Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

UV-Enhanced IR Raman System for Identifying Biohazards

An instrumentation system that would include an ultraviolet (UV) laser or light-emitting diode, an infrared (IR) laser, and the equivalent of an IR Raman spectrometer has been proposed to enable noncontact identification of hazardous biological agents and chemicals. In prior research, IR Raman scattering had shown promise as a means of such identification, except that the Raman-scattered light was often found to be too weak to be detected or to enable unambiguous identification in practical applications. The proposed system would utilize UV illumination as part of a two-level optical-pumping scheme to intensify the Raman signal sufficiently to enable positive identification.

Stirbl, Robert↗

Nearly degenerate two-color impulsive coherent Raman hyperspectral imaging

Impulsive stimulated Raman scattering (ISRS) is a robust technique for studying low frequency (<300 cm –1 ) Raman vibrational modes, but ISRS has faced difficulty in translation to an imaging modality. A primary challenge is the separation of the pump and probe pulses. Here we introduce and demonstrate a simple strategy for ISRS spectroscopy and hyperspectral imaging that uses complementary steep edge spectral filters to separate the probe beam detection from the pump and enables simple ISRS microscopy with a single-color ultrafast laser source. ISRS spectra are obtained that span from the fingerprint region down to <50 cm –1 vibrational modes. Furthermore, hyperspectral imaging and polarization-dependent Raman spectra are also demonstrated.

47 OTHER INSTRUMENTATION↗

Resonant propagation of x rays from the linear to the nonlinear regime

We present a theoretical study of temporal, spectral, and spatial reshaping of intense, ultrafast x-ray pulses propagating through a resonant medium. Our calculations are based on the solution of a three-dimensional time-dependent Schrodinger-Maxwell equation, with the incident x-ray photon energy on resonance with the core-level is-3p transition in neon. We study the evolution of the combined incident and medium-generated field, including the effects of stimulated emission, absorption, ionization, and Auger decay, as a function of the input pulse energy and duration. We find that stimulated Raman scattering between core-excited states 1s -1 3p and 2p -1 3p occurs at high x-ray intensity, and that the emission around this frequency is strongly enhanced when also including the similar 1s -1 -2p -1 response of the ion. We also explore the dependence of x-ray self-induced transparency (SIT) and self-focusing on the pulse intensity and duration, and we find that the stimulated Raman scattering plays an important role in both effects. Finally, we discuss how these nonlinear effects may potentially be exploited as control parameters for pulse properties of x-ray free-electron laser sources.

74 ATOMIC AND MOLECULAR PHYSICS↗

Local Intensity Enhancements in Spherical Microcavities: Implications for Photonic Chemical and Biological Sensors

In this report, we summarize recent findings regarding the use spherical microcavities in the amplification of light that is inelastically scattered by either fluorescent or Raman-active molecules. This discussion will focus on Raman scattering, with the understanding that analogous processes apply to fluorescence. Raman spectra can be generated through the use of a very strong light source that stimulates inelastic light scattering by molecules, with the scattering occurring at wavelengths shifted from that of the source and being most prominent at shifts associated with the molecules natural vibrational frequencies. The Raman signal can be greatly enhanced by exposing a molecule to the intense electric fields that arise near surfaces (typically of gold or silver) exhibiting nanoscale roughness. This is known as surface-enhanced Raman scattering (SERS). SERS typically produces gain factors of 103 - 106, but under special conditions, factors of 1010 - 1014 have been achieved.

Fuller, Kirk A.↗

Characterization of PuO 2 With Visible and UV Raman Spectroscopy: Discrimination Between the Bulk, Surface, and an Intermediate Disordered Layer

Raman spectroscopy is an ideal tool in the characterization of materials including PuO 2 . The wavelength-dependent absorptivity of the material defines the light penetration depth and the relative Raman scattering contribution from the bulk and the surface. Here, the surface contribution to the total Raman scattering was investigated for PuO 2 calcined at various temperatures and recorded with laser wavelengths of 355, 325, and 244 nm. These experiments provided the first glimpse of the wavelength-dependent disappearance and emergence of new phonons and electronic bands from the PuO 2 surface layers. The first indication of the wavelength transition in the Raman spectra was the loss of the 2LO2 (overtone, ~1155 cm -1 ) band and the weakening intensity of the Г 1 → Γ 5 electronic band (~2135 cm -1 ) with the 355-nm excitation laser. The Γ 5 electronic band was barely visible with the 244-nm excitation. The electronic band located at ~1050 cm -1 , corresponding to the Г 1 → Γ 4 electronic transition was observed to dramatically increase in intensity while the Г 1 → Γ 3 electronic band (2640 cm -1 ) sharpened as the UV wavelength was increased in energy from the near- to deep-UV (355–325–244 nm). The FWHM of the T 2g band was found to vary with calcination temperature (450°C and 900°C) with the 325-nm laser and the 244-nm laser. The T 2g band attributes, the strong emergence of the Г 1 → Γ 4 electronic band, and the disappearance of the 2LO2 overtone acquired with the 244-nm excitation for the different calcination temperatures suggest a shallow penetration depth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Examination of the Raman Lidar Technique for Water Vapor and Aerosols: Evaluating the Temperature Dependent Lidar Equations - Paper 1

The intent of this paper and its companion is to compile together the essential information required for the analysis of Raman lidar water vapor and aerosol data acquired using a single laser wavelength. In this first paper several details concerning the evaluation of the lidar equation when measuring Raman scattering are considered. These details include the influence of the temperature dependence of both pure rotational and vibrational-rotational Raman scattering on the lidar profile. These are evaluated for the first time using a new form of the lidar equation. The results indicate that, for the range of temperatures encountered in the troposphere, the magnitude of the temperature dependent effect can reach 10% or more for narrowband Raman water vapor measurements. Also the calculation of atmospheric transmission is examined carefully including the effects of depolarization. Different formulations of Rayleigh cross section determination commonly used in the lidar field are compared revealing differences up to 5% among the formulations. The influence of multiple scattering on the measurement of aerosol extinction using the Raman lidar technique is considered as are several photon pulse-pileup correction techniques.

Whiteman, David N.↗

Determining gas temperatures from laser scattering.

Lidar techniques may be applicable to inelastic, Raman scattering. When a light beam interacts with gas molecules, the energies of scattered photons may be increased or decreased relative to the incident photons. The Raman return signal can theoretically yield information on gas pressure, temperature, and molecular species concentration. The temperature can be calculated from the measurement of two scattered Raman rotational line intensities. Questions of measurement accuracy, line selection, and multiple line ratios are considered. The measurement apparatus is discussed together with the measurement techniques.

Salzman, J. A.↗

Raman-Augmented Stratospheric-Ozone Lidar

Differential-absorption lidar (DIAL) system measures concentration of ozone in stratosphere augmented with subsystem measuring Raman scattering from nitrogen. One of number of DIAL systems used in long-term monitoring of stratospheric ozone. Raman scattering from nitrogen provides data to correct for effects of aerosols. Channels at wavelengths of 332 and 385 nm added to DIAL receiver to measure Raman backscattering from nitrogen molecules in stratosphere. Data-acquisition electronics sample photon counts at a rate of 250 MHz.

Mcdermid, I. Stuart↗

Gaseous hydrogen/oxygen injector performance characterization

Results are presented of spontaneous Raman scattering measurements in the combustion chamber of a 110 N thrust class gaseous hydrogen/oxygen rocket. Temperature, oxygen number density, and water number density profiles at the injector exit plane are presented. These measurements are used as input profiles to a full Navier-Stokes computational fluid dynamics (CFD) code. Predictions of this code while using the measured profiles are compared with predictions while using assumed uniform injector profiles. Axial and radial velocity profiles derived from both sets of predictions are compared with Rayleigh scattering measurements in the exit plane of a 33:1 area ratio nozzle. Temperature and number density Raman scattering measurements at the exit plane of a test rocket with a 1:1.36 area ratio nozzle are also compared with results from both sets of predictions.

Degroot, W. A.↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

Verification measurement of a polarization Raman elastic-backscatter lidar

By measuring the depolarization of light Raman scattered from a gas of known number density (nitrogen), it is possible to determine the influence of multiple scattering on lidar signals. In order to realize such measurements, linearly polarized laser light is emitted and two components of the nitrogen Raman signals, with E vectors parallel (parallel P sub lambda R) and perpendicular (perpendicular P sub lambda R) to the plane of polarization of the laser light, are measured. The depolarization ratio, delta sub lambda R = perpendicular P sub lambda R/parallel P sub lambda R, is constant if only the Raman scattering process contributes to the signal. Any variation of the depolarization is caused by additional elastic, and, thus, multiple scattering. If the contribution of multiple scattered light to the lidar signals is known, other parameters determined with the systems such as extinction, backscattering, and the depolarization of elastically scattered light, can be corrected for this influence. The lidar system used for the polarization measurements, especially the receiver setup, is described. The calibration of the apparatus and a clear air measurement are discussed.

Schulze, Christoph↗

Laser Raman sensor for measurement of trace-hydrogen gas

A new optical hydrogen sensor based on spontaneous Raman scattering of laser light has been designed and constructed for rugged field use. It provides good sensitivity, rapid response, and the inherent Raman characteristics of linearity and background gas independence of the signal. Efficient light collection and discrimination by using fast optics and a bandpass interference filter compensate for the inefficiency of the Raman-scattering process. A multipass optical cavity with a Herriott-type configuration provides intense illumination from an air-cooled CW gas laser. The observed performance is in good agreement with the theoretical signal and noise level predictions.

Adler-Golden, Steven M.↗

Fe-Ti-Cr-Oxides in Martian Meteorite EETA79001 Studied by Point-counting Procedure Using Raman Spectroscopy

Fe-Ti-Cr-Oxide minerals contain much information about rock petrogenesis and alteration. Among the most important in the petrology of common intrusive and extrusive rocks are those of the FeO-TiO2-Cr2O3 compositional system chromite, ulv spinel-magnetite, and ilmenite-hematite. These minerals retain memories of oxygen fugacity. Their exsolution into companion mineral pairs give constraints on formation temperature and cooling rate. Laser Raman spectroscopy is anticipated to be a powerful technique for characterization of materials on the surface of Mars. A Mars Microbeam Raman Spectrometer (MMRS) is under development. It combines a micro sized laser beam and an automatic point-counting mechanism, and so can detect minor minerals or weak Raman-scattering phases such as Fe- Ti-Cr-oxides in mixtures (rocks & soils), and provide information on grain size and mineral mode. Most Fe-Ti-Cr-oxides produce weaker Raman signals than those from oxyanionic minerals, e.g. carbonates, sulfates, phosphates, and silicates, partly because most of them are intrinsically weaker Raman scatters, and partly because their dark colors limit the penetration depth of the excitation laser beam (visible wavelength) and of the Raman radiation produced. The purpose of this study is to show how well the Fe-Ti-Cr-oxides can be characterized by on-surface planetary exploration using Raman spectroscopy. We studied the basic Raman features of common examples of these minerals using well-characterized individual mineral grains. The knowledge gained was then used to study the Fe-Ti-Cr-oxides in Martian meteorite EETA79001, especially effects of compositional and structural variations on their Raman features.

Wang, Alian↗

Suppression of power losses during laser pulse propagation in underdense plasma slab

For current state-of-the-art terawatt lasers, the primary laser scattering mechanisms in plasma include Forward Raman Scattering (FRS), excitation of plasma waves, and the self-modulational instability (SMI). Using 2D PIC simulations, we demonstrate the dominance of the FRS in the regime with medium-to-low density plasma and non-relativistic laser fields. However, the use of multi-colored lasers with frequency detuning exceeding the plasma frequency, Δω > ω pe , suppresses the FRS. Finally, the laser power can then be transmitted efficiently.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanophotonics for Chemical Imaging and Spectroscopy

The manipulation of light and light-matter interactions on the nanoscale is enabled by the unique optical properties of plasmonic metal nanostructures and nanoparticles. Indeed, engineered hybrid molecular-plasmonic nanostructures have enabled single molecule detection and identification via surface-enhanced Raman scattering (SERS). Further, the same effect is at the core of visualizing single molecules with sub-nanometer spatial resolution via tip-enhanced Raman scattering (TERS). More generally, modern applications of plasmon-enhanced spectroscopy and microscopy fueled advances in fields as diverse as quantum and semiconductor materials, heterogeneous catalysis, and the health sciences, to name a few. All these exciting developments and many more are touched in this virtual special issue (VSI) on nanophotonics. From ultra-precise chemical imaging measurements performed in a scanning tunneling microscope chamber to single molecule spectroscopic measurements performed at solid-air and solid-liquid interfaces, this VSI includes contributions from active practitioners that are all striving to better-understand increasingly complex interfaces encountered in the biological, materials, and chemical sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development of a fiber optic Raman temperature measurement system for rocket flows

A fiber-optic Raman diagnostic system for H2/O2 rocket flows is currently under development. This system is designed for measurements of temperature and major species concentration in the combustion chamber and part of the nozzle of a 100 Newton thrust rocket currently undergoing tests. This paper describes a measurement system based on the spontaneous Raman scattering phenomenon. An analysis of the principles behind the technique is given. Software is developed to measure temperature and major species concentration by comparing theoretical Raman scattering spectra with experimentally obtained spectra. Equipment selection and experimental approach are summarized. This experimental effort is part of a program, which is in progress, to evaluate Navier-Stokes based analyses for this class of rockets.

De Groot, Wim A.↗

The Development of a Fiber Optic Raman Temperature Measurement System for Rocket Flows

A fiberoptic Raman diagnostic system for H2/O2 rocket flows is currently under development. This system is designed for measurement of temperature and major species concentration in the combustion chamber and part of the nozzle of a 100 Newton thrust rocket currently undergoing testing. This paper describes a measurement system based on the spontaneous Raman scattering phenomenon. An analysis of the principles behind the technique is given. Software is developed to measure temperature and major species concentrations by comparing theoretical Raman scattering spectra with experimentally obtained spectra. Equipment selection and experimental approach are summarized. This experimental program is part of a program, which is in progress, to evaluate Navier-Stokes based analyses for this class of rocket.

Degroot, Wim A.↗

Spin-lattice entanglement in CoPS 3

Complex chalcogenides in the 𝑀⁢PS 3 family of materials (𝑀 =Mn, Fe, Co, and Ni) display remarkably different phase progressions depending upon the metal center orbital filling, character of the P–P linkage, and size of the van der Waals gap. There is also a stacking pattern and spin-state difference between the “lighter” and “heavier” transition-metal-containing systems that places CoPS 3 at the nexus of these activities. Despite these unique properties, this compound is underexplored. Here, we bring together Raman scattering spectroscopy and infrared absorption spectroscopy with x-ray techniques to identify a structural component to the 119 K magnetic ordering transition. With temperature-dependent Raman scattering, we discover a set of magnon-phonon pairs that engages in avoided crossings below 𝑇 Néel . Lastly, these findings point to strong spin-phonon entanglement as well as opportunities to control these effects under external stimuli.

Magnetism↗