Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resonator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Plasmonic nanoarcs: a versatile platform with tunable localized surface plasmon resonances in octave intervals

The tunability of the longitudinal localized surface plasmon resonances (LSPRs) of metallic nanoarcs is demonstrated with key relationships identified between geometric parameters of the arcs and their resonances in the infrared. The wavelength of the LSPRs is tuned by the mid-arc length of the nanoarc. The ratio between the attenuation of the fundamental and second order LSPRs is governed by the nanoarc central angle. Beneficial for plasmonic enhancement of harmonic generation, these two resonances can be tuned independently to obtain octave intervals through the design of a non-uniform arc-width profile. Because the character of the fundamental LSPR mode in nanoarcs combines an electric and a magnetic dipole, plasmonic nanoarcs with tunable resonances can serve as versatile building blocks for chiroptical and nonlinear optical devices.

42 ENGINEERING↗

Simultaneous Brillouin and piezoelectric coupling to a high-frequency bulk acoustic resonator

Bulk acoustic resonators support robust, long-lived mechanical modes, capable of coupling to various quantum systems. In separate works, such devices have achieved strong coupling to both superconducting qubits, via piezoelectricity, and optical cavities, via Brillouin interactions. In this work, we present a hybrid microwave–optical platform capable of coupling to bulk acoustic waves through cavity-enhanced piezoelectric and photoelastic interactions. The modular, tunable system achieves fully resonant and well-mode-matched interactions among a 3D microwave cavity, a high-frequency bulk acoustic resonator, and a Fabry–Perot cavity. We realize this piezo–Brillouin interaction in x-cut quartz, demonstrating the potential for strong optomechanical interactions and high cooperativity using optical cavity enhancement. We further show how this device functions as a bidirectional electro–opto–mechanical transducer, with transduction efficiency exceeding 10 − <#comment/> 8 , and a feasible path towards unity conversion efficiency. The high optical sensitivity and ability to apply a large resonant microwave field in this system also offers a tool for probing anomalous electromechanical couplings, which we demonstrate by investigating (nominally centrosymmetric) C a F 2 and revealing a parasitic piezoelectricity of 83 am/V. Such studies are an important topic for emerging quantum technologies, and highlight the versatility of this hybrid platform.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2D material platform for overcoming the amplitude–phase tradeoff in ring resonators

Compact and high-speed electro-optic phase modulators play a vital role in various large-scale applications including optical computing, quantum and neural networks, and optical communication links. Conventional electro-refractive phase modulators such as silicon (Si), III-V and graphene on Si suffer from a fundamental tradeoff between device length and optical loss that limits their scaling capabilities. High-finesse ring resonators have been traditionally used as compact intensity modulators, but their use for phase modulation has been limited due to the high insertion loss associated with the phase shift. Here, we show that high-finesse resonators can achieve a strong phase shift with low insertion loss by simultaneous modulation of the real and imaginary parts of the refractive index, to the same extent, i.e., Δ n Δ k ∼1. To implement this strategy, we demonstrate an active hybrid platform that combines a low-loss SiN ring resonator with 2D materials such as graphene and transition metal dichalcogenide [tungsten disulphide (WSe 2 )], which induces a strong change in the imaginary and real parts of the index. Our platform consisting of a 25 µm long Gr-Al 2 O 3 -WSe 2 capacitor embedded on a SiN ring of 50 µm radius (∼8% ring coverage) achieves a continuous phase shift of (0.46±0.05) π radians with an insertion loss (IL) of 3.18±0.20 dB and a transmission modulation (Δ T Ring ) of 1.72±0.15dB at a probe wavelength ( λ p ) of 1646.18 nm. We find that our Gr-Al 2 O 3 -WSe 2 capacitor exhibits a phase modulation efficiency ( V π 2 ⋅ L ) of 0.530±0.016V⋅cm and can support an electro-optic bandwidth of 14.9±0.1GHz. We further show that our platform can achieve a phase shift of π radians with an IL of 5 dB and a minimum Δ T of 0.046 dB. We demonstrate the broadband nature of the binary phase response, by measuring a phase shift of (1.00±0.10) π radians, with an IL of 5.20±0.31dB and a minimal Δ T Ring of 0.015±0.006dB for resonances spanning from 1564 to 1650 nm. This SiN–2D hybrid platform provides the design for compact and high-speed reconfigurable circuits with graphene and transition metal dichalcogenide (TMD) monolayers that can enable large-scale photonic systems.

Datta, Ipshita (ORCID:0000000318842882)↗

Enhanced biochemical sensing with high- Q transmission resonances in free-standing membrane metasurfaces

Optical metasurfaces provide solutions to label-free biochemical sensing by localizing light resonantly beyond the diffraction limit, thereby selectively enhancing light–matter interactions for improved analytical performance. However, high-Q resonances in metasurfaces are usually achieved in the reflection mode, which impedes metasurface integration into compact imaging systems. Here, we demonstrate a metasurface platform for advanced biochemical sensing based on the physics of the bound states in the continuum (BIC) and electromagnetically induced transparency (EIT) modes, which arise when two interfering resonances from a periodic pattern of tilted elliptic holes overlap both spectrally and spatially, creating a narrow transparency window in the mid-infrared spectrum. We experimentally measure these resonant peaks observed in transmission mode (Q ~ 734 at λ ~ 8.8 µm) in free-standing silicon membranes and confirm their tunability through geometric scaling. We also demonstrate the strong coupling of the BIC-EIT modes with a thinly coated PMMA film on the metasurface, characterized by a large Rabi splitting (32 cm -1 ) and biosensing of protein monolayers in transmission mode. Our new photonic platform can facilitate the integration of metasurface biochemical sensors into compact and monolithic optical systems while being compatible with scalable manufacturing, thereby clearing the way for on-site biochemical sensing in everyday applications.

Rosas, Samir [Univ. of Wisconsin, Madison, WI (Uni↗

Third-Order Resonance Compensation at the FNAL Recycler Ring

The Recycler Ring (RR) at the Fermilab Accelerator Complex performs slip-stacking on 8 GeV protons, doubling the beam intensity delivered to the Main Injector (MI). At MI, the beam is accelerated to 120 GeV and delivered to the high energy neutrino experiments. Femilab’s Proton Improvement Plan II (PIP-II) will require the Recycler to store 50% more beam. Simulations have shown that the space charge tune shift at this new intensity will lead to the excitation of multiple resonance lines. Specifically, this study looks at normal sextupole lines 3 Q_{x}=76 and Q_{x}+2Q_{y}=74, plus skew sextupole lines 3 Q_{y}=73 and 2 Q_{x}+Q_{y}=75. Dedicated normal and skew sextupoles have been installed in order to compensate for these resonance lines. By measuring and calculating the Resonance Driving Terms (RDT), this study shows how each of the resonance lines can be compensated independently. Furthermore, this study shows and discusses initial investigations into compensating multiple lines simultaneously.

43 PARTICLE ACCELERATORS↗

Resonance compensation at the CERN PS booster aided by Bayesian optimization and BOBYQA

The CERN Proton Synchrotron Booster (PSB) operation involves the crossing of multiple resonance lines in the tune diagram. Loss maps from dynamic tune scans are a helpful way to visualize and quantify the strength of such resonances. Sextupole and octupole correctors can be used in order to partially or fully compensate multiple resonance lines, i.e., third and fourth order lines. The following work explores the application of advanced optimization algorithms such as Bayesian Optimization and Bound Optimization By Quadratic Approximation (BOBYQA) in order to compensate these resonance lines with available correctors.

43 PARTICLE ACCELERATORS↗

Third integer resonant extraction transit time simulation studies

In this work, we present the investigation of transit time of particles in the non-linear third-integer resonant extraction process. Transit time is defined as the number of turns a particle takes to get extracted once it is in the unstable region in the phase space, i.e., outside the triangular separatrix in case of third-integer resonance. The study of transit time is important because transit time directly contributes to the beam response time during resonant extraction and thus knowing it apriori would be practically useful in designing of the extraction system. In this work, we shall investigate the analytical derivation of the transit time of particles (to the first order Kobayashi Hamiltonian) in different parts of the phase space distribution and compare against the analytical results. We also compare the simulation result of the transit time of particles (with higher statistics) for the static as well as dynamic extraction conditions cases, particularly in the context of resonant extraction parameters for Mu2e experiment at Fermilab.

Narayanan, Aakaash [Fermilab]↗

Multi-Axis Resonant Plate Shock Testing Evaluation and Test Specification Development

Resonant plate testing is a shock test method that is frequently used to simulate pyroshock events in the laboratory. Recently, it was discovered that if the unit under test is installed at an off-center location, a tri-axial accelerometer would record a shock response in three directions and the resulting shock response spectra implied that the test may have qualified the component in three directions simultaneously. The purpose of this research project was to evaluate this idea of multi-axis shock testing to determine if it was truly a multi-axis shock environment and if such a test could be used as an equivalent component qualification test. A study was conducted using generic, additively manufactured components tested on a resonant plate, along with an investigation of plate motion to evaluate the component response to off- center plate excitation. The data obtained here along with the analytical simulations performed indicate that off-center resonant plate tests are actually not three-axis shock tests, but rather single axis shocks at an arbitrary angle dictated by the location of the unit under test on the plate. This conclusion is supported by the fact that only one vectored shock input is provided to the component in a resonant plate test. Thus, the output response is a coupled response of the transverse plate vibration and the rotational motion of the component on the plate. Additionally, a multi-axis shock test defined by three single axis test environments always results in a significant component over-test in one direction.

42 ENGINEERING↗

Search for resonance in inclusive and b-tagged dijet mass spectra in proton-proton collision at $\sqrt{s}$ = 13 TeV and constraints on dark matter and other models

Two analyses searching for new heavy resonances and interpreting the result with dark matter are presented in this dissertation. The first analysis searches for resonances decaying into dijet final states using the proton-proton collision data at center mass of $\sqrt{s}=13$ TeV with the CMS detector at Large Hadron Collider in2016, corresponding to a total integrated luminosity of 36 fb -1 . No significant evidence for the production of new particles is observed. A simplified model of interactions between quarks and dark matter is used to interpret the result. The second analysis searches for resonances decaying into dijet final states using the proton-proton collision data at center mass of $\sqrt{s}=13$ TeV with the CMS detector at Large Hadron Collider in 2016, 2017, and 2018, corresponding to a total integrated luminosity of 137.5 fb -1 . A b-tagger named DeepJet is used to examine the events with jets containing B hadrons. No evidence of new heavy resonances is observed, as well. The 95% confidence level cross-section upper limit is set on excited b-quark b* and Coloron models. Limits are also set on a simplified model of interactions between b-quarks and dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Expansion of Machine-Learning Method for Classifying Neutron Resonances

The understanding of astrophysics processes and the performance of nuclear reactors and other nuclear systems depend on a precise description of the neutron interaction cross sections for materials and nuclei present in these environments. At low neutron energies, these cross sections exhibit resonance structure represented by sharp enhancements when the neutron energy is sufficiently close to excited levels in a compound nucleus. Such resonances can be characterized by their quantum numbers relative to angular momenta, which are often deduced in an ad hoc and irreproducible manner from the shape of the cross sections. The correct assignment of the quantum numbers of neutron resonances is therefore of paramount importance. To address this we have developed a machine-learning method to automate the identification and correction of these spin assignments. The algorithm is trained from simulated data, generated from statistical properties of resonance data for a given nucleus, to mimic the errors found in real data. In this project we describe five independent approaches to further develop and expand the applicability of the machine-learning spin classifier: i) Feature impact; ii) Integration with the Atlas; iii) Training optimization; iv) Spacings systematics; and v) Validation with polarized data. The premises, methods, results, and future perspectives are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Testing, Characterization, and Modeling of the Resonant Plate Test Environment

The resonant plate shock test is a dynamic test of a mid-field pyroshock environment where a projectile is struck against a plate. The structure undergoing the simulated field shock is mounted to the plate. The plate resonates when struck and provides a two sided shock that is representative of the shock observed in the field. This test environment shock simulates a shock in a single coordinate direction for components looking to provide evidence that they will survive a similar or less shock when deployed in their operating environment. However, testing in one axis at a time provides many challenges. The true environment is a multi-axis environment. The test environment exhibits strong off-axis motion when only motion in one axis is desired. Multiple fixtures are needed for a single test series. It would be advantageous if a single test could be developed that tests the multi-axis environment simultaneously. In order to design such a test, a model must be developed and validated. The model can be iterated in design and configuration until the specified multi-axis environment is met. The test can then execute the model driven test design. This report discusses the resonant plate model needed to design future tests and the steps and methods used to obtain the model. This report also details aspects of the resonant plate test discovered during the process of model development that aids in our understanding of the test.

42 ENGINEERING↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Resonance Parameter Evaluation of n + 88 Sr reactions for ENDF/B-VIII.1 Library

An evaluation of n+ 88 Sr reactions up to 950 keV was compiled from a publicly available set of resonance parameters. Starting from the repository of the ENDF/B-VIII.0 library, an evaluated nuclear data file was assembled and submitted for inclusion to the Evaluated Nuclear Data File (ENDF)/B-VIII.1 release. This evaluation features an external function representation defined by pole strengths and R ∞ parameters over the entire resolved resonance range. This work improves the modeling of the R-matrix parameterization from multi-Level Breit-Wigner resonance parameters to Reich-Moore formalism, and it also extends thrice the upper energy range of the current ENDF/B-VIII.0 resolved resonance evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical Simulation of Infrasound Resonance in Underground Tunnel Structures

Remote observation of infrasound resonant signals emanating from underground tunnel structures could potentially allow the remote quantification of the geometry of the underground structures in which the signals were generated. However, the sensitivity of these observations to tunnel geometry and changes in that geometry are unknown. In this report we outline a numerical simulation study with the following three objectives: 1. Can we model infrasound resonance using numerical simulations? 2. What is the sensitivity of the modeled observations to changes in tunnel geometry or boundary conditions? And 3. Can we accurately model resonant observations of explosions occurring in Redmond Salt Mine in Central Utah. In this report we outline affirmative answers to the first two objectives, but we were unable to accurately model the Redmond Explosions due to numerical instability in the model of the complex structure of the mine. Recommendations for future work emphasize the need to acquire additional datasets and to explore a more data-based approach in which changes in data signatures are detected as a first step towards developing a method which inverts resonant infrasound signals for tunnel geometry.

47 OTHER INSTRUMENTATION↗

Robust resonator-assisted ZZ cancellation in superconducting quantum processors

Strong qubit interactions are essential for faster two-qubit gates, but they often come with undesirable ZZ interactions that limit gate fidelity. Existing methods to mitigate these interactions, such as flux-tunable couplers, can introduce additional noise and complexity. In contrast, our work presents a simpler, more robust approach using a driven resonator to cancel the static ZZ interaction between qubits [1]. The experiment was performed on a revised 9-qubit quantum processing unit from Rigetti, developed in collaboration with SQMS scientists. We validate the resonator-induced-phase (RIP) interaction, where an off-resonant drive on the resonator dynamically cancels ZZ coupling. This marks an important step toward high gate fidelities. We also explore the entangling gates enabled by this coupling scheme, focusing on minimizing gate duration and qubit decoherence while maintaining effective ZZ cancellation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Third Integer Resonant Extraction Transit Time Simulation Studies

In this work, we present the investigation of transit time of particles in the non-linear third-integer resonant extraction process. Transit time is defined as the number of turns a particle takes to get extracted once it is in the unstable region in the phase space, i.e., outside the triangular separatrix in case of third-integer resonance. The study of transit time is important because transit time directly contributes to the beam response time during resonant extraction and thus knowing it apriori would be practically useful in designing of the extraction system. In this work, we shall investigate the analytical derivation of the transit time of particles (to the first order Kobayashi Hamiltonian) in different parts of the phase space distribution and compare against the analytical results. We also compare the simulation result of the transit time of particles (with higher statistics) for the static as well as dynamic extraction conditions cases, particularly in the context of resonant extraction parameters for Mu2e experiment at Fermilab.

Narayanan, Aakaash [Fermilab] (ORCID:0000000157944↗