Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pressure measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Basic Pressure Measurements at a Mach Number of 1.43 on a Thin 45 deg Sweptback Highly Tapered Wing with Systematic Spanwise Twist Variations

Pressure distributions are presented on four wings: an untwisted wing to serve as a reference, and wings with linear, quadratic and cubic twist variations along the span. All the twisted wings had 0deg twist at the 10-percent-semispan station and 6deg twist at the tip. The tests were made at a Mach number of 1.43 and covered an angle-of-attack range from -4deg to 20deg. The average Reynolds number based on the wing mean aerodynamic chord was 2.9 x 10(exp 6) during tests at a stagnation pressure of 1.0 atmosphere and 1.5 x 10(exp 6) during tests at a stagnation pressure of 0.5 atmosphere.

Mugler, John P., Jr.↗

Pressure measurements on an ogive-cylinder at high angles of attack with laminar, transitional, or turbulent separation

This paper reports results from pressure tests on an ogive-cylinder in the low-turbulence 12-foot pressure wind tunnel. The results consist of pressure distributions over a wide range of Reynolds numbers and angles of attack. The tests encompassed a complete coverage of different roll orientations shown to be essential in order to fully define all the possible flow conditions. When the various roll-angle results are combined, it is possible to interpret the effects of changing angle of attack or Reynolds number. Two basic mechanisms for producing asymmetric flow are identified. One mechanism operates in both the laminar and the fully turbulent separation regimes; this mechanism is the one qualitatively described by the impulsive flow analogy. The other mechanism occurs only in the transitional separation regime. This asymmetric flow has the same form as that in the two-dimensional crossflow on a circular cylinder in the transitional flow regime. Finally, these results make it possible to draw up critical Reynolds number boundaries between the laminar, transitional, and fully turbulent separation regimes throughout the angle-of-attack range from 20 to 90 deg.

Lamont, P. J.↗

High Pressure Measurement of Soot Formation Applicable to Energetic Materials Fireballs

The addition of hydrogen and oxygen to a hydrocarbon fuel mixture has a significant effect on its sooting tendencies at high pressures. Understanding the mechanism behind the formation of soot is key to proper chemical modeling of fireballs. The objective of this research is to investigate formation rates and soot induction times of intermediary chemicals resulting from energetic material combustion. Three intermediaries, acetylene (C2H2), ethylene (C2H4), and propyne (C3H4-P) are studied. Here, a laser spectroscopy system was utilized to measure soot formation, induction time, and detail the time histories of soot experiments performed using the University of Central Florida high pressure shock tube facility.

Loye, Timothy [University of Central Florida, Orla↗

Tabulated pressure measurements on an executive-type jet transport model with a supercritical wing

A 1/9 scale model of an existing executive type jet transport refitted with a supercritical wing was tested on in the 8 foot transonic pressure tunnel. The supercritical wing had the same sweep as the original airplane wing but had maximum thickness chord ratios 33 percent larger at the mean geometric chord and almost 50 percent larger at the wing-fuselage juncture. Wing pressure distributions and fuselage pressure distributions in the vicinity of the left nacelle were measured at Mach numbers from 0.25 to 0.90 at angles of attack that generally varied from -2 deg to 10 deg. Results are presented in tabular form without analysis.

Bartlett, D. W.↗

Surface pressure measurements on a series of two-dimensional yawmeter bodies

It is shown that certain two dimensional bodies exist having a sensitivity of surface pressure to flow direction which is much higher than for currently used two dimensional yawmeters. A body having a simple cross sectional shape was selected for experimental evaluation at low Mach number, but at a typical Reynolds number for such instruments.

Goodyer, M. J.↗

In-flight flow visualization and pressure measurements at low speeds on the NASA F-18 high alpha research vehicle

Inflight results from surface and off surface flow visualizations and from extensive pressure distributions document the vortical flow on the leading edge extensions (LEXs) and forebody of the NASA F-18 high alpha research vehicle (HARV) for low speeds and angles of attack up to 50 deg. Surface flow visualization data, obtained using the emitted fluid technique, were used to define separation lines and laminar separation bubbles (LSB). Off surface flow visualization data, obtained by smoke injection, were used to document both the path of the vortex cores and the location of vortex core breakdown. The location of vortex core breakdown correlated well with the loss of suction pressure on the LEX and with the flow visualization results from ground facilities. Surface flow separation lines on the LEX and forebody corresponded well with the end of pressure recovery under the vortical flows. Correlation of the pressures with wind tunnel results show fair to good correlation.

John H Del Frate↗

In-flight flow visualization with pressure measurements at low speeds on the NASA F-18 high alpha research vehicle

In-flight results from surface and off-surface flow visualizations and from extensive pressure distributions document the vortical flow on the leading edge extensions (LEX) and forebody of the NASA F-18 high alpha research vehicle for low speeds and angles of attack up to 50 degs. Surface flow visualization data, obtained using the emitted fluid technique, were used to define separation lines and laminar separation bubbles. Off-surface flow visualization data, obtained by smoke injection, were used to document both the path of the vortex cores and the location of vortex core breakdown. The location of vortex core breakdown correlated well with the loss of suction pressure on the LEX and with the flow visualization results from ground facilities. Surface flow separation lines on the LEX and forebody corresponded well with the end of pressure recovery under the vortical flows. Correlation of the pressures with wind tunnel results show fair to good correlation.

Delfrate, John H.↗

Heat transfer and pressure measurements for the SSME fuel-side turbopump

A measurement program is currently underway at the Calspan-UB Research Center (CUBRC) which utilizes the Rocketdyne two-state fuel-side turbine with the engine geometric configuration reproduced. This is a full two-state turbine for which the vane rows and the blades are the engine hardware currently used on the Space Shuttle turbopump. A status report is provided for the experimental program and a description of the instrumentation and the measurements to be performed. The specific items that will be illustrated and described are as follows: (1) the gas flow path, (2) the heat-flux instrumentation, (3) the surface-pressure instrumentation, (4) the experimental conditions for which data will be obtained, and (5) the specific measurements that will be performed.

Dunn, Michael G.↗

Comparison between Computational and Experimental Wall-Shear Stress and Pressure Measurements in a Supersonic Wind Tunnel

We study the performance of two selected RANS models (SST-$k$-$\omega$ and Baldwin-Lomax) to simulate the mean wall-shear and pressure data obtained from a distributed-roughness-related experimental campaign conducted at Ahmic Aerospace, LLC, located in Ohio, US. A structured compressible Navier-Stokes in-house solver, DPLR, is used to conduct the RANS simulations. As the final objective is to perform the studies under high-enthalpy flow conditions, such as inside the AHF facility at NASA-Ames Research Center (ARC), the current investigation focuses on the low-enthalpy cases using Ahmic's high-Reynolds-number supersonic wind tunnel as the initial step to simplify the flow physics. Furthermore, the wind tunnel simulations are conducted with perfectly-smooth walls to further simplify the problem and perform the initial testing of different solver-based RANS models. The Baldwin-Lomax model is observed to be more accurate than the SST model. However, when these RANS models and their roughness augmentation models are utilized to study their accuracy with respect to the experimental datasets, where the roughness effects are activated, both models perform well for a low roughness height case. However, as the roughness height increases, the SST model more accurately predicts the wall data (shear and pressure) than the Baldwin-Lomax model. Therefore, this present work has built a solid foundation for selecting the best RANS model to study the wall data under high-enthalpy flow conditions at the AHF facility soon.

Prakash Shrestha↗

Method development for compensating temperature effects in pressure sensitive paint measurements

Pressure sensitive luminescent paints (PSP) have recently emerged as a viable technique for aerodynamic pressure measurements. The technique uses a surface coating which contains probe molecules that luminesce when excited by light of an appropriate wavelength. The photoluminescence of these materials is known to be quenched by the presence of molecular oxygen. Since oxygen is a fixed mole fraction of the air, the coating's luminescence intensity varies inversely with air pressure. Digital imaging of the luminescence varying across a coated surface produces a pressure distribution map over that surface. One difficulty encountered with this technique is the temperature effect on the luminescence intensity. Present PSP formulations have significant sensitivity to temperature. At the moment, the most practical way of correcting for temperature effects is to calibrate the paint in place at the operating temperatures by using a few well-placed pressure taps. This study is looking at development of temperature indicating coatings that can be applied and measured concurrently with PSP, and use the temperature measurement to compute the correct pressure. Two methods for this dual paint formulation are proposed. One method will use a coating that consists of temperature sensitive phosphors in a polymer matrix. This is similar in construction to PSP, except that the probe molecules used are selected primarily for their temperature sensitivity. Both organic phosphors (e.g., europium thenoyltrifluoroacetonate, bioprobes) and inorganic phosphors (e.g., Mg4(F)GeO6:Mn, La2O2S:Eu, Radelin Type phosphors, Sylvania Type phosphors) will be evaluated for their temperature sensing potential. The next method will involve a novel coating composing of five membered heterocyclic conducting polymers which are known to show temperature dependent luminescence (e.g., poly(3-alkylthiopene), poly(3-alkylselenophene), poly(3-alkylfuran)). Both methods will involve applying a bottom layer of temperature sensitive coating followed by a top coating of PSP. An oxygen-impermeable polymer can be used as the temperature sensitive coating matrix, or it can be layered in between the coatings to prevent oxygen quenching of the bottom coating's luminescence. The probe molecules of the coatings will be excited by a broad band of light, with the different emissions detected and measured at their distinct wavelengths. Developmental research of these coatings is still in progress; however, preliminary results look very promising.

Demandante, Carlo Greg N.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems

The following projects involving cardiovascular instrumentation were conducted: (1) the development and fabrication of a three-dimensional display measurement system for vectorcardiograms, (2) the development and fabrication of a cardiovascular monitoring system to noninvasively monitor beat-by-beat the blood pressure and heart rate using aortic pulse wave velocity, (3) the development of software for an interactive system to analyze systolic time interval data, and (4) the development of microprocessor-based physiologic instrumentation, focussing initially on EKG rhythm analysis. Brief descriptions of these projects were given.

Mark, R. G.↗

Application of digital holographic interferometry to pressure measurements of symmetric, supercritical, and circulation control airfoils in transonic flow fields

Six airfoil interferograms were evaluated using a semiautomatic image-processor system which digitizes, segments, and extracts the fringe coordinates along a polygonal line. The resulting fringe order function was converted into density and pressure distributions and a comparison was made with pressure transducer data at the same wind tunnel test conditions. Three airfoil shapes were used in the evaluation to test the capabilities of the image processor with a variety of flows. Symmetric, supercritical, and circulation-control airfoil interferograms provided fringe patterns with shocks, separated flows, and high-pressure regions for evaluation. Regions along the polygon line with very clear fringe patterns yielded results within 1 percent of transducer measurements, while poorer quality regions, particularly near the leading and trailing edges, yielded results that were not as good.

Torres, Francisco J.↗

Application of digital holographic interferometry to pressure measurements of symmetric, supercritical and circulation-control airfoils in transonic flow fields

Six airfoil interferograms were evaluated using a semiautomatic image-processor system which digitizes, segments, and extracts the fringe coordinates along a polygonal line. The resulting fringe order function was converted into density and pressure distributions and a comparison was made with pressure transducer data at the same wind tunnel test conditions. Three airfoil shapes were used in the evaluation to test the capabilities of the image processor with a variety of flows. Symmetric, supercritical, and circulation-control airfoil interferograms provided fringe patterns with shocks, separated flows, and high-pressure regions for evaluation. Regions along the polygon line with very clear fringe patterns yielded results within 1% of transducer measurements, while poorer quality regions, particularly near the leading and trailing edges, yielded results that were not as good.

Torres, Francisco J.↗

Blade surface pressure measurement on a pusher propeller in flight

Unsteady aerodynamics of a pusher propeller operating in the wake of a pylon is investigated through analysis of flight test data. Twenty-two surface-mounted miniature pressure transducers were installed at the 75 and 90 percent radius locations on a propeller blade on a test-bed aircraft. Twenty-six different flight conditions were flown to cover the range of speeds, rpm, altitudes, and flap positions encountered by an advanced turboprop general aviation aircraft. Preliminary analysis of the flight test data indicate a strong three-dimensionality to the perturbed flow at the 75 and 90 percent radii due to pylon wake encounter. Time-history of the pressure transducer waveforms recorded for 700 revolutions exhibit a one-per-cycle wave oscillation on the wake signature. No explanation is found for this behavior yet.

Farokhi, S.↗

Steady and Periodic Pressure Measurements on a Generic Helicopter Fuselage Model in the Presence of a Rotor

A wind tunnel test of a generic helicopter fuselage model with an independently mounted rotor has been conducted to obtain steady and periodic pressure data on the helicopter body. The model was tested at four advance ratios and three thrust coefficients. The periodic unsteady pressure coefficients are marked by four peaks associated with the passage of the four rotor blades. Blade passage effects are largest on the nose and tail boom of the model. The magnitude of the pulse increases with rotor thrust coefficient. Tabular listings of the unsteady pressure data are included to permit independent analysis. A CD-rom containing the steady and unsteady pressure data presented in the report is available from the authors.

Mineck, Raymond E.↗