Picosecond-resolved X-ray absorption spectroscopy at low signal contrast using a hard X-ray streak camera

A picosecond-resolving hard-X-ray streak camera has been in operation for several years at Sector 7 of the Advanced Photon Source (APS). Several upgrades have been implemented over the past few years to optimize integration into the beamline, reduce the timing jitter, and improve the signal-to-noise ratio. These include the development of X-ray optics for focusing the X-rays into the sample and the entrance slit of the streak camera, and measures to minimize the amount of laser light needed to generate the deflection-voltage ramp. For the latter, the photoconductive switch generating the deflection ramp was replaced with microwave power electronics. With these, the streak camera operates routinely at 88 MHz repetition rate, thus making it compatible with all of the APS fill patterns including use of all the X-rays in the 324-bunch mode. Sample data are shown to demonstrate the performance.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Model-based approaches to calibration and certification of nondestructive assay systems - 15615

Increasingly, model-based methods founded in physics are employed to calibrate, or extend the calibration of, nondestructive assay (NDA) systems used to characterize materials contaminated with plutonium, uranium, and other radioactive isotopes. In addition, modeling and mathematical methods are used to establish system parameters, correction factors, and measurement uncertainty components in NDA measurements. The methods combine the characteristics of the measurement configuration (detector structure, object shape and dimensions, source-detector distance and orientation, and collimation), generator knowledge of the waste composition, and known physical properties of the system in order to establish these parameters, factors, and components. These methods offer several important benefits over traditional methods used to test, calibrate, operate, and certify radiation measurement systems. First, instruments can be set up and put into service more quickly and correctly using a model-based approach. Second, calibrations can be performed, tested, and modified with reduced use of plutonium and uranium standards when modeling and mathematical methods are employed. Also, modeled approaches avoid calibration error resulting from heterogeneous source distribution. Moreover, the parameters can be installed quickly and simply in an office setting without the need for the safety, security, and safeguards considerations that are present when standards are used. Calibrations can also be tailored to fit unique or nonstandard container configurations (for example, over-packed drums), new container types, or specialized matrices. Finally, when modeling methods are applied, correction factors and measurement uncertainty elements can be developed, tested, and validated relatively quickly and without the need for surrogate matrix materials and a large number of test measurements. A combined gamma and neutron NDA system has recently been moved from Idaho National Laboratory to the TA 55 facility at Los Alamos National Laboratory (LANL). The system will be used to assay transuranic waste packaged in drums. After the move, the system was modified to replace degraded components and improve system performance. Afterwards, it was set up to assay different container types and to extend the calibration range. Model-based approaches were used to adapt the system to its new purpose at LANL. This report will describe the setup, calibration, and certification of the combined system at LANL Included in this discussion will be the measurement applications and details of the measurement methods. The steps in these processes that involved the use of modeling and mathematical calculations to replace or supplement more traditional methods will be identified and discussed. Finally, an overarching discussion of the methods and advantages of model-based methods to establish the properties of NDA systems will be presented. We conclude that validated mathematical methods offer a robust, flexible, and mature approach which is technically defensible from first principle physics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A new solid state extractor pulser for the FNAL magnetron ion source

A new solid state extractor pulser has been installed on the Fermi National Accelerator Laboratory (FNAL) magnetron ion source, replacing a vacuum tube style pulser that was used for over 40 years. The required ion source extraction voltage is 35 kV for injection into the radio frequency quadrupole. At this voltage, the old pulser had a rise time of over 150 μs due to the current limit of the vacuum tube. The new solid state pulsers are capable of 50 kV, 100 A peak current pulses and have a rise time of 9 μs when installed in the operational system. This paper will discuss the pulser design and operational experience to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cheesecloth Alternatives Testing

Heat source plutonium oxide (HS-PuO 2 ) enriched with 65% or greater plutonium-238, is recovered and purified using an aqueous nitric acid process. Historically, cheesecloth has been employed for small spill clean-up and for routine housekeeping. However, the 2016 Department of Energy (DOE) Operating Experience report, entitled Nitrate Waste Evaluations, stated that the mixing of nitrate wastes with organic absorbents, such as cheesecloth, may render transuranic waste unacceptable for disposal at WIPP in the future. This report explores the feasibility of replacement of cheesecloth with an alternative sorbent wipe that has similar absorption and cleaning abilities and improved acid resistance. Currently, cheesecloth is used for three different functions in HS-PuO 2 operations: spill cleanup; general housekeeping operations such as cleaning glovebox floors and windows, balances, furnaces, etc.; and decontamination of iridium cladded heat sources containing HS-PuO 2 . Alternatives used for spill cleanup must be able to tolerate high neutron doses found in the HS-Pu gloveboxes. They must also be able to withstand exposure to nitric acid concentrations up to 15.8 M without decomposing. Wipes used for general housekeeping must also be durable enough to clean rough surfaces and remain intact when used for scrubbing. Wipes used for clad decontamination do not need to absorb large amounts of liquid but they must be able to withstand neutron exposures, temperatures of up to several hundred degrees Celsius, and exposure to acid solutions followed by mild scrubbing. Finally wipes used for any purpose must resist chemical reactions with nitric acid that could cause issues for waste disposal such as energetic exothermic reactions or flammable gas build-up. The wipes selected for this study were ranked based on their usability (radiation tolerance, absorbency, integrity in nitric acid, and durability) as well as their chemical compatibility with nitric acid as demonstrated using several types of chemical analyses. Wipes were then ranked based on the combination of their usability and chemical compatibility scores.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation-resilient InAs quantum dot lasers

Displacement damage from particle radiation increases the threshold current of semiconductor lasers, impeding the deployment of photonic systems in harsh radiation environments. Replacing conventional quantum well (QW) gain regions with quantum dots (QDs) has been shown to suppress the radiation-induced increase in threshold current owing to three-dimensional carrier confinement, which effectively segregates charge carriers away from radiation-induced defects. However, radiation-induced change in threshold current is also affected by extrinsic design elements of a laser, such as photon lifetime, and therefore provides only a partial assessment of the radiation hardness. In this work, we advance the understanding of the radiation resiliency of InAs QD lasers by extracting the change in the nonradiative recombination rate after radiation exposure, which provides a more fundamental assessment of the intrinsic radiation hardness of InAs QD gain regions. We find that carriers that populate InAs QD states have a nonradiative recombination rate that is over an order-of-magnitude less sensitive to neutron radiation relative to carriers in InGaAsP QWs. InAs QD lasers must be designed such that carriers primarily occupy QD states, preventing carrier spillover into surrounding barrier layers to obtain the maximum benefit. Furthermore, we show that enhanced radiation hardness is observed in InAs QD lasers grown on both highly lattice-mismatched silicon substrates and native GaAs substrates, further broadening the appeal of InAs QD lasers as reliable light sources for photonic systems operating in harsh radiation environments.

47 OTHER INSTRUMENTATION↗

Handbook of X-Ray Astronomy

X-ray astronomy was born in the aftermath of World War II as military rockets were repurposed to lift radiation detectors above the atmosphere for a few minutes at a time. These early flights detected and studied X-ray emission from the Solar corona. The first sources beyond the Solar System were detected during a rocket flight in 1962 by a team headed by Riccardo Giaccom at American Science and Engineering, a company founded by physicists from MIT. The rocket used Geiger counters with a system designed to reduce non-X-ray backgrounds and collimators limiting the region of sky seen by the counters. As the rocket spun, the field of view (FOV) happened to pass over what was later found to be the brightest non-Solar X-ray source; later designated See X-1. It also detected a uniform background glow which could not be resolved into individual sources. A follow-up campaign using X-ray detectors with better spatial resolution and optical telescopes identified See X-1 as an interacting binary with a compact (neutron star) primary. This success led to further suborbital rocket flights by a number of groups. More X-ray binaries were discovered, as well as X-ray emission from supernova remnants, the radio galaxies M87 and Cygnus-A, and the Coma cluster. Detectors were improved and Geiger counters were replaced by proportional counters, which provided information about energy spectra of the sources. A constant challenge was determining precise positions of sources as only collimators were available.

Arnaud, Keith A.↗

Jet Propulsion Laboratory: Annual Report 2007

Many milestones are celebrated in the business of space exploration, but one of them that arrived this year has particular meaning for us. Half a century ago, on January 31, 1958, the Jet Propulsion Laboratory was responsible for creating America's first satellite, Explorer 1, and joined with the Army to launch it into orbit. That makes 2007 the 50th year we have been sending robotic craft from Earth to explore space. No other event before or since has had such a profound effect on JPL's basic identity, setting it on the path to become the world's leader in robotic solar system exploration. It is not lost on historians that Explorer 1, besides being America's first satellite, was also the first spacecraft from any country to deliver scientific results in its case, the discovery of the Van Allen Radiation Belts that surround Earth. Science, of course, has been the prime motivator for all the dozens of missions that we have lofted into space in the half-century since then. JPL has sent spacecraft to every planet in the solar system from Mercury to Neptune, some of them very sophisticated machines. But in one way or another, they all owe their heritage to the 31-pound bullet-shaped probe JPL shot into space in 1958. Although we have ranged far and wide across the solar system, we have a very strong contingent of satellites and instruments dedicated, like Explorer, to the environment of our home planet. JPL missions have been providing much of the data to establish the facts of global warming - most especially, the melting of ice sheets in Greenland and Antarctica. During the past year, JPL and our parent organization, the California Institute of Technology, have created a task force to focus the special capabilities of the Laboratory and campus on ways to better understand the physics of global change. While Earth is a chaotic and dynamic system capable of large natural variations, evidence is mounting that human activities are playing an increasingly important role. A central piece of this effort is a search for novel energy sources to replace fossil fuels, the combustion of which adds carbon dioxide to our atmosphere. All of this is supported by our worldwide Deep Space Network, which provides the communication link between spacecraft and the ground. In addition, missions are infused with technologies developed by researchers working on projects for non-NASA sponsors as well as on pure research.

Jet Propulsion Laboratory (JPL)↗

DEMONSTRATION OF THE NEXT-GENERATION TCAP HYDROGEN ISOTOPE SEPARATION PROCESS

The first generation of TCAP hydrogen isotope separation process has been in service for tritium separation at the Savannah River Site since 1994. To prepare for replacement, a next-generation TCAP process has been developed. This new process simplifies the column design and reduces the equipment requirements of the thermal cycling system. An experimental twelve-meter column was fabricated and installed in the laboratory to demonstrate its performance. This new design and its initial test results were presented at the 8th International Conference on Tritium Science and Technology and published in the proceedings. We have since completed the startup and demonstration the separation of protium and deuterium in the experimental unit. The unit has been operated for more than 200 cycles. A feed of 25% deuterium in protium was separated into two streams each better than 99.7% purity.

07 ISOTOPE AND RADIATION SOURCES↗

Design, Development and Operational Experience of Demonstration Facility for Cs-137 Source Pencil Production at Trombay - 13283

Radioactive waste management is a vital aspect of any nuclear program. The commercial feasibility of the nuclear program largely depends on the efficiency of the waste management techniques. One of such techniques is the separation of high yield radio-nuclides from the waste and making it suitable for medical and industrial applications. This will give societal benefit in addition to revenue generation. Co-60, the isotope presently being used for medical applications, needs frequent replacement because of its short half life. Cs-137, the major constituent of the nuclear waste, is a suitable substitute for Co-60 as a radioactive source because of its longer half life (28 years). Indian nuclear waste management program has given special emphasis on utilization of Cs-137 for such applications. In view of this a demonstration facility has been designed for vitrification of Cs-137 in borosilicate glass, cast in stainless steel pencils, to be used as source pencils of 300 Ci strength for blood irradiation. An induction heated metallic melter of suitable capacity has been custom designed for the application and employed for the Cs-137 pencil fabrication facility. This article describes various systems, design features, experiments and resulting modifications, observations and remote handling features necessary for the actual operation of such facility. The layout of the facility has been planned in such a way that the same can be adopted in a hot cell for commercial production of source pencils. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-181: Magnetic Resonance Image-Guided Radiation Therapy Workflow: Initial Clinical Experience

Purpose: The aims of this work are to describe the workflow and initial clinical experience treating patients with an MRI-guided radiotherapy (MRIGRT) system. Methods: Patient treatments with a novel MR-IGRT system started at our institution in mid-January. The system consists of an on-board 0.35-T MRI, with IMRT-capable delivery via doubly-focused MLCs on three {sup 60} Co heads. In addition to volumetric MR-imaging, real-time planar imaging is performed during treatment. So far, eleven patients started treatment (six finished), ranging from bladder to lung SBRT. While the system is capable of online adaptive radiotherapy and gating, a conventional workflow was used to start, consisting of volumetric imaging for patient setup using visible tumor, evaluation of tumor motion outside of PTV on cine images, and real-time imaging. Workflow times were collected and evaluated to increase efficiency and evaluate feasibility of adding the adaptive and gating features while maintaining a reasonable patient throughput. Results: For the first month, physicians attended every fraction to provide guidance on identifying the tumor and an acceptable level of positioning and anatomical deviation. Average total treatment times (including setup) were reduced from 55 to 45 min after physician presence was no longer required and the therapists had learned to align patients based on soft-tissue imaging. Presently, the source strengths were at half maximum (7.7K Ci each), therefore beam-on times will be reduced after source replacement. Current patient load is 10 per day, with increase to 25 anticipated in the near future. Conclusion: On-board, real-time MRI-guided RT has been incorporated into clinical use. Treatment times were kept to reasonable lengths while including volumetric imaging, previews of tumor movement, and physician evaluation. Workflow and timing is being continuously evaluated to increase efficiency. In near future, adaptive and gating capabilities of the system will be implemented.

60 APPLIED LIFE SCIENCES↗

System and technoeconomic analysis of solar thermochemical hydrogen production

Hydrogen is a promising energy carrier that can be obtained from various feedstocks using renewable energy sources. Direct solar thermochemical hydrogen (STCH) production by water splitting can utilize the full spectrum of solar radiation and has the potential to achieve high solar energy conversion efficiencies. Currently STCH research areas focus on material discovery. This paper evaluates the performance of various STCH materials in the context of a system platform to assess techno-economic benefits and gaps in the path to STCH scale-up. Additionally, to analyze the hydrogen production cost, a concentrating solar thermal (CST) system is introduced as a platform for integrating STCH materials and accommodating generalized thermochemical processes. The thermochemical process is based on a two-step STCH cycle using metal oxide that consists of a high temperature step for metal oxide reduction, followed by an oxidation step for water splitting at a lower temperature. A preferred configuration is to have the high temperature step occurring in a directly irradiated solar receiver reactor. To this end, we conceptualized a receiver design and associated solar field layout and investigated STCH operational boundaries, component costs and sensitivity parameters on the $2/kgH 2 goal of hydrogen production. The study explored system-related variables and factors associated with scaling up. The CST platform allows more comprehensive studies that encompass aspects of STCH materials and systems such as cost, hydrogen productivity and replacement frequency, alongside other system components like heliostat field, tower, and potential receiver costs.

08 HYDROGEN↗

Coherent Synchrotron-Based Micro-Imaging Employed for Studies of Micro-Gap Formation in Dental Implants

Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium-based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro-bacterial leakage, especially when two-piece concepts are used. Synchrotron-based hard x-ray radiography, unlike conventional laboratory radiography, allows high spatial resolution in combination with high contrast even when micro-sized features in such highly attenuating objects are visualized. Therefore, micro-gap formation at interfaces in two-piece dental implants with the sample under different mechanical loads can be studied. We show the existence of micro-gaps in implants with conical connections and study the mechanical behavior of the mating zone of conical implants during loading. The micro-gap is a potential source of implant failure, i.e., bacterial leakage, which can be a stimulus for an inflammatory process.

60 APPLIED LIFE SCIENCES↗

A 5 per cent measurement of the Hubble–Lemaître constant from Type II supernovae

ABSTRACT The most stringent local measurement of the Hubble–Lemaître constant from Cepheid-calibrated Type Ia supernovae (SNe Ia) differs from the value inferred via the cosmic microwave background radiation (Planck+ΛCDM) by ∼5σ. This so-called Hubble tension has been confirmed by other independent methods, and thus does not appear to be a possible consequence of systematic errors. Here, we continue upon our prior work of using Type II supernovae to provide another, largely independent method to measure the Hubble–Lemaître constant. From 13 SNe II with geometric, Cepheid, or tip of the red giant branch (TRGB) host-galaxy distance measurements, we derive H$_0= 75.4^{+3.8}_{-3.7}$ km s−1 Mpc−1 (statistical errors only), consistent with the local measurement but in disagreement by ∼2.0σ with the Planck+ΛCDM value. Using only Cepheids (N = 7), we find H$_0 = 77.6^{+5.2}_{-4.8}$ km s−1 Mpc−1, while using only TRGB (N = 5), we derive H$_0 = 73.1^{+5.7}_{-5.3}$ km s−1 Mpc−1. Via 13 variants of our data set, we derive a systematic uncertainty estimate of 1.5 km s−1 Mpc−1. The median value derived from these variants differs by just 0.3 km s−1 Mpc−1 from that produced by our fiducial model. Because we only replace SNe Ia with SNe II – and we do not find statistically significant difference between the Cepheid and TRGB H0 measurements – our work reveals no indication that SNe Ia or Cepheids could be the sources of the ‘H0 tension.’ We caution, however, that our conclusions rest upon a modest calibrator sample; as this sample grows in the future, our results should be verified.

79 ASTRONOMY AND ASTROPHYSICS↗

Criteria Considered in Selecting Feed Items for Americium-241 Oxide Production Operations

The analysis in this document serves the purpose of defining a number of attributes in selection of feed items to be utilized in recovery/recycle of Pu and also production operations of 241 AmO 2 material intended to meet specification requirements. This document was written in response to a specific request on the part of the 2014 annual program review which took place over the dates of October 28-29, 2014. A number of feed attributes are noted including: (1) Non-interference with existing Pu recovery operations; (2) Content of sufficient 241 Am to allow process efficiency in recovery operations; (3) Absence of indications that 243 Am might be mixed in with the Pu/ 241 Am material; (4) Absence of indications that Cm might be mixed in with the Pu/ 241 Am material; (5) Absence of indications of other chemical elements that would present difficulty in chemical separation from 241 Am; (6) Feed material not expected to present difficulty in dissolution; (7) Dose issues; (8) Process efficiency; (9) Size; (10) Hazard associated with items and package configuration in the vault; (11) Within existing NEPA documentation. The analysis in this document provides a baseline of attributes considered for feed materials, but does not presume to replace the need for technical expertise and judgment on the part of individuals responsible for selecting the material feed to be processed. This document is not comprehensive as regards all attributes that could prove to be important. The value of placing a formal QA hold point on accepting feed items versus more informal management of feed items is discussed in the summation of this analysis. The existing planned QA hold points on 241 AmO 2 products produced and packaged may be adequate as the entire project is based on QA of the product rather than QA of the process. The probability of introduction of items that would inherently cause the 241 AmO 2 products produced to be outside of specification requirements appears to be rather small.

07 ISOTOPE AND RADIATION SOURCES↗

Noncontact Flow Rate Using Laser Ultrasonics

Several types of advanced nuclear reactors are cooled with high-temperature liquid metal or molten salt flows. There is a critical need to measure flow velocity in flow channels for test purposes, and eventually in operational reactors. In conventional ultrasonic flow sensors, ultrasonic waves traveling in both the upstream and downstream directions are generated and detected by transducers that must contact the flow channels. A shift in the frequency or transit time between the two ultrasonic waves is measured to determine flow velocity. We describe here an initial effort to apply that sensing concept when the contact transducers are replaced by laser-based generation and detection instrumentation. This noncontact sensing avoids many practical problems associated with contact transducers when implemented on flow channels at high temperature. Laser-based flow monitoring can also be applied to hot-process piping in the geothermal energy, chemical-processing and petroleum-refining industries. Our effort has included theoretical simulation of noncontact laser-based flow monitoring, indicating capability of measuring flow velocities relevant to reactor cooling. It also included a room-temperature experimental demonstration using water as the flow liquid, and indicating capability of measuring flow velocity at a responsivity roughly consistent with simulation predictions. Plans were made for an experimental demonstration at Oregon State University using liquid metal at 110 degrees C.

02 PETROLEUM↗

Electron contamination modeling and reduction in a 1 T open bore inline MRI-linac system

Purpose: A potential side effect of inline MRI-linac systems is electron contamination focusing causing a high skin dose. In this work, the authors reexamine this prediction for an open bore 1 T MRI system being constructed for the Australian MRI-Linac Program. The efficiency of an electron contamination deflector (ECD) in purging electron contamination from the linac head is modeled, as well as the impact of a helium gas region between the deflector and phantom surface for lowering the amount of air-generated contamination. Methods: Magnetic modeling of the 1 T MRI was used to generate 3D magnetic field maps both with and without the presence of an ECD located immediately below the MLC’s. Forty-seven different ECD designs were modeled and for each the magnetic field map was imported into Geant4 Monte Carlo simulations including the linac head, ECD, and a 30 × 30 × 30 cm{sup 3} water phantom located at isocenter. For the first generation system, the x-ray source to isocenter distance (SID) will be 160 cm, resulting in an 81.2 cm long air gap from the base of the ECD to the phantom surface. The first 71.2 cm was modeled as air or helium gas, with the latter encased between two windows of 50 μm thick high density polyethlyene. 2D skin doses (at 70 μm depth) were calculated across the phantom surface at 1 × 1 mm{sup 2} resolution for 6 MV beams of field size of 5 × 5, 10 × 10, and 20 × 20 cm{sup 2}. Results: The skin dose was predicted to be of similar magnitude as the generic systems modeled in previous work, 230% to 1400% ofD {sub max} for 5 × 5 to 20 × 20 cm{sup 2}, respectively. Inclusion of the ECD introduced a nonuniformity to the MRI imaging field that ranged from ∼20 to ∼140 ppm while the net force acting on the ECD ranged from ∼151 N to ∼1773 N. Various ECD designs were 100% efficient at purging the electron contamination into the ECD magnet banks; however, a small percentage were scattered back into the beam and continued to the phantom surface. Replacing a large portion of the extended air-column between the ECD and phantom surface with helium gas is a key element as it significantly minimized the air-generated contamination. When using an optimal ECD and helium gas region, the 70 μm skin dose is predicted to increase moderately inside a small hot spot over that of the case with no magnetic field present for the jaw defined square beams examined here. These increases include from 12% to 40% of D {sub max} for 5 × 5 cm{sup 2}, 18% to 55% of D {sub max} for 10 × 10 cm{sup 2}, and from 23% to 65% of D {sub max} for 20 × 20 cm{sup 2}. Conclusions: Coupling an efficient ECD and helium gas region below the MLCs in the 160 cm isocenter MRI-linac system is predicted to ameliorate the impact electron contamination focusing has on skin dose increases. An ECD is practical as its impact on the MRI imaging distortion is correctable, and the mechanical forces acting on it manageable from an engineering point of view.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential dose distributions at proposed surface radioactvity clearance levels resulting from occupational scenarios.

The purpose of this report is to evaluate the potential dose distribution resulting from surface radioactivity, using occupational radiation exposure scenarios. The surface radioactivity clearance values considered in this analysis may ultimately replace those currently specified in the U.S. Department of Energy (DOE) requirements and guidance for radiological protection of workers, the public and the environment. The surface contamination values apply to radioactive contamination deposited on a surface (i.e., not incorporated into the interior of the material). For these calculations, the dose coefficients for intake of radionuclides were taken from ICRP Publication 68 (ICRP 1994), and external exposure dose coefficients were taken from the compact disc (CD) that accompanied Federal Guidance Report (FGR) 13 (Eckerman et al. 1999). The ICRP Publication 68 dose coefficients were based on ICRP Publication 60 (ICRP 1990) and were used specifically for worker dose calculations. The calculated dose in this analysis is the 'effective dose' (ED), rather than the 'effective dose equivalent' (EDE).

07 ISOTOPE AND RADIATION SOURCES↗

Recent Shuttle Post Flight MMOD Inspection Highlights

Post flight inspections on the Space Shuttle Atlantis conducted after the STS-11.5 mission revealed a 0.11 inch (2.8 mm) hole in the outer face sheet of the starboard payload bay door radiator panel #4. The payload bay door radiators in this region are 0.5 inch (12.7 mm) thick aluminum honeycomb with 0.011 in (0.279 mm) thick aluminum face sheets topped with 0.005 in (0.127 mm) silver-Teflon tape. Inner face sheet damage included a 0.267 in (6.78 mm) long through crack with measureable deformation in the area of 0.2 in (5.1 mm). There was also a 0.031 in (0.787 nun) diameter hole in the rear face sheet. A large approximately l in (25 mm) diameter region of honeycomb was also destroyed. Since the radiators are located on the inside of the shuttle payload bay doors which are closed during ascent and reentry, the damage could only have occurred during the on-orbit portion of the mission. During the August 2007 STS-118 mission to the International Space Station, a micro-meteoroid or orbital debris (MMOD) particle impacted and completely penetrated one of shuttle Endeavour's radiator panels and the underlying thermal control system (TCS) blanket, leaving deposits on (but no damage to) the payload bay door. While it is not unusual for shuttle orbiters to be impacted by small MMOD particles, the damage from this impact is larger than any previously seen on the shuttle radiator panels. One of the largest impacts ever observed on a crew module window occurred during the November 2008 STS-126 mission to the International Space Station. Damage to the window was documented by the crew on orbit. Post flight inspection revealed a 0.4 in (10.8 mm) crater in the window pane, with a depth of 0.03 in (0.76 mm). The window pane was replaced due to the damage caused by this impact. Analysis performed on residue contained in dental mold impressions taken of the site indicated that a meteoroid particle produced this large damage site. The post flight inspection after the subsequent mission, STS-119 in March of 2009, produced a large MMOD impact feature in a wing leading edge reinforced carbon-carbon panel. The crater measured 0.18 in (4.5 nun) in diameter and was nearly 0.037 in (0.93 nun) deep. The thickness of the silicon carbide coating that protects the carbon substrate is nominally 0.02 in (0.5 nun) to 0.04 in (1 mm), making this a significant impact into the RCC. The damage occurred on the upper surface of the panel, which experiences lower heat loads on re-entry. This poster will document the data collected from the impact sites and will include results of the Scanning Electron Microscope/Energy Dispersive X-ray (SEM/EDX) analysis. Evidence will be presented that suggests a source of the impacts.

Hyed, James L.↗