Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REMOVAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Removal of deuterium retained in boron powder by oxygen or high-temperature bakeout

Fuel retention in dust accumulated in fusion devices is a potential operational hazard. Boronization is one of the leading wall-conditioning candidates for future fusion devices. Fuel retention characteristics of boron dust must be studied to accurately understand the potential hazards of boron dust in fusion devices. We evaluated the retention of deuterium (D) in commercially available boron powder as a proxy for tritium retention in boron dust. Diffuse reflectance infrared Fourier transform spectroscopy revealed that boron powder between 300 and 500 K exposed to neutral hydrogen (H 2 ) gas retains H via B-H bonding. We utilized D 2 exposures of 17,400 L on the boron powder, which led to retention on the order of 0.5 g D per 100 kg B or 1.2 g D per m 2 B, as estimated from temperature programmed desorption measurements. We evaluated how powder bakeouts under ultra-high vacuum (UHV), or in an oxygen (O 2 ) or H 2 gas backfilled environment can remove the retained fuel. Bakeouts below 523 K under UHV exhibited poor D removal, promoting recapture of D 2 present as background gas in the chamber. Higher temperature bakeouts led to the removal of over 80% of the retained D within 3 days (623 K) or 1 h (723 K). Bakeouts at 423 K under an O 2 gas environment removed ∼150% more retained D from the boron powder, when compared to bakeouts conducted under UHV. These results suggest that efficient fuel removal from boron dust can be achieved by high-temperature bakeout (>623 K) or by bakeouts at lower temperature (423 K) under an O 2 environment.

Bakeout↗

Fabrication and properties of an immobilized P25TiO{sub 2}-montmorillonite bilayer system for the synergistic photocatalytic–adsorption removal of methylene blue

Highlights: • P25TiO{sub 2} and montmorillonite was integrated via an immobilized bilayer approach. • Synergistic dual photocatalytic–adsorptive removal of MB was observed. • Removal rate of MB was 4 times better than P25TiO{sub 2} alone. • Excellent reusability with sustainable rate of removal of MB. • Treated water can be discharged directly without the need of a filtration system. - Abstract: A bilayer immobilized system consisting of a mesoporous montmorillonite (MT) as the sublayer and a porous P25TiO{sub 2} toplayer was successfully fabricated on a glass plate. The MT sublayer was immobilized onto the glass plate by means of a glutaraldehyde (GLA) cross-linked poly (vinyl) alcohol (PVA) as the binder (MT-PVAB) while the top layer constituted of nano-sized TiO{sub 2} bound by the ENR-PVC polymer blends (P-25TiO{sub 2}). The incorporation of MT-PVAB to P-25TiO{sub 2} caused a reduction in the band gap energy while PLS emission spectra suggested higher separation rate for the photo-generated electron–hole pairs in the P-25TiO{sub 2}/MT-PVAB/GP. The photocatalytic–adsorption removal experiments showed that the P-25TiO{sub 2}/MT-PVAB/GP enhanced removal rate of MB by an average of 4 times as compared with the immobilized monolayer P-25TiO{sub 2} on a glass plate (P-25TiO{sub 2}/GP).

36 MATERIALS SCIENCE↗

Removal, distribution and retention of metals in a constructed wetland over 20 years

The A-01 wetland treatment system (WTS) was designed to remove metals (primarily copper) from the effluent at the A-01 National Pollution Discharge Elimination System (NPDES) outfall at the Savannah River Site, Aiken, SC. This research investigated metal removal, distribution and retention in the A-01 WTS over a period of 20 years. The findings are important for ensuring continued metal sequestration in the A-01 WTSs over time, providing management guidance for constructed wetlands, and investigating changes in metal remediation effectiveness as a wetland ages. During 20 years of operation, systematic water and sediment sampling validated the wetlands' performance. After passage through the treatment cells, Cu concentrations were well below permit limits during all years of operation, often falling below 10 μg L -1 . Cu removal has been consistent over time, averaging about 80% despite large changes in influent Cu concentrations. Most divalent metals were rapidly removed from the water and held in the sediments shortly after the water entered the treatment wetland. Average removal of Pb from water by the wetland system was 67 and 74% in 2004 and 2020, respectively. Comparable values for Zn were 52 and 65%, respectively. Generally, the highest concentrations of Cu, Pb, and Zn were found in the sediment from the first cell in each pair of cells suggesting that most of the Cu, Pb, and Zn in the A-01 effluent was bound to the sediment quickly. Diffusive gradients in thin films (DGT) measurements of Cu and Zn in the sediments were much lower than bulk sediment concentrations. These results suggest that most of the Cu and Zn in the A-01 WTS sediments was not bioavailable, hence not toxic to aquatic organisms, as a likely consequence of adsorption to sediment particles and complexation with organic and inorganic substances.

54 ENVIRONMENTAL SCIENCES↗

The importance of ion kinetic energy for interference removal in ICP-MS/MS

Here, the effect of ion kinetic energy on gas phase ion reactivity with ICP-MS/MS was investigated in order to explore tuning strategies for interference removal. The collision/reaction gases CO 2 , N 2 O and O 2 were used to observe the ion product distribution for 48 elements using an Agilent tandem ICP-MS (ICP-MS/MS) as a function of reaction gas flow rate (pressure) and ion kinetic energy. The kinetic energy of the incident ion was varied by adjusting the octopole bias (V oct ). The three gases all form oxides (MO + ) as the primary product with differing reaction enthalpies that result in distinct differences in the ion energies required for reaction with product ion distributions that vary with Voct. Consequently, by varying the ion kinetic energy (i.e., V oct ), differences in interference reactivity can be used to achieve maximum separation. Three practical application examples were reported to demonstrate how the ion kinetic energy can be varied to achieve the ideal ion product distribution for interference resolution: CO 2 for the removal of 238 U in Pu analyses, CO 2 for the removal of 40 Ar 16 O vs. 56 Fe, and O 2 for the removal of Sm in Eu analyses, analogous to Pu/Am. The results demonstrate how the starting ion energy defined by V oct is an important factor to fully leverage the utility of any given reaction gas to remove interferences in the mass spectrum using ICP-MS/MS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Removal of H{sub 2}S using molten carbonate at high temperature

Highlights: • The performance of molten carbonate for the removal of H{sub 2}S improves at higher temperatures. • The degree of H{sub 2}S removal is significantly affected by the CO{sub 2} concentration in syngas. • Addition of carbon elements, such as char and tar, decrease the negative effects of CO{sub 2}. • Continuous addition of carbon elements into molten carbonate enables continuous desulfurization. • Desulfurization using molten carbonate is suitable for gasification gas. - Abstract: Gasification is considered to be an effective process for energy conversion from various sources such as coal, biomass, and waste. Cleanup of the hot syngas produced by such a process may improve the thermal efficiency of the overall gasification system. Therefore, the cleanup of hot syngas from biomass gasification using molten carbonate is investigated in bench-scale tests. Molten carbonate acts as an absorbent during desulfurization and dechlorination and as a thermal catalyst for tar cracking. In this study, the performance of molten carbonate for removing H{sub 2}S was evaluated. The temperature of the molten carbonate was set within the range from 800 to 1000 °C. It is found that the removal of H{sub 2}S is significantly affected by the concentration of CO{sub 2} in the syngas. When only a small percentage of CO{sub 2} is present, desulfurization using molten carbonate is inadequate. However, when carbon elements, such as char and tar, are continuously supplied, H{sub 2}S removal can be maintained at a high level. To confirm the performance of the molten carbonate gas-cleaning system, purified biogas was used as a fuel in power generation tests with a molten carbonate fuel cell (MCFC). The fuel cell is a high-performance sensor for detecting gaseous impurities. When purified gas from a gas-cleaning reactor was continuously supplied to the fuel cell, the cell voltage remained stable. Thus, the molten carbonate gas-cleaning reactor was found to afford good gas-cleaning performance.

09 BIOMASS FUELS↗

How do operating conditions affect As(III) removal by iron electrocoagulation?

Iron electrocoagulation (Fe-EC) has been shown to effectively remove arsenic from contaminated groundwater at low cost and has the potential to improve access to safe drinking water for millions of people. Understanding how operating conditions, such as the Fe dosage rate and the O 2 recharge rate, affect arsenic removal at different pH values is crucial to maximize the performance of Fe-EC under economic constraints. In this work, we improved upon an existing computational model to investigate the combined effects of pH, Fe dosage rate, and O 2 recharge rate on arsenic removal in Fe-EC. We showed that the impact of the Fe dosage rate strongly depends on pH and on the O 2 recharge rate, which has important practical implications. We identified the process limiting arsenic removal (As(III) oxidation versus As(V) adsorption) at different pH values, which allowed us to interpret the effect of operating conditions on Fe-EC performance. Finally, we assessed the robustness of the trends predicted by the model, which assumes a constant pH, against lab experiments reproducing more realistic conditions where pH is allowed to drift during treatment as a result of equilibration with atmospheric CO 2 . Furthermore, our results provide a nuanced understanding of how operating conditions impact arsenic removal by Fe-EC and can inform decisions regarding the operation of this technology in a range of groundwaters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient Removal of Per- and Polyfluoroalkyl Substances from Water with Zirconium-Based Metal–Organic Frameworks

Per- and polyfluoroalkyl substances (PFASs) are an emerging class of contaminants raising increased levels of concern due to their toxic, bioaccumulative, and persistent nature. Current solutions for removing PFAS from contaminated water rely on adsorption-based methods where commonly used sorbents, for example, activated carbons and ion-exchange resins, exhibit low adsorption capacity and a long equilibration time. Motivated by the generally deficient performance of these current materials, this work addresses the need for the discovery of advanced sorbents for high capacity and efficient PFAS removal. The zirconium-based metal–organic framework (MOF) NU-1000 was characterized for the adsorption of three perfluorosulfonic acids (PFSAs, C4–C8) and six perfluorinated carboxylic acids (PFCAs, C1–C9) from aqueous solutions. Here, the results indicate that NU-1000 exhibits outstanding adsorption capacities of 400–620 mg/g for PFSAs and 201–604 mg/g for PFCAs coupled with ultrafast adsorption kinetics featuring equilibrium times of <1 min. Complementary density functional theory calculations reveal that the PFAS@MOF adsorption mechanism is dominated by a combination of hydrogen bonding, electrostatic, and hydrophobic non-covalent PFAS–MOF interactions. Excellent regeneration and reusability characteristics were found, particularly nearly quantitative removal and recovery rates of NU-1000 after five consecutive adsoption and desorption cycles of PFAS. Additional adsorption testing using PFAS-contaminated groundwater samples obtained from U.S. Air Force bases revealed impressive PFAS removal rates of 75–98% within 10 min regardless of the presence of co-contaminants. To the best of our knowledge, the suite of herein presented PFAS sorption characteristics—capacity, kinetics, regeneration, and reusability—significantly outperforms other current sorbents, rendering NU-1000 as a promising platform for the rapid and effective removal of PFAS from aqueous media.

36 MATERIALS SCIENCE↗

The Potential and Cost of Carbon Dioxide Removal Using Direct Air Capture with Land-Based Wind and Utility-Scale Photovoltaics

The rapid deployment of direct air capture and storage (DACS) is critical for achieving emission targets, necessitating precise evaluation of the scale and cost of carbon dioxide removal. This study examines the availability of land, electricity generation, and geologic CO 2 storage within the United States, estimating a technical potential for low-temperature, adsorbent-based DACS to remove approximately 9 gigatonnes of CO 2 annually. By 2050, a substantial portion of this removal could be achieved at net-removed costs below $\$$300/tonneCO 2 , though costs are highly variable depending on factors such as facility scale, construction expenses, climate-dependent productivity and heating efficiency, and geologic storage conditions. In the short term, DACS deployment will help identify key research priorities for advancing technology and reducing removal costs. Concurrently, there is an urgent need for scientifically robust and standardized frameworks for monitoring, reporting, and verifying DACS performance across both established and emerging technologies and energy sources.

Carbon capture↗

Maximizing Marine Carbon Removal by Coupling Electrochemical and Biological Methods

Integrated development of emerging marine decarbonization strategies offers the possibility of lowering CO2 removal costs and enabling their widespread deployment. In this study we examine the feasibility and benefits of coupling electrochemical and biological marine carbon removal strategies. Bipolar membrane electrodialysis (BPMED) is used to generate acid and alkalinity from seawater and electricity, and the alkalinity is returned to the ocean for indirect CO2 removal from the atmosphere, but the acid stream is a waste product. Considering the large-scale of CO2 removal necessary, the acid storage, neutralization, and disposal have prohibitive costs and carbon footprint. Here we investigate the feasibility to valorize the acid stream to enhance the growth and CO2 uptake through photosynthesis in the fast-growing marine phytoplankter Picochlorum celeri. When added to active algae cultures, the BPMED-generated acidified seawater alters the carbonate-bicarbonate equilibrium thereby increasing the bioavailability of CO2 and the observed growth rates. Additions of up to 2 mM H+ from BPMED effluent streams increased algal productivity up to 3-fold. A high-level analysis conducted based on experimental data to estimate the potential of sequestered CO2 emissions when compared to conventional commercial means of acid utilization or disposal, is estimated to be ~30 kgCO2 / kgacid. Through further development and optimization in terms of choice of algal species, growth conditions, acid addition rates, etc. the combined electrochemical-biological approach has the potential to achieve higher net CO2 removal.

carbon dioxide, marine, marine algae↗

Ni-Doping Effects on Oxygen Removal from an Orthorhombic Mo 2 C (001) Surface: A Density Functional Theory Study

Density functional theory (DFT) calculations were used in this paper to investigate the effect of Ni dopants on the removal of chemisorbed oxygen (O*) from the Mo-terminated (T Mo ) and C-terminated (T C ) Mo 2 C(001) surfaces. The removal of adsorbed oxygen from the catalytic site is essential to maintain the long-term activity and selectivity of the carbide catalysts in the deoxygenation process related to bio-oil stabilization and upgrading. In this contribution, the computed reaction energetics and reaction barriers of O* removal were compared among undoped and Ni-doped Mo 2 C(001) surfaces. The DFT calculations indicate that selected Ni-doped surfaces such as Ni adsorbed on T Mo and T C Mo 2 C(001) surfaces enable weaker binding of important reactive intermediates (O*, OH*) compared to the undoped counterparts, which is beneficial for the O* removal from the catalyst surface. This study thus confirms the promoting effect of the Ni dopant on O* removal reaction on the T Mo Mo 2 C(001) and T C Mo 2 C(001) surfaces. Finally, this computational prediction has been confirmed by the temperature-programmed reduction profiles of Mo 2 C and Ni-doped Mo 2 C catalysts, which had been passivated and stored in an oxygen environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of Selenium Oxyanions from Aqueous Solutions by Ion Exchange: Equilibrium, Kinetics, and Mechanistic Modeling

Selenium (Se) is an essential micronutrient but toxic at high concentrations, posing challenges for water treatment. This study investigated the removal of selenate (SeO 4 2– ) and selenite (SeO 3 2– ) using the strong-base anion-exchange resin IRA-900, particularly in the presence of competing sulfate (SO 4 2– ). The performance of the commercially available resin IRA-900 was systematically investigated. The batch equilibrium behavior was studied in both single- and binary-component systems, and the kinetic behavior was investigated in single-component systems. Results confirmed a selectivity order of SeO 4 2– > SO 4 2– > SeO 3 2– , indicating preferential SeO 4 2– removal over competing SO 4 2– but lower affinity for SeO 3 2– . The maximum total exchange capacity was determined to be 2.04 mequiv/g. Furthermore, SeO 3 2– uptake was found to be pH-dependent, whereas SeO 4 2– uptake remained stable across a broad pH range. From a modeling perspective, the Law of Mass Action model effectively described equilibrium data, and a transport–reaction modeling framework captured removal kinetics of oxyanions including film and intraparticle diffusion. Finally, X-ray photoelectron spectroscopy confirmed ion exchange between chloride and Se oxyanions as the primary removal mechanism. These findings provide fundamental insights into the removal of Se oxyanions from aqueous solutions by ion exchange.

IRA-900↗

Temperature-programmed decomposition desorption of mercury species over activated carbon sorbents for mercury removal from coal-derived fuel gas

The mercury (Hg{sup 0}) removal process for coal-derived fuel gas in the integrated gasification combined cycle (IGCC) process will be one of the important issues for the development of a clean and highly efficient coal power generation system. Recently, iron-based sorbents, such as iron oxide (Fe{sub 2}O{sub 3}), supported iron oxides on TiO{sub 2}, and iron sulfides, were proposed as active mercury sorbents. The H{sub 2}S is one of the main impurity compounds in coal-derived fuel gas; therefore, H{sub 2}S injection is not necessary in this system. HCl is also another impurity in coal-derived fuel gas. In this study, the contribution of HCl to the mercury removal from coal-derived fuel gas by a commercial activated carbon (AC) was studied using a temperature-programmed decomposition desorption (TPDD) technique. The TPDD technique was applied to understand the decomposition characteristics of the mercury species on the sorbents. The Hg{sup 0}-removal experiments were carried out in a laboratory-scale fixed-bed reactor at 80-300{sup o}C using simulated fuel gas and a commercial AC, and the TPDD experiments were carried out in a U-tube reactor in an inert carrier gas (He or N{sub 2}) after mercury removal. The following results were obtained from this study: (1) HCl contributed to the mercury removal from the coal-derived fuel gas by the AC. (2) The mercury species captured on the AC in the HCl{sup -} and H{sub 2}S-presence system was more stable than that of the H{sub 2}S-presence system. (3) The stability of the mercury surface species formed on the AC in the H{sub 2}S-absence and HCl-presence system was similar to that of mercury chloride (HgClx) species. 25 refs., 12 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Near Quantitative Removal of Selenate and Sulfate Anions from Wastewaters by Cocrystallization with Chelating Hydrogen-Bonding Guanidinium Ligands

Selenium (Se) has become an environmental contaminant of aquatic ecosystems as a result of human activities, particularly mining, fossil fuel combustion, and agricultural activities. By leveraging the high sulfate concentrations relative to Se oxyanions (i.e., SeO n 2– , n = 3, 4) present in some wastewaters, we have developed an efficient approach to Se-oxyanion removal by cocrystallization with bisiminoguanidinium (BIG) ligands that form crystalline sulfate/selenate solid solutions. The crystallization of the sulfate, selenate and selenite, oxyanions and of sulfate/selenate mixtures with five candidate BIG ligands are reported along with the thermodynamics of crystallization and aqueous solubilities. Oxyanion removal experiments with the top two performing candidate ligands show a near quantitative removal (>99%) of sulfate or selenate from solution. When both sulfate and selenate are present, there is near quantitative removal (>99%) of selenate, down to sub-ppb Se levels, with no discrimination between the two oxyanions during cocrystallization. Reducing the selenate concentrations by 3 orders of magnitude or more relative to sulfate, as found in many wastewaters, led to no measurable loss in Se removal efficiencies. This work offers a simple and effective alternative to selective separation of trace amounts of highly toxic selenate oxyanions from wastewaters, to meet stringent regulatory discharge limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvent-mediated contaminant removal from plastic waste using thermodynamic modeling

Plastics recycling is hindered by the compositional complexity of plastic waste, which can include numerous polymer components as well as low concentrations of additives and non-intentionally added substances. These latter small-molecule species, which we collectively refer to as contaminants, can harm human health and will build up in recycled plastic causing environmental and downstream processing challenges if not removed. In this work, we present molecular modeling approaches using the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) to guide the selection of solvents that are capable of removing targeted contaminants from plastic waste. By considering the thermodynamic partitioning of contaminant species between a solvent phase and polymer phase, we identify guidelines for solvent selection to promote either the low-temperature extraction of contaminants from plastic waste or the removal of contaminants as part of a dissolution-based plastics recycling process. We present four case studies to illustrate the application of the computational approach to the removal of brominated flame retardants, phthalates, and selected perfluoroalkyl substances, and compare to both literature and newly collected experimental data to illustrate model prediction accuracy. Furthermore, the case studies highlight the capability of the modeling approach to help design recycling processes that explicitly account for contaminant removal, thereby increasing product purity during dissolution-based recycling or facilitating chemical recycling of contaminant-free plastics.

Zhou, Panzheng [University of, Wisconsin, Madison,↗

The outcome of supernovae in massive binaries; removed mass, and its separation dependence

The majority of massive stars are formed in binary systems. It is hence reasonable to expect that most core-collapse supernovae (CCSNe) take place in binaries and the existence of a companion star may leave some imprints in observed features. Having this in mind, we have conducted two-dimensional hydrodynamical simulations of the collisions of CCSNe ejecta with the companion star in an almost-equal-mass (∼10 M {sub ☉}) binary to find out possible consequences of such events. In particular we pay attention to the amount of mass removed and its dependence on the binary separation. In contrast to the previous surmise, we find that the companion mass is stripped not by momentum transfer but by shock heating. Up to 25% of the original mass can be removed for the closest separations and the removed mass decreases as M {sub ub}∝a {sup –4.3} with the binary separation a. By performing some experimental computations with artificially modified densities of incident ejecta, we show that if the velocity of ejecta is fixed, the density of incident ejecta is the single important parameter that actually determines the removed mass as M{sub ub}∝ρ{sub ej}{sup 1.4}. On the other hand, another set of simulations with modified velocities of incident ejecta demonstrate that the strength of the forward shock, which heats up the stellar material and causes the mass loss of the companion star, is actually the key parameter for the removed mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Selective Near-UV Ablation of Subgingival Dental Calculus: Measurement of Removal Rates

A noncontact profilometer (laser triangulation) was used to measure the removal rates of subgingival dental calculus irradiated with a frequency-doubled Ti:sapphire laser (60-ns pulse duration, 400-nm wavelength, 10-Hz repetition rate, 7-mJ pulse energy). Profilometer traces before and after irradiation were used to create a removal map with 4-μm axial and 15-μm transverse resolution. Twenty-three teeth (15 with calculus and 8 pristine) were irradiated at 90° and 45° under a cooling water spray with a super-Gaussian beam (~300-μm diameter). Subgingival calculus was selectively removed at 5.6 and 4.0 J/cm2 for 90° and 45°, respecetively, within a range of rates, between 2 to 9 μm/pulse. These ablation rates were constant during these exposures. For comparison, pristine cementum irradiated for 10 min at the same peak fluence and pulse repetition rate showed only craters, 15 to 50 μm deep, corresponding to an equivalent removal rate three orders of magnitude smaller than that obtained for calculus. Pristine enamel was not removed under the same irradiation conditions.

calculus↗

Internal Mammary Chain Sentinel Nodes in Early-Stage Breast Cancer Patients: Toward Selective Removal

Background: Removal of internal mammary chain sentinel nodes (IMCSNs) affects prognosis and treatment of breast cancer, and internal mammary chain radiotherapy (IMCRT) can improve survival for selected patients. This study aimed to determine the effect of IMCSN biopsy on recurrence-free survival (RFS) and overall survival (OS) and to identify predictive factors for IMCSN and distant metastasis. Methods: Patients with IMCSNs were selected from a prospective database for the period 1999–2007. Lymphoscintigraphy was performed after intratumoral technetium-99 m injection, and all sentinel nodes were removed. Both RFS and OS were calculated for subgroups with tumor-positive, tumor-negative, or non-removed IMCSNs. Predictive factors were identified for tumor-positive IMCSNs and distant metastasis by regression analysis. Results: For 287 (85%) of 336 patients, IMCSN biopsy was performed, and metastasis was detected in 38 patients (13%). The patients with tumor-positive IMCSNs had poorer OS than the patients with no IMCSN metastasis or non-removed IMCSNs (p = 0.002). These patients also had worse RFS due to distant metastasis (p = 0.002). Axillary metastasis was predictive for tumor-positive IMCSNs (positive predictive value, 38.5%). The predictive factors for distant metastasis were tumor-positive IMCSNs (hazard ratio [HR], 2.5), non-removed IMCSNs (HR, 2.3), tumor diameter greater than 1.5 cm (HR, 3.5), and age older than 65 years (HR, 3.1; reference, < 50 years). Conclusions: Patients with IMCSNs have worse survival due to distant metastasis. The clinically relevant predictive factor for distant metastasis is tumor larger than 1.5 cm. According to the authors’ current protocol, IMCSN biopsy is performed for patients younger than 70 years who have a tumor larger than 1.5 cm, with the cardiotoxicity of the adjuvant IMCRT weighed against the survival benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards predicting removal rate and surface roughness during grinding of optical materials

A series of controlled grinding experiments, utilizing loose or fixed abrasives of either alumina or diamond at various particle sizes, were performed on a wide range of optical workpiece materials [single crystals of Al 2 O 3 (sapphire), SiC, Y 3 Al 5 O 12 (YAG), CaF 2 , and LiB 3 O 5 (LBO); a SiO 2 -Al 2 O 3 -P 2 O 5 -Li 2 O glass ceramic (Zerodur); and glasses of SiO 2 :TiO 2 (ULE), SiO 2 (fused silica), and P 2 O 5 -Al 2 O 3 -K 2 O-BaO (Phosphate)]. The material removal rate, surface roughness, and the morphology of surface fractures were measured. Separately, Vickers indentation was performed on the workpieces, and the depths of various crack types as a function of applied load was measured. Single pass grinding experiments showed distinct differences in the spatial pattern of surface fracturing between the loose alumina abrasive (isolated indent-type lateral cracking) and the loose or fixed diamond abrasive (scratch-type elongated lateral cracking). Each of the grinding methods had a removal rate and roughness that scaled with the lateral crack slope, sℓ (i.e. the rate of increase in lateral crack depth with the applied load) of the workpiece material. A grinding model (based on the volumetric removal of lateral cracks accounting for neighboring lateral crack removal efficiency and the fraction of abrasive particles leading to fracture initiation) and a roughness model (based on the depth of lateral cracks or the interface gap between the workpiece and lap) are shown to quantitatively describe the material removal rate and roughness as a function of workpiece material, abrasive size, applied pressure and relative velocity. This broad, multi-process variable grinding model can serve as a predictive tool for estimating grinding rates and surface roughness for various grinding processes on different workpiece materials

36 MATERIALS SCIENCE↗