Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Noninvasive Indicators of Intracranial Pressure Before, During, and After Long-Duration Spaceflight

Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, while lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied thirteen crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ~45 and ~150 days of spaceflight with and without 25 mmHg LBNP. We used 4 techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture (CCFP: mean difference -98.5 -nl [CI: -190.8 to -6.1 -nl], p = 0.037]; OAE: -19.7 degrees [CI: -10.4 to -29.1 degrees], p < 0.001), but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures (14.3 mmHg [CI: 10.1 to 18.5mmHg], p < 0.001), but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.

Jessica V. Jasien↗

Study of Advanced Occupant Models to Quantify Injury Risk for eVTOL Vehicles

Urban transportation is currently evolving from traditional ground-based vehicles (cars, taxis, and buses) to include air-based electric vertical take-off and landing (eVTOL) vehicles which can be utilized for on-demand transportation, cargo transport, and emergency services. These new eVTOL vehicles are designed to be small, lightweight, and able to operate autonomously without user intervention. Safety is a big part of eventual eVTOL adoption, however gaps in the consideration of safety features exist. Anthropomorphic test devices (ATDs) are used in aerospace crashworthiness standards to quantify occupant injury risk and develop improved safety designs for emergency landing situations, but the ATDs currently used in aircraft certification requirements were developed many decades ago. Developments have occurred over the years involving ATD technology, which includes a host of newer and more biofidelic ATDs such as the Test Device for Human Occupant Restraint (THOR). Increased computing power has also allowed for detailed computational human body models (HBMs) to be created, such as the Global Human Body Model Consortium (GHBMC). This study aims to assess the capability of both HBMs and new ATD designs to identify injury mechanisms within eVTOL relevant emergency landing conditions. Finite element (FE) analysis was used to expand upon full-scale and seat level impact testing conducted by researchers at the National Aeronautics and Space Administration (NASA) to look at effects of occupant model configurations on prediction of injury. The GHBMC HBM and THOR ATD models were simulated in the seat level test conditions to characterize differences between these advanced assessment tools and traditional ATDs in the isolated seat loading environment. Results identified key differences in the responses from each of the models utilized and compared their impact response in head, neck, and spinal injury metrics. The THOR model identified potential risks for head injuries due to head impacts on the seat, however it predicted lower spinal loads than the other occupant surrogates. The GHBMC showed distinctly different biomechanical responses compared to the ATD. The GHBMC model is much more deformable than the ATDs and it exhibited higher distribution of forces and increased sensitivity to the duration of acceleration pulses. Both models incorporated into this study identified key mechanisms for injury that should be considered for passenger safety in the development of these novel aircraft. In addition, this study demonstrated the value of FE modeling for running a variety of complex human surrogates to identify potential injury mechanisms for consideration in regulation and development of new aircraft. Continued research in this field to improve validation these models will only lead to safer aircraft and more comprehensive safety measures.

Crashworthiness↗

Study of Advanced Occupant Models to Quantify Injury Risk for eVTOL Vehicles

Urban transportation is currently evolving from traditional ground-based vehicles (cars, taxis, and buses) to include air-based electric vertical take-off and landing (eVTOL) vehicles which can be utilized for on-demand transportation, cargo transport, and emergency services. These new eVTOL vehicles are designed to be small, lightweight, and able to operate autonomously without user intervention. Safety is a big part of eventual eVTOL adoption, however gaps in the consideration of safety features exist. Anthropomorphic test devices (ATDs) are used in aerospace crashworthiness standards to quantify occupant injury risk and develop improved safety designs for emergency landing situations, but the ATDs currently used in aircraft certification requirements were developed many decades ago. Developments have occurred over the years involving ATD technology, which includes a host of newer and more biofidelic ATDs such as the Test Device for Human Occupant Restraint (THOR). Increased computing power has also allowed for detailed computational human body models (HBMs) to be created, such as the Global Human Body Model Consortium (GHBMC). This study aims to assess the capability of both HBMs and new ATD designs to identify injury mechanisms within eVTOL relevant emergency landing conditions. Finite element (FE) analysis was used to expand upon full-scale and seat level impact testing conducted by researchers at the National Aeronautics and Space Administration (NASA) to look at effects of occupant model configurations on prediction of injury. The GHBMC HBM and THOR ATD models were simulated in the seat level test conditions to characterize differences between these advanced assessment tools and traditional ATDs in the isolated seat loading environment. Results identified key differences in the responses from each of the models utilized and compared their impact response in head, neck, and spinal injury metrics. The THOR model identified potential risks for head injuries due to head impacts on the seat, however it predicted lower spinal loads than the other occupant surrogates. The GHBMC showed distinctly different biomechanical responses compared to the ATD. The GHBMC model is much more deformable than the ATDs and it exhibited higher distribution of forces and increased sensitivity to the duration of acceleration pulses. Both models incorporated into this study identified key mechanisms for injury that should be considered for passenger safety in the development of these novel aircraft. In addition, this study demonstrated the value of FE modeling for running a variety of complex human surrogates to identify potential injury mechanisms for consideration in regulation and development of new aircraft. Continued research in this field to improve validation these models will only lead to safer aircraft and more comprehensive safety measures.

Crashworthiness↗

Photovoltaic module with removable wind deflector

A photovoltaic (PV) module assembly including a PV module, a deflector, and a clip. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes a support arm forming a seat. The deflector defines a front face and a rear face, with the clip extending from either the trailing frame member or the rear face of the deflector. In a mounted state, the deflector is nested within the seat and is releasably mounted to the trailing frame member via the clip. In some embodiments, the support arm forms a second seat, with the PV module assembly providing a second mounted state in which the deflector is in a differing orientation/slope, nested within the second seat and releasably mounted to the trailing frame member via the clip.

14 SOLAR ENERGY↗

Photovoltaic module with removable wind deflector

A photovoltaic (PV) module assembly including a PV module, a deflector, and a clip. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes a support arm forming a seat. The deflector defines a front face and a rear face, with the clip extending from either the trailing frame member or the rear face of the deflector. In a mounted state, the deflector is nested within the seat and is releasably mounted to the trailing frame member via the clip. In some embodiments, the support arm forms a second seat, with the PV module assembly providing a second mounted state in which the deflector is in a differing orientation/slope, nested within the second seat and releasably mounted to the trailing frame member via the clip.

25 ENERGY STORAGE↗

Photovoltaic module with removable wind deflector

A photovoltaic (PV) module assembly including a PV module, a deflector, and a clip. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes a support arm forming a seat. The deflector defines a front face and a rear face, with the clip extending from either the trailing frame member or the rear face of the deflector. In a mounted state, the deflector is nested within the seat and is releasably mounted to the trailing frame member via the clip. In some embodiments, the support arm forms a second seat, with the PV module assembly providing a second mounted state in which the deflector is in a differing orientation/slope, nested within the second seat and releasably mounted to the trailing frame member via the clip.

14 SOLAR ENERGY↗

Method, apparatus and system for controlling fluid flow

A system, apparatus and method of controlling the flow of a fluid are provided. In accordance with one embodiment of the present invention, a flow control device includes a valve having a flow path defined therethrough and a valve seat in communication with the flow path with a valve stem disposed in the valve seat. The valve stem and valve seat are cooperatively configured to cause mutual relative linear displacement thereof in response to rotation of the valve stem. A gear member is coupled with the rotary stem and a linear positioning member includes a portion which complementarily engages the gear member. Upon displacement of the linear positioning member along a first axis, the gear member and rotary valve stem are rotated about a second axis and the valve stem and valve seat are mutually linearly displaced to alter the flow of fluid through the valve.

42 ENGINEERING↗

Peri-prosthetic fracture vibration testing

The purpose of this study is to establish a test setup and vibration analysis method to predict femoral stem seating and prevent bone fracture using accelerometer or force response data from an instrument stem and impactor. This study builds upon earlier studies to identify a means to supplement a surgeon's tactile and auditory senses by using damage identification techniques normally used for civil and mechanical structures. Testing will be conducted using foam cortical shell sawbones prepared for stems of different geometries. Each stem will be instrumented with an accelerometer. Two impactor designs will be compared: a monolithic impactor with an integrated load cell and accelerometer and a two piece impactor. Acceleration and force measurements will be taken in the direction of impaction. Signal processing techniques will be applied to the acceleration time histories to determine features that can be used to assess device seating and potential fracture. A consistent energy input will be applied using a drop tower. The effect of introducing compliance under the bone support vise will also be investigated. The ultimate goal of this study is to design an integrated portable data acquisition system capable of being used in future cadaveric testing. This paper will discuss the experimental set-up, the signal processing techniques used and the subsequent results.

42 ENGINEERING↗

SU-C-19A-05: Treatment Chairs for Modern Radiation Therapy Treatments

Purpose: Treating patients in a seated position has potential advantages including improved comfort, increased lung volume, and reduced respiratory motion. We compared chair designs for head and neck, thoracic and breast patients for use with either IGRT linacs or a proposed low-cost fixed horizontal beam-line machine. Methods: Three treatment chairs were designed and constructed. Two of the chairs are based on a massage-chair, with the patient angled slightly forwards and knee rests used to minimize intra-fraction slouch. The third chair design is more conventional; the patient is angled backwards, with indexed positioning devices and the ability to attach thermoplastic masks. Patient geometries, including PTV location and patient sizes, were extracted from 137 CTs of past patients were used to model the probability of collision between the patient and the linac for various seated positions. All chairs were designed around the weight limits for couches on our linacs. At the time of writing we have just received IRB approval for imaging studies to evaluate comfort, and intra- and interfraction reproducibility. Results: The geometric analysis showed that head and neck patients and thoracic patients could be treated without collision. However, there is very limited space between the patient and the treatment/imaging devices, so careful design of the chair is essential. The position of the treatment target and extended arm positioning means that this is a particular concern for thoracic and breast patients. This was demonstrated for one of the prototype chairs designed for breast treatment where the arm holders would collide with the kV detector. The extra clearance of a dedicated fixed-beam linac would overcome these difficulties. Intra- and inter-fraction reproducibility results will be presented at the meeting. Conclusion: To take advantage of the clinical advantages of seated treatments, appropriate treatment chairs are needed. A dedicate fixed-beam linac may enable more options. This work was partially funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Neck Muscle Coactivation Response to Varied Levels of Mental Workload During Simulated Flight Tasks

Objective To evaluate neck muscle coactivation across different levels of mental workload during simulated flight tasks. Background Neck pain (NP) is highly prevalent among military aviators. Given the complex nature within the flight environment, mental workload may be a risk factor for NP. This may induce higher levels of neck muscle coactivity, which over time may accelerate fatigue, increase neck discomfort, and affect flight task performance. Method Three counterbalanced mental workload conditions represented by simulated flight tasks modulated by interstimulus frequency and complexity were investigated using the Modifiable Multitasking Environment (ModME). The primary measure was a neck coactivation index to describe the neuromuscular effort of the neck muscles as a system. Additional measures included perceived workload (NASA TLX), subjective discomfort, and task performance. Participants ( n = 60; 30M, 30F) performed three test conditions over 1 hr each while seated in a simulated seating environment. Results Neck coactivation indices (CoA) and subjective neck discomfort corresponded with increasing level of mental workload. Average CoAs for low, medium, and high workloads were: .0278(SD = .0232), .0286(SD = .0231), and .0295(SD = .0228), respectively. NASA TLX mental, temporal, effort, and overall scores also increased with the level of mental workload assigned. For ModME task performance, the overall performance score, monitoring accuracy, and resource management accuracy decreased while reaction times increased with the increasing level of mental workload. Communication accuracy was lowest with the low mental workload but had higher reaction times relative to increasing workload. Conclusion Mental workload affects neck muscle coactivation during combinations of simulated flight tasks within a simulated helicopter seating environment. Application The results of this study provide insights into the physical response to mental workload. With increasing multisensory modalities within the work environment, these insights may assist the consideration of physical effects from cognitive factors.

Behavioral Sciences↗

NEXT GENERATION SOLVENT MATERIALS COMPATIBILITY WITH POLYMER COMPONENTS WITHIN MODULAR CAUSTIC-SIDE SOLVENT EXTRACTION UNIT

The Office of Waste Processing, within the Office of Technology Innovation and Development, is funding the development of an enhanced solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. The technical effort is collaboration between Oak Ridge National Laboratory (ORNL), Savannah River National Laboratory (SRNL), and Argonne National Laboratory. The first deployment target for the technology is within the Modular Caustic-Side Solvent Extraction Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the chemical components are compatible with the installed equipment. In the instance of a new organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the facility. This report provides the data from exposing these polymers to the Next Generation Solvent (NGS). The test was conducted over six months. An assessment of the dimensional stability of polymers present in MCU (i.e., PEEK, Grafoil{reg_sign}, Tefzel{reg_sign} and Isolast{reg_sign}) in the modified NGS (where the concentration of the guanidine suppressor and MaxCalix was varied systematically) showed that guanidine (LIX{reg_sign}79) selectively affected Tefzel{reg_sign} (by an increase in size and lowering its density). The copolymer structure of Tefzel{reg_sign} and possibly its porosity allows for the easier diffusion of guanidine. Tefzel{reg_sign} is used as the seat material in some of the valves at MCU. Long term exposure to guanidine, may make the valves hard to operate over time due to the seat material (Tefzel{reg_sign}) increasing in size. However, since the physical changes of Tefzel{reg_sign} in the improved solvent are comparable to the changes in the CSSX baseline solvent, no design changes are needed with respect to the Tefzel{reg_sign} seating material. PEEK, Grafoil{reg_sign} and Isolast{reg_sign} were not affected by guanidine and MaxCalix within six months of exposure. The initial rapid weight gain observed in every polymer is assigned to the finite and limited uptake of Isopar{reg_sign} L/Modifier by the polymers probably due to the polymers porosity and rough surfaces. Spectroscopic data on the organic liquid and the polymer surfaces showed no preferential adsorption of any component in the NGS to the polymers and no leachate was observed in the NGS from any of the polymers studied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Solvent – Materials Compatibility with Polymer Components within Modular CausticSide Solvent Extraction Unit (Final Report)

The Office of Waste Processing, within the Office of Technology Innovation and Development, is funding the development of an enhanced solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. The technical effort is collaboration between Oak Ridge National Laboratory (ORNL), Savannah River National Laboratory (SRNL), and Argonne National Laboratory. The first deployment target for the technology is within the Modular Caustic-Side Solvent Extraction Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the chemical components are compatible with the installed equipment. In the instance of a new organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the facility. This report provides the data from exposing these polymers to the Next Generation Solvent (NGS). The test was conducted over six months. An assessment of the dimensional stability of polymers present in MCU (i.e., PEEK, Grafoil, Tefzel and Isolast) in the modified NGS (where the concentration of LIX®79 and MaxCalix was varied systematically) showed that LIX®79 selectively affected Tefzel and its different grades (by an increase in size and lowering its density). The copolymer structure of Tefzel and possibly its porosity allows for the easier diffusion of LIX®79. Tefzel is used as the seat material in some of the valves at MCU. Long term exposure to LIX®79, may make the valves hard to operate over time due to the seat material (Tefzel) increasing in size. However, since the physical changes of Tefzel in the improved solvent are comparable to the changes in the CSSX baseline solvent, no design changes are needed with respect to the Tefzel seating material. PEEK, Grafoil and Isolast were not affected by LIX®79 and MaxCalix within six months of exposure. The initial rapid weight gain observed in every polymer is assigned to the finite and limited uptake of Isopar® L/Modifier by the polymers probably due to the polymers porosity and rough surfaces. Spectroscopic data on the organic liquid and the polymer surfaces showed no preferential adsorption of any component in the NGS to the polymers and with the exception of CPVC, no leachate was observed in the NGS from any of the polymers studied. The testing shows no major concerns for compatibility over the short duration of these tests but does indicate that longer duration exposure studies are warranted, especially for Tefzel. However, the physical changes experienced by Tefzel in the improved solvent were comparable to the physical changes obtained when Tefzel is placed in CSSX baseline solvent. Therefore, there is no effect of the improved solvent beyond those observed in CSSX baseline solvent.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fleet-Level Fuel Impact of Hybrid-Electric Aircraft in United States

Here, this paper examines the impact of two potential solutions for increasing fuel efficiency and reducing emissions in commercial aviation: hybrid-electric propulsion and the use of drop-in synthetic aviation fuels (SAFs). The authors modeled three representative aircraft employed in the U.S. domestic market: a 70-seat regional turboprop, a 100-seat airliner, and a 180-seat airliner. These aircraft were retrofitted with hybrid-electric propulsion systems that integrate batteries and electric motors to provide additional torque to the propeller or fan. The authors explored various technological scenarios involving different battery specific energies, electric motor specific powers, and other relevant parameters. Flight performance models were used to analyze the range–payload capabilities of these new hybrid-electric aircraft and to compare them with their conventional counterparts. Subsequently, the authors virtually deployed the hybrid-electric aircraft on 2019 U.S. domestic commercial flights to assess the types and lengths of flights that could be serviced by this new fleet. We then compared the resulting fuel consumption, energy use, and emissions with those of a conventional fleet using a combination of jet fuel and SAF.

SAF↗

Improved poppet valve provides positive damageproof seal

Soft-seat poppet valve provides positive closure against fluid without damage to the seating surface on repeated cycling. It incorporates two compressible soft rings and a retaining ring of hard metal. Sealing is effected when the poppet seat is forced into intimate contact with a mating surface on one of the soft rings.

Wallace, E. D.↗

Bipropellant shut-off valve

An advanced design of an all metal, fast response, bipropellant, shut-off valve for use on long duration space missions is reported. The valve provides the flow control capability for a 1,000 lb thrust, bipropellant engine using oxygen difluoride and diborane as propellants. The shutoff seal selection is a soft-on-hard metal concept. The soft seal is a spherical shell that seats against a hard conical seat. Beryllium copper and beryllium nickel seals were selected to seal against an electrolyzed Inconel 718 seat. Poppet shaft sealing is achieved by use of hydroformed, Inconel 718 bellows. Two valve assemblies were fabricated and subjected to a series of tests including leak, response time, flow capacity, dry cycles, water cycles, liquid nitrogen cycles, liquid fluorine cycles, and lead-lag operation cycles. These tests demonstrated the ability of the valve to meet design goals.

Smith, J. V.↗

Tilting table for ergometer and for other biomedical devices

The apparatus is for testing the human body in a variety of positions, ranging from the vertical to the supine, while exercising on an ergometer; and can also be used for angular positioning of other biomedical devices. It includes a floor plate and a hinged plate upon which to fix the ergometer, a back rest and a head rest attached at right angles to said hinged plate and behind the seat of the ergometer, dual hydraulic cylinders for raising and lowering the hinged plate through 90 deg by means of a self contained hydraulic system, with valve means for control and positive stops on the apparatus to prevent over travel. Tests can be made with the subject positioned on the seat of the ergometer, through the various angles, with a substantially normal body attitude relative to the seat and ergometer.

Gause, R. L.↗

Flow control valve

A flow control valve for high temperature fluids is disclosed. The valve is characterized by an all-metal flow control unit including a tubular conduit, terminating in a valve seat, a throttling cone having an internal, truncated conical surface coaxially related to the valve seat and supported for axial motion relative to the seat, and an axially reciprocable, flow-control plug supported in coaxial relation with the cone. The plug is provided with a truncated conical surface configured to be mated with the surface of the throttling cone for regulating a flow of fluid established through the unit and a curved shut-off surface.

Hays, L. G.↗

Ultrasonically bonded value assembly

A valve apparatus capable of maintaining a fluid-tight seal over a relatively long period of time by releasably bonding a valve member to its seat is described. The valve member is bonded or welded to the seat and then released by the application of the same energy to the bond joint. The valve member is held in place during the bonding by a clamping device. An appropriate force device can activate the opening and closing of the valve member. Various combinations of material for the valve member and valve seat can be utilized to provide an adequate sealing bond. Aluminum oxide, stainless steel, inconel, tungsten carbide as hard materials and copper, aluminum, titanium, silver, and gold as soft materials are suggested.

Salvinski, R. J.↗