Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiphysics Modeling of Microreactors with NEAMS codes, and Validation Based on KRUSTY Reactivity Insertion

The NEAMS Multiphysics Applications team continues to assess code usability and functionality for microreactor design and safety analyses, while demonstrating that NEAMS tools capture both steady-state and transient behavior across distinct microreactor concepts. In FY2025, the team advanced full-core, high-fidelity, multiphysics models that solve more complex problems and strengthen verification/validation for several microreactor systems: heat-pipe microreactor (HPMR), gas-cooled microreactor (GCMR), and the KRUSTY experiment. These models employ the MOOSE MultiApp/Transfers architecture with Griffin for neutronics, BISON for heat conduction/thermomechanics, Sockeye for heat pipes, SAM/THM for coolant channels and loops, and SWIFT for hydride behavior, with meshes generated via the MOOSE Reactor Module. The graphite models available in the Grizzly code were also investigated for future analyses. For the HPMR, a Na-HPMR variant was constructed to align with recently validated heat-pipe experiments and Sockeye’s LCVF capability, enabling mechanistic heat-pipe transients and startup modeling. The Na-HPMR will serve as the primary model for HPMR investigations in upcoming tasks. The load-following and single heat-pipe failure scenarios (Griffin/BISON/Sockeye), which were previously modeled for the K-HPMR, were replicated for the Na-HPMR, showing strong negative temperature feedback and highly localized thermal effects, respectively, while the startup case captured vapor-front progression and heat-removal activation. Solid mechanics was added to the previously built K-HPMR full-core model in BISON, showing minimal impact on steady-state reactivity yet enabling stress-field predictions that prepare the path for full-core TRISO performance analyses. For the GCMR, automated steady-state and four transient scenarios were executed using Griffin/BISON/SAM/SWIFT. Results confirm robust inherent safety: power collapses promptly in loss-of-cooling events, the inlet-temperature drop settles to a new equilibrium, and a single-channel blockage yields only a ~30 K local fuel-temperature rise with <0.4% power decrease. SWIFT-predicted hydrogen redistribution affects reactivity during both steady-state and transient conditions, underscoring its importance. A Brayton-cycle balance of plant (BOP) model in SAM/THM demonstrated stable startup behavior, and xenon-driven reactivity during load following was analyzed. To improve TRISO-compact temperature fidelity, a fast multiscale Heat Source Decomposition (HSD) treatment was implemented. Against heterogeneous benchmarks, HSD reduces underprediction of kernel temperatures and lowers predicted peak powers in reactivity-insertion transients compared to previous homogenized models. KRUSTY warm-critical validation progressed from FY2024 baselines: the 15Ȼ insertion shows excellent agreement in peak power (~2% high) and temperature trends, and the 30Ȼ case was automated via a feedback controller that maintained power near 3 kW for ~150 s with close agreement to data. The successful modeling of the warm critical tests has laid a strong foundation for simulating more complex nuclear system tests in the years ahead. Throughout FY2025, developer feedback was provided (e.g., MOOSE batch mesh generation, distributed pre-split meshes, Griffin sweeper on displaced meshes), several new models were contributed to the Virtual Test Bed, and an OECD-NEA WPRS multiphysics benchmark based on the HPMR was initiated to enable broader cross-comparison and best-practice development with the nuclear community at large.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary design for a space based orbital transfer vehicle

A space-based orbital transfer vehicle has been sized for a 50-metric-ton payload delivery from low-earth-orbit to a geosynchronous orbit. Space basing effected substantial reductions in cryogenic insulation, tank, and body structure. The tank and body structural masses are shown to be lower for space basing because of the larger difference in acceleration loads between the on-orbit case (0.2 g's) and delivery (3.0 g's), the latter applying to ground-based vehicles which are delivered to orbit fully loaded with propellants. Insulation masses are lower because of the absence of an atmosphere and the attendant heat transfer losses. Insulation systems masses are also reduced because of the elimination of the problem of liquefaction and freezing of moisture on the tanks.

Macconochie, I. O.↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Improving solar panel durability through novel panel designs and advanced manufacturing equipment

Work in the project was spread across 4 main themes:1) Improved Understanding of Why Cracks Form and Cause Degradation in Solar Cells: We developed a finite element model which correlated well with experimental determined deflection vs load profiles and which predicted stress profiles vs load level and temperature. These profiles helped to guide brace designs and showed the high stress levels seen in the silicon near the interconnect wire locations as the temperature is cooled below -30C, likely forming "invisible" microcracks. Experiments showed how for polymer backsheet modules, a brief exposure to such low temperatures made modules extremely sensitive to propagation of these microcracks at relatively low load levels, and how thicker and softer encapsulant helped to reduce this crack sensitivity. We showed for some modules that most cracks that are seen under loading had their origin at short, hard to see, V-cracks from soldering damage, and how the shunting from cells with high densities of cracks reduces energy delivery more than Pmax. 2) Improved Durability Testing Methods With Respect to Cracked Cells: We lobbied the PV community throughout the project that IEC 61215 was insufficient to probe the sensitivity of module Pmax degradation due to cracks in that in did not have a test leg that included a crack creation step (static loading) followed by a crack opening step (cyclic loading and/or thermal cycling). We published extensively on how pre- existing cracks opened up with cyclic loading. The new IEC TS 63209-1 ED1 test sequence now include our recommendations, and this should lead to improved module designs and reduced risk for investors. We also published recommendations for a new "Cold Climate Test" sequence to probe the sensitivity of modules to degradation from short microcracks formed when modules see temperatures below -30C followed by front side loading. We participated in several USTAG meetings related to cracked cells, EL testing, and mechanical load testing and provided input to the group to improve new standards under consideration. We also showed how the act of performing an EL test can affect the test results due to heating from the injected current. 3) New Module Designs and Related Manufacturing Methods & Equipment: We demonstrated reduced crack sensitivity on encapsulated cell coupons the benefits of building protective compressive stress into the cells by laminating them in a bent state and then allowing the coupon to flatten out after lamination. Our attempts to scale this to the module level with a more manufacturable sequence did not demonstrate the same positive effects, but we hope that others will follow up with other variations on this bent lamination or bent cooling concept to make more durable modules. 4) New Module Mounting Designs: We explored a range of bracing concepts which pressed on the backsheet to slightly bow the glass outward and place cells in a state of protective compressive stress and to reduce the deflection under front side loads. These successfully reduced cell cracking and crack opening, but high static loads permanently deformed cost-effective braces, after which they provided little benefit. We settled on an elegant & effective solution – the RailPad, where lightweight bracing elements are placed between the mounting rail(s) and the backsheet, and the existing strength of the rails is used to prevent module deflection under load. New construction and retrofit designs were made, and test sites were implemented in FL and MA. We applied for RailPad patent protection.

14 SOLAR ENERGY↗

Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Nuclear fusion could offer clean, abundant energy. However, managing the power exhausted from the core fusion plasma towards the reactor wall remains a major challenge. This is compounded in emerging compact reactor designs promising more cost-effective pathways towards commercial fusion energy. Alternative Divertor Configurations (ADCs) are a potential solution. In this work, we demonstrate exhaust control in ADCs, employing a novel method to diagnose the neutral gas buffer, which shields the target. Our work on the Mega Ampere Spherical Tokamak Upgrade shows that ADCs tackle key risks and uncertainties for fusion energy. Their highly reduced sensitivity to perturbations enables active exhaust control in otherwise unfeasible situations and facilitates an increased passive absorption of transients, which would otherwise damage the divertor. We observe a strong decoupling of each divertor from other reactor regions, enabling near-independent control of the divertors and core plasma. Our work showcases the real-world benefits of ADCs for effective heat load management in fusion power reactors.

Imaging techniques↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 1.58 kg (3.48 lbm), an additional 3.6 kg (8 lbm) of water are loaded into the unit, most of which is sublimated and lost to thus become the single largest expendable during an eight hour EVA. We can significantly reduce the amount of expendable water consumed in the sublimator by using a radiator to reject heat from the Astronaut during an EVA. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 260 W (900 Btu/h) of heat were rejected in Lunar and Mars environments with temperatures as cold as -170 C (- 275 F). Further, the RAFT-X endured several freeze / thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit.

Nabity, James↗

Cascaded hard X-ray self-seeded free-electron laser at megahertz repetition rate

High-resolution X-ray spectroscopy in the sub-nanosecond to femtosecond time range requires ultrashort X-ray pulses and a spectral X-ray flux considerably larger than that presently available. X-ray free-electron laser (XFEL) radiation from hard X-ray self-seeding (HXRSS) setups has been demonstrated in the past and offers the necessary peak flux properties. So far, these systems could not provide high repetition rates enabling a high average flux. We report the results for a cascaded HXRSS system installed at the European XFEL, currently the only operating high-repetition-rate hard X-ray XFEL facility worldwide. A high repetition rate, combined with HXRSS, allows the generation of millijoule-level pulses in the photon energy range of 6–14 keV with a bandwidth of around 1 eV (corresponding to about 1 mJ eV –1 peak spectral density) at the rate of ten trains per second, each train including hundreds of pulses arriving at a megahertz repetition rate. At 2.25 MHz repetition rate and photon energies in the 6–7 keV range, we observed and characterized the heat-load effects on the HXRSS crystals, substantially altering the spectra of subsequent X-ray pulses. We demonstrated that our cascaded self-seeding scheme reduces this detrimental effect to below the detection level. This opens up exciting new possibilities in a wide range of scientific fields employing ultrafast X-ray spectroscopy, scattering and imaging techniques.

47 OTHER INSTRUMENTATION↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapidly ramp cryogenic air separation unit without loss of O2 product purity—application for low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for low-carbon, fossil-fuel power plant capable of rapid ramping. Therefore, a cryogenic air separation unit (ASU) as part of low-carbon, fossil-fuel power plant should be capable of rapid ramping. However, highly integrated and nonlinear processes of the ASU would significantly restrict this rapid ramping. To overcome this fundamental issue, we study the basic dynamic process of a state-of-the-art double-column ASU. A flow-driven dynamic model was established in Aspen Plus Dynamics, assuming perfect flow controls, to capture the basic dynamics of ramping ASU. We find the vapor-liquid counter-current flow structure in the low-pressure column is critical to the air separation when rapidly ramping the ASU. This flow structure is established based on a complicated heat integration process. It is simplified as an apparent counter-current heat transfer process in this work, which greatly reduces the complexity for studying the dynamics of ASU. For keeping this basic flow structure, the heat integration is maintained as its heat duty follows the ASU load, through several basic feed-forward and feed-back controllers on the critical stream flowrates. Moreover, we find a fundamental issue of mismatched dynamics in the low-pressure column, resulting in a significant loss of O2 product purity when rapidly ramping down the ASU and an obvious fluctuation of O2 product purity. Based on these explorations, we propose a basic control method for rapidly ramping the ASU without loss of O2 product purity. Results show the ASU basic dynamic process successfully ramps at a rate up to 10%/min (40-100% load) while maintaining the O2 product purity within 95.2-95.6 mol%.

Cheng, Mao↗

Boiling on Microconfigured Composite Surfaces Enhanced

Boiling heat transfer is one of the key technologies for the two-phase active thermal-control system used on space platforms, as well as for the dynamic power systems aboard the International Space Station. Because it is an effective heat transfer mode, boiling is integral to many space applications, such as heat exchangers and other cooling devices. Nucleate boiling near the critical heat flux (CHF) can transport very large thermal loads with a much smaller device and much lower pumping power than for single-phase heat exchangers. However, boiling performance sharply deteriorates in a reduced-gravity environment, and operation in the CHF regime is somewhat perilous because of the risk of burnout to the device surface. New materials called microconfigured metal-graphite composites can enhance boiling. The photomicrograph shows the microconfiguration (x3000) of the copper-graphite (Cu-Gr) surface as viewed by scanning electronic microscope. The graphite fiber tips appear as plateaus with rugged surfaces embedded in the copper matrix. It has been experimentally demonstrated that this type of material manifests excellent boiling heat transfer performance characteristics and an increased CHF. Nonisothermal surfaces were less sensitive to variations of wall superheat in the CHF regime. Because of the great difference in conductivity between the copper base and the graphite fiber, the composite surfaces have a nonisothermal surface characteristic and, therefore, will have a much larger "safe" operating region in the CHF regime. In addition, the thermocapillary forces induced by the temperature differences between the fiber tips and the metal matrix play an important role in bubble detachment, and may not be adversely affected in a reduced-gravity environment. All these factors indicate that microconfigured composites may improve the reliability and economy (dominant factors in all space applications) of various thermal components found on spacecraft during future missions.

Chao, David F.↗

Assessing and Reducing Plug and Process Loads in Retail Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Concept for a manned Mars flyby

A concept is presented for a three man crew to fly by the planet Mars. The ground rule for the study is to execute the mission as quickly as possible which dictates using late 1990's technologies and space infrastructure. The proposed mission described herein uses a preliminary concept for the agency's Manned Orbit Transfer Vehicle (MOTV) and proposed space station elements. The space vehicle will depart from the LEO space station and is delivered to Low Earth Orbit (LEO) by a future launch vehicle of a Shuttle Derived Launch Vehicle (SDV) class. The trajectory parameters are chosen such that the mission duration is on the order of one year, with a two and one-half hour period within ten planetary radii of Mars. If the issues of acceptable crew g loads and entry vehicle heat load can be resolved, then the returning vehicle can aerobrake at Earth into a space station compatible orbit. Otherwise, a propulsive maneuver will be required to reduce vehicle velocity prior to Earth entry interface. It is possible to execute a mission of reasonable capability at an initial LEO departure weight of 716,208 pounds for the aerobraked case of 1,350,000 pounds for the propulsive case.

Barney B Roberts↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Effects of Accident Thermal Loading on In-Plane Shear Behavior of Steel-Plate Composite Walls

Structural walls in safety-related nuclear facilities are required to be designed for seismic and accident thermal (due to postulated high-energy pipe break events) loading combination. Current U.S. and international codes provide limited guidance for analysis and design of walls for this loading combination. This paper describes the experimental results and observations from tests conducted on a laboratory-scale (1:4 to 1:5) test unit representing steel-plate composite (SC) walls subjected to combined in-plane (seismic) and accident thermal loading. The test unit was subjected to surface temperatures of up to 450°F in combination with cyclic in-plane loading. Results of similar experiments recently conducted in Japan are also summarized (with surface temperatures up to 570°F). Surface heating combined with the low thermal conductivity and high specific heat of concrete resulted in nonlinear thermal gradients through the thickness of the specimens. These nonlinear thermal gradients and the associated self- or internal restraint led to extensive concrete cracking. This concrete cracking reduced the initial and secant stiffness of the specimens. The initial stiffness of the heated specimens reduced to 30 to 40% of the initial stiffness of the control (unheated) specimen. The secant stiffness of the heated specimens reduced up to 50% of the secant stiffness of the control (unheated) specimen. However, the in-plane shear strength of the heated SC specimens was still approximately 10 to 30% greater than the nominal in-plane shear strength calculated, for the limit state of steel plate von Mises yielding, using AISC N690 equations and measured material properties. Evaluation of the experimental results and observations suggests that the in-plane shear strength of SC walls subjected to typical accident surface temperatures (up to 570°F) can be estimated conservatively using the current provisions of AISC N690. The stiffness for accident thermal loading combinations can be considered to reduce from cracked composite stiffness at ambient temperature to fully cracked—that is, steel-only stiffness as the surface temperature increases up to typical accident value.

Construction & Building Technology↗