundary. Therefore, with the derived stability region, the impact of critical parameters on system stability is intuitively shown, and more importantly, the relationship between the maximum penetration level and the corresponding feasible range of the selected control parameters can be quantified. The proposed approach has been validated using MATLAB/Simulink.

grid-following↗

A frequency and amplitude scanned quadrupole mass filter for the analysis of high m/z ions

Quadrupole mass filters (QMFs) are usually not used to analyze high m/z ions, due to the low frequency resonant circuit that is required to drive them. Here we describe a new approach to generating waveforms for QMFs. Instead of scanning the amplitude of a sine wave to measure the m/z spectrum, the frequency of a trapezoidal wave is digitally scanned. A synchronous, narrow-range (<0.2%) amplitude scan overlays the frequency scan to improve the sampling resolution. Because the frequency is the primary quantity that is scanned, there is, in principle, no upper m/z limit. The frequency signal is constructed from a stabilized base clock using a field programmable gate array. This signal drives integrating amplifiers which generate the trapezoidal waves. For a trapezoidal wave the harmonics can be minimized by selecting the appropriate rise and fall times. To achieve a high resolving power, the digital signal has low jitter, and the trapezoidal waveform is generated with high fidelity. The QMF was characterized with cesium iodide clusters. Singly and multiply charged clusters with z up to +5 were observed. A resolving power of ∼1200 (FWHM) was demonstrated over a broad m/z range. Resolution was lost above 20 000 Th, partly because of congestion due to overlapping multiply charged clusters. Ions were observed for m/z values well in excess of 150 000 Th.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact Radar Transceiver with Included Calibration

The Digital Beamforming Synthetic Aperture Radar (DBSAR) is an eight-channel phased array radar system that employs solid-state radar transceivers, a microstrip patch antenna, and a reconfigurable waveform generator and processor unit. The original DBSAR transceiver design utilizes connectorized electronic components that tend to be physically large and heavy. To achieve increased functionality in a smaller volume, PCB (printed circuit board) transceivers were designed to replace the large connectorized transceivers. One of the most challenging problems designing the transceivers in a PCB format was achieving proper performance in the calibration path. For a radar loop-back calibration path, a portion of the transmit signal is coupled out of the antenna feed and fed back into the receiver. This is achieved using passive components for stability and repeatability. Some signal also leaks through the receive path. As these two signal paths are correlated via an unpredictable phase, the leakage through the receive path during transmit must be 30 dB below the calibration path. For DBSAR s design, this requirement called for a 100-dB isolation in the receiver path during transmit. A total of 16 solid-state L-band transceivers on a PCB format were designed. The transceivers include frequency conversion stages, T/R switching, and a calibration path capable of measuring the transmit power-receiver gain product during transmit for pulse-by-pulse calibration or matched filtering. In particular, this calibration path achieves 100-dB isolation between the transmitted signal and the low-noise amplifier through the use of a switching network and a section of physical walls achieving attenuation of radiated leakage. The transceivers were designed in microstrip PCBs with lumped elements and individually packaged components for compactness. Each transceiver was designed on a single PCB with a custom enclosure providing interior walls and compartments to isolate transceiver subsystems from radiated interference. The enclosure also acts as a heat sink for the voltage regulators and power amplifiers inside the system. The PCB transceiver design produces transmit pulses of 2 W with an arbitrary duty cycle. Each transceiver is fed by an external 120-MHz signal transmit and two 1,140-MHz local oscillator signals. The received signal is amplified and down-converted to 120 MHz and is fed to the data processor. The transceiver dimensions are approximately 3.5 11.5 0.6 in. (9 29 1.5 cm). The PCB transceiver design reduces the volume and weight of the DBSAR instrument while maintaining the functionality found in the original design. Both volume and weight are critical for airborne and flight remote sensing instrumentation.

McLinden, Matthew↗

Towards patterned bioelectronics: facilitated immobilization of exoelectrogenic Escherichia coli with heterologous pili

Summary Biosensors detect signals using biological sensing components such as redox enzymes and biological cells. Although cellular versatility can be beneficial for different applications, limited stability and efficiency in signal transduction at electrode surfaces represent a challenge. Recent studies have shown that the Mtr electron conduit from Shewanella oneidensis MR ‐1 can be produced in Escherichia coli to generate an exoelectrogenic model system with well‐characterized genetic tools. However, means to specifically immobilize this organism at solid substrates as electroactive biofilms have not been tested previously. Here, we show that mannose‐binding Fim pili can be produced in exoelectrogenic E. coli and can be used to selectively attach cells to a mannose‐coated material. Importantly, cells expressing fim genes retained current production by the heterologous Mtr electron conduit. Our results demonstrate the versatility of the exoelectrogenic E. coli system and motivate future work that aims to produce patterned biofilms for bioelectronic devices that can respond to various biochemical signals.

59 BASIC BIOLOGICAL SCIENCES↗

The system design of a rubidium maser frequency standard

The Rubidium Maser Frequency Standard is a precision frequency source with excellent short-term stability. A type PBR-II Rb maser frequency standard was developed by the Beijing Institute of Radio Metrology and Measurement (BIRMM). The time-domain frequency stability (two-sample variance) of this frequency standard is less than 1/5 times 10 to the 13th power for t=10ms yields 1.0s, fh=1.0 KHz. Two PBR-II frequency standards were used as reference frequency sources in a frequency stability measurement system. Some important system characteristics for the PBR-II Rb maser frequency standard such as phase noise and frequency stability transfer characteristics are discussed. Furthermore, the design of the frequency standard for optimum frequency stability of the output signal; the choice of a voltage controlled crystal oscillator for the frequency standard; the design of the phase-locked loop; and the frequency stability test results on the PBR-II are discussed.

Xiong, C. X.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

CHARACTERIZATION OF A SPURIOUS ONE-YEAR SIGNAL IN HARPS DATA

The HARPS spectrograph is showing an extreme stability, close to the m s{sup −1} level, over more than 10 years of data. However, the radial velocities of some stars are contaminated by a spurious one-year signal with an amplitude that can be as high as a few m s{sup −1}. This signal is in opposition of phase with the revolution of Earth around the Sun and can be explained by the deformation of spectral lines crossing block stitchings of the CCD when the spectrum of an observed star is alternatively blueshifted and redshifted due to the motion of Earth around the Sun. This annual perturbation can be suppressed by either removing those affected spectral lines from the correlation mask used by the cross-correlation technique to derive precise radial velocities, or by simply fitting a yearly sinusoid to the radial velocity data. This is mandatory if we want to detect long-period low-amplitude signals in the HARPS radial velocities of quiet solar-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Shuttle propellant loading instrumenation development

A continuous capacitance sensor was developed and an analog signal conditioner was evaluated to demonstrate the acceptability of these items for use in the space shuttle propellant loading system. An existing basic sensor concept was redesigned to provide capability for cryogenic operation, to improve performance, and to minimize production costs. Sensor development verification consisted of evaluation of sensor linearity, cryogenic performance, and stability during vibration. The signal conditioner evaluation consisted mainly of establishing the effects of the variations in temperature and cable parameters and evaluating the stability. A sensor linearity of 0.04 in. was achieved over most of the sensor length. The sensor instability caused by vibration was 0.04 percent. The cryogenic performance data show a maximum instability of 0.19 percent at liquid hydrogen temperature; a theoretical calibration can be computed a within 1 percent. The signal conditioner evaluation showed that, with temperature compensation, all error sources typically contribute much less than 1 percent. An estimate of the accuracy achievable with the sensor and signal conditioner shows an rss estimate of 0.75 in. for liquid oxygen and 1.02 in. for liquid hydrogen. These are approximately four times better than the shuttle requirements. Comparison of continuous sensor and discrete sensor performance show the continuous sensor to be significantly better when there is surface activity due to sloshing, boiling, or other disturbances.

Hamlet, J.↗

Neuroligin-3 protects retinal cells from H2O2-induced cell death via activation of Nrf2 signaling

Highlights: • NLGN3 protects retinal pigment epithelium (RPE) cells and retinal ganglion cells (RGCs) from H{sub 2}O{sub 2}. • NLGN3 inhibits H{sub 2}O{sub 2}-induced ROS production, lipid peroxidation and DNA damage in retinal cells. • NLGN3 efficiently activates Nrf2 signaling in human RPE cells and RGCs. • Nrf2 silencing abolishes NLGN3-induced anti-H{sub 2}O{sub 2} actions in human retinal cells. Intensified oxidative stress can cause severe damage to human retinal pigment epithelium (RPE) cells and retinal ganglion cells (RGCs). The potential effect of neuroligin-3 (NLGN3) against the process is studied here. Our results show that NLGN3 efficiently inhibited hydrogen peroxide (H{sub 2}O{sub 2})-induced death and apoptosis in human RPE cells and RGCs. H{sub 2}O{sub 2}-induced reactive oxygen species (ROS) production, lipid peroxidation and DNA damage in retinal cells were alleviated by NLGN3. NLGN3 activated nuclear-factor-E2-related factor 2 (Nrf2) signaling, enabling Nrf2 protein stabilization, nuclear translocation and expression of key anti-oxidant enzymes (HO1, NOQ1 and GCLC) in RPE cells and RGCs. Further results demonstrate that NLGN3 activated Akt-mTORC1 signaling in retinal cells. Conversely, Akt-mTORC1 inhibitors (RAD001 and LY294002) reduced NLGN3-induced HO1, NOQ1 and GCLC mRNA expression. Significantly, Nrf2 silencing by targeted shRNAs reversed NLGN3-induced retinal cytoprotection against H{sub 2}O{sub 2}. We conclude that NLGN3 activates Nrf2 signaling to protect human retinal cells from H{sub 2}O{sub 2}. NLGN3 could be further tested as a valuable retinal protection agent.

60 APPLIED LIFE SCIENCES↗

Optimization of system parameters for a complete multispectral polarimeter

We optimize a general class of complete multispectral polarimeters with respect to signal-to-noise ratio, stability against alignment errors, and the minimization of errors regarding a given set of polarization states. The class of polarimeters that are dealt with consists of at least four polarization optics each with a multispectral detector. A polarization optic is made of an azimuthal oriented wave plate and a polarizing filter. A general, but not unique, analytic solution that minimizes signal-to-noise ratio is introduced for a polarimeter that incorporates four simultaneous measurements with four independent optics. The optics consist of four sufficient wave plates, where at least one is a quarter-wave plate. The solution is stable with respect to the retardance of the quarter-wave plate; therefore, it can be applied to real-world cases where the retardance deviates from {lambda}/4. The solution is a set of seven rotational parameters that depends on the given retardances of the wave plates. It can be applied to a broad range of real world cases. A numerical method for the optimization of arbitrary polarimeters of the type discussed is also presented and applied for two cases. First, the class of polarimeters that were analytically dealt with are further optimized with respect to stability and error performance with respect to linear polarized states. Then a multispectral case for a polarimeter that consists of four optics with real achromatic wave plates is presented. This case was used as the theoretical background for the development of the Airborne Multi-Spectral Sunphoto- and Polarimeter (AMSSP), which is an instrument for the German research aircraft HALO.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-526: On the Linearity, Stability and Beam Energy Dependence of CdSe Quantum Dots as Scintillating Probes

Purpose: Structure and energy transfer mechanisms confer colloidal quantum dots (cQDs) interesting properties, among them their potential as scintillators. CdSe multi-shell cQDs in powder were investigated under photons irradiation. The purpose of this work is to characterize signal to dose linearity, stability with time and to quantify the dependence of their light output with beam energy. Methods: The cQDs are placed at the extremity of a non-scintillating plastic collecting fiber, with the other extremity connected to an Apogee U2000C CCD camera. The CCD camera collects the fluorescence light from irradiated cQDs from which the delivered dose is extracted. This signal is corrected for Cerenkov contamination at MV energies using the chromatic technique. The detector was irradiated with two devices: Xstrahl 200 orthovoltage unit for 120, 180 and 220 kVp and a Varian Clinac iX for 6 and 23 MV. Results: Linear output response with varying dose is observed for all beam energies with R2 factors > 0,999. Reproducibility measurements were performed at 120 kVp: the same set-up was irradiated at different time intervals (one week and three months). The results showed only a small relative decrease of light output of 3,2 % after a combine deposited dose of approximately 95 Gy. CdSe nanocrystals response has been studied as a function of beam energy. The output increases with decreasing energy from 120 kVp to 6 MV and increase again for 23 MV. This behavior could be explained in part by the cQDs high-Z composition. Conclusion: The fluorescence light output of CdSe cQDs was found to be linear as a function of dose. The results suggest stability of the scintillation output of cQDs over time. The specific composition of cQDs is the main cause of the observed energy dependence. We will further look into particle beam dependence of the cQDs. Bourse d'excellence aux etudes graduees du CRC (Centre de Recherche sur le Cancer, Universite Laval) Bourse d'excellence aux etudes graduees du CRC (Centre de Recherche sur le Cancer, Universite Laval)

60 APPLIED LIFE SCIENCES↗