Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Optical communication with semiconductor laser diodes

A 25 megabit/sec direct detection optical communication system that used Q=4 PPM signalling was constructed and its performance measured under laboratory conditions. The system used a single-mode AlGaAs laser diode transmitter and low noise silicon avalanche photodiode (APD) photodetector. Comparison of measured performance with the theoretical revealed that modeling the APD output as a Gaussian process under conditions of negligible background radiation and low (less than 10 to the -12 power A) APD bulk leakage currents leads to substantial underestimates of optimal APD gain to use and overestimates of system bit error probability. A procedure is given to numerically compute system performance which uses the more accurate Webb's Approximation of the exact Conradi distribution for the APD ouput signal that does not require excessive amounts of computer time (a few minutes of VAX 8600 CPU time per system operating point). Examples are given which illustrate the breakdown of the Gaussian approximation in assessing system performance. This system achieved a bit error probability of 10 to the -6 power at a received signal energy corresponding to an average of 60 absorbed photons/bit and optimal APD gain of 700.

Davidson, F.↗

What should DOE do to help establish voluntary consensus standards for measuring and rating the performance of PV modules?

In response to concern expressed by the photovoltaics community over progress toward the establishment and issuance of concensus standards on photovoltaic performance measurements, a review of the status of and progress in developing these standards was conducted. It examined the roles of manufacturers, and consumers and the national laboratories funded by the U.S. Department of Energy (DOE) in supporting this effort. This was done by means of a series of discussions with knowledgeable members of the photovoltaic community. Results of these interviews are summarized and a new approach to managing support of standards activity is recommended that responds to specific problems found in the performance measurement standards area. The study concludes that there is a positive role to be played by the U.S. Department of Energy in establishing collector performance measurement standards. It recommends that DOE continue to provide direct financial support for selected committees and for research at national laboratories, and that management of the activity be restructured to increase the authority and responsibility of the consensus committees.

Runkle, L. D.↗

Effect of time span and task load on pilot mental workload

Two sets of simulations designed to examine how a pilot's mental workload is affected by continuous manual-control activity versus discrete mental tasks that included the length of time between receiving an assignment and executing it are described. The first experiment evaluated two types of measures: objective performance indicators and subjective ratings. Subjective ratings for the two missions were different, but the objective performance measures were similar. In the second experiments, workload levels were increased and a second performance measure was taken. Mental workload had no influence on either performance-based workload measure. Subjective ratings discriminated among the scenarios and correlated with performance measures for high-workload flights. The number of mental tasks performed did not influence error rates, although high manual workloads did increase errors.

Berg, S. L.↗

Performance model assessment for multi-junction concentrating photovoltaic systems.

Four approaches to modeling multi-junction concentrating photovoltaic system performance are assessed by comparing modeled performance to measured performance. Measured weather, irradiance, and system performance data were collected on two systems over a one month period. Residual analysis is used to assess the models and to identify opportunities for model improvement. Large photovoltaic systems are typically developed as projects which supply electricity to a utility and are owned by independent power producers. Obtaining financing at favorable rates and attracting investors requires confidence in the projected energy yield from the plant. In this paper, various performance models for projecting annual energy yield from Concentrating Photovoltaic (CPV) systems are assessed by comparing measured system output to model predictions based on measured weather and irradiance data. The results are statistically analyzed to identify systematic error sources.

14 SOLAR ENERGY↗

Measurement-based performance evaluation technique for high-performance computers

A measurement-based performance evaluation technique has been used to characterize the OS performance of Cedar, a hierarchical shared-memory multiprocessor system. Thirteen OS performance meters were used to capture the operating system activities for compute-bound workloads. Three representative applications from the Perfect Benchmark Suite were used to measure the OS performance in a dedicated system and in multiprogrammed workloads. It was found that 13-23 percent of the total execution time on a dedicated system was spent in executing OS-related activities. Under multiprogramming, 12-14 percent of the total execution time was used by the OS. The impact of multiprogramming on the operating system performance meters was also measured.

Sharma, S.↗

Performance model assessment for multi-junction concentrating photovoltaic systems.

Four approaches to modeling multi-junction concentrating photovoltaic system performance are assessed by comparing modeled performance to measured performance. Measured weather, irradiance, and system performance data were collected on two systems over a one month period. Residual analysis is used to assess the models and to identify opportunities for model improvement.

14 SOLAR ENERGY↗

Evaluating the effect of online data compression on the disk cache of a mass storage system

A trace driven simulation of the disk cache of a mass storage system was used to evaluate the effect of an online compression algorithm on various performance measures. Traces from the system at NASA's Center for Computational Sciences were used to run the simulation and disk cache hit ratios, number of files and bytes migrating to tertiary storage were measured. The measurements were performed for both an LRU and a size based migration algorithm. In addition to seeing the effect of online data compression on the disk cache performance measure, the simulation provided insight into the characteristics of the interactive references, suggesting that hint based prefetching algorithms are the only alternative for any future improvements to the disk cache hit ratio.

Pentakalos, Odysseas I.↗

Very Low Energy Homes in the United States: Perspectivies on Performance from Measured Data

This report describes how Florida Solar Energy Center measured annual performance data from a dozen recent-vintage very low energy homes in North America. Many of the designs combine greater energy efficiency with solar electric photovoltaic power in an attempt to create Zero Energy Homes. Data was also provided from the first home constructed to the German Passivhaus standard in the U.S.

(ZEH)↗

How Should Researchers Measure Perovskite-Based Monolithic Multijunction Solar Cells’ Performance? A Calibration Lab's Perspective

Perovskite multijunctions (PVSK MJs) have made remarkable progress with monolithic PVSK/PVSK tandems surpassing the efficiency of single-junction (1 J) PVSK cells and PVSK/Si cells reported to exceed the 30% efficiency mark. These efficiencies are reported at standard test conditions (STC), established by the photovoltaic (PV) community to facilitate comparison between devices and technologies. Herein, it is discussed why an accurate STC performance measurement for a MJ is more complicated than for a 1 J cell and the special aspects to be considered when measuring the current-voltage characteristics and the performance of PVSK-containing MJ cells are emphasized. It is discussed why a spectrally adjustable solar simulator is needed and the sequence of accurate performance measurement, namely measurement of the spectral response of each junction, adjustment of the spectrum, and appropriate protocols for measuring the power output of the device at STC, is presented. For all these, common errors and pitfalls that sometime lead to misleading interpretation of the results are presented, and the methods to evaluate the accuracy of the data when a spectrally adjustable solar simulator is not available are recommended. Finally, first step is taken toward recommending performance measurement approaches when high throughput is required as will eventually be in a production line.

14 SOLAR ENERGY↗

Measuring human performance on NASA's microgravity aircraft

Measuring human performance in a microgravity environment will aid in identifying the design requirements, human capabilities, safety, and productivity of future astronauts. The preliminary understanding of the microgravity effects on human performance can be achieved through evaluations conducted onboard NASA's KC-135 aircraft. These evaluations can be performed in relation to hardware performance, human-hardware interface, and hardware integration. Measuring human performance in the KC-135 simulated environment will contribute to the efforts of optimizing the human-machine interfaces for future and existing space vehicles. However, there are limitations, such as limited number of qualified subjects, unexpected hardware problems, and miscellaneous plane movements which must be taken into consideration. Examples for these evaluations, the results, and their implications are discussed in the paper.

Morris, Randy B.↗

Characterization and measurement of phase-locked loop performance

A set of performance measures and tests are presented which can be implemented at the 'black box' level for the characterization of such statistical aspects of phase-locked loop behavior as the acquisition and tracking threshold, phase error jitter, Doppler accuracy, etc. Also presented is an automatic measurement system, designated the Statistical Loop Analyzer, which has been developed in order to undertake these phase-locked device performance measurements.

Lindsey, W. C.↗

Measuring Distribution Performance? Benchmarking Warrants Your Attention

Identifying, designing, and measuring performance metrics is critical to securing customer value, but can be a difficult task. This article examines the use of benchmarks based on publicly available performance data to set challenging, yet fair, metrics and targets.

2017 customer value ranking↗

E AREA LOW LEVEL WASTE FACILITY DOE 435.1 PERFORMANCE ASSESSMENT

This Performance Assessment for the Savannah River Site E-Area Low-Level Waste Facility was prepared to meet requirements of Chapter IV of the Department of Energy Order 435.1-1. The Order specifies that a Performance Assessment should provide reasonable assurance that a low-level waste disposal facility will comply with the performance objectives of the Order. The Order also requires assessments of impacts to water resources and to hypothetical inadvertent intruders for purposes of establishing limits on radionuclides that may be disposed near-surface. According to the Order, calculations of potential doses and releases from the facility should address a 1,000-year period after facility closure. The point of compliance for the performance measures relevant to the all pathways and air pathway performance objective, as well as to the impact on water resources assessment requirement, must correspond to the point of highest projected dose or concentration beyond a 100-m buffer zone surrounding the disposed waste following the assumed end of active institutional controls 100 years after facility closure. During the operational and institutional control periods, the point of compliance for the all pathways and air pathway performance measures is the SRS boundary. However, for the water resources impact assessment, the point of compliance remains the point of highest projected dose or concentration beyond a 100-m buffer zone surrounding the disposed waste during the operational and institutional control periods. For performance measures relevant to radon and inadvertent intruders, the points of compliance are the disposal facility surface for all time periods and the disposal facility after the assumed loss of active institutional controls 100 years after facility closure, respectively. The E-Area Low-Level Waste Facility is located in the central region of the SRS known as the General Separations Area. It is an elbow-shaped, cleared area, which curves to the northwest, situated immediately north of the Mixed Waste Management Facility. The E-Area Low-Level Waste Facility is comprised of 200 acres for waste disposal and a surrounding buffer zone that extends out to the 100-m point of compliance. Disposal units within the footprint of the low-level waste facilities include the Slit Trenches, Engineered Trenches, Component-in-Grout Trenches, the Low-Activity Waste Vault, the Intermediate-Level Vault, and the Naval Reactor Component Disposal Area. Radiological waste disposal operations at the E-Area Low-Level Waste Facility began in 1994. E-Area Low-Level Waste Facility closure will be conducted in three phases: operational closure, interim closure, and final closure. Operational closure will be conducted during the 25-year operation period (30-year period for Slit and Engineered Trenches) as disposal units are filled; interim closure measures will be taken for some units. Interim closure will take place following the end of operations and will consist of an area-wide runoff cover along with additional grading over the trench units. Final closure of all disposal units in the E-Area Low-Level Waste Facility will take place at the end of the 100-year institutional control period and will consist of the installation of an integrated closure system designed to minimize moisture contact with the waste and to serve as a deterrent to intruders. Radiological dose to human receptors is analyzed in this PA in the all-pathways analysis, the inadvertent intruder analysis and the air pathway analysis, and the results are compared to the relevant performance measures. For the all-pathways analysis, the performance measure of relevance is a 25-mrem/yr EDE to representative members of the public, excluding dose from radon and its progeny in air. For the inadvertent intruder, the applicable performance measures are 100-mrem/yr EDE and 500 mrem/yr EDE for chronic and exposure scenarios, respectively. The relevant performance measure for the air pathway is 10-mrem/yr EDE via the air pathway, excluding dose from radon and its progeny in air. Protection of groundwater resources is addressed by comparing calculated compliance point concentrations in groundwater with the relevant performance measure, which was determined to be the Safe Drinking Water Act MCLs for beta-gamma and alpha-emitting radionuclides, and for radium and uranium. Radon fluxes for each disposal unit are calculated and compared to the average flux of 20 pCi/m{sup 2}/s upper limit specified in the relevant performance objective. Thirty-five parent radionuclides are addressed in the groundwater transport calculations, 15 radionuclides in the air pathway calculations, and 78 parent radionuclides in the intruder analysis for all disposal units. Radon-222 fluxes are also evaluated for all disposal units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of Situational Awareness Measures

A great deal of effort has been invested in attempts to define situational awareness, and subsequently to measure this construct. However, relatively less work has focused on the sensitivity of these measures to manipulations that affect the SA of the pilot. This investigation was designed to manipulate SA and examine the sensitivity of commonly used measures of SA. In this experiment, we tested the most commonly accepted measures of SA: SAGAT, objective performance measures, and SART, against different levels of SA manipulation to determine the sensitivity of such measures in the rotorcraft flight environment. SAGAT is a measure in which the simulation blanks in the middle of a trial and the pilot is asked specific, situation-relevant questions about the state of the aircraft or the objective of a particular maneuver. In this experiment, after the pilot responded verbally to several questions, the trial continued from the point frozen. SART is a post-trial questionnaire that asked for subjective SA ratings from the pilot at certain points in the previous flight. The objective performance measures included: contacts with hazards (power lines and towers) that impeded the flight path, lateral and vertical anticipation of these hazards, response time to detection of other air traffic, and response time until an aberrant fuel gauge was detected. An SA manipulation of the flight environment was chosen that undisputedly affects a pilot's SA-- visibility. Four variations of weather conditions (clear, light rain, haze, and fog) resulted in a different level of visibility for each trial. Pilot SA was measured by either SAGAT or the objective performance measures within each level of visibility. This enabled us to not only determine the sensitivity within a measure, but also between the measures. The SART questionnaire and the NASA-TLX, a measure of workload, were distributed after every trial. Using the newly developed rotorcraft part-task laboratory (RPTL) at NASA Ames Research Center, each pilot flew eight trials, four using SAGAT and four using performance measures. Each set of four trials differed by level of visibility as well. The flight paths were very similar in appearance and hazard number, allowing comparison between flight paths. The pilots were tasked with flying along a road at an assigned altitude and speed while avoiding any hazards that they happened upon. The attempt here was not to find a single best measure of SA, but rather to begin an investigation of the sensitivity of common measures of SA. Upon completion of this study, its results, in combination with future studies, should allow us to develop an empirically based taxonomy of SA measures and the contexts for their appropriate use.

Shively, R. J.↗

Streaked radiography measurements of convergent ablator performance (invited)

The velocity and remaining ablator mass of an imploding capsule are critical metrics for assessing the progress toward ignition of an inertially confined fusion experiment. These and other ablator rocket parameters have been measured using a single streaked x-ray radiograph. A regularization technique has been used to determine the ablator density profile {rho}(r) at each time step; moments of {rho}(r) then provide the areal density, average radius, and mass of the unablated, or remaining, ablator material, with the velocity determined from the time derivative of the average radius. The technique has been implemented on experiments at the OMEGA laser facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗