Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

How to Read the Snowmass White Papers on Power Dynamics in Physics, Informal Socialization in Physics Training, and Policing and Gatekeeping in STEM

The Community Engagement Frontier presents this set of three white papers, as part of Snowmass 2021. These papers address critical issues -- Power Dynamics in Physics, Informal Socialization in Physics Training, and Policing and Gatekeeping in STEM -- that make significant impacts on the experiences of the people who work in and learn particle physics. In this introductory document, we present crosscutting concepts that appear in each paper, and some advice on how to manage readers' responses to the contents. We expect that you will learn something new here. We hope that whatever you encounter, you will be energized to increase justice in this discipline we all love.

Hodari, Apriel K.↗

Erratum to: “The Fluorescence and Electronic Structure of Phenyl-Substituted Tetraazachlorin Molecules” [Optics and Spectroscopy 117, 722 (2014)]

should read “porphyrazine” instead of “porphyrazin”;should read “intersystem crossing” instead of “intercombinational conversion”;should read “mirror-symmetrical” instead of “reflection-symmetric”;should read “fluorescence enhancement” instead of “fluorescence buildup.”Page 722, Abstract, lines 9–10 from the top, the sentence should read:This characteristic increases upon tetrapyrrole phenylation.Page 727, left column, lines 17–18 from the top, the sentence should read:The vibronic transition parts of the emission spectrum are diffuse, (…)Page 727, left column, lines 29–30 from the top, the sentence should read:Note that the Stokes shift in these cases is relatively large.Page 729, left column, lines 8–10 from the bottom, the sentence should read:For H{sub 2}Ph{sub 8}TAC{sup mp} and H{sub 2}Ph{sub 6}TAC{sup tm}, the enhancement of fluorescence is weaker than in the former case: on cooling, τ{sub F} is increased by a factor of 4–5 in MTHF and by a factor of only 2.6–3 in toluene.Page 729, right column, lines 9–10 from the footnote, the sentence should read:It is seen from Table 1 that our results agree reasonably well with previously reported data.Page 730, left column, lines 16–19 from the top, the sentence should read:The lifetime for the outgassed H{sub 2}TAP solution intoluene (τ{sub T}{sup 0}) was measured by A.S. Stasheuski as phosphorescence decay at λ{sub reg} = 1070 nm using the setup described in [29].Page 730, left column, lines 20–23 from the top, the sentence should read:The τ{sub T} value derived from the kinetics of the rise of singlet oxygen luminescence [26] for the nonoutgassed solution at λ{sub reg} = 1272 nm is 162 ns;Page 730, right column, lines 25–27 from the top, the sentence should read:Therefore, for H{sub 2}TAP (λ{sub F}{sup 00}≈ 620 nm), the internal conversion probability should not be high.Page 731, left column, the heading of Table 2 should read:Bond lengths in the porphine macrocycle (Å).Page 731, left column, lines 3–6 from the top, the sentence should read:For elucidating the mechanism of the deactivation of the S{sub 1} state, it was of essential interest to see whether the enhancement of H{sub 2}TAP fluorescence would be observed at 77 K.Page 733, left column, lines 2–3 from the top, the sentence should read:The corresponding difference for the H{sub 2}P–H{sub 2}C pair is 0.013 Å.Page 733, left column, lines 14–16 from the top, the sentence should read:The macrocycle undergoes additional contraction, and the symmetry of its conjugated system is very close to D{sub 2h}.Page 733, right column, line 21 from the top should read:Replacement of the methine bridges (…)Page 734, left column, lines 8–11 from the figure caption, the sentence should read:This is the main reason of the large bathochromic shift of the Soret band of H{sub 2}Ph{sub 8}TAP and MgPh{sub 8}TAP [16] relative to H{sub 2}TAP and MgTAP, respectively.Page 734, left column, lines 1–4 from the bottom, the sentence should read:The complete INDO/Sm calculation yields the corresponding quantitative characteristics, which are in good agreement with experimental data (see below).Page 740, left column, reference no. 25 should read:25. V. A. Galievsky, A. S. Stasheuski, V. V. Kiselyov, A. I. Shabusov, M. V. Belkov, and B. M. Dzhagarov, Instrum. Exp. Tech. 53, 568 (2010).25. V. A. Galievsky, A. S. Stasheuski, V. V. Kiselyov, A. I. Shabusov, M. V. Belkov, and B. M. Dzhagarov, Instrum. Exp. Tech. 53, 568 (2010).30. V. L. Ermolaev and E. B. Sveshnikova, Acta Phys. Pol. 34, 771 (1968).

74 ATOMIC AND MOLECULAR PHYSICS↗

DNA Sequencing Using capillary Electrophoresis

The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other application papers of sequencing up to this level were also published in the mid 1990's. A major interest of the sequencing community has always been read length. The longer the sequence read per run the more efficient the process as well as the ability to read repeat sequences. We therefore devoted a great deal of time to studying the factors influencing read length in capillary electrophoresis, including polymer type and molecule weight, capillary column temperature, applied electric field, etc. In our initial optimization, we were able to demonstrate, for the first time, the sequencing of over 1000 bases with 90% accuracy. The run required 80 minutes for separation. Sequencing of 1000 bases per column was next demonstrated on a multiple capillary instrument. Our studies revealed that linear polyacrylamide produced the longest read lengths because the hydrophilic single strand DNA had minimal interaction with the very hydrophilic linear polyacrylamide. Any interaction of the DNA with the polymer would lead to broader peaks and lower read length. Another important parameter was the molecular weight of the linear chains. High molecular weight (> 1 MDA) was important to allow the long single strand DNA to reptate through the entangled polymer matrix. In an important paper, we showed an inverse emulsion method to prepare reproducibility linear polyacrylamide polymer with an average MWT of 9MDa. This approach was used in the polymer for sequencing the human genome. Another critical factor in the successful use of capillary electrophoresis for sequencing was the sample preparation method. In the Sanger sequencing reaction, high concentration of salts and dideoxynucleotide remained. Since the sample was introduced to the capillary column by electrokinetic injection, these salt ions would be favorably injected into the column over the sequencing fragments, thus reducing the signal for longer fragments and hence reading read length. In two papers, we examined the role of individual components from the sequencing reaction and then developed a protocol to reduce the deleterious salts. We demonstrated a robust method for achieving long read length DNA sequencing. Continuing our advances, we next demonstrated the achievement of over 1000 bases in less than one hour with a base calling accuracy of between 98 and 99%. In this work, we implemented energy transfer dyes which allowed for cleaner differentiation of the 4 dye labeled terminal nucleotides. In addition, we developed improved base calling software to help read sequencing when the separation was only minimal as occurs at long read lengths. Another critical parameter we studied was column temperature. We demonstrated that read lengths improved as the column temperature was increased from room temperature to 60 C or 70 C. The higher temperature relaxed the DNA chains under the influence of the high electric field.

59 BASIC BIOLOGICAL SCIENCES↗