Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Sensitivity calibration of a Carestream HPX-1 image plate scanner

There is a need to measure the sensitivity of the image plate scanners used to scan Z shot data. The Carestream HPX-1 image plate scanner was tested, and its performance was characterized to determine the system sensitivity in terms of signal per incident photon as a function of x-ray energy. A Manson source was used to simultaneously expose an Amptek x-ray multi-channel analyzer and image plates, allowing for a comparison of the counts as a function of energy to the signal recorded on the image plates. NIST-certified radioactive sources were used to assign an absolute sensitivity. Results indicate that the HPX-1 scanner response matches the shape of the modeled response, allowing for absolute scaling using NIST-certified radioisotope sources. The HPX-1 scanner shows a stable response with measurements taken over one week. In contrast, the sensitivity of the DITABIS scanner was characterized using the same approach, but it exhibits changes in its response that varied by more than 50% over the span of 4 days.

42 ENGINEERING↗

Security of Mobile Radiological Sources: Overview of Industry Applied Technologies

Small radiological sources used in industrial settings recurrently require transit between job sites. Securing these sources, while stationary, can be addressed with standard security approaches and equipment. Transport of these sources increases the risk and complexity of managing and maintaining control of these sources. Implementing methodologies to securely monitor and locate sources improves response and resolution of anomalous events during transit. The Mobile Source Transit Security (MSTS) system was developed to improve security and provide situational awareness of these mobile sources throughout their job cycle. The MSTS development effort focused on creating a set of systems that could be successfully implemented in industrial radiography and well-logging applications. The MSTS team worked to address source presence and location through use and storage. The MSTS system monitors radiological sources as they move from the base of operations to the job site and back. The system provides near-real-time monitoring of the mobile source location and status and early notification of source loss or theft by transmitting operational status and alerting anomalous conditions over telematic links worldwide. The MSTS system can trigger an armed response or initiation of search and recovery operations and will automatically alert management and responsible staff if a radioactive source is lost or stolen whether it is on-site, in transport, or in storage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Stand-alone and Network Capable Pocket Radiation Detection System

A multi-functional and networked pocket radiation detection system has been developed at the Idaho National Laboratory (INL) capable of detecting and storing gamma ray and neutron data. The device can be used as a stand-alone device or in conjunction with an array to cover a small or large area. The device has programmable alarm trigger levels that can be modified for specific applications. The data is stored with a date/time stamp and can be transferred and viewed on a PDA via direct connection or, in networked configuration, wireless connection to a remote central facility upon request. Data functional/bench tests have been completed successfully and the device was demonstrated to detect radiation from a 55.6 uCi Cf-252 source at 5 meters and from 1.4 mCi Cf-252 source at 10 meters which exceeds both ANSI and IAEA standards for pocket radiation detection. In terms of sensitivity, this detection system detects neutron and gamma-ray fields down to 10 micro rem/hr levels and therefore can find the location of the radioactive source quickly. The detection system is small enough to be put in a pocket or clipped to a belt.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-05: Dosimetric Evaluation and Validation of Newlydeveloped Well Chamber for Use in the Calibration of Brachytherapy Sources

Purpose: To evaluate the dosimetric characteristics of newly developed well type ionization chamber and to validate the results with the commercially available calibrated well chambers that are being used for the calibration of brachytherapy sources. Methods: The newly developed well type ionization chamber (BDS 1000) has been designed for the convenient use in brachytherapy which is open to atmospheric condition. The chamber has a volume of 240 cm3 and weight of 2.5 Kg. The calibration of the radioactive source with activities from 0.01 mCi to 20 Ci can be carried out using this chamber. The dosimetric parameters such as leakage current, stability, scattering effect, ion collection efficiency, reference air kerma rate and nominal response with energy were carried out with the BDS 1000 well type ion chamber. The evaluated dosimetric characteristics of BDS1000 well chamber were validated with two other commercially available well chambers (HDR 1000 plus and BTC/3007). Results: The measured leakage current observed was negligible for the newly developed BDS 1000 well type ion chamber. The ion collection efficiency was close to 1 and the response of the chamber was found to be very stable. The determined sweet spot was at 42 mm from bottom of the chamber insert. The reference air kerma rate was found to be 4.634 × 105 Gym2hr-1A-1 for the BDS 1000 well chamber. The overall dosimetric characteristics of BDS 1000 well chamber was in good agreement with the dosimetric properties of other two well chambers. Conclusion: The dosimetric study shows that the newly developed BDS 1000 well type ionization chamber is high sensitive and reliable chamber for reference air kerma strength calibration. The results obtained confirm that this chamber can be used for the calibration of HDR and LDR brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

KATRIN background due to surface radioimpurities

The goal of the KArlsruhe TRItrium Neutrino (KATRIN) experiment is the determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c 2 at 90 % C.L. 1 . This goal can only be achieved with a very low background level in the order of 10 mcps 2 in the detector region of interest. A possible background source are α-decays on the inner surface of the KATRIN Main Spectrometer. Rydberg atoms, produced in sputtering processes accompanying the α-decays, are not influenced by electric or magnetic fields and freely propagate inside the vacuum of the Main Spectrometer. Here, they can be ionized by thermal radiation and the released electrons directly contribute to the KATRIN background. Two α-sources, 223 Ra and 228 Th, were installed at the Main Spectrometer with the purpose of temporarily increasing the background in order to study α-decay induced background processes. In this paper, we present a possible background generation mechanism and measurements performed with these two radioactive sources. Our results show a clear correlation between α-activity on the inner spectrometer surface and background from the volume of the spectrometer. Two key characteristics of the Main Spectrometer background – the dependency on the inner electrode offset potential, and the radial distribution – could be reproduced with this artificially induced background. These findings indicate a high contribution of α-decay induced events to the residual KATRIN background.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D Gamma Source Mapping and Intervention Analysis - 19243

3D gamma source mapping and intervention analysis, through Transco Products, Inc.'s RadVision3D{sup R}, uses the N-Visage Scanner{sup TM} by Createc combining laser scanning, optical imaging, and CZT (Cadmium Zinc Telluride) technologies to capture plant geometry, images, and gamma radiation data. By capturing multiple scans in an area of interest a full 3D analysis can be performed using N-Visage Fusion{sup TM} software by Createc which develops a 3D model showing radioactive sources in the environment and allowing various interventions, such as shielding or source removal, to be modeled virtually. The output of a RadVision3D{sup R} project is a scaled virtual environment that the user can 'walk through' on a PC for training and work planning activities. Included in the viewer are dose planes for the as-scanned conditions as well as for each intervention, showing the dose rate at any point in the room. A virtual dosimeter is built into the viewer to allow users to be fully immersed in the environment in which they will be working, without being exposed to actual radiation or other hazardous conditions. This technology can help save dose at operating nuclear power plants when used for planning large work scopes in high radiation areas and is valuable as a characterization tool for decommissioning facilities. Adopters of 3D gamma source mapping and intervention analysis save time, money, and dose by evaluating options well in advance of the performance of any work, and optimizing interventions using accurate modelling techniques to plan work evolutions. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative Measurements of X-ray Intensity

This chapter describes the characterization of several X-ray sources and their use in calibrating different types of X-ray cameras at National Security Technologies, LLC (NSTec). The cameras are employed in experimental plasma studies at Lawrence Livermore National Laboratory (LLNL), including the National Ignition Facility (NIF). The sources provide X-rays in the energy range from several hundred eV to 110 keV. The key to this effort is measuring the X-ray beam intensity accurately and traceable to international standards. This is accomplished using photodiodes of several types that are calibrated using radioactive sources and a synchrotron source using methods and materials that are traceable to the U.S. National Institute of Standards and Technology (NIST). The accreditation procedures are described. The chapter begins with an introduction to the fundamental concepts of X-ray physics. The types of X-ray sources that are used for device calibration are described. The next section describes the photodiode types that are used for measuring X-ray intensity: power measuring photodiodes, energy dispersive photodiodes, and cameras comprising photodiodes as pixel elements. Following their description, the methods used to calibrate the primary detectors, the power measuring photodiodes and the energy dispersive photodiodes, as well as the method used to get traceability to international standards are described. The X-ray source beams can then be measured using the primary detectors. The final section then describes the use of the calibrated X-ray beams to calibrate X-ray cameras. Many of the references are web sites that provide databases, explanations of the data and how it was generated, and data calculations for specific cases. Several general reference books related to the major topics are included. Papers expanding some subjects are cited.

47 OTHER INSTRUMENTATION↗

Determination of ammonia in ethylene using ion mobility spectrometry

A simple procedure to analyze ammonia in ethylene by ion mobility spectrometry is described. The spectrometer is operated with a silane polymer membrane., 63Ni ion source, H+ (H2O)n reactant ion, and nitrogen drift and source gas. Ethylene containing parts per billion (ppb) (v/v) concentrations of ammonia is pulled across the membrane and diffuses into the spectrometer. Preconcentration or preseparation is unnecessary, because the ethylene in the spectrometer has no noticeable effect on the analytical results. Ethylene does not polymerize in the radioactive source. Ethylene's flammability is negated by the nitrogen inside the spectrometer. Response to ammonia concentrations between 200 ppb and 1.5 ppm is near linear, and a detection limit of 25 ppb is calculated.

NASA Discipline Environmental Health↗

An inverse source location algorithm for radiation portal monitor applications

Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of particle deposition to and removal from clothing, skin, and hair after a radioactive airborne dispersal event

Explosive Radiological Dispersal Devices (RDD) – aka dirty bombs – are seen as a credible method to carry out a radiological terror attack. After exploding a radioactive source, the radionuclide-laden plume will be blown downwind of ground zero, with particles falling out and potentially depositing on people caught in and under the cloud. Some of these people may not show any sign of radiation sickness and therefore not realize they have been contaminated and may take the radioactive particulate with them on their daily activities, thus spreading the radioactive particulate outside the initially contaminated area. This paper reviews the scientific literature to better understand the rate at which particulate deposits on and is removed from the different “surfaces” of a person, i.e., hair, skin, and clothing. Prior research indicates that: 1) particle deposition is usually higher on skin than on hair and clothing; 2) particle deposition is greater for a person with higher skin moisture, 3) stronger wind increases the deposition flux onto a person, and 4) the fraction of particulate deposited on the hair, skin, and clothing respectively depends on the length of the hair, assuming all the hair surface is available for deposition. The studies taken into consideration show that the largest uncertainty in particulate deposition onto a person is due to clothing type because of the different possible weave arrangements and tightness which translate into differences in actual surface area and surface roughness. A factor of 2-to-20 variation in deposition rate was found. Removal of the particulate from the contaminated person may be due to wind, a person's movement, and/or contact transfer, i.e., by touching a different clean surface. Experiments show that the majority of the particulate is resuspended within 2–6 h mostly depending on the intensity of physical activity. The largest uncertainty in particulate removal from skin depends on the skin moisture, transfer rate of single-contact, and how many objects/people a person touches per hour. No data for hair were found for particle removal and resuspension. The studies considered did not utilize radionuclides directly; however, data on adhesion of radioactive vs. their non-radioactive counterpart have shown that the uncertainty due to the radioactivity of the particles is lower than that due to other factors. In conclusion, an idealized scenario involving a single building in the path of the cloud showed the impact of building-influenced flow on the cloud transport path and mixing, which affects the radiological dose the downwind population is exposed to and consequently the health effects.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Electrodeposition of actinide compounds from an aqueous ammonium acetate matrix. Experimental development and optimization

Electrodeposition is a technique that is routinely employed in nuclear research for the preparation of thin solid films of actinide materials which can be used in accelerator beam bombardments, irradiation studies, or as radioactive sources. The present study investigates the deposition of both lanthanides and actinides from an aqueous ammonium acetate electrolyte matrix. Electrodepositions were performed primarily on stainless steel disks; with yield analysis evaluated using -spectroscopy. Experimental parameters were studied and modified in order to optimize the uniformity and adherence of the deposition while maximizing the yield. The initial development utilized samarium as the plating material, with and without a radioactive tracer. As a result, surface characterization studies were performed by scanning electron microscopy, electron microprobe analysis, radiographic imaging, and x-ray diffraction.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CeSOX: Short-Distance Neutrino Oscillations with BoreXino

Several experimental anomalies in neutrino physics may point to the possible existence of one or more additional neutrino species that do not interact weakly, the so-called sterile neutrinos. The third phase of the Borexino experiment (SOX) is devoted to verification of this hypothesis. Within the first stage (CeSOX) the count rate of antineutrino events in the liquid scintillation detector from the artificial source {sup 1}44Ce–{sup 1}44Pr placed in the special pit beneath the setup will be measured. The smaller antineutrino flux, as compared to the original one, would indicate the presence of oscillations into sterile states. This paper gives a survey of the CeSOX experiment, including the general description, the characterization of the radioactive source and the specific features of its use, the description of the method for data analysis, and the expected results. Depending on the significance of the obtained scientific information, the decision on carrying out the second stage of the SOX experiment with the {sup 51}Cr source of electron neutrinos will be made.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation protection and instrumentation

Radiation was found not to be an operational problem during the Apollo program. Doses received by the crewmen of Apollo missions 7 through 17 were small because no major solar-particle events occurred during those missions. One small event was detected by a radiation sensor outside the Apollo 12 spacecraft, but no increase in radiation dose to the crewmen inside the spacecraft was detected. Radiation protection for the Apollo program was focused on both the peculiarities of the natural space radiation environment and the increased prevalence of manmade radiation sources on the ground and onboard the spacecraft. Radiation-exposure risks to crewmen were assessed and balanced against mission gain to determine mission constraints. Operational radiation evaluation required specially designed radiation detection systems onboard the spacecraft in addition to the use of satellite data, solar observatory support, and other liaison. Control and management of radioactive sources and radiation-generating equipment was important in minimizing radiation exposure of ground-support personnel, researchers, and the Apollo flight and backup crewmen.

J. Vernon Bailey↗

Measurement of low energy ionization signals from Compton scattering in a charge-coupled device dark matter detector [Measurement of low energy ionization signals from Compton scattering in a CCD dark matter detector]

In this paper, an important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental γ rays. We report detailed measurements of low-energy spectra from Compton scattering of γ rays in the bulk silicon of a charge-coupled device (CCD). Electron recoils produced by γ rays from 57 Co and 241 Am radioactive sources are measured between 60 eV and 4 keV. The observed spectra agree qualitatively with theoretical predictions, and characteristic spectral features associated with the atomic structure of the silicon target are accurately measured for the first time. A theoretically motivated parametrization of the data that describes the Compton spectrum at low energies for any incident γ-ray flux is derived. The result is directly applicable to background estimations for low-mass dark matter direct-detection experiments based on silicon detectors, in particular for the DAMIC experiment down to its current energy threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave profiling of snowpack free-water content

A microwave system is proposed to measure the amount of liquid-phase water in a snowpack operating in the range of 1 to 10 GHz. Attenuation of the beam between source and receivers is produced by the water in the snow. The relationships of frequency, distance, and volume percent of water are calculated for an assumed detector sensitivity, together with the estimated cost of a representative system. A laboratory test is described that shows the attenuation for snow at maximum wetness at 9.35 GHz. A configuration is proposed that involves a vertical tube containing microwave and radioactive sources and another vertical tube containing microwave and gamma-ray detectors, so that density and wetness profiles are obtained simultaneously over essentially the same path.

Linlor, W. I.↗

Safety assessment for the radon-type surface disposal facility at Saakadze, Georgia - 15406

The Saakadze disposal facility is located about 40 km from Tbilisi and was planned and constructed during Soviet times as Radon-type surface facility to accommodate up to 600 m{sup 3} of low and intermediate level waste generated on the territory of Georgia. The disposal facility was operated from 1963 until its closure in 1995. The vast majority of waste in the Saakadze facility has been disposed of in two near surface concrete vaults with typical Radon-type dimensions, which cover layers already show significant structural damages. In order to assess the present safety of the site and provide the competent Georgian authorities with the necessary basis to take decisions in regard to the future of the repository, the European Commission launched and financially supported a project, which was assigned to a consortium of TUV-Nord ENSYS GmbH and DBE Technology GmbH. The safety assessment of Saakadze facility, which was an essential part of this project and which is the subject of this paper was carried out by DBE Technology GmbH. The Government of Georgia has been gradually increasing efforts to improve the regulatory processes and the legislation on nuclear and radiation safety, and, in particular, on safe management of radioactive waste and sealed radioactive sources. Currently, however, there are still areas where specific Georgian laws and regulations do not exist. Accordingly, in certain aspects IAEA recommendations and best practices were used as guidelines for the methodology of the safety assessment. In spite of the large uncertainties to be considered, especially in regard to the inventory, preliminary results of the safety assessment indicate that scenarios related to the groundwater pathway do not lead to radiological impacts that are above or near to limiting values. However, human intrusion scenarios might lead to dose rates for the critical group that are exceeding these values. This is mainly due to the fact that today there is no proper engineered cover on top of the concrete vaults. Based on the comparison of existing options and considering the results of the long-term safety assessment, it is recommended to backfill the remaining voids inside the concrete vaults and to construct an engineered cover to reduce the probability of human intrusion scenarios and to minimize their potential impact. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Portland cement paste behaviour under gamma radiation field in geological repository - 15272

The Radioactive Waste Management Laboratory at the Nuclear and Energy Research Institute in Sao Paulo, Brazil (IPEN-CNEN-SP), is developing the concept of a repository for disposition of disused sealed radioactive sources in a deep borehole in which cement paste is intended to be used as a backfill between the steel casing and the geological formation around the borehole. The cement paste is intended to function as structural material, a blockage against the transport of water between the different strata of the geological setting, and as an additional barrier against the migration of radionuclides. The assessment of the cement paste behaviour in long term is necessary to increase the confidence that the material will perform as required during the service life of the facility. Under radiation, pore water present in cement paste suffers radiolysis and some products can be highly reactive, as electrons and hydroxyl radicals and hydrogen peroxide. These radiolysis products will interact with cement paste and its hydration products, forming a wide range of compounds. Previous work focused on assessing the synergic effects of radiation and environmental conditions, like higher temperature and aggressive groundwater chemicals, on cement paste. Examination of samples detected small differences in mineralogy and microstructure. However, the radiation dose to which samples were exposed (400 kGy) was only a fraction of the expected accumulated dose in cement paste until complete decay of some sealed sources in the repository. Therefore, several thousand kilo-grays must be tested the possibility of radiation to alter cement mineralogy and, as a consequence, its durability The objective of this research is to evaluate the changes in mineralogy and microstructure of irradiated cement paste specimens, in an attempt to establish a relationship between irradiation and durability. Cubic Portland cement specimens were casted and exposed to the gamma radiation of a 60 Co multipurpose irradiator, at IPEN-CNEN/SP. The effects of doses between 1000 kGy and 4000 kGy are evaluated by X-Ray Diffraction, Scanning Electron Microscopy, X-ray micro tomography, neutrongraphy and neutron scattering. This report presents the changes in cement paste mineralogy when samples are examined by XRD. Results indicate that durability can be affected because of the observed changes. Results are expected to indicate the induced changes in cement paste under high radiation doses and to provide hints on its behaviour in the long-term and service-life. The results can be used in safety analysis for deep geological repositories that use cement based materials as engineered barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗