Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Infrared Scanning

United Scanning Technologies, Inc.'s Infrared thermography is a relatively new noncontact, nondestructive inspection and testing tool which makes temperatures visible to the human eye. Infrared scanning devices produce images that show, by color or black and white shading differences, heat losses through damaged or inadequately insulated walls or roofs. The MISS Aeroscan services are designed to take the guesswork out of industrial roof maintenance and provide companies big savings by identifying the location of moisture damage from roof leaks, effectively targeting maintenance attention.

Source record↗

Home Insulation With the Stroke of a Brush

Hy-Tech Thermal Solutions, LLC, of Melbourne, Florida, is producing a very complex blend of ceramic vacuum-filled refractory products designed to minimize the path of hot air transfer through ceilings, walls, and roofs. The insulating ceramic technology blocks the transfer of heat outward when applied to paint on interior walls and ceilings, and prevents the transfer of heat inward when used to paint exterior walls and roofs, effectively providing year-round comfort in the home. As a manufacturer and marketer of thermal solutions for residential, commercial, and industrial applications, Hy-Tech Thermal Solutions attributes its success to the high performance insulating ceramic microsphere originally developed from NASA thermal research at Ames Research Center. Shaped like a hollow ball so small that it looks as if it is a single grain of flour to the naked eye (slightly thicker than a human hair), the microsphere is noncombustible and fairly chemical-resistant, and has a wall thickness about 1/10 of the sphere diameter, a compressive strength of about 4,000 pounds per square inch, and a softening point of about 1,800 C. Hy-Tech Thermal Solutions improved upon these properties by removing all of the gas inside and creating a vacuum. In effect, a 'mini thermos bottle' is produced, acting as a barrier to heat by reflecting it away from the protected surface. When these microspheres are combined with other materials, they enhance the thermal resistance of those materials. In bulk, the tiny ceramic 'beads' have the appearance of a fine talcum powder. Their inert, nontoxic properties allow them to mix easily into any type of paint, coating, adhesive, masonry, or drywall finish. Additionally, their roundness causes them to behave like ball bearings, rolling upon each other, and letting the coatings flow smoothly. When applied like paint to a wall or roof, the microsphere coating shrinks down tight and creates a dense film of the vacuum cells. The resulting ceramic layer improves fire resistance, protects from ultraviolet rays, repels insects such as termites, and shields from the destructive forces of nature.

Source record↗

Solar Energy Demonstrations

Solar energy furnishes all of the heating and hot water needs, plus 80 percent of the air conditioning, for the two-story Reedy Creek building. A unique feature of this installation is that the 16 semi-cylindrical solar collectors (center photo on opposite page with closeup of a single collector below it) are not mounted atop the roof as is customary, they actually are the roof. This arrangement eliminates the usual trusses, corrugated decking and insulating concrete in roof construction; that, in turn, reduces overall building costs and makes the solar installation more attractive economically. The Reedy Creek collectors were designed and manufactured by AAI Corporation of Baltimore, Maryland.

Source record↗

Unitary Plan Wind Tunnel Tests of Cook Technological Center Parachutes in the Wake of a Conical-Nosed Cylindrical Body Having a Base Diameter of 2.375-Inches (Part 5 of 6)

The film depicts two tests of a flat roof, conical inlet canopy parachute. The first test is a series of wind tunnel trials with a flat circular ribbon roof of 22 percent porosity. The second test is a single series of wind tunnel trials with a flat circular ribbon roof of 25 percent porosity. Variables for both trials include Mach number, dynamic pressure, longitudinal separation distances (x/d), and drag coefficient C(sub d).

Source record↗

Development and Testing of the Glenn Research Center Visitor's Center Grid-Tied Photovoltaic Power System

The NASA Glenn Research Center (GRC) has developed, installed, and tested a 12 kW DC grid-tied photovoltaic (PV) power system at the GRC Visitor s Center. This system utilizes a unique ballast type roof mount for installing the photovoltaic panels on the roof of the Visitor s Center with no alterations or penetrations to the roof. The PV system has generated in excess of 15000 kWh since operation commenced in August 2008. The PV system is providing power to the GRC grid for use by all. Operation of the GRC Visitor s Center PV system has been completely trouble free. A grid-tied PV power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. The project transfers space technology to terrestrial use via nontraditional partners. GRC personnel glean valuable experience with PV power systems that are directly applicable to various space power systems, and provides valuable space program test data. PV power systems help to reduce harmful emissions and reduce the Nation s dependence on fossil fuels. Power generated by the PV system reduces the GRC utility demand, and the surplus power aids the community. Present global energy concerns reinforce the need for the development of alternative energy systems. Modern PV panels are readily available, reliable, efficient, and economical with a life expectancy of at least 25 years. Modern electronics has been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy of at least 25 years. Based upon the success of the GRC Visitor s Center PV system, additional PV power system expansion at GRC is under consideration. The GRC Visitor s Center grid-tied PV power system was successfully designed and developed which served to validate the basic principles described, and the theoretical work that was performed. The report concludes that grid-tied photovoltaic power systems are reliable, maintenance free, long life power systems, and are of significant value to NASA and the community.

Eichenberg, Dennis J.↗

Simulating the Impact Response of Composite Airframe Components

In 2010, NASA Langley Research Center obtained residual hardware from the US Army's Survivable Affordable Repairable Airframe Program (SARAP). The hardware consisted of a composite fuselage section that was representative of the center section of a Black Hawk helicopter. The section was fabricated by Sikorsky Aircraft Corporation and designated the Test Validation Article (TVA). The TVA was subjected to a vertical drop test in 2008 to evaluate a tilting roof concept to limit the intrusion of overhead mass items, such as the rotor transmission, into the fuselage cabin. As a result of the 2008 test, damage to the hardware was limited primarily to the roof. Consequently, when the post-test article was obtained in 2010, the roof area was removed and the remaining structure was cut into six different types of test specimens including: (1) tension and compression coupons for material property characterization, (2) I-beam sections, (3) T-sections, (4) cruciform sections, (5) a large subfloor section, and (6) a forward framed fuselage section. In 2011, NASA and Sikorsky entered into a cooperative research agreement to study the impact responses of composite airframe structures and to evaluate the capabilities of the explicit transient dynamic finite element code, LS-DYNA®, to simulate these responses including damage initiation and progressive failure. Finite element models of the composite specimens were developed and impact simulations were performed. The properties of the composite material were represented using both a progressive in-plane damage model (Mat 54) and a continuum damage mechanics model (Mat 58) in LS-DYNA. This paper provides test-analysis comparisons of time history responses and the location and type of damage for representative I-beam, T-section, and cruciform section components.

Jackson, Karen E.↗

Simulating the Impact Response of Full-Scale Composite Airframe Structures

NASA Langley Research Center obtained a composite helicopter cabin structure in 2010 from the US Army's Survivable Affordable Repairable Airframe Program (SARAP) that was fabricated by Sikorsky Aircraft Corporation. The cabin had been subjected to a vertical drop test in 2008 to evaluate a tilting roof concept to limit the intrusion of overhead masses into the fuselage cabin. Damage to the cabin test article was limited primarily to the roof. Consequently, the roof area was removed and the remaining structure was cut into test specimens including a large subfloor section and a forward framed fuselage section. In 2011, NASA and Sikorsky entered into a cooperative research agreement to study the impact responses of composite airframe structures and to evaluate the capabilities of the explicit transient dynamic finite element code, LS-DYNA®, to simulate these responses including damage initiation and progressive failure. Most of the test articles were manufactured of graphite unidirectional tape composite with a thermoplastic resin system. However, the framed fuselage section was constructed primarily of a plain weave graphite fabric material with a thermoset resin system. Test data were collected from accelerometers and full-field photogrammetry. The focus of this paper will be to document impact testing and simulation results for the longitudinal impact of the subfloor section and the vertical drop test of the forward framed fuselage section.

Fasanella, Edwin L.↗

Acoustically Tailored Composite Rotorcraft Fuselage Panels

A rotorcraft roof sandwich panel has been redesigned to optimize sound power transmission loss (TL) and minimize structure-borne sound for frequencies between 1 and 4 kHz where gear meshing noise from the transmission has the most impact on speech intelligibility. The roof section, framed by a grid of ribs, was originally constructed of a single honeycomb core/composite face sheet panel. The original panel has coincidence frequencies near 700 Hz, leading to poor TL across the frequency range of 1 to 4 kHz. To quiet the panel, the cross section was split into two thinner sandwich subpanels separated by an air gap. The air gap was sized to target the fundamental mass-spring-mass resonance of the double panel system to less than 500 Hz. The panels were designed to withstand structural loading from normal rotorcraft operation, as well as 'man-on-the-roof' static loads experienced during maintenance operations. Thin layers of VHB 9469 viscoelastomer from 3M were also included in the face sheet ply layups, increasing panel damping loss factors from about 0.01 to 0.05. Measurements in the NASA SALT facility show the optimized panel provides 6-11 dB of acoustic transmission loss improvement, and 6-15 dB of structure-borne sound reduction at critical rotorcraft transmission tonal frequencies. Analytic panel TL theory simulates the measured performance quite well. Detailed finite element/boundary element modeling of the baseline panel simulates TL slightly more accurately, and also simulates structure-borne sound well.

Hambric, Stephen↗

Guatemala and Panama Urban Development: Evaluating the Effects of Urban Expansion on Social and Environmental Vulnerability in Guatemala and Panama

Central America is experiencing rapid and unregulated urban expansion, which is contributing to an increase in socioeconomic and environmental risks including inequities in infrastructure and housing accessibility, biodiversity loss, vulnerability to natural disasters, and negative health outcomes. NASA DEVELOP, in partnership with NASA SERVIR, Sistema de la Integración Centroamericana (SICA), Secretariat of Central American Social Integration (SISCA), Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ), and Centro de Coordinación para la Prevención de los Desastres en América Central y República Dominicana (CEPRENEDAC), examined changes in urban extent, characterized roofing material type, and analyzed vulnerability within urban areas in two Central American cities, Guatemala City and Panama City. The team used land cover imagery from Landsat 5 Thematic Mapper (TM), Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI), and Landsat 9 OLI-2 to map urban extent, and surface reflectance data from Maxar Worldview to identify roofing material types. Socioeconomic and environmental data were used to assess vulnerability. Results depict how the two cities have expanded from 2000 to present day and highlight areas of greatest vulnerability within each urban area. The supervised classification of roofing materials performed well but could be improved with a few enhancements. Findings can help partner organizations improve monitoring of urbanization and inform their planning and decision-making while prioritizing disaster prevention, public health, and environmental integrity. Additionally, these case studies can be used to inform future, similar work elsewhere in Central America to aid in understanding urbanization and its associated challenges.

Jennifer Ruiz↗

Best Practices Case Study: Green Coast Enterprises - Project Home Again, New Orleans, LA

Case study about Green Coast Enterprises, who received design assistance and analysis from Building America team Building Science Corporation to build 100 homes for New Orleans families displaced by Hurricane Katrina. The homes incorporate a host of weather-resistant techniques: pier foundations, all borate pressure-treated lumber; hurricane strapping; moisture-resistant closed-cell spray foam insulation under the subfloor, in walls, and under the roof line to seal out moisture-laden air and glue the structure together to resist high winds; roof sheathing seams sealed with butyl-adhesive flashing tape; and a fully adhered roofing membrane over eaves and gable ends.

Building America↗

Visual-SOLAR: Modeling and Visualization of Solar Radiation Potential on Individual Building Rooftops

We have developed a modeling framework for estimating solar radiation potentials on individual building rooftops that is suitable for utility-scale applications as well as building-specific applications. The framework uses light detection and ranging (LIDAR) data at approximately 1-meter horizontal resolution and 0.3-meter vertical resolution as input for modeling a large number of buildings quickly. One of the strengths of this framework is the ability to parallelize its implementation. Furthermore, the framework accounts for building specific characteristics, such as roof slope, roof aspect, and shadowing effects, that are critical to roof-mounted photovoltaic system. The resulting data has helped us to identify the so-called "solar panel sweet spots" on individual building rooftops and obtain accurate statistics of the variation in solar radiation as a function of time of year and geographical location.

Source record↗

Rooftop Solar Photovoltaic Technical Potential in the United States

How much energy could we generate if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models -- one for small buildings and one for medium and large buildings -- and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Validation of Aurora Solar Inc.'s Envision Software Capabilities

As part of the Department of Energy's SunShot Incubator program, Aurora has worked to develop a web-based application that quickly and precisely calculates the solar potential of a building's roof. The Aurora Envision platform utilizes Google StreetView photos as a basis for measuring roof slope and linear measurements of determining the proper inputs into an eventual shade model. The stated accuracy by Aurora Solar to be tested is lengths within 1.5 feet and slope measurements within 5 degrees. The National Renewable Energy Laboratory (NREL), in partnership with Aurora and supported by the U.S. Department of Energy's (DOE) SunShot Technology to Market Incubator program, independently verified the accuracy of Aurora's Envision measurements on 15 unique roofs throughout the Denver, Colorado region. NREL measured 60 measurements: 27 of 28 slope measurements were within the stated accuracy, 32 of 32 distance measurements were within the stated accuracy.

14 SOLAR ENERGY↗

Installation Demonstration and Performance Evaluation of Composite Foam-Vacuum Insulation Boards in an Occupied Building

This article summarizes the installation demonstration of R25 composite insulation boards containing polyisocyanurate (PIR) foam-encapsulated modified atmosphere insulation (MAI) panels. The R25 boards can achieve a thermal resistance of 25 hr-ft2-°F/Btu within 2 inches of thickness (or R12/inch). MAI represents a lower-cost version of vacuum insulation panels (VIPs). The R25 composite boards were developed by the project team consisting of a foam insulation manufacturer, a vacuum insulation manufacturer and a research organization. R25 boards were used to retrofit a section of a low-slope roof. For comparison, adjacent roof sections were retrofitted with two layers of 2 inch regular PIR foam boardsThe retrofit installation was performed by professional roofing contractors and some weight-related issues were identified. In a follow-on discussion within the project team, mitigation methods were proposed. The long-term thermal performance of the R25 and regular PIR foam boards are being monitored using temperature and heat flow sensors installed above and below the insulation layers. Preliminary data analysis results are presented here.

Biswas, Kaushik↗

Parcel-Scale Assessment of Rooftop Solar Technical Potential

Understanding the potential for rooftop solar and other distributed energy resources (DERs) to contribute to power system planning is increasingly relevant for cities, utilities, and other planning entities. Such planning efforts typically require an estimate of technical potential, or the feasible technology potential independent of economic considerations. Currently, best-in-class rooftop solar technical potential methods use Light Detection and Ranging (LiDAR) data which can identify each roof plane tilt, azimuth, and unshaded area. However, LiDAR data is not universally available and, even when available, obtaining and processing this data can be expensive. In contrast, parcel-level data is easy to use and widely available as it is generated by jurisdictions to levy property taxes. Such data universally reports building footprint area, which is highly correlated with roof area suitable (developable) for rooftop solar. Moreover, parcel data identifies building end-use, tenure, and other building characteristics not provided by LiDAR. To explore the feasibility of using parcel data to assess technical potential more broadly, we compare estimates using parcel data in Orlando, Florida (HIFLD 2020) to those generated using LiDAR data (Koebrich et al. 2021). We find that the parcel-based method results in accurate technical potential estimates at a block and city-scale, though only after accounting for shading and other factors that derate developable roof area. The results of this study demonstrate a scalable, low-effort approach to assess rooftop solar technical potential for every city and community in the U.S.

census blocks↗

Contaminant Migration Modeling to Support the In Situ Decommissioning of Hardened Nuclear Facilities - 20215

The decommissioning of hardened nuclear facilities provides a unique challenge in balancing current worker dose with exposure to future receptors and media. In situ decommissioning (ISD) is a cost-effective and safe option for the closure of such facilities but requires a detailed understanding of the threat that radioactive and hazardous constituents remaining in the facilities pose to groundwater and surrounding surface water. The Savannah River Site (SRS) extensively employs contaminant migration models within the decommissioning process to develop site-specific removal, grouting, and monitoring strategies in support of safe and effective final end states of nuclear facilities. This work discusses the use of contaminant migration modeling in the ISD process at SRS, including specific examples from the closure of P-Reactor and R-Reactor, Building 235-F, F-Canyon and F/H Laboratory Complex. Migration models developed during the closure of P-Reactor and R-Reactor were divided into four source areas: the reactor vessel, the process area, the disassembly basin, and the purification wing. Each source area was assigned a specific inventory and migration pathway and was then subject to varying hypothetical removal, capping, and grouting schemes. Modeling indicated that groundwater Maximum Concentration Limits (MCLs) might be exceeded if no action was taken for eleven and ten constituents of concern (COCs) at P-Reactor and R-Reactor, respectively. These exceedances could occur in as few as 200 to 500 years. Alternatively, the migration modeling demonstrated that the selected ISD actions reduced contaminant mobility which allowed for significant radioactive decay and resulted in fewer predicted exceedances of groundwater MCLs (five COCs for P-Reactor; eight COCs for R-Reactor). In response to the modeling results for P-Reactor and R-Reactor, effectiveness monitoring programs were developed to target contaminants, specific to each reactor, that may migrate to groundwater. Contaminant migration modeling also revealed that roof collapse was a large factor in the release of COCs to the environment, giving rise to roof improvements, and an inspection and vegetation control program to ensure roof stability over time. Contaminant migration modeling is also aiding in the closure planning for hardened facilities in F Area. Building 235-F housed the Actinide Billet Line, which produced Np-237 billets for irradiation in SRS reactors, and the Plutonium Fuel Form (PuFF) facility that produced Pu-238 heat sources for the space program. As a result of these missions, areas within Building 235-F contain considerable residual amounts of both Pu-238 and Np-237. Contaminant migration modeling of Building 235-F was originally performed in 2012 to identify the feasibility of ISD and the amount of radioactive material removal required to prevent the exceedance of groundwater MCLs. The original model indicated that a 60% reduction in the PuFF facility Pu-238 inventory could keep groundwater concentrations below standards, while Np-237 did not pose a threat to groundwater. However, updates to the model with an emphasis on source impact pathways revealed that, due to the orientation of the source areas relative to groundwater flow, no amount of reasonable removal of Pu-238 would keep groundwater concentrations below MCLs and that Np-237 could be a large contributor to localized MCL exceedances. With this insight, the refined 2019 model is being used to assist in the development of grouting plans specific to each facility source area, where bentonite may be utilized to slow the migration of Pu-238 and its daughter products from the PuFF facility and a reducing grout may decrease Np-237 transport by ensuring the nuclide remains in the less mobile +IV oxidation state. The beginning phases of contaminant migration modeling are underway for F-Canyon and associated facilities using lessons learned from the Reactors and Building 235-F. A contaminant migration pathway, similar to the pathway used for the reactor vessels, is being developed for the hot and warm canyons. The F-Canyon inventories are being spatially refined to identify specific and localized source zones, comparable to Building 235-F, that may impact groundwater. Contaminant migration modeling provides vital input within the ISD process, from facility investigation to post closure effectiveness monitoring, making it a valuable tool in the development of safe and effective end states for hardened nuclear facilities at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring the Meteorological Impacts of Surface and Rooftop Heat Mitigation Strategies Over a Tropical City

Different heat mitigation technologies have been developed to improve the thermal environment in cities. However, the regional impacts of such technologies, especially in the context of a tropical city, remain unclear. The deployment of heat mitigation technologies at city-scale can change the radiation balance, advective flow, and energy balance between urban areas and the overlying atmosphere. We used the mesoscale Weather Research and Forecasting model coupled with a physically based single-layer urban canopy model to assess the impacts of five different heat mitigation technologies on surface energy balance, standard surface meteorological fields, and planetary boundary layer (PBL) dynamics for premonsoon typical hot summer days over a tropical coastal city in the month of April in 2018, 2019, and 2020. Results indicate that the regional impacts of cool materials (CMs), super-cool broadband radiative coolers, green roofs (GRs), vegetation fraction change, and a combination of CMs and GRs (i.e., “Cool city (CC)”) on the lower atmosphere are different at diurnal scale. Results showed that super-cool materials have the maximum potential of ambient temperature reduction of 1.6°C during peak hour (14:00 LT) compared to other technologies in the study. During the daytime hours, the PBL height was considerably lower than the reference scenario with no implementation of strategies by 700 m for super-cool materials and 500 m for both CMs and CC cases; however, the green roofing system underwent nominal changes over the urban area. During the nighttime hours, the PBL height increased by CMs and the CC strategies compared to the reference scenario, but minimal changes were evident for super-cool materials. The changes of temperature on the vertical profile of the heat mitigation implemented city reveal a stable PBL over the urban domain and a reduction of the vertical mixing associated with a pollution dome. This would lead to crossover phenomena above the PBL due to the decrease in vertical wind speed. Therefore, assessing the coupled regional impact of urban heat mitigation over the lower atmosphere at city-scale is urgent for sustainable urban planning.

54 ENVIRONMENTAL SCIENCES↗

How can we combine urban cooling strategies to effectively cool cities over the entire diurnal cycle?

The urban heat island effect generally peaks in the night/evening hours and, in some cases, an urban cool island effect during daytime has been reported. These patterns are observed mainly because of the widespread use of impervious and thermally massive materials (like concrete and asphalt) in the built environment and their ability to store energy during the daytime and release it at night. Unfortunately, most urban cooling strategies, such as cool (white), green, and blue spaces, provide better thermal performance during the daytime than at night. Hence, such solutions are not ideal for nighttime heat mitigation. In this study, we investigate the effect of the thermal storage capacity of existing buildings on nighttime urban air temperature for a hot arid city—Phoenix, and a hot humid city—Atlanta. The study uses regional scale atmospheric modeling to compare the nighttime urban cooling capability of thermally light buildings (Cross-laminated timber buildings in this case) with concrete buildings. The results show that the adoption of thermally light buildings reduce nighttime air temperatures, and slightly increases daytime air temperatures. On the other hand, cool roof adaption could reduce urban air temperature significantly during the daytime and slightly at night. Therefore, together with cool roofs, thermally light buildings may be able to cool the surrounding air by an average of about 1°C throughout the diurnal cycle, providing thermal comfort and reducing cooling demand during all hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗