A new mass spectrometer system for investigating laser-induced vaporization phenomena

A laser has been combined with a mass spectrometer in a new configuration developed for studies of high-temperature materials. A vacuum-lock, solid-sample inlet is mounted at one end of a cylindrical, high-vacuum chamber one meter in length with a nude ion-source, time-of-flight mass spectrometer at the opposite end. The samples are positioned along the axis of the chamber at distances up to one meter from the ion source, and their surfaces are vaporized by a pulsed laser beam entering via windows on one side of the chamber. The instrumentation along with its capabilities is described, and results from laser-induced vaporization of several graphites are presented.

Lincoln, K. A.↗

Comparative studies of grain size separates of 60009

Five samples from 60009, the lower half of a double drive tube, were analyzed via grain-size methods, with particle types classified and counted in the coarser grain sizes. Studies were undertaken of particle types and distributions by petrographic methods, of magnetic fractions, of the size splits and magnetic splits as analyzed by ferromagnetic resonance (FMR) techniques, of maturity (based on agglutinate content, FMR index Is/FeO, mean size of sub-cm material, magnetic fraction), of possible reworking or mixing in situ, and of depositional history. Maturity indices are in substantial agreement for all of the five samples. Strong positive correlation of percent agglutinates and percent bedrock-derived lithic fragments, combined with negative correlation of those components with percent single crystal plagioclase, argue against in situ reworking of the same soil.

Mckay, D. S.↗

The HEAO-1 soft X-ray survey of cataclysmic variable stars

A survey of the soft X-ray emission from 206 cataclysmic variable stars, including dwarf novae in optically quiescent states, classical novae, recurrent novae, nova-like objects and polars, is reported. This is an extension of a previous survey of dwarf novae in outbursts by Cordova et al. (1980). The number of surveyed stars that correspond to features greater than 2 sigma is not in excess of the number of chance coincidences expected on the basis of a random sample of positions distributed over the entire sky. While a few cataclysmic variables have been previously identified as X-ray sources, the results of this survey imply that cataclysmic variables as a class must be, at best, low-luminosity X-ray sources with fluxes below the HEAO-1 A2 detector's sensitivity limit of a few times 10 to the -11th erg/sq cm-s in the energy range 0.1-3 keV. The X-ray luminosities of the cataclysmic variables are consistent with predictions from disk accretion models, provided that a wide range of accretion rates apply.

Cordova, F. A.↗

Contactless Measurement of Physical Properties

Surface tension and other properties determined from measurement of resonant frequency. Surface tension and other physical properties of molten and liquid samples excited at resonance measured by observing photographic or TV image and noting resonant frequency and rate of change. Technique used in normal gravity and low gravity in either vacuum or gaseous environment, where sample is positioned by electrostatic, acoustic, or magnetic forces.

Elleman, D. D.↗

Acoustic Levitation System

Dense materials, such as steel balls, continuously levitated with energy provided by efficient high-powered siren in combination with shaped reflector. Reflector system, consisting of curved top reflector and flat lower reflector, eliminates instability in spatial positioning of sample.

Gammell, P. M.↗

Cosmic ray exposure ages of iron meteorites, complex irradiation and the constancy of cosmic ray flux in the past

While previous calculations of potassium ages assumed a constant cosmic ray flux and a single stage (no change in size) exposure of iron meteorites, present calculations relaxed these constancy assumptions and the results reveal multistage irradiations for some 25% of the meteorites studied, implying multiple breakup in space. The distribution of exposure ages suggests several major collisions (based on chemical composition and structure), although the calibration of age scales is not yet complete. It is concluded that shielding-corrected (corrections which depend on size and position of sample) production rates are consistent for the age bracket of 300 to 900 years. These production rates differ in a systematic way from those calculated for present day fluxes of cosmic rays (such as obtained for the last few million years).

Marti, K.↗

Acoustic radiation potential on a sphere in plane, cylindrical, and spherical standing wave fields

The method of Gor'kov is applied for deriving the acoustic radiation potential on a sphere in an arbitrary sound field. Generalized potential and force expressions are derived for arbitrary standing wave modes in rectangular, cylindrical, and spherical geometries for the case where the sphere radius is much smaller than the wavelength. Criteria for determining radiation-potential minima are derived and examples of characteristic spatial radiation-potential profiles are presented. Single modes that can sustain stable positioning are discussed for each geometry. The localizing force strengths for representative standing wave modes in the three geometries are also compared. The positioning of samples due to acoustic forces only are considered. However, the method developed is general and is extended to include gravity or other external forces.

Barmatz, M.↗

Prepreg cure monitoring using diffuse reflectance-FTIR

An in situ diffuse reflectance-Fourier transform infrared technique was developed to determine infrared spectra of graphite fiber prepregs as they were being cured. A bismaleimide, an epoxy, and addition polyimide matrix resin prepregs were studied. An experimental polyimide adhesive was also examined. Samples were positioned on a small heater at the focal point of diffuse reflectance optics and programmed at 15 F/min while FTIR spectra were being scanned, averaged, and stored. An analysis of the resulting spectra provided basic insights into changes in matrix resin molecular structure which accompanied reactions such as imidization and crosslinking. An endo-exothermal isomerization involving reactive end-caps was confirmed for the addition polyimide prepregs. The results of this study contribute to a fundamental understanding of the processing of composites and adhesives. Such understanding will promote the development of more efficient cure cycles.

Young, P. R.↗

Highly automated transmission-edge mapping

Instrumentation and software are described, which are used to determine maps of properties of materials based on optical transmission spectra. In addition to a Fourier transform spectrometer, the hardware includes an xy-stage containing a small stationary aperture and two computer controlled stepper motors for positioning the sample. This idea has been used for years but this implementation is highly automated compared to those previously described. All mapping has been in the 2-15 micron wavelength range but this is not an inherent limitation of the technique. In this spectral range, useful results may be obtained with apertures as small as 25 microns in diameter. The software is described including the algorithm for obtaining the cut-on wavelength from a semiconductor spectrum. Data from both transverse slices and longitudinal slabs of narrow bandgap alloy semiconductors are shown including composition maps for materials solidified with convex and concave growth interfaces.

Szofran, F. R.↗

Inferring vegetation characteristics using a knowledge-based system

A knowledge-based system for inferring physical and biological surface properties of vegetation using nadir and/or directional reflectance data as input is developed. A portion of this system has been developed to discriminate between user-defined vegetation classes using spectral and directional reflectance relationships. This discrimination program was used to classify targets into user-defined ground cover and plant height classes. The program learns class descriptors from samples (both positive and negative) of spectral, directional reflectance data of natural surfaces (bare soils, natural vegetation, and agricultural vegetation). The system is designed to handle any combination of directional view angles. The explicit relationships used in the class descriptions include greater-than relationships between combinations of two view angles and maximum and minimum value relationships. The class descriptions are used to classify an unknown target using the same directional views. The program was tested by learning class descriptions of various categories of percent ground cover and vegetation height.

Kimes, D. S.↗

Diamond film deposition using microwave plasmas under low pressures

Microwave plasma depositions of diamond films have been investigated under low pressures of 10 mTorr to 10 Torr, at low substrate temperatures of 400 to 750 C, using high methane concentrations of 5 to 15 percent and oxygen concentrations of 5 to 10 percent in hydrogen plasmas. The deposition system consists of a microwave plasma chamber, a downstream deposition chamber, and a RF induction-heated sample stage. The deposition system can be operated in either high-pressure microwave or electron cyclotron resonance (ECR) modes by varying the sample stage position. Cathodoluminescence (CL) studies on diamond films deposited at 10 Torr pressure show that CL emissions at 430, 480, 510, 530, 560, 570 and 740 nm can be employed to characterize the quality of diamond films. High-quality, well-faceted diamond films have been deposited at 10 Torr and 600 C using 5 percent CH4 and 5 percent O2 in H2 plasmas; CL measurements on these films show very low N impurities and no detectable Si impurities. Diamond nucleation on SiC has been demonstrated by depositing well-faceted diamond crystallites on SiC-coated Si substrates.

Shing, Y. H.↗

Double-Knudsen-Cell Apparatus Measures Alloy-Component Activities

Double-Knudsen-cell apparatus provides molecular beam from selected one of two Knudsen cells. Both cells maintained at same temperature. Molecular beam directed into mass spectrometer for measurement of vapor pressure of selected material component. Designed to minimize undesired thermal gradients, provides appropriate translation to place selected cell in position for sampling, and minimizes mixing of molecular beams from cells.

Jacobson, Nathan S.↗

Steady-State Pursuit Is Driven by Object Motion Rather Than the Vector Average of Local Motions

We have previously shown that humans can pursue the motion of objects whose trajectories can be recovered only by spatio-temporal integration of local motion signals. We now explore the integration rule used to derive the target-motion signal driving pursuit. We measured the pursuit response of 4 observers (2 naive) to the motion of a line-figure diamond viewed through two vertical bar apertures (0.2 cd/square m). The comers were always occluded so that only four line segments (93 cd/square m) were visible behind the occluding foreground (38 cd/square m). The diamond was flattened (40 & 140 degree vertex angles) such that vector averaging of the local normal motions and vertical integration (e.g. IOC) yield very I or different predictions, analogous to using a Type II plaid. The diamond moved along Lissajous-figure trajectories (Ax = Ay = 2 degrees; TFx = 0.8 Hz; TFy = 0.4 Hz). We presented only 1.25 cycles and used 6 different randomly interleaved initial relative phases to minimize the role of predictive strategies. Observers were instructed to track the diamond and reported that its motion was always coherent (unlike type II plaids). Saccade-free portions of the horizontal and vertical eye-position traces sampled at 240 Hz were fit by separate sinusoids. Pursuit gain with respect to the diamond averaged 0.7 across subjects and directions. The ratio of the mean vertical to horizontal amplitude of the pursuit response was 1.7 +/- 0.7 averaged across subjects (1SD). This is close to the prediction of 1.0 from vertical motion-integration rules, but far from 7.7 predicted by vector averaging and infinity predicted by segment- or terminator-tracking strategies. Because there is no retinal motion which directly corresponds to the diamond's motion, steady-state pursuit of our "virtual" diamond is not closed-loop in the traditional sense. Thus, accurate pursuit is unlikely to result simply from local retinal negative feedback. We conclude that the signal driving steady-state pursuit is not the vector average of local motion signals, but rather a more vertical estimate of object motion, derived in extrastriate cortical areas beyond V1, perhaps NIT or MST.

Stone, Leland S.↗

Detection of polyomavirus simian virus 40 tumor antigen DNA in AIDS-related systemic non-Hodgkin lymphoma

Systemic non-Hodgkin lymphoma (S-NHL) is a common malignancy during HIV infection, and it is hypothesized that infectious agents may be involved in the etiology. Epstein-Barr virus DNA is found in <40% of patients with AIDS-related S-NHL, suggesting that other oncogenic viruses, such as polyomaviruses, may play a role in pathogenesis. We analyzed AIDS-related S-NHL samples, NHL samples from HIV-negative patients, peripheral blood leukocytes from HIV-infected and -uninfected patients without NHL, and lymph nodes without tumors from HIV-infected patients. Specimens were examined by polymerase chain reaction analysis with use of primers specific for an N-terminal region of the oncoprotein large tumor antigen ( T-ag ) gene conserved among all three polyomaviruses (simian virus 40 [SV40], JC virus, and BK virus). Polyomavirus T-ag DNA sequences, proven to be SV40-specific, were detected more frequently in AIDS-related S-NHL samples (6 of 26) than in peripheral blood leukocytes from HIV-infected patients (6 of 26 vs. 0 of 69; p =.0001), NHL samples from HIV-negative patients (6 of 26 vs. 0 of 10; p =.09), or lymph nodes (6 of 26 vs. 0 of 7; p =.16). Sequences of C-terminal T-ag DNA from SV40 were amplified from two AIDS-related S-NHL samples. Epstein-Barr virus DNA sequences were detected in 38% (10 of 26) AIDS-related S-NHL samples, 50% (5 of 10) HIV-negative S-NHL samples, and 57% (4 of 7) lymph nodes. None of the S-NHL samples were positive for both Epstein-Barr virus DNA and SV40 DNA. Further studies of the possible role of SV40 in the pathogenesis of S-NHL are warranted.

NASA Discipline Regulatory Physiology↗

Effect of scanline orientation on ventricular flow propagation: assessment using high frame-rate color Doppler echocardiography

Color M-mode echocardiography has recently been utilized to describe diastolic flow propagation velocity (Vp) in the left ventricle. While increasing temporal resolution from 15 to 200 Hz, this M-mode technique requires the user to select a single scanline, potentially limiting quantification of Vp due to the complex three-dimensional inflow pattern. We previously performed computational fluid dynamics simulations to demonstrate the insignificance of the scanline orientation, however geometric complexity was limited. The purpose of this study was to utilize high frame-rate 2D color Doppler images to investigate the importance of scanline selection in patients for the quantification of Vp. 2D color Doppler images were digitally acquired at 50 frames/s in 6 subjects from the apical 4-chamber window (System 5, GE/Vingmed, Milwaukee, WI). Vp was determined for a set of scanlines positioned through 5 locations across the mitral annulus (from the anterior to posterior mitral annulus). An analysis of variance was performed to examine the differences in Vp as a function of scanline position. Vp was not effected by scanline position in sampled locations from the center of the mitral valve towards the posterior annulus. Although not statistically significant, there was a trend to slower propagation velocities on the anterior side of the valve (60.8 +/- 16.7 vs. 54.4 +/- 13.6 cm/s). This study clinically validates our previous numerical experiment showing that Vp is insensitive to small perturbations of the scanline through the mitral valve. However, further investigation is necessary to examine the impact of ventricular geometry in pathologies including dilated cardiomyopathy.

Non-NASA Center↗

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis (PUMA) is an instrument that measures several quantities indicative of human metabolic function. Specifically, this instrument makes time-resolved measurements of temperature, pressure, flow, and the partial pressures of oxygen and carbon dioxide in breath during both inhalation and exhalation. Portable instruments for measuring these quantities have been commercially available, but the response times of those instruments are too long to enable temporal resolution of phenomena on the time scales of human respiration cycles. In contrast, the response time of the PUMA is significantly shorter than characteristic times of human respiration phenomena, making it possible to analyze varying metabolic parameters, not only on sequential breath cycles but also at successive phases of inhalation and exhalation within the same breath cycle. In operation, the PUMA is positioned to sample breath near the subject s mouth. Commercial off-the-shelf sensors are used for three of the measurements: a miniature pressure transducer for pressure, a thermistor for temperature, and an ultrasonic sensor for flow. Sensors developed at Glenn Research Center are used for measuring the partial pressures of oxygen and carbon dioxide: The carbon dioxide sensor exploits the relatively strong absorption of infrared light by carbon dioxide. Light from an infrared source passes through the stream of inhaled or exhaled gas and is focused on an infrared- sensitive photodetector. The oxygen sensor exploits the effect of oxygen in quenching the fluorescence of ruthenium-doped organic molecules in a dye on the tip of an optical fiber. A blue laser diode is used to excite the fluorescence, and the optical fiber carries the fluorescent light to a photodiode, the temporal variation of the output of which bears a known relationship with the rate of quenching of fluorescence and, hence, with the partial pressure of oxygen. The outputs of the sensors are digitized, preprocessed by a small onboard computer, and then sent wirelessly to a desktop computer, where the collected data are analyzed and displayed. In addition to the raw data on temperature, pressure, flow, and mole fractions of oxygen and carbon dioxide, the display can include volumetric oxygen consumption, volumetric carbon dioxide production, respiratory equivalent ratio, and volumetric flow rate of exhaled gas.

Dietrich, Daniel L.↗

Basin and Crater Ejecta Contributions to the South Pole-Aitken Basin (SPA) Regolith; Positive Implications for Robotic Surface Samples

The ability of impacts of all sizes to laterally transport ejected material across the lunar surface is well-documented both in lunar samples [1-4] and in remote sensing data [5-7]. The need to quantify the amount of lateral transport has lead to several models to estimate the scale of this effect. Such models have been used to assess the origin of components at the Apollo sites [8-10] or to predict what might be sampled by robotic landers [11-13]. Here we continue to examine the regolith inside the South Pole-Aitken Basin (SPA) and specifically assess the contribution to the SPA regolith by smaller craters within the basin. Specifically we asses the effects of four larger craters within SPA, Bose, Bhabha, Stoney, and Bellinsgauzen all located within the mafic enhancement in the center of SPA (Figure 1). The region around these craters is of interest as it is a possible landing and sample return site for the proposed Moon-Rise mission [14-17]. Additionally, understanding the provenance of components in the SPA regolith is important for interpreting remotely sensed data of the basin interior [18-20].

Petro, Noah E.↗

Acoustic Flight Test of the Joby Aviation Advanced Air Mobility Prototype Vehicle

An extensive acoustic flight test was performed on the Joby Aviation pre-production all-electric vertical takeoff and landing prototype. With the design intent of carrying a pilot and four passengers a maximum range of 150 miles, this vehicle utilizes distributed propulsion and vectored thrust via six tilting propellers. As part of the Advanced Air Mobility (AAM) National Campaign, this is the first full-scale AAM aircraft tested by NASA over representative conditions for all phases of a typical mission profile. A 58- channel distributed microphone array was used to acquire acoustic measurements on more than 100 test points (31 unique conditions). The measurements were postprocessed with synchronously sampled vehicle position and state data to form ground noise contours of departures and approaches at various flight path angles and accelerations. Comparing ground areas of 75 dBA isolines, approaches consistently exhibit higher noise levels rela- tive to departures. Directivity maps were generated for constant airspeed level flyovers. Examples comparing the differences in a semi-thrust borne and full wing-borne mode are given, with full wing-borne mode representing the quietest phase of the flight envelope tested. Measurements for hover in and out of ground effect are given and found to have 2 to 5 dB variation over a single run, and more significant variation between back-to-back runs. Finally, initial analysis of acoustic symmetry about the longitudinal vehicle axis and repeatability over several test days are presented.

Acoustics↗