Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Observable optimization for precision theory: machine learning energy correlators

The practice of collider physics typically involves the marginalization of multi-dimensional collider data to uni-dimensional observables relevant for some physics task. In many cases, such as classification or anomaly detection, the observable can be arbitrarily complicated, such as the output of a neural network. However, for precision measurements, the observable must correspond to something computable systematically beyond the level of current simulation tools. In this work, we demonstrate that precision-theory-compatible observable space exploration can be systematized by using neural simulation-based inference techniques from machine learning. We illustrate this approach by exploring the space of marginalizations of the energy 3-point correlator to optimize sensitivity to the top quark mass. We first learn the energy-weighted probability density from simulation, then search in the space of marginalizations for an optimal triangle shape. Although simulations and machine learning are used in the process of observable optimization, the output is an observable definition which can be then computed to high precision and compared directly to data without any memory of the computations which produced it. We find that the optimal marginalization is isosceles triangles on the sphere with a side ratio approximately $1 : 1 : \sqrt{2}$ (i.e. right triangles) within the set of marginalizations we consider.

Jets and Jet Substructure↗

Type-I 2HDM under the Higgs and electroweak precision measurements

We explore the extent to which future precision measurements of the Standard Model (SM) observables at the proposed Z -factories and Higgs factories may have impacts on new physics beyond the Standard Model, as illustrated by studying the Type-I Two-Higgs-doublet model (Type-I 2HDM). We include the contributions from the heavy Higgs bosons at the tree-level and at the one-loop level in a full model-parameter space. While only small tan β region is strongly constrained at tree level, the large tan β region gets constrained at loop level due to tan β enhanced tri-Higgs couplings. We perform a multiple variable χ 2 fit with non-alignment and non-degenerate masses. We find that the allowed parameter ranges could be tightly constrained by the future Higgs precision measurements, especially for small and large values of tan β . Indirect limits on the masses of heavy Higgs bosons can be obtained, which can be complementary to the direct searches of the heavy Higgs bosons at hadron colliders. We also find that the expected accuracies at the Z -pole and at a Higgs factory are quite complementary in constraining mass splittings of heavy Higgs bosons. The typical results are | cos( β - α ) | < 0 . 05 , | Δ m Φ | < 200 GeV, and tan β ≳ 0 . 3. The reaches from CEPC, Fcc-ee and ILC are also compared, for both Higgs and Z -pole precision measurements. Comparing to the Type-II 2HDM, the 95% C.L. allowed range of cos( β - α ) is larger, especially for large values of tan β .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Higgs-precision constraints on colored naturalness

The presence of weak-scale colored top partners is among the simplest solutions to the Higgs hierarchy problem and allows for a natural electroweak scale. We examine the constraints on generic colored top partners coming solely from their effect on the production and decay rates of the observed Higgs with a mass of 125 GeV. We use the latest Higgs precision data from the Tevatron and the LHC as of EPS 2017 to derive the current limits on spin-0, spin-1/2, and spin-1 colored top partners. We also investigate the expected sensitivity from the Run 3 and Run 4 of the LHC, as well from possible future electron-positron and proton-proton colliders, including the ILC, CEPC, FCC-ee, and FCC-hh. We discuss constraints on top partners in the Minimal Supersymmetric Standard Model and Little Higgs theories. We also consider various model-building aspects — multiple top partners, modified couplings between the Higgs and Standard-Model particles, and non-Standard-Model Higgs sectors — and evaluate how these weaken the current limits and expected sensitivities. By modifying other Standard-Model Higgs couplings, we find that the best way to hide low-mass top partners from current data is through modifications of the top-Yukawa coupling, although future measurements of top-quark-pair production in association with a Higgs will extensively probe this possibility. We also demonstrate that models with multiple top partners can generically avoid current and future Higgs precision measurements. Nevertheless, some of the model parameter space can be probed with precision measurements at future electron-positron colliders of, for example, the e + e - → Zhcrosssection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tracking Error Learning Control for Precise Mobile Robot Path Tracking in Outdoor Environment

This article presents a Tracking-Error Learning Control (TELC) algorithm for precise mobile robot path tracking in off-road terrain. In traditional tracking error-based control approaches, feedback and feedforward controllers are designed based on the nominal model which cannot capture the uncertainties, disturbances and changing working conditions so that they cannot ensure precise path tracking performance in the outdoor environment. In TELC algorithm, the feedforward control actions are updated by using the tracking error dynamics and the plant-model mismatch problem is thus discarded. Therefore, the feedforward controller gradually eliminates the feedback controller from the control of the system once the mobile robot has been ontrack. In addition to the proof of the stability, it is proven that the cost functions do not have local minima so that the coefficients in TELC algorithm guarantee that the global minimum is reached. The experimental results show that the TELC algorithm results in better path tracking performance than the traditional tracking error-based control method. The mobile robot controlled by TELC algorithm can track a target path precisely with less than 10 cm error in off-road terrain.

42 ENGINEERING↗

Calculation of machine precision second order derivatives using dual-complex numbers

It is well known that both complex and dual numbers can be employed to obtain machine precision first-order derivatives; however, neither, on their own, can compute machine precision 2nd order derivatives. To address this limitation, it is demonstrated in this paper that combined dual-complex numbers can be used to compute machine precision 1st and 2nd order derivatives. The dual-complex approach is simpler than utilizing multicomplex or hyper-dual numbers as existing dual libraries can be used as is or easily augmented to accept complex numbers, and the complexity of developing, integrating, and deploying multicomplex or hyper-dual libraries is avoided. The efficacy of this approach is demonstrated for both univariate and multivariate functions. Finally, source code examples using the Python, Julia, and Mathematica languages are provided as supplemental material.

97 MATHEMATICS AND COMPUTING↗

Precision spectroscopy of the helium atom.

Persistent efforts in both theory and experiment have yielded increasingly precise understanding of the helium atom. Because of its simplicity, the helium atom has long been a testing ground for relativistic and quantum electrodynamic effects in few-body atomic systems theoretically and experimentally. Comparison between theory and experiment of the helium spectroscopy in 1s2p{sup 3}P{sub J} can potentially extract a very precise value of the fine structure constant a. The helium atom can also be used to explore exotic nuclear structures. In this paper, we provide a brief review of the recent advances in precision calculations and measurements of the helium atom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Results on Setup Precision of Prone-Lateral Patient Positioning for Whole Breast Irradiation

Purpose: The aim of this study was to develop a rapid and reproducible technique for prone positioning and to compare dose-volume indices in prone and supine positions. Methods and Materials: Eighteen patients underwent computed tomography imaging for radiotherapy planning in prone and supine position. Experience was gained in the first eight patients, which lead to modifications of the Horizon prone breast board (Civco Medical Solutions, Orange City, Iowa, USA) and the patient setup technique. A unilateral breast holder (U-BH) was developed (Van de Velde, Schellebelle, Belgium) to retract the contralateral breast away from the treated breast. The technique was then applied to an additional 10 patients. The setup precision was evaluated using daily cone-beam CT. Results: Modifications to the breast board were made to secure a prone-lateral rather then a pure prone position. We evolved from a classical setup using laser marks on the patients' body to a direct breast setup using marks on the breast only. The setup precision of the direct positioning procedure with the modified breast board and the U-BH is comparable to supine setup data in the literature. Dose-volume indices for heart and lung show significantly better results for prone than for supine position, and dose homogeneity within the treated breast did not differ according to the treatment position. Conclusions: The setup precision of our prone-lateral positioning technique is comparable to supine data in literature. Our data show the advantage of prone radiotherapy to spare the lung and heart. Further research is necessary to reduce the duration of prone setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Assessment of Patterns of Failure After High-Precision Definitive (Chemo)Radiation in Head-and-Neck Squamous Cell Carcinoma

Purpose: To prospectively analyze patterns of failure in patients with head-and-neck squamous cell carcinoma treated with definitive high-precision radiotherapy with a focus on location of failure relative to target volume coverage. Methods and Materials: Sixty patients treated with three-dimensional conformal radiotherapy or intensity-modulated radiation therapy were included. Locoregional failure volume was defined on the planning data set at relapse, and dose received was analyzed by use of dose-volume histograms. Results: Thirteen patients were deemed to have had locoregional failures, of which two did not have any viable tumor on salvage neck dissection, leaving eleven patients with proven persistent or recurrent locoregional disease. Of these, 9 patients had in-field failure, 1 marginal failure, and 1 both in-field and marginal failures. Overall, only 2 of 11 patients (18%) with relapse had any marginal failure. Of the 20 sites of locoregional failure, 15 (75%) were in-field and 5 (25%) marginal. Distant metastases were detected in 3 patients, whereas a second new primary developed in 3 others. With a median follow-up of 26 months (interquartile range, 18-31 months) for surviving patients, the 3-year local control, locoregional control, disease-free survival, and overall survival rates were 75.3%, 74%, 67.2%, and 60.5%, respectively. Conclusions: Locoregional relapse remains the predominant pattern of failure in head-and-neck squamous cell carcinoma treated with high-precision definitive radiotherapy with the majority of failures occurring 'in-field' within the high-dose volume. Marginal failures can occur, particularly in the vicinity of the spared parotid gland. The therapeutic index of high-precision conformal radiotherapy is largely dependent on adequate selection and delineation of target volumes and organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternated Prone and Supine Whole-Breast Irradiation Using IMRT: Setup Precision, Respiratory Movement and Treatment Time

Purpose: The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. Methods and Materials: Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded. Results: Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes <1 mm in both positions. Treatment slots were longer in prone position (21.2 {+-} 2.5 min) than in supine position (19.4 {+-} 0.8 min; p = 0.044). Conclusion: Comparison of setup precision between prone and supine position in the same patient showed no significant differences in random and systematic errors. Respiratory movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Big Data Analytics to Advance Precision Radiation Oncology

Big clinical data analytics as a primary component of precision medicine is discussed, identifying where these emerging tools fit in the spectrum of genomics and radiomics research. A learning health system (LHS) is conceptualized that uses clinically acquired data with machine learning to advance the initiatives of precision medicine. The LHS is comprehensive and can be used for clinical decision support, discovery, and hypothesis derivation. These developing uses can positively impact the ultimate management and therapeutic course for patients. The conceptual model for each use of clinical data, however, is different, and an overview of the implications is discussed. With advancements in technologies and culture to improve the efficiency, accuracy, and breadth of measurements of the patient condition, the concept of an LHS may be realized in precision radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy and Precision of an IGRT Solution

Image-guided radiotherapy (IGRT) can potentially improve the accuracy of delivery of radiotherapy treatments by providing high-quality images of patient anatomy in the treatment position that can be incorporated into the treatment setup. The achievable accuracy and precision of delivery of highly complex head-and-neck intensity modulated radiotherapy (IMRT) plans with an IGRT technique using an Elekta Synergy linear accelerator and the Pinnacle Treatment Planning System (TPS) was investigated. Four head-and-neck IMRT plans were delivered to a semi-anthropomorphic head-and-neck phantom and the dose distribution was measured simultaneously by up to 20 microMOSFET (metal oxide semiconductor field-effect transmitter) detectors. A volumetric kilovoltage (kV) x-ray image was then acquired in the treatment position, fused with the phantom scan within the TPS using Syntegra software, and used to recalculate the dose with the precise delivery isocenter at the actual position of each detector within the phantom. Three repeat measurements were made over a period of 2 months to reduce the effect of random errors in measurement or delivery. To ensure that the noise remained below 1.5% (1 SD), minimum doses of 85 cGy were delivered to each detector. The average measured dose was systematically 1.4% lower than predicted and was consistent between repeats. Over the 4 delivered plans, 10/76 measurements showed a systematic error > 3% (3/76 > 5%), for which several potential sources of error were investigated. The error was ultimately attributable to measurements made in beam penumbrae, where submillimeter positional errors result in large discrepancies in dose. The implementation of an image-guided technique improves the accuracy of dose verification, particularly within high-dose gradients. The achievable accuracy of complex IMRT dose delivery incorporating image-guidance is within {+-} 3% in dose over the range of sample points. For some points in high-dose gradients, submillimeter errors in position can lead to errors > 3%. The precision of the delivery system was demonstrated to be within the experimental noise of the detector system of 1.5% (1 SD)

61 RADIATION PROTECTION AND DOSIMETRY↗

A double-target system for precision measurements of nuclear medium effects

A double-target system has been developed for precision measurements of nuclear medium effects in unpolarized electron scattering with 4 5 GeV electron beams. This system allows for a precise comparison of elementary targets such as deuterium and hydrogen to heavy solid targets to study subtle medium effects such as color transparency, transverse momentum broadening, and hadron attenuation. One cryo-target and one solid target were located in the beam simultaneously, separated by 4 cm to minimize acceptance correction differences in the large CLAS spectrometer while maintaining the ability to identify the target event-by-event. Because both targets were positioned in the beam simultaneously, time-dependent systematic effects such as drifting gains or inefficient detector channels cancel in ratios of observables, increasing the precision of the final results. Measurements were performed with hydrogen and deuterium in combination with 3 mm diameter targets of carbon, aluminum, iron, tin,

Hakobyan, Hayk↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Precision Møller polarimetry for PREX-2 and CREX

The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically , be known with 1% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.89% for PREX-2, and 0.85% for CREX. The uncertainty is purely systematic, accumulated from several different sources, but dominated by our knowledge of the target polarization. Our analysis also demonstrates the need for accurate atomic wave functions in order to correct for the Levchuk Effect. We describe the details of the polarimeter operation and analysis, as well as (for CREX) a comparison to results from a different polarimeter based on Compton scattering.

43 PARTICLE ACCELERATORS↗

High-precision Q EC values of superallowed 0 + → 0 + β-emitters 46 Cr, 50 Fe and 54 Ni

Short-lived 46 Cr, 50 Fe and 54 Ni were studied by isochronous mass spectrometry at the HIRFL-CSR facility in Lanzhou. The measured precision mass excesses (ME) of 46 Cr, 50 Fe and 54 Ni are -29471(11) keV, -34477(6) keV and -39278(4) keV, respectively. The superallowed 0 + →0+β-decay Q values were derived to be Q EC ( 46 Cr) =7604(11) keV, Q EC ( 50 Fe) =8150(6) keV and Q EC ( 54 Ni) =8731(4) keV. The values for 50 Fe and 54 Ni are by one order of magnitude more precise than the adopted literature values. By combining the existing half-lives and branching ratios, we obtained the corrected ℱt values to be ℱt( 50 Fe) =3103(70) s and ℱt( 54 Ni) =3076(50) s. The main contribution to the ℱt uncertainties is now due to β-decay branching ratios, still, more high-precision measurements of the half-lives, the masses, and especially the branching ratios are needed in order to satisfy the requirements for a stringent CVC test.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision measurement of the Z boson invisible width in pp collisions at s = 13 TeV

A precise measurement of the invisible width of the Z boson produced in proton-proton collisions at a center-of-mass energy of 13 TeV is presented using data recorded by the CMS experiment at the LHC, corresponding to an integrated luminosity of 36.3 fb − 1 . The result is obtained from a simultaneous fit to kinematic distributions for two data samples of Z boson plus jets: one dominated by Z boson decays to invisible particles and the other by Z boson decays to muon and electron pairs. The invisible width is measured to be 523 ± 3 (stat) ± 16 (syst) MeV . This result is the first precise measurement of the invisible width of the Z boson at a hadron collider, and is the single most precise direct measurement to date, competitive with the combined result of the direct measurements from the LEP experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗